NRC 2007-0051, License Amendment Request 255, Application for Technical Specification Change TSTF-491, Removal of the Main Steam and Main Feedwater Valve Isolation Time from Technical Specifications Using Consolidated Line Item

From kanterella
(Redirected from ML071800512)
Jump to navigation Jump to search

License Amendment Request 255, Application for Technical Specification Change TSTF-491, Removal of the Main Steam and Main Feedwater Valve Isolation Time from Technical Specifications Using Consolidated Line Item
ML071800512
Person / Time
Site: Point Beach  
Issue date: 06/29/2007
From: Koehl D
Nuclear Management Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NRC 2007-0051
Download: ML071800512 (10)


Text

Point Beach Nuclear Plant Committed to Nuclear Excellence Operated by Nuclear Management Company, LLC June 29,2007 NRC 2007-0051 10 CFR 50.90 U S Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Point Beach Nuclear Plant Units 1 and 2 Dockets 50-266 and 50-301 Renewed License Nos. DPR-24 and DPR-27 License Amendment Reauest 255 A~plication for Technical S~ecification Chanae TSTF-491, "Removal of the Main Steam and Main Feedwater Valve Isolation Time From Technical S~ecifications" Usina Consolidated Line Item lm~rovement Process In accordance with the provisions of 10 CFR 50.90, Nuclear Management Company, LLC (NMC) is submitting a request for an amendment to the Technical Specifications (TS) for the Point Beach Nuclear Plant, Units 1 and 2.

The proposed amendment would modify the TS by removing the specific isolation time for the main steam isolation valves from the associated TS Surveillance Requirements (SRs). provides a description of the proposed change, the requested confirmation of applicability, and plant-specific verifications. Enclosure 2 provides the existing TS page marked up to show the proposed changes. Enclosure 3 provides the existing TS Bases pages marked up to show the proposed changes. The Bases pages are being provided for information only.

NMC requests approval of the proposed license amendment by March 14,2008, with the amendment being implemented within 90 days. In accordance with 10 CFR 50.91, a copy of this application, with enclosures, is being provided to the designated Wisconsin Official.

6610 Nuclear Road Two Rivers, Wisconsin 54241 -9516 Telephone: 920.755.2321

Document Control Desk Page 2 Summary of Commitments This letter contains no new commitments and no revisions to existing commitments.

I declare under penalty of perjury that the foregoing is true and correct.

Executed on June 29,2007.

Dennis. L. Koehl Site Vice President, Point Beach Nuclear Plant Nuclear Management Company, LLC Enclosures (3) cc:

Administrator, Region Ill, USNRC Project Manager, Point Beach Nuclear Plant, USNRC Resident Inspector, Point Beach Nuclear Plant, USNRC PSCW

Description and Assessment

1.0 DESCRIPTION

The proposed amendment would modify Technical Specifications (TS) by removing the specific isolation time for the main steam isolation valves from the associated TS Surveillance Requirements (SRs) to the inservice testing program.

The changes are consistent with Nuclear Regulatory Commission (NRC) approved lndustryrrechnical Specification Task Force (TSTF) TSTF-491, "Removal of the Main Steam and Main Feedwater Valve Isolation Time from Technical Specifications," Revision 2. The availability of this TS improvement was published in the Federal Register on December 29, 2006, as part of the Consolidated Line Item Improvement Process (CLIIP).

2.0 ASSESSMENT

2.1 Applicability of TSTF-491, and Published Safety Evaluation Nuclear Management Company, LLC (NMC) has reviewed TSTF-491 (Reference I),

and the NRC model safety evaluation (SE) (Reference 2) as part of the CLIIP. NMC has concluded that the information in TSTF-491, as well as the SE prepared by the NRC staff are applicable to the Point Beach Nuclear Plant (PBNP) Units 1 and 2, and justify this amendment for the incorporation of the changes to the PBNP TS.

2.2 Optional Changes and Variations NMC is not proposing any variations or deviations from the NRC staffs model safety evaluation dated October 5, 2006, associated with removal of the main steam isolation valve closure time surveillance. NMC, however, proposes to deviate from TSTF-491 in that PBNP TS 3.7.3 and associated SRs do not include the main feedwater valve closure times, and thus TSTF-491 changes to TS 3.7.3 are not applicable to the PBNP TS.

3.0 REGULATORY ANALYSIS

3.1 No Significant Hazards Consideration Determination NMC has reviewed the proposed no significant hazards consideration determination (NSHCD) published in the Federal Register as part of the CLIIP. NMC has concluded that the proposed NSHCD presented in the Federal Register notice is applicable to PBNP and is hereby incorporated by reference to satisfy the requirements of 10 CFR 50.91 (a).

3.2 Verification and Commitments As discussed in the notice of availability published in the Federal Register on December 29, 2006, for this TS improvement, plant-specific verifications were performed as follows: NMC has reviewed the safety evaluation (SE) published on October 5, 2006, (71 FR 193) as part of the CLllP Notice for Comment. This included the NRC staffs SE and the supporting information provided to support TSTF-491. NMC has concluded that the justifications presented in the TSTF proposal and the model SE prepared by the NRC staff are applicable to PBNP, Units 1 and 2, and justify this amendment for the incorporation of the changes to PBNP TS 3.7.2. The TSTF-491 changes to TS 3.7.3 do not apply to the PBNP TS and are not proposed for adoption.

In addition, NMC has proposed TS Bases consistent with TSTF-491 which provide guidance and details on how to implement the new requirements. Finally, NMC has a Bases Control Program consistent with Section 5.5.13 of the Standard Technical Specifications (STS).

4.0 ENVIRONMENTAL EVALUATION The amendment changes requirements with respect to the installation or use of a facility component located within the restricted area as defined in 10 CFR Part 20. The NRC staff has determined that the amendment adopting TSTF-491, Revision 2, involves no significant increase in the amounts and no significant change in the types of any effluents that may be released offsite, and that there is no significant increase in individual or cumulative occupational radiation exposure. The Commission has previously issued a proposed finding that TSTF-491, Revision 2, involves no significant hazards considerations, and there has been no public comment on the finding in Federal Register Notice 71 FR 193, October 5, 2006. Accordingly, the amendment meets the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(~)(9).

Pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the issuance of the amendment.

5.0 REFERENCES

1.

TSTF-491, Revision 2, "Removal of Main Steam and Main Feedwater Valve Isolation Times from Technical Specifications."

2.

NRC Model Safety Evaluation Report.

Page 3 of X

ENCLOSURE 2 PROPOSED CHANGES TO TECHNICAL SPECIFICATION PAGES 1 Page Follows

MSIV's and Non-Return Check Valves 3.7.2 ACTIONS SURVEILLANCE REQUIREMENTS CONDITION C. (continued)

D. Required Action and associated Completion Time of Condition C not met.

Point Beach REQUIRED ACTION C.3 Verify MSlV and non-return check valve in the affected flowpath are closed and the MSlV is de-activated.

D. 1 Be in MODE 3.

AND D.2 Be in MODE 4.

SURVEILLANCE SR 3.7.2.1 NOTE-------------------------

Only required to be performed in MODE 1.

Verify closure time of each MSlV is K

F

~

E

~

within limits.

SR 3.7.2.2 NOTE-------------------------

Only required to be performed in MODE 1.

Verify each MSlV actuates to the isolation position on an actual or simulated actuation signal.

SR 3.7.2.3 Verify each main steam non-return check valve can close.

Unit 1 - Amendment No. 2W Unit 2 - Amendment No. 286 COMPLETION TIME Once per 7 days 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> 12 hours FREQUENCY In accordance with the lnservice Testing Program 18 months In accordance with the lnservice Testing Program

ENCLOSURE 3 PROPOSED CHANGES TO TECHNICAL SPECIFICATION BASES 3 Pages Follow

MSIV's and Non-Return Check Valves B 3.7.2 BASES ACTIONS (continued) The 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> Completion Time is consistent with that allowed in Condition A.

For inoperable MSlVs or non-return check valves that cannot be restored to OPERABLE status within the specified Completion Time, but are isolated, the flowpath must be verified on a periodic basis to be closed and the MSIV de-activated. This is necessary to ensure that the assumptions in the safety analysis remain valid. The 7 day Completion Time is reasonable, based on engineering judgment, in view of flowpath indications (MSIV position) available in the control room, and other administrative controls, to ensure that these valves are in the closed position.

D.l and D.2 If the MSlVs or non-return check valves cannot be restored to OPERABLE status or are not closed within the associated Completion Time, the unit must be placed in a MODE in which the LC0 does not apply. To achieve this status, the unit must be placed at least in MODE 3 within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, and in MODE 4 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />. The allowed Completion Times are reasonable, based on operating experience, to reach the required unit conditions from MODE 2 conditions in an orderly manner and without challenging unit systems.

SURVEILLANCE SR 3.7.2.1 REQUIREMENTS This SR verifies that W W closure time of each MSIV is 4 I= (!

- V.

-within the time limit siven in Reference 5 and is within that assumed in the accident and containment analvses. This Stwdk~8 SR also verifies that the valve closure time is in accordance with the Inservice Testins Prosram. This SR is normally performed upon returning the unit to operation following a refueling outage. The MSlVs should not be tested at power, since even a part stroke exercise increases the risk of a valve closure when the unit is generating power. As the MSlVs are not tested at power, they are exempt from the ASME Code (Ref. 4), requirements during operation in MODE 1.

Point Beach

MSIV's and Non-Return Check Valves B 3.7.2 BASES SURVEILLANCE The Frequency is in accordance with the Inservice Testing Program.

REQUIREMENTS Operating experience has shown that these components usually pass (continued) the Surveillance when performed at the Frequency required by the lnservice Testing Program. Therefore, the Frequency is acceptable from a reliability standpoint.

This test is conducted in MODE 2 under low steam flow conditions (I 5% steam flow) at operating temperature and pressure. This SR is modified by a Note that allows entry into and operation in MODES 2 and 3 prior to performing the SR. This allows a delay of testing to establish conditions consistent with those under which the acceptance criterion was generated.

This SR verifies that each MSlV will actuate to its isolation position on a actuation isolation signal. The 18 month Frequency is based on a refueling cycle interval and the potential for an unplanned transient if the Surveillance were performed with the reactor at power. Operating experience has shown that these components normally pass this Surveillance when performed at the 18 month Frequency. Therefore, the Frequency was concluded to be acceptable from a reliability standpoint.

This SR is modified by a Note that allows entry into and operation in MODES 2 and 3 prior to performing the SR. This allows delaying testing until conditions where the testing can be performed are established.

This SR verifies that each main steam non-return check valve can close. As the non-return check valves are not tested at power, they are exempt from the ASME Code (Ref. 4) requirements during operation in MODE 1,2, or 3. The Frequency is in accordance with the lnservice Testing Program. Operating experience has shown that these components usually pass the Surveillance when performed at the Frequency required by the lnservice Testing Program. Therefore, the Frequency is acceptable from a reliability standpoint.

Point Beach

MSIV's and Non-Return Check Valves B 3.7.2 REFERENCES 1. FSAR, Section 1 0.1

2. FSAR, Section 14.2.5.
3. 10 CFR 100.11.
4. ASME Boiler and Pressure Vessel Code,Section XI, OM Code, Code for Operation and Maintenance of Nuclear Power Plants.
5. p Ju++CbTRM 4.7, Inservice Testing Program Point Beach