ENCLOSURE 1 REVISED PAGES OF FACILITY OPERATING LICENSE NO. NPF-42 DOCKET NO. 50-482 Replace the following pages of the Facility Operating License No. NPF-42. The revised pages are identified by the date of the letter issuing these pages and contain marginal lines indicating the areas of change.

Facility Operating License REMOVE INSERT 5

5 6

6 7

(7)

NUREG-0737 Supplement 1 Conditions (Section 22, SER)

Deleted per Amendment No. 141.

(8)

Post-Fuel-Loading Initial Test Program (Section 14, SER Section 14, SSER #5)

Deleted per Amendment No. 141.

(9)

Inservice Inspection Program (Sections 5.2.4 and 6.6, SER)

Deleted per Amendment No. 141.

(10)

Emergency Planning Deleted per Amendment No. 141.

(11)

Steam Generator Tube Rupture (Section 15.4.4, SSER #5)

Deleted per Amendment No. 141.

(12)

LOCA Reanalysis (Section 15.3.7, SSER #5)

Deleted per Amendment No. 141.

(13)

Generic Letter 83-28 Deleted per Amendment No. 141.

(14)

Surveillance of Hafnium Control Rods (Section 4.2.3.1 (10), SER and SSER #2)

Deleted per Amendment No. 141.

(15)

Mitigation Strategy l

Develop and maintain strategies for addressing large fires and explosions that l

include the following key areas:

l l

(a)

Fire fighting response strategy with the following elements:

l

1. Pre-defined coordinated fire response strategy and guidance l
2. Assessment of mutual aide fire fighting assets l
3. Designated staging areas for equipment and materials l
4. Command and control l
5. Training of response personnel l

Amendment No. 4, 108, 141 Revised by letter dated August 2, 2007 (b)

Operations to mitigate fuel damage considering the following:

l

1. Protection and use of personnel assets l
2. Communications l
3. Minimizing fire spread l
4. Procedures for implementing integrated fire response strategy l
5. Identification of readily available, pre-staged equipment l
6. Training on integrated fire response strategy l
7. Spent fuel pool mitigation measures l

(c)

Actions to minimize release to include consideration of:

l

1. Water spray scrubbing l
2. Dose to onsite responders l

(16)

Additional Conditions l

The Additional Conditions contained in Appendix D, as revised through Amendment No. 163, are hereby incorporated into this license. Wolf Creek Nuclear Operating Corporation shall operate the facility in Accordance with the Additional Conditions.

D.

Exemptions from certain requirements of Appendix J to 10 CFR Part 50, and from a portion of the requirements of General Design Criterion 4 of Appendix A to 10 CFR Part 50, are described in the Safety Evaluation Report. These exemptions are authorized by law and will not endanger life or property or the common defense and security and are otherwise in the public interest. Therefore, these exemptions are hereby granted pursuant to 10 CFR 50.12. With the granting of these exemptions the facility will operate, to the extent authorized herein, in conformity with the application, as amended, the provisions of the Act, and the rules and regulations of the Commission.

E.

The licensee shall fully implement and maintain in effect all provisions of the Commission-approved physical security, training and qualification, and safeguards contingency plans including amendments made pursuant to provisions of the Miscellaneous Amendments and Search Requirements revisions to 10 CFR 73.55 (51 FR 27817 and 27822) and to the authority of 10 CFR 50.90 and 10 CFR 50.54(p). The set of combined plans, which contains Safeguards Information protected under 10 CFR 73.21, is entitled: Wolf Creek Security Plan, Training and Qualification Plan, and Safeguard Contingency Plan, and was submitted on May 17, 2006.

Amendment No. 4, 108, 141, 163 Revised by letter dated October 28, 2004 Revised by letter dated February 13, 2007 Revised by letter dated August 2, 2007 l

F.

Deleted per Amendment No. 141.

G.

The licensees shall have and maintain financial protection of such type and in such amounts as the Commission shall require in accordance with Section 170 of the Atomic Energy Act of 1954, as amended, to cover public liability claims.

H.

This license is effective as of the date of issuance and shall expire at Midnight on March 11, 2025.

For the Nuclear Regulatory Commission Original Signed By Harold R. Denton, Director Office of Nuclear Reactor Regulation Attachments/Appendices:

1. Attachment 1 - Deleted
2. Attachment 2 - Deleted
3. Attachment 3 - Deleted
4. Appendix A - Technical Specifications (NUREG-1136)
5. Appendix B - Environmental Protection Plan
6. Appendix C - Antitrust Conditions
7. Appendix D - Additional Conditions Date of issuance: June 4, 1985 Amendment No. 108, 141, Revised by letter dated August 2, 2007