COMPLY: V1.6.

3/18/

2 9:18 40 CFR Part 61 National Emission Standards for Hazardous Air Pollutants REPORT ON COMPLIANCE WITH THE CLEAN AIR ACT LIMITS FOR RADIONUCLIDE EMISSIONS FROM THE COMPLY CODE - VI.6.

Prepared by:

NIST NBSR Gaithersburg, MD D.R. Brown x5810 Prepared for:

U.S. Environmental Protection Agency Office of Radiation and Indoor Air Washington, DC 20460

.10L

COMPLY: V1.6.

2001 effluents SCREENING LEVEL 4 DATA ENTERED:

3/18/ 2 9:18 Release Rate Nuclide (curies/YEAR)

AR-41 8.810E+02 H-3 V

1.197E+03 Release height 30 meters.

Building height 20 meters.

The source and receptor are not on the same building.

Building width 100 meters.

Building length 100 meters.

STACK DISTANCES, FILE: wind2001 DIR N

NNE NE ENE E

ESE SE SSE S

ssw SW WsW W

WNW NW NNW Distance (meters) 1950.0 1410.0 1380.0 1320.0 720.0 540.0 495.0 615.0 1260.0 1350.0 480.0 400.0 400.0 400.0 500.0 870.0

COMPLY: V1-6.

3/18/

2 9:18 WINDROSE DATA, FILE: wr20(

Source of wind rose data:

Dates of coverage:

Wind rose location:

Distance to facility:

Percent calm:

0.03 Wind S]

FROM Frequency (mi N

0.050 14 NNE 0.050 NE 0.050 ii ENE 0.040 1i E

0.030 ESE 0.020 SE 0.030 SSE 0.050 S

0.110 1

SSW 0.120 1

SW 0.060 WSW 0.040 W

0.040 WNW 0.090 1

NW 0.110 1

NNW 0.080 1

from NBSR-9 1960-1986 1960-1986 nat'l airport 20 mi peed les/hr) 0.00 1.00 0.00 0.00 9.00 9.00 9.00 9.00 0.00 0.00 8.00 8.00 9.00 3.00 1.00 1.00 He produces his own VEGETABLES at home.

He produces his own MILK at home.

He produces his own MEAT at home.

NOTES:

The receptor exposed to the highest concentration is located 495. meters from the source in the SE sector.

He produces his own VEGETABLES at his home.

He produces his own MEAT at his home.

He produces his own MILK at his home.

Input parameters outside the "normal" range:

Stack file distance is unusually FAR.

COMPLY: V1.6.

3/18/

2 9:18 RESULTS:

Effective dose equivalent:

0.6 mrem/yr.

      • Comply at level 4.

This facility is in COMPLIANCE.

It may or may not be EXEMPT from reporting to the EPA.

You may contact your regional EPA office for more information.

END OF COMPLIANCE REPORT

COMPLY: V1.6.

2/11/2003 11:28 40 CFR Part 61 National Emission Standards for Hazardous Air Pollutants REPORT ON COMPLIANCE WITH THE CLEAN AIR ACT LIMITS FOR RADIONUCLIDE EMISSIONS FROM THE COMPLY CODE - V1.6.

Prepared by:

NIST NBSR Gaithersburg, MD D.R. Brown x5810 N

VA-

\\

-A' Prepared for:

U.S. Environmental Protection Agency Office of Radiation and Indoor Air Washington, DC 20460

COMPLY: V1.6.

2/11/2003 11:28 CY 2002 SCREENING LEVEL 4 DATA ENTERED:

Release Rate Nuclide (curies/YEAR)

AR-41 1.171E÷03 H-3 V

7.470E+02 Release height 30 meters.

Building height 20 meters.

The source and receptor are not on the same building.

Building width 100 meters.

Building length 100 meters.

STACK DISTANCES, FILE: wind2001 DIR N

NNE NE ENE E

ESE SE SSE S

SSW SW Wsw W

WNW NW NNW Distance (meters) 1950.0 1410.0 1380.0 1320.0 720.0 540.0 495.0 615.0 1260.0 1350.0 480.0 400.0 400.0 400.0 500.0 870.0

COMPLY: V1.6-2/11/2003 11:28 WINDROSE DATA, FILE: wr20C Source of wind rose data:

Dates of coverage:

wind rose location:

Distance to facility:

Percent calm:

0.03 Wind S

FROM Frequency (mi:

N 0.050 1

N" 0.050 1

NE 0.050

.1 ENE 0.040 1

E 0.030 ESE 0.020 SE 0.030 SSE 0.050 S

0.110 I1 SSW 0.120 II SW 0.060 WSW 0.040 W

0.040 WNW 0.090 1I NW 0.110 1I NNW 0.080 1'

from NBSR-9 1960-1986 1960-1986 nat'l airport 20 mi peed Les/hr) 0.00 1.00 0.00 0.00 9.00 9.00 9.00 9.00 0.00 0.00 8.00 8.00 9.00 3.00 1.00 1.00 He He He NOTES:

produces produces produces his his his own own own VEGETABLES at home.

MILK at home.

MEAT at home.

The receptor exposed to the highest concentration is located 495. meters from the source in the SE sector.

He produces his own VEGETABLES at his home.

He produces his own MEAT at his home.

He produces his own MILK at his home.

Input parameters outside the "normal" range:

Stack file distance is unusually FAR.

COMPLY: V1.6.

2/11/2003 11:28 RESULTS:

Effective dose equivalent:

0.8 mrem/yr.

Comply at level 4.

This facility is in COMPLIANCE.

It may or may not be EXEMPT from reporting to the EPA.

You may contact your regional EPA office for more information.

  • END OF COMPLIANCE REPORT

COMPLY: V1.6.

1/12/2004 12:04 40'CFR Part 61 National Emission Standards for Hazardous Air Pollutants REPORT ON COMPLIANCE WITH THE CLEAN AIR ACT LIMITS FOR RADIONUCLIDE EMISSIONS FROM THE COMPLY CODE V1.6.

Prepared by:

NIST NCNR/'

/

Bldg 235 D.Brown 301-975-5810 Prepared for:

U.S. Environmental Protection Agency Office of Radiation and Indoor Air Washington, DC 20460

COMPLY: V1.6.

12:04 NBSR 2003 SCREENING LEVEL 4 DATA ENTERED:

1/12/2004 Nuclide 14-3 V

AR-41 Release Rate (curies/YEAR) 1.030E+03 1.078E÷03 Release height 30 meters.

Building height 20 meters.

The source and receptor are not on the same building.

Building width 100 meters.

Building length 100 meters.

STACK DISTANCES, FILE: wind2001 DIR N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW Distance (meters) 1950.0 1410.0 1380.0 1320.0 720.0 540.0 495.0 615.0 1260.0 1350.0 480.0 400.0 400.0 400.0 500.0 870.0

COMPLY: V1.6.

12:04 1/12/2004 WINDROSE DATA, FILE: w Source of wind rose da Dates of coverage:

Wind rose location:

Distance to facility:

Percent calm:

0.03 Wind FROM Frequency N

0.050 NNE 0.050 NE 0.050 ENE 0.040 E

0.030 ESE 0.020 SE 0.030 SSE 0.050 S

0.110 SSW 0.120 SW 0.060 WSW 0.040 W

0.040 WNW 0.090 NW 0.110 NNW 0.080 ta: from NBSR-9 1960-1986 1960-1986 nat'l airport 20 mi Speed (miles/hr) 10.00 11.00 10.00 10.00 9.00 9.00 9.00 9.00 10.00 10.00 8.00 8.00 9.00 13.00 11.00 11.00 He produces He produces He produces NOTES:

his own VEGETABLES at home.

his own MILK at home.

his own MEAT at home.

The receptor exposed to the highest concentration is located 495. meters from the source in the SE sector.

He'produces his own VEGETABLES at his home.

He produces his own MEAT at his home.

He produces his own MILK at his home.

Input-parameters outside the "normal" range:

Stack file distance is unusually FAR.

COMPLY: V1.6.

1/12/2004 12:04 RESULTS:

Effective dose equivalent:

0.7 mrem/yr.

Comply at level 4.

This facility is in COMPLIANCE.

It may or may not be EXEMPT from reporting to the EPA.

You may contact your regional EPA office for more information.

END OF COMPLIANCE REPORT **********

COMPLY : V1.6.

1/13/2006 12:23 40 CFR Part 61 National Emission Standards for Hazardous Air Pollutants REPORT ON COMPLIANCE WITH THE CLEAN AIR ACT LIMITS FOR RADIONUCLIDE EMISSIONS FROM THE COMPLY CODE

- V1.6.

Prepared by:

NIST NBSR Gaithersburg, MD D. Brown 4

x5810 Prepared for:

U.S. Environmental Protection Agency Office of Radiation and Indoor Air Washington, DC 20460 "b

COMPLY : V1.6.

1/13/2006 12:23 2005 NBSR Releases SCREENING LEVEL 4 DATA ENTERED:

Release Rate Nuclide (curies/YEAR)

H-3 V

7.870E+02 AR-41 1.163E+03 Release height 30 meters.

Building height 20 meters.

The source and receptor are not on the same building.

Building width 100 meters.

Building length 100 meters.

STACK DISTANCES, FILE: wind2001 DIR N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW Distance (meters) 1950.0 1410.0 1380.0 1320.0 720.0 540.0 495.0 615.0 1260.0 1350.0 480.0 400.0 400.0 400.0 500.0 870.0

COMPLY: V1.6.

1/13/2006 12:23 WINDROSE DATA, FILE: wr20(

Source of wind rose data:

Dates of coverage:

Wind rose location:

Distance to facility:

Percent calm:

0.03 Wind S1 FROM Frequency (mi]

N 0.050 I(

NNE 0.050 1

NE 0.050 I1 ENE 0.040 I(

E 0.030 ESE 0.020 5

SE 0.030 SSE 0.050 S

0.110 iC SSW 0.120 iC SW 0.060 8

WSW 0.040 W

0.040 5

WNW 0.090 13 NW 0.110

-I]

NNW 0.080 11 from NBSR-9 1960-1986 1960-1986 nat'l airport 20 mi seed Les/hr)

.00 1.00 0.00 3.00

).00 9.00

.00

).00 3.00 3.00

[.00

.00

.00

.00 L.00

.00 He He He NOTES:

produces produces produces his his his own own own VEGETABLES at home.

MILK at home.

MEAT at home.

The receptor exposed to the highest concentration is located 495. meters from the source in the SE sector.

He produces his own VEGETABLES at his home.

He produces his own MEAT at his home.

He produces his own MILK at his home.

Input parameters outside the "normal" range:

Stack file distance is unusually FAR.

COMPLY: V1.6.

1/13/2006 12:23 RESULTS:

Effective dose'equivalent:

0.8 mrem/yr.

Comply at level 4.

This facility is in COMPLIANCE.

It may or may not be EXEMPT from reporting to the EPA.

You may contact your regional EPA office for more information.

END OF COMPLIANCE REPORT *****

COMPLY: V1.6.

1/27/2005 9:49 40 CFR Part 61 National Emission Standards for Hazardous Air Pollutants REPORT ON COMPLIANCE WITH THE CLEAN AIR ACT LIMITS FOR RADIONUCLIDE EMISSIONS FROM THE COMPLY CODE -

VI.6.

Prepared by:

NIST NBSR Bldg 235 D. Brown 301-975-5810 Prepared for:

U.S. Environmental Protection Agency Office of Radiation and Indoor Air Washington, DC 20460

COMPLY: VI.6.

1/27/2005 9:49 NBSR CY2005 SCREENING LEVEL 4 DATA ENTERED:

Release Rate Nuclide (curies/YEAR)

H-3 V

1.358E+03 AR-41 9.470E+02 Release height 30 meters.

Building height 20 meters.

The source and receptor are not on-the same building.

Building width 100 meters.

Building length 100 meters.

STACK DISTANCES, FILE: wind2001 Distance DIR (meters)

N 1950.0 NNE 1410.0 NE 1380.0 ENE 1320.0 E

720.0 ESE 540.0 SE 495.0 SSE 615.0 S

1260.0 SSW 1350.0 SW 480.0 WSW 400.0 W

400.0 WNW 400.0 NW 500.0 NNW 870.0

COMPLY: V1.6.

1/27/2005 9:49 RESULTS:

Effective dose equivalent:

0.7 mrem/yr.

Comply at level 4.

This facility is in COMPLIANCE.

It may or may not be EXEMPT from reporting to the EPA.

You may contact your regional EPA office for more information.

END OF COMPLIANCE REPORT *