Safety and Relief Valves 3.4.3 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.4.3.1 Verify the safety function lift setpoints of the safety valves are as follows:
In accordance with the Inservice Testing Program Number of Safety Valves 1
2 2
4 Following testing, within +/- 1%.
Setpoint
( ps i q )
1135 +/- 34.1 1240 +/- 37.2 1250 +/- 37.5 1260 +/- 37.8 lift settings shall be SR 3.4.3.2 Verify each relief valve actuator strokes 24 months when manually actuated.
NOTE --------------------
Valve actuation may be excluded.
Verify each relief valve actuates on an 24 months actual or simulated automatic initiation signal.
Dresden 2 and 3 3.4.3-2 Amendment No.223 /215