ML070920458
| ML070920458 | |
| Person / Time | |
|---|---|
| Site: | River Bend |
| Issue date: | 05/03/2007 |
| From: | NRC/NRR/ADRO/DORL/LPLIV |
| To: | |
| Vaidya B, NRR/DORL/LP4, 415-3308 | |
| Shared Package | |
| ML070920443 | List: |
| References | |
| Download: ML070920458 (1) | |
Text
PCIVs 3.6.1.3 SURVEILLANCE REQUIREMENTS (continued)
SURVEILLANCE FREQUENCY SR 3.6.1.3.4 Verify the isolation time of each power operated In accordance and each automatic PCIV, except MSIVs, is within with the Inservice limits.
Testing Program SR 3.6.1.3.5
NOTE---------------
Only required to be met in MODES 1, 2, and 3.
Perform leakage rate testing for each primary In accordance with containment purge valve with resilient seals.
the Primary Containment Leakage Rate Testing Program SR 3.6.1.3.6 Verify the isolation time of each MSIV is In accordance with the Inservice
>_ 3 seconds and < 5 seconds.
Testing Program SR 3.6.1.3.7 Verify each automatic PCIV actuates to the 18 months isolation position on an actual or simulated isolation signal.
(continued)
RIVER BEND 3.6-17 Amendment No. 84, 152