MONTHYEARML21272A2702021-10-19019 October 2021 Federal Register Notice: Saint Lucie Plant, Units 1 and 2 - Notice of Intent to Conduct Scoping Process and Prepare an Environmental Impact Statement ML21246A0922021-09-24024 September 2021 FRN - St. Lucie Plant, Units 1 and 2 - SLRA Opportunity to Request a Hearing ML21217A1962021-08-10010 August 2021 SLRA - Receipt and Availability FRN ML21165A0292021-07-20020 July 2021 FRN, Exemption from Schedular Requirements of 10 CFR Part 54.17, Filing of Application ML20177A6452020-07-15015 July 2020 FRN - Notice of Issuance of Multiple Exemptions Regarding Various Parts of 10 CFR Due to COVID-19 Impacts for June 2020 ML19337A0312019-12-11011 December 2019 Biweekly Federal Register Notice - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: 12/17/2019 ML19168A0842019-06-26026 June 2019 Biweekly Federal Register Notice - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: 07/02/2019 ML18351A0022019-01-0202 January 2019 Biweekly Federal Register Notice - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: 01/02/2019 NRC-2018-0287, Biweekly Federal Register Notice - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: 01/02/20192019-01-0202 January 2019 Biweekly Federal Register Notice - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: 01/02/2019 ML18173A1792018-08-0707 August 2018 OEDO-17-00070 - Notice of Issuance of Director'S Decision, 2.206 Petition for Emergency Enforcement Action Per 10 CFR 2.206 at Listed U.S. Reactors with Forged Components and Parts Manufactured at France'S AREVA-Le Creusot Forge and Japan C NRC-2018-0025, St. Lucie Plant, Units 1 and 2 - Letter to Licensee Individual Notice of Consideration of Issuance of Amendments to Fols, Proposed NSHC, and Opportunity for Comment & Hearing2018-02-0808 February 2018 St. Lucie Plant, Units 1 and 2 - Letter to Licensee Individual Notice of Consideration of Issuance of Amendments to Fols, Proposed NSHC, and Opportunity for Comment & Hearing ML18037A6192018-02-0808 February 2018 Letter to Licensee Individual Notice of Consideration of Issuance of Amendments to Fols, Proposed NSHC, and Opportunity for Comment & Hearing ML17200A0652017-08-30030 August 2017 OEDO-17-00070 - Acknowledgement FRN, Paul Gunter, Beyond Nuclear, 2.206 Petition for Emergency Enforcement Action Per 10 CFR 2.206 at Listed U.S. Reactors with Forged Components and Parts Manufactured at France'S AREVA-Le Creusot Forge and ML17198A3292017-08-30030 August 2017 OEDO-17-00070 - Acknowledgement Letter, Paul Gunter, Beyond Nuclear, Petition for Emergency Enforcement Action Per 10 CFR 2.206 at Listed U.S. Reactors with Forged Components and Parts Manufactured at France'S AREVA-Le Creusot Forge and Jap NRC-2011-0302, FRN: St. Lucie Plant, Units 1 and 2 - Environmental Assessment and Finding of No Significant Impact Related to the National Marine Fisheries Service Biological Opinion (CAC Nos. MF7661 and MF7662)2016-11-0303 November 2016 FRN: St. Lucie Plant, Units 1 and 2 - Environmental Assessment and Finding of No Significant Impact Related to the National Marine Fisheries Service Biological Opinion (CAC Nos. MF7661 and MF7662) ML16251A1192016-11-0303 November 2016 FRN: St. Lucie Plant, Units 1 and 2 - Environmental Assessment and Finding of No Significant Impact Related to the National Marine Fisheries Service Biological Opinion ML16271A0922016-09-28028 September 2016 Biweekly Federal Register Notice - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: October 11, 2016 NRC-2016-0202, Biweekly FRN - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: September 27, 20162016-09-19019 September 2016 Biweekly FRN - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: September 27, 2016 ML16257A5172016-09-19019 September 2016 Biweekly FRN - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: September 27, 2016 NRC-2016-0161, Biweekly Federal Register Notice - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: August 16, 20162016-08-0303 August 2016 Biweekly Federal Register Notice - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: August 16, 2016 ML16215A2272016-08-0303 August 2016 Biweekly Federal Register Notice - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: August 16, 2016 ML16167A0792016-07-0808 July 2016 Sace 2.206 Petition, Final Director'S Decision (DD-16-02) - Letter to Petitioner NRC-2015-0235, St. Lucie Plant, Unit 2, Sace 2.206 Petition, Final Director'S Decision (DD-16-02) - Federal Register Notice2016-07-0808 July 2016 St. Lucie Plant, Unit 2, Sace 2.206 Petition, Final Director'S Decision (DD-16-02) - Federal Register Notice ML16167A0902016-07-0808 July 2016 Sace 2.206 Petition, Final Director'S Decision (DD-16-02) - Federal Register Notice ML16145A2252016-06-0707 June 2016 Biweekly Federal Register Notice - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: June 7, 2016 NRC-2016-0107, Biweekly Federal Register Notice - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: June 7, 20162016-06-0707 June 2016 Biweekly Federal Register Notice - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: June 7, 2016 ML16055A3302016-05-24024 May 2016 OEDO-15-00026 - St. Lucie Plant, Unit 2 - SACE 2.206 Petition, Proposed Director's Decision, Letter to Licensee ML16055A2842016-05-24024 May 2016 OEDO-15-00026 - St. Lucie Plant, Unit 2 - Sace 2.206 Petition, Proposed Director'S Decision NRC-2016-0085, St. Lucie Plant, Unit No. 2 - FRN Exemption from the Requirements of 10 CFR 5.46 and Appendix K to 10 CFR Part 50 to Allow the Use of M5 Fuel Rod Cladding2016-04-19019 April 2016 St. Lucie Plant, Unit No. 2 - FRN Exemption from the Requirements of 10 CFR 5.46 and Appendix K to 10 CFR Part 50 to Allow the Use of M5 Fuel Rod Cladding ML16027A1632016-04-19019 April 2016 FRN Exemption from the Requirements of 10 CFR 5.46 and Appendix K to 10 CFR Part 50 to Allow the Use of M5 Fuel Rod Cladding ML15205A2962015-09-28028 September 2015 OEDO-15-00026 - St. Lucie 2.206 Acknowledgement Letter FRN ML15231A8382015-08-21021 August 2015 Biweekly FRN - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - September 1, 2015 NRC-2015-0204, Biweekly FRN - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - September 1, 20152015-08-21021 August 2015 Biweekly FRN - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - September 1, 2015 ML15204A2792015-07-27027 July 2015 Biweekly FRN - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: August 4, 2015 NRC-2015-0123, Application and Amendments to Facility Operating Licenses and Combined Licenses Involving Proposed No Significant Hazards Considerations and Containing Sensitive Unclassified Non-Safeguards Information and Order Imposing Procedures for2015-05-20020 May 2015 Application and Amendments to Facility Operating Licenses and Combined Licenses Involving Proposed No Significant Hazards Considerations and Containing Sensitive Unclassified Non-Safeguards Information and Order Imposing Procedures for Acce ML15125A4952015-05-20020 May 2015 Application and Amendments to Facility Operating Licenses and Combined Licenses Involving Proposed No Significant Hazards Considerations and Containing Sensitive Unclassified Non-Safeguards Information and Order Imposing Procedures for Acce ML15022A6532015-01-26026 January 2015 Biweekly Sholly FRN - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations - Publication Date: February 3, 2015 NRC-2014-0001, 03/31/2014 - 04/04/2014 Commission Meetings - FRN2014-04-0101 April 2014 03/31/2014 - 04/04/2014 Commission Meetings - FRN ML14091A0472014-04-0101 April 2014 04/04/2014 Commission Meetings - FRN ML14064A1212014-03-31031 March 2014 License Exemption for Florida Power & Light Company, St. Lucie Nuclear Plant, Unit 1 ML14051A6712014-03-0404 March 2014 FRN: Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations: Publication Date: March 4, 2014 NRC-2014-0037, FRN: Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations: Publication Date: March 4, 20142014-03-0404 March 2014 FRN: Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving No Significant Hazards Considerations: Publication Date: March 4, 2014 ML13225A5572013-08-12012 August 2013 Rescission of Certain Security Orders Concerning Spent Nuclear Fuel in Transit ML13228A3992013-08-12012 August 2013 Letter to Holders of Independent Spent Fuel Storage Installation (ISFSI) Licenses Re Rescission of Certain Security Orders Concerning Spent Nuclear Fuel in Transit - Rin 3150-AI64 (NRC-2009-0163) EA-02-109 ML12233A6342012-08-29029 August 2012 G20120317/EDATS: OEDO-2012-0273 - Federal Register Notice - Receipt of Request for Action Regarding St. Lucie Units 1 and 2, and Turkey Point Units 3 and 4 ML12233A6272012-08-29029 August 2012 G20120317/EDATS: OEDO-2012-0273 - 2.206 Acknowledgement Letter to T. King on St. Lucy Units 1 and 2, and Turkey Point Units 3 and 4 ML12195A1682012-07-13013 July 2012 Letters to H. Mueller, A. Hubbard, and S. Norton Re Environmental Assessment and Finding of No Significant Impact Related to Proposed Extended Power Uprate ML12165A5112012-06-25025 June 2012 Environmental Assessment and Finding of No Significant Impact Related to the Proposed Extended Power Uprate ML12165A5122012-06-25025 June 2012 Federal Register - Environmental Assessment and Finding of No Significant Impact Related to the Proposed Extended Power Uprate ML12096A2722012-04-30030 April 2012 Federal Register Notice - Exemption from the Requirements of 10 CFR Pat 50, Appendix G 2021-09-24
[Table view] Category:Order Prohibiting
MONTHYEARML0706803652007-03-21021 March 2007 FRN - Order Prohibiting Involvement in NRC-Licensed Activities Mr. James Francis Mattocks 2007-03-21
[Table view] |
Text
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION In the Matter of )
) IA-07-008 James Francis Mattocks )
ORDER PROHIBITING INVOLVEMENT IN NRC-LICENSED ACTIVITIES (IMMEDIATELY EFFECTIVE)
I Mr. James Francis Mattocks was employed as a contract security officer at Florida Power and Light Companys St. Lucie Nuclear Plant (Licensee) from approximately September 6, 2005, to January 7, 2006. Licensee holds license Nos. DPR-67 and NPF-16, issued by the U.S. Nuclear Regulatory Commission (NRC or Commission) pursuant to 10 CFR Part 50 on March 1, 1976 (Unit 1), and June 10, 1983 (Unit 2). The license authorizes the operation of the St. Lucie Nuclear Plant, Units 1 and 2, in accordance with the conditions specified therein. The facility is located on the Licensee's site in St. Lucie County, Florida.
II In 2006, Florida law enforcement officials conducted a criminal investigation into the theft of a weapon and thermal imaging scope from the Licensees facility. As a result of the investigation, the State of Florida concluded that in December 2005, Mr. Mattocks, while employed as a contract security officer, deliberately removed a Bushmaster .223 Caliber M4/A3 assault rifle and thermal imaging scope from the Licensees facility without authorization. On December 20, 2006, Mr. Mattocks entered a plea of guilty to the charge of Grand Theft - Firearm in the Circuit Court for St. Lucie County and was adjudged guilty of the charge upon the Courts acceptance of his plea. Mr. Mattocks was sentenced to 14 months of incarceration to be followed by 2 years probation.
2 License Nos. DPR-67 and NPF-16, Section 3.F, Physical Protection, require the Licensee to fully implement and maintain in effect all provisions of the Commission-approved physical security, training and qualification, and safeguards contingency plans including amendments. The Licensees Physical Security Plan (PSP), Section 15.6, establishes the requirement that the Licensee maintain a firearms program to ensure firearms function properly. The PSP states, in part, that the program is described in facility procedures and includes provisions to account for Licensee firearms. Licensee implementing procedure, SEC-AD-1003, Section 5.1.2 states, in part, that for any weapon that is taken from the stations inventory for disposal or sale, the station will document the weapon by make, model, name of institution or individual the weapons accountability was transferred to, signature of the Security Manager/designee releasing ownership of the weapon, and the date the weapon was released from the stations inventory. In this case, Mr. Mattocks removed the weapon and scope from station inventory without any authorization or approvals.
III Based on the above, Mr. James Francis Mattocks, a former employee of the Licensee, has engaged in deliberate misconduct that has caused the Licensee to be in violation of 10 CFR 50.5. NRC must be able to rely on the Licensee and its employees to comply with NRC requirements with honesty and integrity. Mr. Mattocks' actions in this case caused the Licensee to violate its PSP and raise serious doubt as to whether he can be relied upon to comply with NRC requirements with honesty and integrity. Consequently, I lack the requisite reasonable assurance that licensed activities can be conducted in compliance with the Commission's requirements and that the health and safety of the public will be protected if Mr. James Francis
3 Mattocks were permitted at this time to be involved in NRC licensed activities. Therefore, the public health, safety and interest require that Mr. James Francis Mattocks be prohibited from any involvement in NRC-licensed activities for a period of five years from the date of this Order.
Additionally, Mr. James Francis Mattocks is required to notify the NRC of his first employment in NRC-licensed activities for a period of three years following expiration of the prohibition period.
Furthermore, pursuant to 10 CFR 2.202, I find that the significance of Mr. James Francis Mattocks conduct described above is such that the public health, safety and interest require that this Order be immediately effective.
IV Accordingly, pursuant to sections 103, 161b, 161i, 182 and 186 of the Atomic Energy Act of 1954, as amended, and the Commission's regulations in 10 CFR 2.202, 10 CFR 50.5, and 10 CFR 150.20, IT IS HEREBY ORDERED, EFFECTIVE IMMEDIATELY, THAT:
- 1. Mr. James Francis Mattocks is prohibited from engaging in NRC-licensed activities for a period of five years from the date of this Order. NRC-licensed activities are those activities that are conducted pursuant to a specific or general license issued by the NRC, including, but not limited to, those activities of Agreement State licensees conducted pursuant to the authority granted by 10 CFR 150.20.
- 2. If Mr. James Francis Mattocks is currently involved in licensed activities on behalf of an NRC licensee, he must immediately cease those activities, inform the NRC of the name, address and telephone number of the licensee employer, and provide a copy of this order to the licensee employer.
4
- 3. For a period of three years after the five year period of prohibition has expired, Mr. James Francis Mattocks shall, within 20 days of acceptance of an offer of employment involving his performance of NRC-licensed activities or his becoming involved in NRC-licensed activities, as defined in Paragraph IV.1 above, provide notice to the Director, Office of Enforcement (OE), U. S. Nuclear Regulatory Commission, Washington, DC 20555-0001, of the name, address, and telephone number of the employer or the entity on whose behalf he will be involved in the NRC-licensed activities. In the notification, Mr. James Francis Mattocks shall include a statement of his commitment to compliance with regulatory requirements and the basis upon which the Commission should have confidence that he will now comply with applicable NRC requirements.
The Director, OE, may, in writing, relax or rescind any of the above conditions upon demonstration by Mr. James Francis Mattocks of good cause.
V In accordance with 10 CFR 2.202, Mr. James Francis Mattocks must, and any other person adversely affected by this Order may, submit an answer to this Order within 20 days of the date of this Order or other such time as may be specified in this Order. In addition, Mr. James Francis Mattocks and any other person adversely affected by this Order may request a hearing on this Order within 20 days of the date of this Order. Where good cause is shown, consideration will be given to extending the time to request a hearing. A request for extension of time must be made in writing to the Director, Office of Enforcement, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, and include a statement of good cause for the extension. The answer may consent to this Order. Unless the answer consents to this Order, the answer shall, in
5 writing and under oath or affirmation, specifically admit or deny each allegation or charge made in this Order and shall set forth the matters of fact and law on which Mr. James Francis Mattocks or other person adversely affected relies and the reasons as to why the Order should not have been issued. Any answer or request for a hearing shall be submitted to the Secretary, U.S. Nuclear Regulatory Commission, Attn: Rulemakings and Adjudications Staff, Washington, DC 20555-0001. Copies also shall be sent to the Director, Office of Enforcement, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, to the Assistant General Counsel for Materials Litigation and Enforcement at the same address, to the Regional Administrator, NRC Region II, 61 Forsyth Street, SW, Atlanta, GA, 30303, and to Mr. James Francis Mattocks if the answer or hearing request is by a person other than Mr. James Francis Mattocks. Because of continuing disruptions in delivery of mail to United States Government offices, it is requested that answers and requests for hearing be transmitted to the Secretary of the Commission either by means of facsimile transmission to 301-415-1101 or by e-mail to hearingdocket@nrc.gov and also to the Office of the General Counsel either by means of facsimile transmission to 301-415-3725 or by e-mail to OGCMail Center@nrc.gov. If a person other than the licensee requests a hearing, that person shall set forth with particularity the manner in which his interest is adversely affected by this Order and shall address the criteria set forth in 10 CFR 2.390(d).
If a hearing is requested by Mr. James Francis Mattocks or a person whose interest is adversely affected, the Commission will issue an Order designating the time and place of any hearing. If a hearing is held, the issue to be considered at such hearing shall be whether this Order should be sustained.
6 Pursuant to 10 CFR 2.202(c)(2)(I), Mr. James Francis Mattocks, may, in addition to demanding a hearing, at the time the answer is filed or sooner, move the presiding officer to set aside the immediate effectiveness of the Order on the ground that the Order, including the need for immediate effectiveness, is not based on adequate evidence but on mere suspicion, unfounded allegations, or error.
In the absence of any request for hearing, or written approval of an extension of time in which to request a hearing, the provisions specified in Section IV above shall be effective and final 20 days from the date of this Order without further order or proceedings. If an extension of time for requesting a hearing has been approved, the provisions specified in Section IV shall be final when the extension expires if a hearing request has not been received.
FOR THE NUCLEAR REGULATORY COMMISSION
/RA/
Martin J. Virgilio Deputy Executive Director for Materials, Waste, Research, State, Tribal, and Compliance Programs Office of the Executive Director for Operations Dated this 21st day of March 2007