ML072280001

From kanterella
Jump to navigation Jump to search

Environmental Assessment and Finding of No Significant Impact for Proposed License Amendment and Exemption from 10 CFR 50.46 and Appendix K - Use of Optimized Zirlo Fuel Rod Cladding
ML072280001
Person / Time
Site: Waterford 
(NPF-038)
Issue date: 09/25/2007
From: Kalyanam N
NRC/NRR/ADRO/DORL/LPLIV
To: Walsh K
Entergy Operations
Kalyanam N, NRR/DORL/LP4, 415-1480
References
TAC MD5426
Download: ML072280001 (7)


Text

September 25, 2007 Mr. Kevin T. Walsh Vice President of Operations Entergy Operations, Inc.

17265 River Road Killona, LA 70057-3093

SUBJECT:

WATERFORD STEAM ELECTRIC STATION, UNIT 3 (WATERFORD 3)-

ENVIRONMENTAL ASSESSMENT AND FINDING OF NO SIGNIFICANT IMPACT FOR EXEMPTIONS FROM 10 CFR 50.46 AND APPENDIX K - USE OF OPTIMIZED ZIRLOTM FUEL ROD CLADDING (TAC NO. MD5426)

Dear Mr. Walsh:

Enclosed is a copy of the Environmental Assessment and Finding of No Significant Impact related to your application for an exemption dates April 24, 2007. The proposed exemption would exempt Waterford 3 from the requirements of Title 10 of the Code of Federal Regulations, Section 50.46 and Appendix K.

The assessment is being forwarded to the Office of the Federal Register for publication.

Sincerely,

/RA/

N. Kalyanam, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-382

Enclosure:

Environmental Assessment cc w/encl: See next page

ML072280001

  • submitted by memo dated July 9, 2007, ** No Legal Objection OFFICE NRR/LPL4/PM NRR/LPL4/LA REBA/BC OGC**

NRR/LPL4/BC NAME NKalyanam JBurkhardt EBenner MSmith THiltz DATE 8/27/07 8/27/07 07/09/07*

9/21/07 9/25/07

Waterford Steam Electric Station, Unit 3 cc:

Vice President, Operations Support Entergy Operations, Inc.

P.O. Box 31995 Jackson, MS 39286-1995 Ms. Kimberly S. Cook, Director Nuclear Safety Assurance Entergy Operations, Inc.

17265 River Road Killona, LA 70057-0751 Mr. Joe Kowalewski General Manager, Plant Operations Waterford Steam Electric Station, Unit 3 Entergy Operations, Inc.

17265 River Road Killona, LA 70057-0751 Manager, Licensing Entergy Operations, Inc.

17265 River Road Killona, LA 70057-0751 Resident Inspector Waterford NPS P.O. Box 822 Killona, LA 70057-0751 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011 Parish President Council St. Charles Parish P.O. Box 302 Hahnville, LA 70057 Mr. Jeff Forbes Senior Vice President and Chief Operating Officer Entergy Operations, Inc.

P.O. Box 31995 Jackson, MS 39286-1995 Mr. John McCann Director, Nuclear Safety & Licensing Entergy Services, Inc.

440 Hamilton Avenue White Plains, NY 10601 Louisiana Department of Environmental Quality Radiological Emergency Planning and Response Division P.O. Box 4312 Baton Rouge, LA 70821-4312 Louisiana Department of Environmental Quality Office of Environmental Compliance P.O. Box 4312 Baton Rouge, LA 70821-4312 Chairman Louisiana Public Services Commission P.O. Box 91154 Baton Rouge, LA 70825-1697 Richard Penrod, Senior Environmental Scientist/State Liaison Officer Office of Environmental Services Northwestern State University Russell Hall, Room 201 Natchitoches, LA 71497 7590-01-P UNITED STATES NUCLEAR REGULATORY COMMISSION ENTERGY OPERATIONS INC.

WATERFORD STEAM ELECTRIC STATION, UNIT 3 ENVIRONMENTAL ASSESSMENT AND FINDING OF NO SIGNIFICANT IMPACT DOCKET NO. 50-382 The U.S. Nuclear Regulatory Commission (NRC) is considering issuance of exemptions from Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Section 50.46 and Appendix K, for Facility Operating License No. NPF-38, issued to Entergy Operations, Inc.

(Entergy, the licensee), for operation of the Waterford Steam Electric Station, Unit 3 (Waterford 3), located in St. Charles Parish, Louisiana. Therefore, as required by 10 CFR 51.21, the NRC is issuing this environmental assessment and finding of no significant impact.

ENVIRONMENTAL ASSESSMENT Identification of the Proposed Action:

The proposed action would exempt the licensee from the requirements of 10 CFR Part 50, Section 50.46 and Appendix K to allow the use of Optimized ZIRLOTM fuel rod cladding as the allowable fuel rod cladding material. The proposed action is in accordance with Entergys application dated April 24, 2007.

The Need for the Proposed Action:

The NRCs regulations in 10 CFR Part 50, Section 50.46 and Appendix K, make no provision for use of fuel rod clad in a material other than Zircaloy or ZIRLOTM. Optimized ZIRLOTM has a lower tin content than either Zircaloy or ZIRLOTM; therefore, use of Optimized ZIRLOTM fuel rod clad calls for an exemption from 10 CFR Part 50, Section 50.46 and Appendix K.

For cladding with a lower tin content, corrosive resistance has been found to improve, as indicated by available industry data from the American Nuclear Society, the International Atomic Energy Agency, the Electric Power Research Institute, and Westinghouse Electric Corporation.

The optimum tin level provides a reduced corrosion rate while maintaining the benefits of mechanical strength and resistance to accelerated corrosion from abnormal chemistry conditions. In addition, fuel rod internal pressures (resulting from increased fuel duty, use of integral fuel burnable absorbers and corrosion/temperature feedback effects) have become more limiting with respect to fuel rod design criteria. Reducing the associated corrosion buildup, and thus, minimizing temperature feedback effects, provides additional margin to fuel rod internal pressure design criteria. The NRC previously granted a similar exemption in July 2004 for Waterford 3 for use of Optimized ZIRLOTM in four lead-test assemblies.

Environmental Impacts of the Proposed Action:

The NRC staff has completed its safety evaluation of the proposed action and concludes that the proposed exemptions would continue to satisfy the underlying purpose of 10 CFR Part 50, Sections 50.46 and Appendix K, and will not increase the probability or consequences of accidents previously analyzed and would not affect facility radiation levels or facility radiological effluents.

The details of the staffs safety evaluation will be provided in the exemption that will be issued as part of the letter to the licensee approving the amendment to the regulation.

The proposed action will not significantly increase the probability or consequences of accidents. No changes are being made in the types of effluents that may be released off site.

There is no significant increase in the amount of any effluent released off site. There is no significant increase in occupational or public radiation exposure. Therefore, there are no significant radiological environmental impacts associated with the proposed action.

With regard to potential non-radiological impacts, the proposed action does not have a potential to affect any historic sites. It does not affect non-radiological plant effluents and has no other environmental impact. Therefore, there are no significant non-radiological environmental impacts associated with the proposed action.

Accordingly, the NRC concludes that there are no significant environmental impacts associated with the proposed action.

Environmental Impacts of the Alternatives to the Proposed Action:

As an alternative to the proposed action, the staff considered denial of the proposed action (i.e., the no-action alternative). Denial of the application would result in no change in current environmental impacts. The environmental impacts of the proposed action and the no-action alternative are similar.

Alternative Use of Resources:

The action does not involve the use of any different resources than those previously considered in the Final Environmental Statement for Waterford 3, dated September 1981.

Agencies and Persons Consulted:

In accordance with its stated policy, on August 17, 2007, the staff consulted with the Louisiana State official, Ms. Nan Calhoun of the Louisiana Department of Environmental Quality, regarding the environmental impact of the proposed action. The State official had no comments.

FINDING OF NO SIGNIFICANT IMPACT On the basis of the environmental assessment, the NRC concludes that the proposed action will not have a significant effect on the quality of the human environment. Accordingly, the NRC has determined not to prepare an environmental impact statement for the proposed action.

For further details with respect to the proposed action, see the licensees letter dated April 24, 2007. Documents may be examined, and/or copied for a fee, at the NRCs Public Document Room (PDR), located at One White Flint North, Public File Area O1F21, 1555 Rockville Pike (first floor), Rockville, Maryland. Publicly available records will be accessible electronically from the Agencywide Documents Access and Management System (ADAMS) Public Electronic Reading Room on the Internet at the NRC Website:

http://www.nrc.gov/reading-rm/adams.html. Persons who do not have access to ADAMS or who encounter problems in accessing the documents located in ADAMS should contact the NRC PDR Reference staff by telephone at 1-800-397-4209 or 301-415-4737, or send an email to pdr@nrc.gov.

Date at Rockville, Maryland, this 25th day of September 2007.

FOR THE NUCLEAR REGULATORY COMMISSION

/RA/

Nageswaran Kalyanam, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation