ML070520620

From kanterella
Jump to navigation Jump to search

License/Technical Specification Pgs - Amendment 172 Re Technical Specification to Adopt Task Force Traveler TSTF-484, Revision 0, Use of TS 3.10.1 for Scram Time Testing Activities, Using CLIIP Process
ML070520620
Person / Time
Site: Grand Gulf 
Issue date: 02/21/2007
From: Bhalchandra Vaidya
NRC/NRR/ADRO/DORL/LPLIV
To: Brian W
Entergy Operations
Vaidya B, NRR/DORL/LP4, 415-3308
Shared Package
ML070250464 List:
References
TAC MD3578
Download: ML070520620 (2)


Text

(b)

SERI is required to notify the NRC in writing prior to any change in (i) the terms or conditions of any new or existing sale or lease agreements executed as part of the above, authorized financial transactions, (ii) the GGNS Unit 1 operating agreement, (iii) the existing property insurance coverage for GGNS Unit 1 that wouldmaterially alter the representations and conditions set-forth in the Staff's Safety Evaluation Report dated December 19, 1988 attached to Amendment No.

54.

In addition, SERI is required to notify the-NRC of any action by a lessor or other successor in interest to SERI that may have an effect on the operation of the facility.

C.

The license shall be deemed to contain and is subject to the conditions specified in the Commission's regulations set forth in 10CFR Chapter I and is subject to all applicable provisions of the Act and to the rules, regulations, and orders of the Commission now or hereafter in effect; and is subject to the additional conditions specified or incorporated below:

(1)

Maximum Power Level Entergy Operations, Inc. is authorized to operate the facility at reactor core power levels not in excess of 3898 megawatts thermal (100 percent power) in accordance with the conditions specified herein.

(2)

Technical Specifications The Technical Specifications contained'in Appendix A and the Environmental Protection Plan contained in Appendix B, as revised through Amendment No.

172 are hereby incorporated into this license.

Entergy Operations, Inc. shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

The Surveillance Requirements (SRs) for Diesel Generator 12 contained in the Technical Specifications and listed below, are not required to be performed immediately upon implementation of Amendment No.

169.

The SRs listed below shall be successfully demonstrated at the next regularly scheduled performance.

SR 3.8.1.9, SR 3.8.1.10, and SR 3.8.1.14 4

Amendment Nb. 172

Inservice Leak and Hydrostatic Testing Operation 3.10.1 3.10 SPECIAL OPERATIONS 3.10.1 Inservice Leak and Hydrostatic Testing Operation LCO 3.10.1 The average reactor coolant temperature specified in Table 1.1-1 for MODE 4 may be changed to "NA,"

and operation considered not to be in MODE 3; and the requirements of LCO 3.4.10, "Residual. Heat Removal (RHR)

Shutdown Cooling System-Cold Shutdown," may be suspended, to allow reactor coolant temperature > 200°F:

For performance of an inservice leak or hydrostatic

test, As a consequence of maintaining adequate pressure for an inservice leak or hydrostatic test, or As a consequence of maintaining adequate pressure for control rod scram time testing initiated in conjunction with an inservice leak or hydrostatic test, provided the following MODE 3 LCOs are met:
a.

LCO 3.3.6.2, "Secondary Containment Isolation Instrumentation," Functions 1, 2,

3, 4,

and 5 of Table 3.3.6.2-1;

b.

LCO 3.6.4.1, "Secondary Containment";

c.

LCO 3.6.4.2, "Secondary Containment Isolation Valves (SCIVs)"; and

d.

LCO 3.6.4.3, "Standby Gas Treatment (SGT)

System."

APPLICABILITY:

MODE 4 with average reactor coolant temperature > 200 0 F.

GRAND GULF 3.10-1 Amendment No.

4-2-4, 172