CONTAINMENT SYSTEMS SURVEILLANCE REQUIREMENTS (Continued)
- c.
At least once per 18 months, during shutdown, by:
- 1.
Verifying that each automatic valve in the flow path actuates to its correct position on CSAS and RAS test signals.
- 2.
Verifying that upon a RAS test signal, the containment sump isolation valves open and that a recirculation mode flow path via an OPERABLE shutdown cooling heat exchanger is established.
- 3.
Verifying that each spray pump starts automatically on a CSAS test signal.
- d.
Verify each spray nozzle is unobstructed following maintenance which could result in nozzle blockage.
ARKANSAS - UNIT 2 3/4 6-.11 Amendment No. 94,245, 272