4 zz~'Dominionll Dominion Energy Kewaunee, Inc.
N490 Highway 42, Kewaunee, WI 54216-9511 JAN 1 9 2007 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555 DOMINION ENERGY KEWAUNEE, INC.
KEWAUNEE POWER STATION EMERGENCY RESPONSE DATA SYSTEM Serial No.
06-1088 KPS/LIC/NW: RO Docket No.
50-305 License No.
DPR-43 Pursuant to 10 CF 'R 50 Appendix E, Dominion Energy Kewaunee, Inc. hereby submits a copy of the Emergency Response Data System (ERDS) data point library, Figures EPMPFG-09.05-07 and EPMPFG-09.05-08, and Index EPMPFG-09.05-00 from Kewaunee Power Station procedure EPMP 9.5, "Control of ERDS Hardware and Software." In accordance with NUREG-1 394, this submittal is being sent to ensure the NRC data library used for ERDS has incorporated the revisions to these three figures.
Pursuant to 10 CFR 50.4, one copy of this letter and attachments are hereby submitted to the Regional Administrator, U. S. Nuclear Regulatory Commission (NRC), Region 111, Lisle, Illinois. As required, one copy of this letter and attachments are also submitted to the Kewaunee Power Station NRC Senior Resident Inspector.
If you have questions or require additional information, please feel free to contact Mr.
Jerry Riste at 920-388-8424.
Very truly yours, Site Vice President, Kewaunee Power Station Attachments Commitments made by this letter: NONE ACL2p
Serial No. 06-1 088 Page 2 of 2 cc:
Regional Administrator U. S. Nuclear Regulatory Commission Region Ill 2443 Warrenville Road Suite 210 Lisle, Illinois 60532-4352 NRC Senior Resident Inspector Kewaunee Power Station Ms. Karen B. Jackson Incident Response Operation U. S. Nuclear Regulatory Commission Two White Flint North MS 4A45 11545 Rockville Pike Rockville, MID 20852-2738
ERDS DATA POINT LIBRARY TABLE INDEX KEWAUNEE NUCLEAR POWER PLANT TABLE NUMBER POINT ID GENERIC DESCRIPTION
)
1 N8020G NUCLEAR INSTRUMENTS - POWER RANGE 2
N7035G NUCLEAR INSTRUMMENTS - INTERMEDIATE RANGE 3
N803IG NUCLEAR INSTRUMENTS - SOURCE RANGE 4
L8024G REACTOR VESSEL WATER LEVEL 5
- 111000, HIGHEST TEMPERATURE AT THE CORE EXIT 6
T0020G SATURATION TEMPERATURE - HIGHEST CET 7
F8007G REACTOR COOLANT FLOW LOOP A 8
F8008G REACTOR COOLANT FLOW LOOP B 9
L8013G STEAM GENERATOR A WATER LEVEL 10 L80 140 STEAM GENERATOR B WATER LEVEL I11 P802I10 STEAM GENERATOR A PRESSURE 12 P8022G STEAM GENERATOR B PRESSURE 13 F8009G STEAM GENERATOR A MAIN FEEDWATER FLOW 14 F801OG STEAM GENERATOR B MAIN FEEDWATER FLOW 15 F8003A STEAM GENERATOR A AUXILIARY FW FLOW 16 F8004A STEAM GENERATOR B AUXILIARY FW FLOW 17 T0419A STEAM GENERATOR A INLET TEMPERATURE 18 T0439A STEAM GENERATOR B INLET TEMPERATURE 19 T0406A STEAM GENERATOR A OUTLET TEMPERATURE 20 T0426A STEAM GENERATOR B OUTLET TEMPERATURE 21 P8023G REACTOR COOLANT SYSTEM PRESSURE 22 L80 150 PRIMARY SYSTEM PRESSURIZER LEVEL 23 F0128G PRIMARY SYSTEM CHARGING FLOW 24 F8001 G HIGH PRESSURE SAFETY INJECTION FLOW - PUMP A 25 F8002G HIGH PRESSURE SAFETY INJECTION FLOW - PUMP B 26 F0626A LOW PRESSURE SAFETY INJECTION FLOW 27 NOT AVAIL.
CONTAINMENT SUMP NARROW RANGE LEVEL 28 L8001A CONTAINMENT SUMP WIDE RANGE LEVEL 29 000140 RADIOACTIVITY OF RELEASED GASSES 30 000180 RADIOACTIVITY OF RELEASED LIQUIDS 31 000150 CONDENSER AIR EJECTOR RADIOACTIVITY 32 000400 RADIATION LEVEL IN CONTAINMENT 33 000090 RADIOACTIVE LEVEL OF RCS LETDOWN LINE 34 000320 STEAM GENERATOR A STEAM LINE RADIATION LEVEL 35 000340 STEAM GENERATOR B STEAM LINE RADIATION LEVEL 36 000190 STEAM GENERATOR BLOWDOWN RADIATION LEVEL 37 P8004A CONTAINMENT PRESSURE 38 TIOOOA CONTAINMENT TEMPERATURE 39 X8001 A CONTAINMENT HYDROGEN CONCENTRATION 40 L8008A BORATED WATER STORAGE TANK LEVEL 41 MOO0lA WIND SPEED AT REACTOR SITE 42 M0002G WIND DIRECTION AT REACTOR SITE 43 M0004A AIR STABILITY AT REACTOR SITE 44 ERDSDATATYPE ERDS PLANT/SIMULATOR DATA Table - ERDS INDEX EPMVP-09.05 Rev. B Date: JAN 13 2005 REFERENCE USE Page 4 of 48
4 REACTOR COOLANT FLOW LOOP A KEWAUNEE: POWER STATION ITEM FIELD PED AT LENGTHKPEDSAT DATE:
(8) 05/26/95 REACTOR UNIT:
(3)
KWI DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
CORE FLOW POINT ID:
(12)
(40)
RCLA AVERAGE FLOW (LOOP A)
GNERIC/COND DESC:
(32)
REACTOR COOLANT FLOW LOOP A ANALOG/DIGITAL:
(1)
A (A, D)
ENGR UNITS/DIG ST:
(12)
PCT ENGR UNITS CON VERS:
(40)
N/A MIN INSTR RANGE:
(10) 0 MAX INSTR RANGE:
(10) 110 ZERO PT REF:
(6)
N/A REF PT NOTES:
(40)
N/A PROC OR SENS:
(1)
P (P, S)
NUMBER OF SENSORS:
(3) 3 HOW PROCESSED:
(40)
AVERAGE SENSOR LOCATIONS:
(40)
CONTAINMENT ALARMITRIP SET PT:
(40) 90% REACTOR TRIP NI DET PWR SUPPLY CUTOFF PWR LVL:
(15)
N/A NI DET PWR SUPPLY TURN ON PWR LVL:
(15)
N/A INSTR FAIL MODE:
(30)
LOW TEMP COMIP FOR DP XMTRS:
(3)
N (Y, N, N/A)
LEVEL REF LEG:
(3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
INSTRUMENTS:
FT-41 1, FT-412, FT-413.
I 0001 FLOW = 95.948 GPM (NOTE: THIS NUMBER WELL CHANGE ANNUALLY BASED ON S/G TUBE PLUGGING OR SLEEVING PERFORMED.)
Figure EPMPFG-09.05-07 Rev. N Date: DEC 21 2006 Page 1 of 1 REFERENCE USE
-4 REACTOR COOLANT FLOW LOOP B KFEWAUNEE 1-'OWE-'R STATION ITEM FIELD P
RSDT LENGTHKPEDSAT DATE:
(8) 05/26/95 REACTOR UNIT:
(3)
KWI DATA FEEDER:
(10)
N/A NRC ERDS PARAM:
(12)
CORE FLOW POINT ID:
(12)
(40)
RCLB AVERAGE FLOW (LOOP B)
GENERIC/COND DESC:
(32)
REACTOR COOLANT FLOW LOOP B ANALOG/DIGITAL:
(1)
A (A, D)
ENGR UNITS/DIG ST:
(1.2)
PCT ENGR UNITS CONVERS:
(40)
N/A MIN INSTR RANGE:
(10) 0 MAX INSTR RANGE:
(10) 110 ZERO PT REP:
(6)
N/A REF PT NOTES:
(40)
N/A PROC OR SENS:
(1)
P (P, S)
NUMBER OF SENSORS:
(3) 3 HOW PROCESSED:
(40)
AVERAGE SENSOR LOCATIONS:
(40)
CONTAINMENT ALARM/ITRTP SET PT:
(40) 90% REACTOR TRIP NI DET PWR SUPPLY CUTOFF PWR LVL:
(15)
N/A NI DET PWR SUPPLY TURN ON PWR LVL:
(15)
N/A INSTR FAIL MODE:
(30)-
LOW TEMP COMP FOR DP XMTRS:
(3)
N (Y, N, N/A)
LEVEL REF LEG:
(3)
N/A (DRY, WET)
UNIQUE SYS DESC:
(600)
INSTRUMENTS:
FT-4 14, FT-4 15, FT-4]6.
100% FLOW = 99.647 GPM (NOTE: THIS NUMBER WILL CHANGE ANNUALLY BASED ON S/G TUBE PLUGGING OR SLEEVING PERFORMED.)
Figure EPMPFG-09.05-08 Rev. N Date: DEC 21 2006 Pagel1 of 1 REFERENCE USE