ML070400479

From kanterella
Jump to navigation Jump to search
E-Mail from P. Hollenbeck of Entergy to J. Noggle of USNRC, Regarding Recent Sample Results
ML070400479
Person / Time
Site: Indian Point  Entergy icon.png
Issue date: 01/09/2007
From: Hollenbeck P
Entergy Corp
To: Noggle J
NRC/RGN-I/DRS/PSB2
References
FOIA/PA-2007-0080
Download: ML070400479 (2)


Text

11 iameý Noggle - Hecent sample results JamesNogge

- Hcentsampl.res.ts age 1_ Ii From:

To:

Date:

Subject:

"Hollenbeck, Peter" <phol191 @entergy.com>

"Jim Noggle (NRC)" <jdn@nrc.gov>

01/09/2007.1:14:25 PM Recent sample results Jim-Attached is a table of sample results that we have recently received and discussed this morning on the phone.

Pete

<<Recent sample results - NRC.pdf>>

CC:

"Adler, Joseph J." <jadler@entergy.com>, "Donahue, Patrick J"

<PDonahu @entergy.com>

Sb'

Latest Sample Results from Areva Sample MW-39-(005)

MW-41-42-(007)

MW-41-64-(006)

MW-42-41-(004)

MW-42-43-(004)

MW-42-46-(004)

MW-42-48-(004)

MW-45-43-(007)

MW-45-62-(007)

MW-49-25-(008)

MW-49-42-(008)

MW-49-65-(008)

MW-50-42-(008)

MW-50-67-(008)

MW-53-120-(002)

MW-53-80-(002)

MW-55-24-(001)

MW-55-35-(001)

MW-55-54-(001)

MW-56-85-(002)

MW-58-26-(001)

MW-58-65-(001)

MW-59-31 -(001)

MW-59-45-(001)

MW-59-68-(001)

Well ID MW-30-74-(005)

MW-30-88-(002)

MW-31-53-(001)

MW-31-67-(001)

MW-31-89-(001)

MW-60-200-(001)

MW-62-200-(001 LAF-001-(004)

LAF-002-(004)

LAF-003-(004)

Date Time Collected 11/17/06 13:49 11/13/06 12:55 11/13/06 13:10 11/17/06 8:44 11/16/06 14:25

.11/16/06 13:02 11/16/06 11:15 11/13/06 13:20 11/13/06 11:20 11/15/06 11:28 11/15/06 14:21 11/15/06 13:46 11/15/06 11:50 11/15/06 10:37 11/9/06 11:20 11/9/06 11:15 1119/06 13:20 11/9/06 13:40 11/9/06 13:30 11/9/06 10:20 11/16/06 13:25 11/16/06 13:18 11/16/06 11:05 11/16/06 11:18 11/16/06 11:30 Sample Date 11/29/2006 10:45 11/29/2006 14:30 11/27/2006 11:45 11/27/2006 12:10 11127/2006 12:20 11/30/2006 10:38 11/30/2006 13:35 12/4/2006 11:34 12/4/2006 13:38 12/4/2006 10:02 Cs-1 37 ND ND ND 6953 +/- 62 8615+/-38 7254 +/-44' 6917 +/-66 ND ND ND ND ND 7.2 +/- 2.8 ND ND ND ND ND ND ND 72.7 +/- 5.6 ND ND 37.4 +/- 5.8 114.8 +/- 7.4 H-3 ND 425 +/- 92 157 +/- 90 2260 +/- 760 2650 +/- 780 2310 +/- 780 1980 +/- 760 525 +/- 92 957 +/- 96 6390 +/- 920 6190 +/- 920 3040 +/- 800 1700 +/- 740 5050 +/- 880 7900 +/- 980 454 +/- 92 2000 +/- 740 9040 +/- 1000 13110 +/- 1120 165 +/-90 ND ND ND ND ND Ni-63 ND ND ND ND ND.

ND ND ND ND ND ND ND ND ND 27.1 +/-8.8 ND ND ND ND ND ND ND ND ND ND Sr-90 2.1 +/-0.5 4.6 +/- 0.6 2.1 +/-0.4 10 +/- 1.1 14.9 +/- 1.4 11.4 +/- 1.3 10.6 +/- 1.3 ND 1.7 +/- 0.5 15.5 +1-1.3 21.1 +/- 1.6 19.2 +/- 1.5 11.3+/-1 21.5 +/- 1.6 25 ND 16.6 +/- 1.6 40.4 +/- 3.2 22.8 +/- 0.9 ND ND ND ND ND ND Cs-137 3129 293.7 70 199 152 ND 49 ND 82 ND H-3 1.06E+05 1.01E+04 Ni-63 Sr-90 6890 Notes: ND = not detected, Blank = no results yet, Errors shown @ +/- 2S