UHS 3.7.3 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.7.3.1 Verify cooling water temperature supplied 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> to the plant from the CSCS pond is 1011.25°F.

SR 3.7.3.2 Verify sediment level is

  • 1.5 ft in the 24 months intake flume and the CSCS pond.

SR 3.7.3.3 Verify CSCS pond bottom elevation is 24 months 686.5 ft.

LaSalle I and 2 3.7.3-2 Amendment No. 183 / 170