instrumentation and radiation monitoring equipment calibration, and as fission detectors in amounts as required; (4)

ENO pursuant to the Act and 10 CFR Parts 30, 40 and 70, Amdt. 42 to receive, possess, and use in amounts as required any 10-17-78 byproduct, source or special nuclear material without restriction to chemical or physical form, for sample analysis or instrument calibration or associated with radioactive apparatus or components; (5)

ENO pursuant to the Act and 10 CFR Parts 30 and 70, to Amdt. 220 possess, but not separate, such byproduct and special 09-06-01 nuclear materials as may be produced by the operation of the facility.

C. This amended license shall be deemed to contain and is subject to the conditions specified in the following Commission regulations in 10 CFR Chapter I: Part 20, Section 30.34 of Part 30, Section 40.41 of Part 40, Sections 50.54 and 50.59 of Part 50, and Section 70.32 of Part 70; is subject to all applicable provisions of the Act and to the rules, regulations, and orders of the Commission now or hereafter in effect; and is subject to the additional conditions specified or incorporated below:

(1) Maximum Power Level ENO is authorized to operate the facility at steady state Amdt. 241 reactor core power levels not in excess of 3216 10-27-04 megawatts thermal.

(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 252, are hereby incorporated in the license. ENO shall operate the facility in accordance with the Technical Specifications.

(3) The following conditions relate to the amendment approving the conversion to Improved Standard Technical Specifications:

1. This amendment authorizes the relocation of certain Technical Specification requirements and detailed information to licensee-controlled documents as described in Table R, "Relocated Technical Specifications from the CTS," and Table LA, "Removed Details and Less Restrictive Administrative Changes to the CTS" attached to the NRC staffs Safety Evaluation enclosed with this amendment. The relocation of requirements and detailed information shall be completed on or before the implementation of this amendment.

Amendment No. 252

- 5a -

3.

On the closing date of the transfer of the license, Con Edison shall transfer to ENIP2 all of the accumulated decommissioning trust funds for IP2 and such additional funds to be deposited in the decommissioning trust for IP2 such that the total amount transferred for Indian Point Nuclear Generating Unit No. 1 (IP1) and IP2 is no less than $430,000,000.

Furthermore, ENIP2 shall either (a) establish a provisional trust for decommissioning funding assurance for IP1 and IP2 in an amount no less than $25,000,000 (to be updated as required under applicable NRC regulations, unless otherwise approved by the NRC) or (b) obtain a surety bond for an amount no less than $25,000,000 (to be updated as required under applicable NRC regulations, unless otherwise approved by the NRC). The total decommissioning funding assurance provided for IP2 by the combination of the decommissioning trust and the provisional trust or surety bond at the time of transfer of the licenses shall be at a level no less than the amounts calculated pursuant to, and required under, 10 CFR 50.75. The decommissioning trust, provisional trust, and surety bond shall be subject to or be consistent with the following requirements, as applicable:

Amendment No. 252

Facility Operating License No. DPR-26 Appendix A - Technical Specifications TABLE OF CONTENTS 5.0 ADMINISTRATIVE CONTROLS 5.1 Responsibility 5.2 Organization 5.2.1 Onsite and Offsite Organizations 5.2.2 Unit Staff 5.3 Unit Staff Qualifications 5.4 Procedures 5.5 Programs And Manuals 5.5.1 Offsite Dose Calculation Manual (ODCM) 5.5.2 Primary Coolant Sources Outside Containment 5.5.3 Radioactive Effluent Controls Program 5.5.4 Component Cyclic or Transient Limit 5.5.5 Reactor Coolant Pump Flywheel Inspection Program 5.5.6 Inservice Testing Program 5.5.7 Steam Generator (SG) Program 5.5.8 Secondary Water Chemistry Program 5.5.9 Ventilation Filter Testing Program (VFTP) 5.5.10 Explosive Gas and Storage Tank Radioactivity Monitoring Program 5.5.11 Diesel Fuel Oil Testing Program 5.5.12 Technical Specification (TS) Bases Control Program 5.5.13 Safety Function Determination Program (SFDP) 5.5.14 Containment Leakage Rate Testing Program 5.5.15 Battery Monitoring and Maintenance Program 5.6 Reporting Requirements 5.6.1 Not Used 5.6.2 Annual Radiological Environmental Operating Report 5.6.3 Radioactive Effluent Release Report 5.6.4 Not Used 5.6.5 CORE OPERATING LIMITS REPORT (COLR) 5.6.6 Post Accident Monitoring Report 5.6.7 Steam Generator Tube Inspection Report 5.7 High Radiation Area Indian Point 2 iv Amendment No. 252 Indian Point 2 iv Amendment No. 252

Frequency 1.4 1.4 Frequency EXAMPLES (continued)

EXAMPLE 1.4-1 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY Perform CHANNEL CHECK.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Example 1.4-1 contains the type of SR most often encountered in the Technical Specifications (TS).

The Frequency specifies an interval (12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />) during which the associated Surveillance must be performed at least one time. Performance of the Surveillance initiates the subsequent interval. Although the Frequency is stated as 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, an extension of the time interval to 1.25 times the stated Frequency is allowed by SR 3.0.2 for operational flexibility. The measurement of this interval continues at all times, even when the SR is not required to be met per SR 3.0.1 (such as when the equipment is inoperable, a variable is outside specified limits, or the unit is outside the Applicability of the LCO). If the interval specified by SR 3.0.2 is exceeded while the unit is in a MODE or other specified condition in the Applicability of the LCO, and the performance of the Surveillance is not otherwise modified (refer to Example 1.4-3), then SR 3.0.3 becomes applicable.

If the interval as specified by SR 3.0.2 is exceeded while the unit is not in a MODE or other specified condition in the Applicability of the LCO for which performance of the SR is required, then SR 3.0.4 becomes applicable. The Surveillance must be performed within the Frequency requirements of SR 3.0.2, as modified by SR 3.0.3, prior to entry into the MODE or other specified condition or the LCO is considered not met (in accordance with SR 3.0.1) and LCO 3.0.4 becomes applicable.

INDIAN POINT 2 1.4-3 Amendment No. 252

RPS Instrumentation 3.3.1 Table 3.3.1-1 (page 5 of 6)

Reactor Protection System Instrumentation Note 1: Overtemperature AT The Overtemperature AT Function Allowable Value shall not exceed the following:

The channel's maximum trip setpoint shall not exceed its computed trip setpoint by more than 4.9% AT span.

ATAT{K-K (1+

S)[T-T']+K,(P-P,).fi(Ai)}

AT<_*T,,K,-K(I+

r;S)

Where:

AT is measured RCS AT, OF (measured by hot leg and cold leg RTDs).

AT0 is the loop specific indicated AT at RTP, OF.

s is the Laplace transform operator, sec-1.

T is the measured RCS average temperature, °F.

T' is the loop specific indicated Tvg at RTP, _ [*]IF.

P is the measured pressurizer pressure, psig P' is the nominal RCS operating pressure, > [*] psig K1 < [*]

K2 > [*]/OF K3 >- [*]/psig Tri

[*]sec T2

[*]sec f1(AI) =

[*] {[*]- (qt - qb)}

when qt - qb < [*]% RTP 0% of RTP when [*]% RTP < qt - qb < [*]% RTP

[*] {(qt - qb) - [*]}

when qt - qb > [*]% RTP Where qt and qb are percent RTP in the upper and lower halves of the core, respectively, and qt + qb is the total THERMAL POWER in percent RTP.

  • These values denoted with [*] are specified in the COLR.

INDIAN POINT 2 3.3.1 - 16 Amendment No. 252

RPS Instrumentation 3.3.1 Table 3.3.1-1 (page 6 of 6)

Reactor Protection System Instrumentation Note 2: Overpower AT The Overpower AT Function Allowable Value shall not exceed the following:

The channel's maximum trip setpoint shall not exceed its computed trip setpoint by more than 2.4% AT span.

AT <ATo K,-K 5 ( IrS) r-K,(T f2(AI Where:

AT is measured RCS AT,°F.

AT0 is the loop specific indicated AT at RTP, OF.

s is the Laplace transform operator, sec-1.

T is the measured RCS average temperature, OF.

T" is the loop specific indicated Tavg at RTP, < [*]°F.

K4 < [*M K5 Ž [*]/OF for increasing Tavg K6 z [*]/OF when T > T"

[*]/OF for decreasing Tavg

[*]/OF when T.- T T3 > [] sec f2(AI) = [*]

  • These values denoted with [*] are specified in the COLR.

INDIAN POINT 2 3.3.1 - 17 Amendment No. 252

CRVS Actuation Instrumentation 3.3.7 Table 3.3.7-1 (page 1 of 1)

CRVS Actuation Instrumentation CHANNELS SURVEILLANCE FUNCTION REQUIRED CHANNELS ALLOWABLE VALUES REQUIREMENTS

1.

Manual Initiation I train SR 3.3.7.4 NA

2.

Control Building Air Intake 1

SR 3.3.7.1

_0.75 mr/hr Radiation (R-38-1)

SR 3.3.7.2 SR 3.3.7.3 SR 3.3.7.5

3.

Control Room Air Intake SR 3.3.7.1

< 0.75 mr/hr Radiation (R-38-2)

SR 3.3.7.2 SR 3.3.7.3 SR 3.3.7.5

4.

Safety Injection Refer to LCO 3.3.2, "ESFAS Instrumentation," Function 1, for all initiation functions and requirements.

INDIAN POINT 2 3.3.7-3 Amendment No. 252

Unit Staff Qualifications 5.3 5.0 ADMINISTRATIVE CONTROLS 5.3 Unit Staff Qualifications 5.3.1 Each member of the unit staff shall meet or exceed the minimum qualifications of ANSI/ANS 3.1-1978 for comparable positions, except for the following:

a.

The radiation protection manager shall meet or exceed the qualifications of Regulatory Guide 1.8, September 1975; and

b.

The operations manager shall meet or exceed the minimum qualifications of ANSI/ANS 3.1-1978 except for the SRO license requirement which shall be in accordance with Technical Specification 5.2.2.e.

5.3.2 For the purpose of 10 CFR 55.4, a licensed Senior Reactor Operator (SRO) and a licensed reactor operator (RO) are those individuals who, in addition to meeting the requirements of TS 5.3.1, perform the functions described in 10 CFR 50.54(m).

INDIAN POINT 2 5.3-1 Amendment No. 252

Programs and Manuals 5.5 5.5 Programs and Manuals 5.5.13 Safety Function Determination Program (SFDP) (continued)

The SFDP identifies where a loss of safety function exists. If a loss of safety function is determined to exist by this program, the appropriate Conditions and Required Actions of the LCO in which the loss of safety function exists are required to be entered. When a loss of safety function is caused by the inoperability of a single Technical Specification support system, the appropriate Conditions and Required Actions to enter are those of the support system.

5.5.14 Containment Leakage Rate Testinq Program

a.

A program shall establish the leakage rate testing of the containment as required by 10 CFR 50.54(o) and 10 CFR 50, Appendix J, Option B, as modified by approved exemptions. This program shall be in accordance with the guidelines contained in Regulatory Guide 1.163, "Performance-Based Containment Leak-Test Program," dated September, 1995.

b.

The calculated peak containment internal pressure for the design basis loss of coolant accident, Pa, is assumed to be the containment design pressure of 47 psig.

c.

The maximum allowable containment leakage rate, La, at Pa, and 271°F shall be 0.1% of containment steam air weight per day.

d.

Leakage rate acceptance criteria:

1.

Containment leakage rate acceptance criterion is 1.0 La. During the first unit startup following testing in accordance with this program, the leakage rate acceptance criteria are < 0.60 La for the Type B and C tests and < 0.75 La for Type A tests.

2.

Air lock testing acceptance criteria shall be established to ensure that limits for Type B and C testing in Technical Specification 5.5.14.d.1 are met.

INDIAN POINT 2 5.5 -14 Amendment No. 252

  • (4)

ENO pursuant to the Act and 10 CER Parts 30, 40 and 70, Amndt. 203 to receive, possess, and use in amounts as required any 11/27/00 byproduct, source or special nuclear material without restriction to chemical or physical form, for sample analysis or instrument calibration or associated with radioactive apparatus or components; (5)

ENO pursuant to the Act and 10 CFR Parts 30 and 70, to Amndt. 203 possess, but not separate, such byproduct and special 11/27/00 nuclear materials as may be produced by the operation of the facility.

C.

This amended license shall be deemed to contain and is subject to the conditions specified in the following Commission regulations in 10 CFR Chapter 1: Part 20, Section 30.34 of Part 30, Section 40.41 of Part 40, Sections 50.54 and 50.59 of Part 50, and Section 70.32 of Part 70; and is subject to all applicable provisions of the Act and to the rules, regulations, and orders of the Commission now or hereafter in effect; and is subject to the additional conditions specified or incorporated below:

(1)

Maximum Power Level ENO is authorized to operate the facility at steady state reactor core power levels not in excess of 3216 megawatts thermal (100% of rated power).

(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 234, are hereby incorporated in the License. ENO shall operate the facility in accordance with the Technical Specifications.

(3)

(DELETED)

Amdt. 205 2-27-01 (4)

(DELETED)

Amdt. 205 2-27-01 D.

(DELETED)

Amdt.46 2-16-83, E.

(DELETED)

Amdt.37 5-14-8 1 F.

This amended license is also subject to appropriate conditions by the New York State Department of Environmental Conservation in its letter of May 2, 1975, to Consolidated Edison Company of New York, Inc., granting a Section 401 certification under the Federal Water Pollution Control Act Amendments of 1972.

Amendment No. 234

Frequency 1.4 1.4 Frequency EXAMPLES EXAMPLE 1.4-1 (continued)

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY Perform CHANNEL CHECK.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Example 1.4-1 contains the type of SR most often encountered in the Technical Specifications (TS).

The Frequency specifies an interval (12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />) during which the associated Surveillance must be performed at least one time.

Performance of the Surveillance initiates the subsequent interval.

Although the Frequency is stated as 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, an extension of the time interval to 1.25 times the stated Frequency is allowed by SR 3.0.2 for operational flexibility.

The measurement of this interval continues at all times, even when the SR is not required to be met per SR 3.0.1 (such as when the equipment is inoperable, a variable is outside specified limits, or the unit is outside the Applicability of the LCO).

If the interval specified by SR 3.0.2 is exceeded while the unit is in a MODE or other specified condition in the Applicability of the LCO, and the performance of the Surveillance is not otherwise modified (refer to Example 1.4-3), then SR 3.0.3 becomes applicable.

If the interval as specified by SR 3.0.2 is exceeded while the unit is not in a MODE or other specified condition in the Applicability of the LCO for which performance of the SR is required, then SR 3.0.4 becomes applicable.

The Surveillance must be performed within the Frequency requirements of SR 3.0.2, as modified by SR 3.0.3, prior to entry into the MODE or other specified condition or the LCO is considered not met (in accordance with SR 3.0.1) and LCO 3.0.4 becomes applicable.

(continued)

INDIAN POINT 3 1.4-2 Amendment 234

RPS Instrumentation 3.3.1 Table 3.3.1-1 (page 7 of 8)

Reactor Protection System Instrumentation Note 1:

Overtemperature AT The Overtemperature AT Function Allowable Value shall not exceed the following Trip Setpoint by more than 2.8% of AT span:

AT!5 A To{ Ki-K(1+

1) [T-T']+K,(P-P')-f,(A I)

(1 + r,2 S)

Where:

AT is measured RCS AT, IF.

AT, is the indicated AT at RTP, OF.

s is the Laplace transform operator, sec'.

T is the measured RCS average temperature, OF.

T' is the nominal Tvg at RTP, * [ * ]OF.

P is the measured pressurizer pressure, psig P' is the nominal RCS operating pressure, Ž [ * ] psig K1 < [*]

, >- [ * ] sec K2

[

  • F T2

[*]

sec K3 Ž I * ]/psig f 1(AI)

=

[ * ] ([ * ]

(q qb)}

0% of RTP

[ * ] {(qt qb)

[ *%)

when when when qt-qb -< [ *

[ * ]% RTP<

qt-qb > [

] % RTP qt - q

  • 1%

RTP

]% RTP Where q, and q, are percent RTP core, respectively, and q, + qb percent RTP.

in the upper and lower halves of the is the total THERMAL POWER in The values denoted with [ * ] are specified in the COLR.

INDIAN POINT 3 3.3.1-19 Amendment 234

RPS Instrumentation 3.3.1 Table 3.3.1-1 (page 8 of 8)

Reactor Protection System Instrumentation Note 2:

Overpower AT The Overpower AT Function Allowable Value shall not exceed the following Trip Setpoint by more than 1.8% of AT span:

AT <ATo K4 -K5 (I T -K 6 (T-T")-f 2 (AI)

Where:

AT is measured RCS AT, °F.

ATo is the indicated AT at RTP, OF.

s is the Laplace transform operator, secI.

T is the measured RCS average temperature, OF.

T" is the nominal T.vg at RTP,

_< [ * ]F.

K4 < [ * ]

K5 _ [ * ] /'F for increasing Tavg K6 _ [ * ] /OF when T > T'

[ * ] /'F for decreasing Tavg

[ * ] /'F when T _< T" T3 Ž[* ] sec f,(Al) = [ * ]

  • The values denoted with [ * ] are specified in the COLR.

INDIAN POINT 3 3.3.1-20 Amendment 234

CRVS 3.7.11 3.7 PLANT SYSTEMS 3.7.11 Control Roan Ventilation Systen (CRVS)

LCO 3.7.11 Two CRVS trains shall be OPERABLE.

APPLICABILITY:

ACTIONS MODES 1, 2, 3, 4.

CONDITION REQUIRED ACTION COMfLETION TIME A.

One CRVS train inoperable.

A.1 Restore CRVS train to 7 days OPERABLE status.

B.

Two CRVS trains inoperable.

B.1 Restore one CRVS train to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> OPERABLE status.

C.

Required Action and C.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Cacpletion Time of Condition A or B not met.

AND C.2 Be in MODE 5.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> INDIAN POINT 3 3.7.11-1 Amendment 234

Inverters - Operating 3.8.7ý SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.8.7.1 Verify correct inverter voltage, frequency, 7 days and alignment to required 120V AC vital instrument buses.

SR 3.8.7.2 Verify manual transfer of the AC power source 24 months for VIB 34 from inverter 34 to each required CVT.

INDIAN POINT 3 3.8.7 - 3 Amendment 234

Unit Staff Qualifications 5.3 5.0 ADMINISTRATIVE CONTROLS 5.3 Unit Staff Qualifications 5.3.1 Each member of the unit staff shall meet or exceed the minimum qualifications of ANSI/ANS 3.1-1978 for comparable positions, except for the following:

a.

The radiation protection manager shall meet or exceed the qualifications of Regulatory Guide 1.8, September 1975; and

b.

The operations manager shall meet or exceed the minimum qualifications of ANSI/ANS 3.1-1978 except for the SRO license requirement which shall be in accordance with Technical Specification 5.2.2.e.

5.3.2 For the purpose of 10 CFR 55.4, a licensed Senior Reactor Operator (SRO) and a licensed Reactor Operator (RO) are those individuals who, in addition to meeting the requirements of TS 5.3.1, perform the functions described in 10 CFR 50.54(m).

INDIAN POINT 3 5.0 - 5 Amendment 234

Procedures 5.4 5.0 ADMINISTRATIVE CONTROLS 5.4 Procedures 5.4.1 Written procedures shall be established, implemented, and maintained covering the following activities:

a.

The applicable procedures recommended in Regulatory Guide 1.33, Revision 2, Appendix A, February 1978;

b.

The emergency operating procedures required to implement the requirements of NUREG-0737 and to NUREG-0737, Supplement 1, as stated in Generic Letter 82-33;

c.

Quality assurance for effluent and environmental monitoring;

d.

Fire Protection Program implementation; and

e.

All programs specified in Specification 5.5.

INDIAN POINT 3 5.0-6 Amendment 234

Programs and Manuals 5.5 5.5 Programs and Manuals 5.5.10 Ventilation Filter Testing Program (VFTP)

(continued)

c.

Demonstrate for each system that a laboratory test of a sample of the charcoal adsorber shows the methyl iodide removal efficiency specified below when tested in accordance with ASTM D3803-1989, subject to clarification below, at a temperature of 860F and a relative humidity of 95%.

Methyl iodide removal ASTM D3803-1989 Ventilation System efficiency Clarification Control Room

> 95.5 78 ft/min face velocity Ventilation System Containment Fan Cooler

> 85 59 ft/min face velocity Units (conti nued)

INDIAN POINT 3 5.0 - 24 Amendment 234

Programs and Manuals 5.5 5.5 Programs and Manuals 5.5.15 Containment Leakage Rate Testing Program A program shall be established to implement the leakage rate testing of the containment as required by 10 CFR 50.54(o) and 10 CFR 50, Appendix J, Option B, as modified by approved exemptions.

This program shall be in accordance with the guidelines contained in Regulatory Guide 1.163, "Performance-Based Containment Leak Test Program, dated September 1995" as modified by the following exception:

ANS 56.8-1994, Section 3.3.1: WCCPPS isolation valves are not Type C tested.

The maximum allowable primary containment leakage rate, La, at a minimum test pressure equal to Pa, shall be 0.1% of primary containment air weight per day.

Pa is the peak calculated containment internal pressure related to the design basis accident.

Leakage acceptance criteria are:

a.

Containment leakage rate acceptance criterion is < 1.0 L8.

During the first unit startup following testing in accordance with this program, the leakage rate acceptance criteria are < 0.60 La for the Type B and C tests and < 0.75 La for Type A tests;

b.

Air lock testing acceptance criteria are:

1) Overall air lock leakage rate is

< 0.05 La when tested at > Pa,

2)

For each door, leakage rate is < 0.01 La when pressurized to > Pa,

c.

Isolation Valve Seal Water System leakage rate acceptance criterion is 14,700 cc/hr at > 1.1 Pa'

d.

Acceptance criterion for leakage into containment from isolation valves sealed with the service water system is

< 0.36 gpm per fan (continued)

INDIAN POINT 3 5.0 - 30 Amendment 234