ML072670102

From kanterella
Jump to navigation Jump to search
9/06/2007 Summary of Meeting with Representatives of EOI for Waterford 3 Batwing Issues and Planned Actions During the Mid-Cycle Outage
ML072670102
Person / Time
Site: Waterford 
(NPF-038)
Issue date: 10/10/2007
From: Kalyanam N
NRC/NRR/ADRO/DORL/LPLIV
To:
Kalyanam N, NRR/DORL/LP4, 415-1480
Shared Package
ML072670094 List:
References
Download: ML072670102 (6)


Text

October 10, 2007 LICENSEE:

ENTERGY OPERATIONS INC. (EOI)

FACILITY:

WATERFORD STEAM ELECTRIC STATION, UNIT 3 (WATERFORD 3)

SUBJECT:

SUMMARY

OF SEPTEMBER 6, 2007, MEETING WITH REPRESENTATIVES OF EOI FOR WATERFORD 3 BATWING ISSUES AND PLANNED ACTIONS DURING THE MID-CYCLE OUTAGE On Thursday, September 6, 2007, a Category 1 public meeting was held between the Nuclear Regulatory Commission (NRC) staff and representatives of EOI, the licensee for Waterford, at NRC Headquarters, One White Flint North, 11555 Rockville Pike, Rockville, Maryland. The purpose of the meeting, held at the request of the licensee, was to provide to the NRC staff with an outline of its plans with regard to the batwing issues for the mid-cycle outage.

The presentation slides used during the meeting by the licensee, Enclosure 1, are available in the Agencywide Documents Access and Management System (ADAMS) under Accession No. ML072670108). The licensee outlined the Steam Generator monitoring activities, the overview of batwing mitigation strategy, activities planned during the mid-cycle outage, including special inspection tooling, inspection plans, contingency planning and evaluation, and foreign object search and retrieval processes.

Various aspects of EOI-generated Decision Tree were discussed which included visual and remote inspection plans, contingencies, testing and repair, stabilization of batwings, condition of tubes (dents and deformations), and acceptance criteria.

The licensee also stated the intent to review the acceptance criteria to ensure the criteria bound the analyses and perform sensitivity analyses, if out of bounds. The licensee also provided the mid-cycle communication plan between the licensee and the NRC staff that will help ensure prompt information exchange.

There were no members of the public represented at the meeting. A list of attendees is provided as Enclosure 2 is to this memorandum and the agenda for the meeting is available in ADAMS Accession No. ML072210439. There were no handouts from the NRC staff.

Please direct any inquiries to me at 301-415-1480.

/RA/

N. Kalyanam, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-382

Enclosures:

1. Licensees Handout
2. List of Attendees cc w/encls: See next page

Pkg ML072670094 Mtg Notice ML072210439, Mtg Summary ML072670102, Licensee Handout ML072670108 OFFICE DORL/LPL4/PM DORL/LPL4/LA DORL/LPL4/BC NAME NKalyanam JBurkhardt THiltz DATE 10/7/07 9/27/07 10/10/07

LICENSEE'S HANDOUT FOR SEPTEMBER 6, 2007, MEETING AGENCYWIDE DOCUMENTS ACCESS AND MANAGEMENT SYSTEM ACCESSION NO. ML072670108 The licensee's handout (58 pages) contained presentation slides entitled, "Entergy -

Waterford 3 Meeting with NRC on Steam Generator Batwing Issue, September 6, 2007.

ENCLOSURE 1

ATTENDANCE LIST SEPTEMBER 6, 2007 WATERFORD 3 STEAM GENERATOR BATWING MID-CYCLE PLANNED ACTIVITIES NAME ORGANIZATION*

TEL. NO.

Rex Putnam EOI/Waterford 3 504-464-3877 Robert Murillo EOI/Waterford 3 504-739-6715 Joe Kowalewski EOI/Waterford 3 504-464-3178 Robert Quinn EOI/Waterford 3 504-739-6387 John MaCann EOI/Waterford 3 914-272-3370 Keith Nichols Westinghouse 504-739-6310 Bill Cullen Westinghouse 724-722-5314 Peter Nelson Westinghouse 724-722-5971 Bill Heilker Westinghouse 423-752-2868 Jeff Hall Westinghouse 724-722-5134 Jeff Clark NRC/Region IV 817-860-8147 William B. Jones NRC/Region IV 817-860-8185 Allen Hiser NRC/NRR/CSGB 301-415-5650 Emmett Murphy NRC/NRR/CSGB 301-415-2710 Ken Karwoski NRC/NRR/CSGB 301-415-2752 Matt Yoder NRC/NRR/CSGB 301-415-4017 Andrew Johnson NRC/NRR/CSGB 301-415-1475 Margaret Stambough NRC/RES 301-415-7069 N. Kalyanam NRC/NRR/DORL 301-415-1480 EOI Entergy Operations Inc.

NRC Nuclear Regulatory Commission NRR Office of Nuclear Reactor Regulation CSGB Steam Generator Tube Integrity & Chemical Engineering Branch RES Office of Nuclear Regulatory Research DORL Division of Operating Reactor Licensing ENCLOSURE 2

September 2007 Waterford Steam Electric Station, Unit 3 cc:

Senior Vice President Entergy Nuclear Operations P.O. Box 31995 Jackson, MS 39286-1995 Senior Vice President and COO Entergy Operations, Inc.

P.O. Box 31995 Jackson, MS 39286-1995 Vice President, Operations Support Entergy Services, Inc.

P.O. Box 31995 Jackson, MS 39286-1995 Site Vice President Waterford Steam Electric Station, Unit 3 Entergy Operations, Inc.

17265 River Road Killona, LA 70057-3093 General Manager, Plant Operations Waterford Steam Electric Station, Unit 3 Entergy Operations, Inc.

17265 River Road Killona, LA 70057-3093 Director, Nuclear Safety & Licensing Entergy Services, Inc.

440 Hamilton Avenue White Plains, NY 10601 Director, Nuclear Safety Assurance Entergy Operations, Inc.

17265 River Road Killona, LA 70057-3093 Senior Manager, Nuclear Safety

& Licensing Entergy Services, Inc.

P.O. Box 31995 Jackson, MS 39286-1995 Manager, Licensing Entergy Operations, Inc.

17265 River Road Killona, LA 70057-3093 Louisiana Department of Environmental Quality Radiological Emergency Planning and Response Division P.O. Box 4312 Baton Rouge, LA 70821-4312 Louisiana Department of Environmental Quality Office of Environmental Compliance P.O. Box 4312 Baton Rouge, LA 70821-4312 Parish President Council St. Charles Parish P.O. Box 302 Hahnville, LA 70057 Chairman Louisiana Public Services Commission P.O. Box 91154 Baton Rouge, LA 70825-1697 Richard Penrod, Senior Environmental Scientist/State Liaison Officer Office of Environmental Services Northwestern State University Russell Hall, Room 201 Natchitoches, LA 71497 Resident Inspector Waterford NPS P.O. Box 822 Killona, LA 70057-0751 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011