|
---|
Category:Meeting Briefing Package/Handouts
MONTHYEARML23257A1582023-09-18018 September 2023 NRC Staff Feedback Draft TSTF-601, Extend Shield Building Completion Time After Refueling for Pre-submittal Meeting on 9/18/23 ML23033A3842023-02-0202 February 2023 February 9, 2023, Meeting Handout: NRC Staff Comments on TSTF-576 Revision 2 (Draft), SRV Requirements ML22298A2162022-10-25025 October 2022 TSTF Meeting Handout TSTF-585 and the Maintenance Rule ML22298A2172022-10-24024 October 2022 TSTF Meeting Handout Strategic Improvements to TS and TS-Related Processes ML22298A2152022-10-20020 October 2022 TSTF Meeting Handout Natural Phenomena and Operability Workshop ML22056A2942022-02-24024 February 2022 2/24/2022 Meeting Handout - TSTF 2021 in Review ML22056A2932022-02-24024 February 2022 2/24/2022 Meeting Handout - Active Traveler Summary Report ML22038A6032022-02-10010 February 2022 Summary of January 10, 2022, Meeting with the Technical Specifications Task Force Draft Traveler TSTF-589 Eliminate Automatic Diesel Generator Start During Shutdown ML22013B1422022-02-0101 February 2022 TSTF-576 Workshop February 2022 - NRC Presentation ML21217A0692021-08-0505 August 2021 Meeting Handout - Active Traveler Summary Report ML21158A0902021-06-0707 June 2021 Technical Specifications Branch Feedback/Comments on Draft TSTF-585, Revise LCO 3.0.3 ML21126A0722021-05-0606 May 2021 5/6/2021 Meeting Handout - Expected TSTF-577 Submittals ML21126A0732021-05-0606 May 2021 5/6/2021 Meeting Handout - Active Traveler Summary Report ML21126A0712021-05-0606 May 2021 5/6/2021 Meeting Handout - Interaction of Technical Specification Surveillances and 10 CFR 50.69 ML21029A3082021-01-29029 January 2021 Trio Public Meeting Slides (Thursday, February 4, 2021) ML21007A1112021-01-0707 January 2021 TSTF-577, NRC Staff Slides from Public Meeting on 1_7_2021 ML20329A3412020-11-24024 November 2020 TSTF-576 Example Scenarios for 12/7/2020 Meeting ML20287A2632020-10-13013 October 2020 TSTF Presentation Proposal to Improve the Core Operating Limits Report (COLR) ML20125A0922020-05-0404 May 2020 May 4, 2020, Pre-submittal Meeting Handout Staff Comments Draft TSTF-577, Revised Frequencies for Steam Generator Tube Inspections ML20065J9342020-03-0505 March 2020 March 5 2020 Meeting Handout, Agenda Item Iia - 2019 in Review ML20065J9332020-03-0505 March 2020 March 5 2020 Meeting Handout, Agenda Item IV - Active Traveler Summary Report and Priorities ML20065J9902020-03-0505 March 2020 March 5 2020 TSTF Quarterly Meeting Handout, Agenda Item Iiib - Generic RAIs for LARs to Adopt TSTF-505 Rict ML20069F2882020-03-0505 March 2020 March 5 2020 TSTF Quarterly Meeting Handout, Agenda Item Iia - 2019 in Review ML20065J9322020-03-0505 March 2020 March 5 2020 Meeting Handout, Agenda Item VA - Proposal to Revise LCO 3.0.3 ML20069F2852020-01-0101 January 2020 March 5 2020 TSTF Quarterly Meeting Handout, Agenda Item Via - TSTF Charter Statement 2020 ML19267A1592019-09-24024 September 2019 TSTF Handout for October 16, 2019, Meeting: TSTF-493 Questions ML19259A2082019-09-12012 September 2019 TSTF Presentation from TSTF-576, S/Rv Requirements Pre-submittal Meeting on September 12, 2019 TSTF-19-07, TSTF Handout for October 16, 2019, Meeting: Elimination of Commitment to Adopt TSTF-4932019-06-18018 June 2019 TSTF Handout for October 16, 2019, Meeting: Elimination of Commitment to Adopt TSTF-493 ML19056A4262019-02-21021 February 2019 Rewording of TSTF Revision to TSTF-541, Add Exceptions to Surveillance Requirements When the Safety Function Is Being Performed ML19056A4242019-02-21021 February 2019 TSTF-568 Proposed Path Forward from 2/21/2019 Meeting ML19056A4232019-02-21021 February 2019 Meeting Attendees 02/21/2019 ML18312A3672018-11-0808 November 2018 Handout from 11/08/2018 TSTF Meeting for Agenda Item Ii.B.C November 2018 Traveler Review Schedule Changes ML18312A3662018-11-0808 November 2018 Handout from 11/8/2018 TSTF Meeting for Agenda Items V.A and V.B Active Traveler Summary Report and Traveler Review Priorities ML18221A5812018-08-0909 August 2018 August 9, 2018, Meeting Agenda Item 5.A.6 NRC Feedback Re TSTF-568 Evaluation of STS 3.6.3.2 ML18221A5772018-08-0909 August 2018 August 9, 2018, Meeting Agenda Item 4.C - TSTF-542 Adoption Status ML18221A5752018-08-0909 August 2018 August 9, 2018, Meeting Agenda Item 5.A Active Traveler Summary Report ML18221A5742018-08-0909 August 2018 August 9, 2018, Meeting Agenda Item 5.A.6 - TSTF-565R1 ML18221A5722018-08-0909 August 2018 August 9, 2018, Meeting Agenda Item 3.A - DNP LAR Analysis ML18221A5712018-08-0909 August 2018 August 9, 2018, Meeting Agenda Item 4.A TSTF Response TSTF-51 -286 -471 ML18221A5732018-08-0606 August 2018 August 9, 2018, Meeting Agenda Item 7.A - Is the Table of Contents Part of the Technical Specifications? ML18142B0372018-05-17017 May 2018 May 17, 2018, Meeting Agenda Item 2.A - TSTF-563 Coordinated Submittal Pilot ML18142B0352018-05-17017 May 2018 May 17, 2018, Meeting Agenda Item 4.B - TSTF-547 Issue ML18142B0382018-05-17017 May 2018 May 17, 2018, Meeting Agenda Item 5 - Active Traveler Summary Report ML18142B0362018-05-17017 May 2018 May 17, 2018, Meeting Agenda Item 4.A TSTF Response TSTF-51 -286 -471 ML18142B0342018-05-17017 May 2018 May 17, 2018, Meeting Agenda Item 3.A - Traveler Adoption ML18142B0332018-05-17017 May 2018 May 17, 2018, Meeting Agenda Item 8.A - Approved Unincorporated Travelers ML18142B0312018-05-17017 May 2018 May 17, 2018, Meeting Agenda Item 8.A - T Traveler Candidates ML18051A2362018-02-15015 February 2018 Attendee List from 2/15/2018 Quarterly Meeting with TSTF ML18051A2012018-02-15015 February 2018 Active Traveler Status Report and Traveler Priorities from 2/15/2018 Quarterly Meeting ML18051A1992018-02-15015 February 2018 Approval of ASME Code Cases for Industry Use, TSTF Presentation from 2/15/2018 Quarterly Meeting 2023-09-18
[Table view] |
Text
NRC REVIEW FEES FOR CLIIP TSTF - 358 TSTF - 413 TSTF - 359 TSTF - 404 TSTF - 447 TSTF-369 TSTF - 460 TSTF-366 TSTF-370 Last Plant (Missed SR's) (PASS) (Flexible Mode Restraints) (SDIV) (H2 Recombiners) (MOR-ORER) (Scram Time Testing) (PASS) (Accumulator AOT)
Plant Update Type All Plants BWRs All Plants BWRs All Plants All Plants BWRs W & CE W Approved 09-28-01 Approved 03-20-02 Approved 03-08-03 Approved 04-08-03 Approved 09-25-03 Approved 06-23-04 Approved 08-23-04 Approved 10-31-00 Approved 03-06-03 Average $4,391 $2,348 $5,631 $1,226 $2,668 $1,660 $6,732 $2,958 $1,423 Responses 15 5 12 5 14 18 4 4 3 Overall Average: $3,678 Number of data points: 93 Min $0 Max $27,675 3/22/2007 Page 1 of 3 Technical Specification Task Force
NRC REVIEW FEES FOR CLIIP Elimination of Typical License Condition Requiring Reporting of TSTF-442 TSTF-421 TSTF-373 TSTF-372 TSTF-449 TSTF-422 Violations of Section 2.C TSTF - 454 TSTF - 423 Last Plant (PASS) (RCP Flywheel) (CIVs) (Snubbers) (SG Tube Inspection) (Preferred End States) of Operating License (PCIV CTs) (End States)
Plant Update Type B&W W CE All Plants PWRs CE All Plants BWRs BWRs Approved 05-06-03 Approved 10-15-03 Approved 02-20-04 Approved 05-04-05 Approved 05-06-05 Approved 07-05-05 Approved 11-04-05 Approved 12/13/05 Approved 3/23/06 Average $1,256 $2,767 $0 $4,452 $6,150 $0 $3,915 $0 $0 Responses 1 3 0 5 1 0 3 0 0 Overall Average:
Number of data points:
Min Max 3/22/2007 Page 2 of 3 Technical Specification Task Force
NRC REVIEW FEES FOR CLIIP TSTF-374 TSTF-427 TSTF-484 TSTF-409 TSTF-491 TSTF-448 Last Plant (Fuel Oil) (Barriers) (Scram Time Testing) (Cont Spray CT) (MSIV Iso Time) (Control Room Hab)
Plant Update Type All Plants All Plants BWRs CE PWRs All Plants Approved 05-04-05 Approved 10-02-06 Approved 10-27-06 Approved 11-7-06 Approved 11-7-06 Approved 1-17-07 Average $27,675 68 68 68 68 68 Responses 1 0 1 0 0 0 Overall Average:
Number of data points:
Min Max 3/22/2007 Page 3 of 3 Technical Specification Task Force