MONTHYEARML0723302302007-08-23023 August 2007 Revised Pages of Facility Operating License DPR-28 B.5.b Project stage: Other ML0723302242007-08-23023 August 2007 Conforming License Amendment to Incorporate the Mitigation Strategies Required by Section B.5.b. of Commission Order EA-02-026 (Tac No. MD4566) Project stage: Other 2007-08-23
[Table View] |
|
---|
Category:License-Operating (New/Renewal/Amendments) DKT 50
MONTHYEARML19175A0422019-09-11011 September 2019 Arkansas Units 1 and 2; Grand Gulf, Unit 1; Indian Point 2 and 3; Palisades; River Bend, Unit 1; Waterford Unit 3 - Issuance of Amendments to Adopt TSTF-529, Clarify Use and Application Rules ML18347B3592019-01-11011 January 2019 12-13-18-License Transfer Conforming Amendment Markup ML18347B3602019-01-11011 January 2019 Letter: Vermont Yankee Nuclear Power Station - Issuance of Amendment Application for Order Approving Direct and Indirect Transfer of Renewed Facility Operating License and Independent Spent Fuel Storage Installation General License. ML18253A2022018-10-11011 October 2018 Conforming License Amendment Approval of License Transfer Request(License DPR-28, Docket 50-271 and 72-59) ML18156A1812018-08-15015 August 2018 ISFSI Only Tech Spec Amendment Package ML18165A4232018-07-25025 July 2018 Issuance of Amendment to Change the Physical Security Plan to Reflect an ISFSI-Only Configuration ML18053A1122018-03-30030 March 2018 Issuance of Amendment to Change the Emergency Plan and Emergency Action Level Scheme to Reflect an ISFSI-Only Configuration ML16014A1692016-03-14014 March 2016 Vermont Yankee Nuclear Power Station - Issuance of Amendment No. 265 to Renewed Facility Operating License Re: Cyber Security Plan Implementation Schedule (CAC No. MF6403) ML15233A1662015-12-11011 December 2015 Issuance of Amendment No. 264 to Renewed Facility Operating License Changes to the Emergency Plan and Emergency Action Levels ML15117A5512015-10-0707 October 2015 Issuance of Amendment for Defueled Technical Specifications and Revised License Conditions for Permanently Defueled Condition ML14304A5882015-02-12012 February 2015 Issuance of Amendment No. 261, Revise Technical Specifications to Eliminate Certain Requirements During Movement of Irradiated Fuel and Core Alterations Consistent with TSTF-51 ML14346A0652015-02-0404 February 2015 Issuance of Amendment No. 261, Revise Site Emergency Plan for Permanently Defueled Condition to Reflect Change in On-Shift Staffing and Emergency Response Staffing ML14217A0722014-12-22022 December 2014 Issuance of Amendment No. 260, Revise and Remove Certain Requirements from Technical Specification Section 6.0, Administrative Controls, No Longer Applicable for Its Permanently Defueled Condition ML14206A7102014-11-12012 November 2014 Issuance of Amendment No. 259, Revise Operating License Condition Related to Cyber Security Plan Milestone 8 Full Implementation Date ML13212A2012013-08-15015 August 2013 Issuance of Amendment No. 258 Change to Licensing Basis Regarding Station Blackout ML13105A1752013-04-26026 April 2013 Issuance of Amendment No. 257 Request to Revise Requirement of the Recirculation Pump Discharge Bypass Valves ML13042A2722013-04-17017 April 2013 Issuance of Amendment 256 Revision to License Condition 3.P and 3.S ML13025A3062013-03-14014 March 2013 ANO 1 & 2, Big Rock, FitzPatrick, GGNS, Indian Point 1, 2 & 3, Palisades, Pilgrim, RBS, Vermont Yankee, and Waterford - Correction to Amendments Issued on 12/28/12, Revise QA Program Manual and Staff Qualification Technical Specifications ML1300903212013-01-30030 January 2013 Issuance of Amendment Rod Worth Minimizer Bypass Allowance TS Change (TAC No. Me 7927) ML1300902152013-01-30030 January 2013 Issuance of Amendment Change to Suppression Chamber Drywell Leak Rate Test Surveillance Frequency ML12261A2922012-11-13013 November 2012 Issuance of Amendment to Renewed Facility Operating License Cyber Security Plan Implementation Schedule Milestone ML1127904592011-11-0404 November 2011 Issuance of Amendment Revised Reactor Vessel Pressure-Temperature Limitation Curves ML1127205902011-09-30030 September 2011 Issuance of Emergency Amendment Modification of Technical Specification for Single Loop Operation ML1121014312011-08-25025 August 2011 Issuance of Amendment Elimination of Technical Specification Provisions Allowing HPCI and RCIC Suctions to Be Aligned to the Suppression Pool ML11152A0132011-07-20020 July 2011 License Amendment, Cyber Security Plan ML0921100542011-03-21021 March 2011 Renewed Facility Operating License DPR-28 ML1103400782011-02-23023 February 2011 Issuance of Amendment Control Rod Block Actuation Logic System Functional Test ML1100601792011-02-0909 February 2011 Issuance of Amendment Regarding Modification to Technical Specification 4.12 as Result of Changes Made by License Amendment Nos. 230 and 239 and to Revise Wording in TS 3.7.A.8 ML1025717732010-10-0606 October 2010 License Amendment, Issuance of Amendment Scram Discharge Volume Vent and Drain Valves ML1004316132010-03-0808 March 2010 Issuance of Amendment Safety Limit Minimum Critical Power Ratio Change ML1001203062010-01-26026 January 2010 Issuance of Amendment Revision to Requirements for Inoperable Containment Isolation Valves ML0933604432010-01-0404 January 2010 License Amendment 241 Revision of High Radiation Area Controls ML0928906522009-10-28028 October 2009 Issuance of Amendment Extension of Appendix J, Type a Integrated Leakage Rate Test Interval ML0917400402009-07-13013 July 2009 License Amendment, Relocation of Reactor Building Crane Technical Specification ML0916102242009-07-0606 July 2009 Issuance of Amendment Testing and Inspection of Suppression Chamber-To-Drywell Vacuum Breakers ML0915505702009-06-17017 June 2009 License Amendment, Main Steam Isolation Valve Surveillance Requirements ML0914103582009-06-12012 June 2009 License Amendment, Issuance of Amendment Instrumentation Technical Specifications ML0903704562009-02-26026 February 2009 License Amendment, Issuance of Amendment Sale of Lease of Property within the Exclusion Boundary ML0901206582009-02-11011 February 2009 Issuance of Amendment Battery Systems ML0833001292009-01-0707 January 2009 Issuance of Amendment Control Rod Systems ML0815701872008-06-23023 June 2008 Issuance of Amendment Primary Containment Oxygen Concentration and Drywell-to-Suppression Chamber Differential Pressure Limits ML0808003342008-04-17017 April 2008 Issuance of Amendment Emergency Diesel Generator Fuel Oil Tank Volume, Fuel Oil Testing and Reactor Building Crane Inspections ML0723302302007-08-23023 August 2007 Revised Pages of Facility Operating License DPR-28 B.5.b ML0705301592007-03-26026 March 2007 Issuance of Amendment Adoption of Technical Specification Task Force (TSTF) Change TSTF-372, the Addition of Limiting Condition for Operation (LCO) 3.0.8 on the Inoperability of Snubbers ML0600500222006-03-0202 March 2006 Vermont Yankee, License Amendment 229 Regarding Extended Power Uprate ML0523600022005-09-20020 September 2005 License Amendment, Drywell Spray Header and Nozzle Air Test Frequency ML0520000032005-08-31031 August 2005 License Amendment, Revise One-Time Extension of Integrated Leak Rate Test Interval ML0519201382005-08-15015 August 2005 Issuance of License Amendment 226 Administrative Changes ML0516700622005-07-0707 July 2005 License Amendment, Extend Intermediate Range Monitor Surveillance Test Frequencies ML0504201652005-06-0101 June 2005 License Amendment, Relocation of Inservice Testing Requirements to a Licensee - Controlled Program 2019-09-11
[Table view] |
Text
ENCLOSURE 1 REVISED PAGES OF RENEWED FACILITY OPERATING LICENSE DPR-28 DOCKET NOS. 50-271 VERMONT YANKEE NUCLEAR POWER STATION Replace the following page of the Renewed Facility Operating License. The revised pages are identified by the date of the letter issuing these pages and contain marginal lines indicating the areas of change.
REMOVE INSERT Page 13 Page 13
Page 14
- 7. The requirements of paragraph 4 above for meeting the SDMP shall be implemented upon issuance of the EPU license amendment and shall continue until the completion of one full operating cycle at EPU. If an unacceptable structural flaw (due to fatigue) is detected during the subsequent visual inspection of the steam dryer, the requirements of paragraph 4 shall extend another full operating cycle until the visual inspection standard of no new flaws/flaw growth based on visual inspection is satisfied.
- 8. This license condition shall expire upon satisfaction of the requirements in paragraphs 5, 6, and 7 provided that a visual inspection of the steam dryer does not reveal any new unacceptable flaw or unacceptable flaw growth that is due to fatigue.
N. Mitigation Strategy License Condition Develop and maintain strategies for addressing large fires and explosions and that include the following key areas:
(a) Fire fighting response strategy with the following elements:
- 1. Pre-defined coordinated fire response strategy and guidance
- 2. Assessment of mutual aid fire fighting assets
- 3. Designated staging areas for equipment and materials
- 4. Command and control
- 5. Training of response personnel (b) Operations to mitigate fuel damage considering the following:
- 1. Protection and use of personnel assets
- 2. Communications
- 3. Minimizing fire spread
- 4. Procedures for implementing integrated fire response strategy
- 5. Identification of readily-available pre-staged equipment
- 6. Training on integrated fire response strategy
- 7. Spent fuel pool mitigation measures (c) Actions to minimize release to include consideration of:
- 1. Water spray scrubbing
- 2. Dose to onsite responders O. The licensee shall implement and maintain all Actions required by Attachment 2 to NRC Order EA-06-137, issued June 20, 2006, except the last action that requires incorporation of the strategies into the site security plan, contingency plan, emergency plan and/or guard training and qualification plan, as appropriate.
Amendment No. 208, 229 Revised by letter dated August 23, 2007
- 4. This license is effective as of the date of issuance and shall expire at midnight on A-127 12/17/90 March 21, 2012.
FOR THE ATOMIC ENERGY COMMISSION Original Signed By Roger S. Boyd /f/
A. Giambusso, Deputy Director for Reactor Projects Directorate of Licensing
Enclosures:
Appendix A Technical Specifications Date of Issuance:
Feb. 28, 1973 Amendment No. 208, 229 Revised by letter dated August 23, 2007