ML072220363

From kanterella
Jump to navigation Jump to search

University of Missouri at Columbia - Request for Additional Information License Amendment on Fueled Experiment Conditions (TAC MD 5782)
ML072220363
Person / Time
Site: University of Missouri-Columbia
Issue date: 08/10/2007
From: Alexander Adams
NRC/NRR/ADRA/DPR/PRTA
To: Rhonda Butler
Univ of Missouri - Columbia
Adams A, NRC/NRR/DPR/PRT, 415-1127
References
TAC MD5782
Download: ML072220363 (5)


Text

August 10, 2007 Mr. Ralph Butler, Director Research Reactor Center University of Missouri-Columbia Research Park Columbia, MO 65211

SUBJECT:

UNIVERSITY OF MISSOURI AT COLUMBIA REQUEST FOR ADDITIONAL INFORMATION RE: LICENSE AMENDMENT ON FUELED EXPERIMENT CONDITIONS (TAC NO. MD5782)

Dear Mr. Butler:

We are continuing our review of your amendment request for Amended Facility License No. R-103 for the University of Missouri - Columbia Research Reactor which you submitted on June 8, 2007. During our review of your amendment request, questions have arisen for which we require additional information and clarification. Please provide responses to the enclosed request for additional information within 90 days of the date of this letter. In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation.

Following receipt of the additional information, we will continue our evaluation of your amendment request.

If you have any questions regarding this review, please contact me at (301) 415-1127.

Sincerely,

/RA/

Alexander Adams, Jr., Senior Project Manager Research and Test Reactors Branch A Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-186

Enclosure:

As stated cc w/enclosure:

See next page

University of Missouri-Columbia Docket No. 50-186 cc:

University of Missouri Associate Director Research Reactor Facility Columbia, MO 65201 Homeland Security Coordinator Missouri Office of Homeland Security P.O. Box 749 Jefferson City, MO 65102 Planner, Dept of Health and Senior Services Section for Environmental Public Health 930 Wildwood Drive, P.O. Box 570 Jefferson City, MO 65102-0570 Deputy Director for Policy Department of Natural Resources 1101 Riverside Drive Fourth Floor East Jefferson City, MO 65101 A-95 Coordinator Division of Planning Office of Administration P.O. Box 809, State Capitol Building Jefferson City, MO 65101 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611

August 10, 2007 Mr. Ralph Butler, Director Research Reactor Center University of Missouri-Columbia Research Park Columbia, MO 65211

SUBJECT:

UNIVERSITY OF MISSOURI AT COLUMBIA REQUEST FOR ADDITIONAL INFORMATION RE: LICENSE AMENDMENT ON FUELED EXPERIMENT CONDITIONS (TAC NO. MD5782)

Dear Mr. Butler:

We are continuing our review of your amendment request for Amended Facility License No. R-103 for the University of Missouri - Columbia Research Reactor which you submitted on June 8, 2007. During our review of your amendment request, questions have arisen for which we require additional information and clarification. Please provide responses to the enclosed request for additional information within 90 days of the date of this letter. In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation.

Following receipt of the additional information, we will continue our evaluation of your amendment request.

If you have any questions regarding this review, please contact me at (301) 415-1127.

Sincerely,

/RA/

Alexander Adams, Jr., Senior Project Manager Research and Test Reactors Branch A Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-186

Enclosure:

As stated cc w/enclosure:

See next page DISTRIBUTION:

Public RidsNrrDpr RidsNrrDprPrta RTR r/f RidsNrrDprPrtb ADAMS Accession Number: ML072220363 Office PRTA:LA PRTA:PM PRTA:SC Name EHylton egh AAdams aa DCollins dsc Date 8/10/07 8/10/07 8/10/07

REQUEST FOR ADDITIONAL INFORMATION UNIVERSITY OF MISSOURI RESEARCH REACTOR DOCKET NO. 50-186 The following questions are asked to determine compliance with the regulations in 10 CFR Part 20, Standards for Protection Against Radiation.

1.

Please provide a detailed analysis with justification of assumptions of the radiological impact to persons in the reactor containment and members of the public from a failure of the fueled experiment irradiation container. While your proposed technical specification (TS) is based on certain iodine and strontium isotopes, please base your calculations on all isotopes that are likely to be released from the failed irradiation container.

2.

How would failure of a fueled experiment be detected? What is the sensitivity of the radiation detection equipment? What actions, both automatic and operator initiated would be taken in response to an experiment failure?

3.

Will the target processing be conducted under the reactor license? If so, describe the facilities that will be used. Describe how radioactive material will be controlled during target processing. Describe possible accident scenarios and the potential radiological impact of the scenarios.

The following question is asked to determine compliance with the conditions of your reactor license.

4.

License condition 2.B.(2) allows you to possess, but not separate, such special nuclear material as may be produced by the operation of the facility.... Please describe the complete processing that the irradiated uranium targets will undergo. Explain how license condition 2.B.(2) is met during this process.

Enclosure