ML070800449

From kanterella
Jump to navigation Jump to search

Confirmatory Action Letter (CAL No. NRR-07-023) Palisades Nuclear Plant
ML070800449
Person / Time
Site: Palisades Entergy icon.png
Issue date: 03/29/2007
From: Dyer J
Office of Nuclear Reactor Regulation
To: Harden P
Nuclear Management Co
Chawla M, NRR/DORL, 415-8371
References
TAC MD4168, NRR-07-023
Download: ML070800449 (5)


Text

March 29, 2007 CAL No. NRR-07-023 Mr. Paul A. Harden Site Vice President, Palisades Nuclear Plant Palisades Nuclear Plant Nuclear Management Company, LLC 27780 Blue Star Memorial Highway Covert, MI 49043-9530

SUBJECT:

CONFIRMATORY ACTION LETTER - PALISADES NUCLEAR PLANT (TAC NO. MD4168)

Dear Mr. Harden:

This letter confirms commitments by Nuclear Management Company, LLC, regarding Alloy 82/182 butt welds in the pressurizer at Palisades Nuclear Plant.

The discovery, in October 2006, of five circumferential indications in three dissimilar metal (DM) welds on the pressurizer at the Wolf Creek Generating Station (Wolf Creek) raised safety concerns based on the size and location of the indications. At Wolf Creek, three indications were in the pressurizer surge nozzle-to-safe end weld, and two separate indications were in the safety and relief nozzle-to-safe end welds. These findings also indicated that significant concerns might exist with the inspection schedules for addressing the pressurizer weld concerns issued by the industry-sponsored Materials Reliability Program (MRP), in Primary System Piping Butt Weld Inspection and Evaluation Guideline (MRP-139).

The Nuclear Regulatory Commission (NRC) is concerned about the pressurizer surge nozzle-to-safe end weld indications, as this is the first time that multiple circumferential primary water stress-corrosion cracking (PWSCC) indications have been identified in a weld. This condition calls into question the degree of safety margin present in past structural integrity evaluations for flawed DM welds susceptible to PWSCC, since multiple stress-corrosion cracking flaws may grow independently and ultimately grow together, significantly reducing the time from flaw initiation to leakage or rupture. The size of the relief nozzle-to-safe end flaw is also of concern, as this flaw has a much larger aspect ratio than those assumed in the estimates used to establish the basis for completing the baseline inspections required by the industry-sponsored MRP. Larger aspect ratios could result in achieving a critical flaw size and rupture before the onset of detectable leakage.

The long-term resolution of this issue is expected to involve changes to the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code), and will involve changes to the NRC regulations in Title 10 of the Code of Federal Regulations (10 CFR),

Part 50, Section 50.55a, Codes and standards. The development of the NRC regulations, whether the rule adopts the ASME Code standards or defines separate requirements, will likely benefit from additional operating experience, continuing assessments, and analysis being conducted by the NRC and the MRP.

P. Harden Until NRC regulations are revised, it is necessary to establish a minimum set of enhanced reactor coolant system (RCS) DM butt weld inspection expectations for nickel-based Alloy 82/182 pressurizer surge, spray, safety, and relief nozzle butt welds, including safe end welds, to supplement existing inspection and other requirements of the ASME Code and NRC regulations. In addition, enhanced monitoring of RCS leakage is needed to promptly identify any through-wall flaws in the pressurizer surge, spray, safety, or relief nozzle DM butt welds or safe end DM butt welds to prevent additional degradation from occurring. The above actions provide reasonable assurance that there is no undue risk to the health and safety of the public while the NRC regulations are revised.

The NRC communicated the need for near-term enhancements to the industry through public meetings held on November 30, 2006, December 20, 2006, and February 2, 2007. Licensees submitted letters voluntarily committing to the enhanced inspection and leakage monitoring requirements. After teleconferences with specific licensees held between February 12 through February 23, 2007, the licensees submitted supplemental commitment letters addressing the NRC staffs concerns regarding inspection, compensatory actions, and reporting.

In your letter dated February 27, 2007 (Agencywide Documents Access & Management System (ADAMS) Accession Number ML070590333) you described actions you will take at Palisades Nuclear Plant for the pressurizer dissimilar metal butt welds containing Alloy 82/182 material.

These commitments address: 1) completion schedules for inspection of the welds; 2) RCS leak monitoring frequency, action levels, and actions; 3) reporting requirements and 4) reinspection frequencies.

The NRC staff has reviewed these actions and commitments and agrees the actions and commitments are appropriate to address the potential of PWSCC of the applicable pressurizer dissimilar metal butt welds containing Alloy 82/182 material.

Pursuant to Section 182 of the Atomic Energy Act, 42 U.S.C. 2232, you are required to:

1) Notify me immediately if your understanding differs from that set forth above;
2) Notify me if for any reason you cannot complete the actions and commitments within the specified schedule and advise me in writing of your modified schedule in advance of the change; and
3) Notify me in writing when you have completed the actions and commitments addressed in this Confirmatory Action Letter.

Issuance of this Confirmatory Action Letter does not preclude issuance of an order formalizing the above commitments or requiring other actions on the part of the licensee; nor does it preclude the NRC from taking enforcement action for violations of NRC requirements that may have prompted the issuance of this letter. In addition, failure to take the actions addressed in this Confirmatory Action Letter may result in enforcement action.

In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter and your response will be made available electronically for public inspection in the NRC Public Document Room or from the NRCs ADAMS, accessible from the NRC Web site at

P. Harden http://www.nrc.gov/reading-rm/adams.html. To the extent possible, your response should not include any personal privacy, proprietary, or safeguards information so that it can be made available to the Public without redaction. If personal privacy or proprietary information is necessary to provide an acceptable response, then please provide a bracketed copy of your response that identifies the information that should be protected and a redacted copy of your response that deletes such information. If you request withholding of such material, you must specifically identify the portions of your response that you seek to have withheld and provide in detail the bases for your claim of withholding (e.g., explain why the disclosure of information will create an unwarranted invasion of personal privacy or provide the information required by 10 CFR 2.390(b) to support a request for withholding confidential commercial or financial information). If safeguards information is necessary to provide an acceptable response, please provide the level of protection described in 10 CFR 73.21.

Sincerely,

/RA/

J. E. Dyer, Director Office of Nuclear Reactor Regulation Docket No. 50-255 License No. DPR-20 cc: See next page

ML070800449 OFFICE CPNB DCI LPL3-1/PM LPL3-1/LA LPL3-1/BC TECH ED DIRS/TA NAME KHoffman ESullivan MChawla THarris LRaghavan HChang RPascarelli DATE 3/22/07 3/22/07 3/22/07 3/22/07 3/22/07 2/28/07 3/23/07 OFFICE CPNB/BC DRP/D RGN3 DORL/D DCI/D AD:DES NRR/D NAME TChan MSatorius CHaney MEvans JGrobe JDyer DATE 3/22/07 3/28/07 3/26/07 3/28/07 3/28/07 3/29/07 Palisades Plant cc:

Robert A. Fenech, Senior Vice President Michael B. Sellman Nuclear, Fossil, and Hydro Operations President and Chief Executive Officer Consumers Energy Company Nuclear Management Company, LLC 1945 Parnall Rd. 700 First Street Jackson, MI 49201 Hudson, MI 54016 Arunas T. Udrys, Esquire Jonathan Rogoff, Esquire Consumers Energy Company Vice President, Counsel & Secretary 1 Energy Plaza Nuclear Management Company, LLC Jackson, MI 49201 700 First Street Hudson, WI 54016 Regional Administrator, Region III U.S. Nuclear Regulatory Commission Douglas E. Cooper Suite 210 Senior Vice President and 2443 Warrenville Road Chief Nuclear Officer Lisle, IL 60532-4351 Nuclear Management Company, LLC 700 First Street Supervisor Hudson, WI 54016 Covert Township P. O. Box 35 Stephen T. Wawro, Director Covert, MI 49043 of Nuclear Assets Consumers Energy Company Office of the Governor Palisades Nuclear Plant P. O. Box 30013 27780 Blue Star Memorial Highway Lansing, MI 48909 Covert, MI 49043 U.S. Nuclear Regulatory Commission Laurie A. Lahti, Manager Resident Inspector's Office Regulatory Affairs Palisades Plant Nuclear Management Company, LLC 27782 Blue Star Memorial Highway Palisades Nuclear Plant Covert, MI 49043 27780 Blue Star Memorial Highway Covert, MI 49043 Michigan Department of Environmental Quality Waste and Hazardous Materials Division Hazardous Waste and Radiological Protection Section Nuclear Facilities Unit Constitution Hall, Lower-Level North 525 West Allegan Street P.O. Box 30241 July 2006 Lansing, MI 48909-7741 Michigan Department of Attorney General Special Litigation Division 525 West Ottawa St.

Sixth Floor, G. Mennen Williams Building Lansing, MI 48913