DPO-2006-002: Oconee ECCS Sump Screens

Subject:

This DPO raises concerns about new ECCS sump screens at the Oconee facility. The submitter contends that the new sump screens can be impacted by jet impingement from an RCS cold leg break (LOCA) and that the licensee should be required to perform an analysis (per GDC-4) prior to installation.

Assigned to: Jim Dyer, NRR OD DPO Decision: 1/20/2007 DPO Follow Up Actions and Schedule-.,,

Recommendation Number/Action Item Original Revised Lead Schedule Schedule Office

1. Develop a knowledge management document 03/16/07 04/16/071 . NRR describing the NRC's policy and practice on the application of LBB (NRR Yellow Ticket 020060239) 1Division of Component Integrity needed more time to get this completed due to their work load.