March 8, 2007 MEMORANDUM TO: Frank Gillespie, Executive Director Advisory Committee on Reactor Safeguards FROM:
P. T. Kuo, Director /RA/
Division of License Renewal Office of Nuclear Reactor Regulation
SUBJECT:
ADVISORY COMMITTEE ON REACTOR SAFEGUARDS REVIEW OF THE OYSTER CREEK NUCLEAR GENERATING STATION, LICENSE RENEWAL APPLICATION - SAFETY EVALUATION REPORT During the Advisory Committee on Reactor Safeguards (ACRS) meeting on February 1, 2007, the Division of License Renewal (the staff) and the applicant discussed the results of a confirmatory analysis conducted by Sandia National Laboratories (SNL).
On February 13, 2007, the staff forwarded to the ACRS the attached e-mail from Mr. Michael F. Hessheimer, Manager, Systems & Structures, Dept. 6764, SNL.
Mr. Hessheimer managed the contract for the analysis conducted by SNL in support of the staffs evaluation of the Oyster Creek Nuclear Generating Station (Oyster Creek) license renewal request. In his e-mail to the staff, Mr. Hessheimer expressed concern about some of the staffs statements and one slide presented during the February 1, 2007, ACRS committee meeting. The staffs discussions and presentation during the meeting were associated with the Oyster Creek license renewal application. Specifically, Mr. Hessheimer was concerned about the staff statements which indicated that the SNL analysis did not include the effect of hoop tension in determining the minimum shell thickness.
As a follow-up to the staffs receipt and review of Mr. Hessheimers e-mail, a conference call was conducted by the staff with Mr. Hessheimer and Dr. Jason Petti, Sr. Member of the Technical Staff, SNL on February 16, 2007. The purpose of the conference call was for the staff to more fully understand Mr. Hessheimers concern. During the call, Mr. Hessheimer indicated that he was concerned that the slide information referenced above could have confused some ACRS members or the public. Mr. Hessheimer was concerned that the slide did not specify which portion of the SNL analysis did not include an analysis of the effect of hoop tension in determining the minimum shell thickness. The staff indicated that the purpose of the ACRS presentation was to explain differences between a 1990's General Electric (GE) and the 2006 SNL analyses. The 1990's GE analysis was performed for the licensee, was reviewed by the staff, and is the current licensing basis for Oyster Creek. The 2006 SNL analysis was performed as a confirmatory analysis for the staff as part of the staffs review of Oyster Creeks license renewal request.
Based upon our review of Mr. Hessheimers e-mail and our discussions with Mr. Hessheimer and Dr. Petti, the staff agreed with Mr. Hessheimer that both the SNL and the GE analyses considered the effects of hoop tension in determining the theoretical buckling load.
Mr. Hessheimer agreed with the staffs determination that the SNL analysis did not incorporate the effects of hoop tension to modify the capacity reduction factor.
F. Gillespie Mr. Hessheimer indicated that SNL did not have access to the test results used by Dr. Clarence Miller, to justify modification of the capacity reduction factor in the 1990's GE analyses and has no position on whether the data shared during the February 1, 2007, ACRS meeting satisfies use of the modified capacity reduction factor.
If you have any questions, please contact Donnie J. Ashley, the license renewal Project Manager for this application at 301-415-3191 or via e-mail at dja1@nrc.gov.
Docket No. 50-219
Enclosure:
As stated cc: See next page
Pkg: ML070670513;
Enclosure:
ML070430292; Ltr: ML070650376 DOCUMENT NAME: C:\\FileNet\\ML070650376.wpd
- Concurrence via email OFFICE PM:RLRA:DLR BC:DE:EEMA LA:DLR
- OGC (A)BC:RLRA:DLR D:DLR NAME DJAshley KAManoly IKing MAYoung (w/nlo)
RGSchaaf PTKuo DATE 03/07/07 03/08/07 03/07/07 03/08/07 03/08/07 03/08/07 Memo to F. Gillespie from P.T. Kuo, dated March 08, 2007
SUBJECT:
ACRS REVIEW OF THE OYSTER CREEK NUCLEAR GENERATING STATION, LICENSE RENEWAL APPLICATION - SAFETY EVALUATION REPORT HARD COPY DLR RF E-MAIL:
PUBLIC RWeisman GGalletti DShum SSmith (srs3)
Sduraiswamy RidsNrrAdro RidsNrrDlr RidsNrrDlrRlra RidsNrrDlrRlrb RidsNrrDlrRlrc RidsNrrDlrReba RidsNrrDlrRebb RidsNrrDci RidsNrrDra RidsNrrDe RidsNrrDeEemb RidsNrrDeEeeb RidsNrrDeEqvb RidsNrrDss RidsOgcMailCenter RidsNrrAdes CHolden RLaufer GMiller RBellamy, RI RCureton, RI JLilliendahl, RI MModes, RI MSykes, RI TMensah MYoung RidsOpaMail DJAshley RGSchaaf KAManoly
Oyster Creek Nuclear Generating Station cc:
Site Vice President - Oyster Creek Nuclear Generating Station AmerGen Energy Company, LLC P.O. Box 388 Forked River, NJ 08731 Senior Vice President of Operations AmerGen Energy Company, LLC 200 Exelon Way, KSA 3-N Kennett Square, PA 19348 Kathryn M. Sutton, Esq.
Morgan, Lewis, & Bockius LLP 1111 Pennsylvania Avenue, NW Washington, DC 20004 Kent Tosch, Chief New Jersey Department of Environmental Protection Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625 Vice President - Licensing and Regulatory Affairs AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406-1415 Mayor of Lacey Township 818 West Lacey Road Forked River, NJ 08731 Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 445 Forked River, NJ 08731 Director - Licensing and Regulatory Affairs AmerGen Energy Company, LLC Correspondence Control P.O. Box 160 Kennett Square, PA 19348 Manager Licensing - Oyster Creek Exelon Generation Company, LLC Correspondence Control P.O. Box 160 Kennett Square, PA 19348 Regulatory Assurance Manager Oyster Creek AmerGen Energy Company, LLC P.O. Box 388 Forked River, NJ 08731 Assistant General Counsel AmerGen Energy Company, LLC 200 Exelon Way Kennett Square, PA 19348 Ron Bellamy, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406-1415 Correspondence Control Desk AmerGen Energy Company, LLC 200 Exelon Way, KSA 1--1 Kennett Square, PA 19348 Oyster Creek Nuclear Generating Station Plant Manager AmerGen Energy Company, LLC P.O. Box 388 Forked River, NJ 08731 License Renewal Manager Exelon Generation Company, LLC 200 Exelon Way, Suite 230 Kennett Square, PA 19348
Oyster Creek Nuclear Generating Station cc: Mr. James Ross Nuclear Energy Institute 1776 I Street, NW, Suite 400 Washington, DC 20006-3708 Mr. Michael P. Gallagher Vice President License Renewal Exelon Generation Company, LLC 200 Exelon Way, Suite 230 Kennett Square, PA 19348 Mr. Christopher M. Crane President and Chief Nuclear Officer AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555 E. Roy Hawkens, Chair Administrative Judge Atomic Safety and Licensing Board Panel Mail Stop: T-3F23 U.S. Nuclear Regulatory commission Washington, DC 20555-0001 Anthony J. Baratta Administrative Judge Atomic Safety and Licensing Board Panel Mail Stop: T-3F23 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Paul B. Abramson Administrative Judge Atomic Safety and Licensing Board Panel Mail Stop: T-3F23 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Office of the Secretary ATTN: Docketing and Service Mail Stop: O-16C1 U.S. Nuclear Regulatory commission Washington, DC 20555-0001 Office of Commission Apellate Adjudication U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Debra Wolf Law Clerk Atomic Safety and Licensing Board Mail Stop: T-3F23 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Lisa P. Jackson, Acting Commissioner New Jersey Department of Environmental Protection P.O. Box 402 Trenton, NJ 08625-0402 Jill Lipoti, Director New Jersey Department of Environmental Protection Division of Environmental Safety and Health P.O. Box 424 Trenton, NJ 08625-0424 Ron Zak New Jersey Department of Environmental Protection Nuclear Engineering P.O. Box 415 Trenton, NJ 08625-0415 Suzanne Leta New Jersey Public Interest Research Group 11 N. Willow Street Trenton, NJ 08608 Donald Silverman, Esq.
Morgan, Lewis, & Bockius LLP 1111 Pennsylvania Avenue, NW Washington, DC 20004 Alex S. Polonsky, Esq.
Morgan, Lewis, & Bockius LLP 1111 Pennsylvania Avenue, NW Washington, DC 20004
Oyster Creek Nuclear Generating Station cc: Paul Gunter, Director Reactor Watchdog Project Nuclear Information And Resource Service 1424 16th Street, NW Suite 404 Washington, DC 20036 J. Bradley Fewell, Esq.
Exelon Corporation 4300 Warrenville Road Warrenville, IL 60555 John A. Covino, Esq.
Valerie Anne Gray, Esq.
Deputy Attorneys General Division of Law Environmental Permitting & Counseling Section Division of Law Hughes Justice Complex P.O. Box 093 Trenton, NJ 08625 Richard Webster, Esq.
Rutgers Environmental Law Clinic 123 Washington Street Newark, NJ 07102-5695