OAK RIDGE INSTITUTE FOR SCIENCE AND EDUCATION RECEIVED REG!OM 1 Mr. Jim Kottan U.S. Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406
SUBJECT:
REPORT FOR REQUESTED REANALYSES OF ONE VEGETATION SAMPLE FOR NICKEL-63, SET SEVEN, COLLECTED BETWEEN JUNE 14 AND JUNE 22,2006 FROM THE INDIAN POINT POWER STATION, BUCHANAN, NEW YORK
[INSPECTION REPORT NO. 050-247/2006-0071 [RFTA NO. 06-0011
Dear Mr. Kottan:
The Oak Ridge Institute for Science and Education (ORISE) received set seven, consisting of four water samples and two vegetation samples on June 28,2006 and two additional water samples received on June 30,2006, from the Indian Point Power Station in Buchanan, New York. On September 12,2006, ORISE received a request to reanalyze the vegetation samples from Lents Cove for Ni-63. The sample was reanalyzed in triplicate. The sample identification and collection data for this sample addressed in this report are presented in Table 1. The Ni-63 data are provided in Table 2. The pertinent procedure references are provided in each specific table.
ORISEs Quality Control (QC) requirements were met for these analyses. The QC files are available for your review upon request. Additional reports will follow after the completion of the requested analyses.
My contact information is listed below. You may also contact Wade h e y at 865.576.9184 with any questions or comments.
Sincerely, Dale Condra, Manager Laboratory RDCWPI: ar Enclosures cc:
B. Watson, NMSS/DWMEP/DD/SP 7E18 E. Abelquist, ORISE E. Ikox-Davin, NRC/NMSS/TWFN SA23 M. Miller, NRC Region I File 1697 S. Kirk, ORISE J. m t e, NRC Region I Distribution approval and concurrence :
Technical Management Team Member
[ Initials 7 I Quality Manager Voice: 865.241.3242 Fax: 865.241.3248 E-mail: CondraD@orau.gov
TABLE 1 ORISE Sample ID 1697V0002 SAMPLE IDENTIFICATION AND COLLECTION DATA INDIAN POINT POWER STATION BUCHANAN, NEW YORK NRC Region I Collection Collection Sample ID Date Time Lent's Cove 6/14/06 10:20 Indian Point Power Station projects/l697/Data Tables/2006-10-11 Ni-63 Reanalysis Data Tables
TABLE 2 ORISE Sample ID CONCENTRATIONS OF NICKEL-63 (Ni-63)
IN A VEGETATION SAMPLE BY LIQUID SCINTILLATION ANALYSIS AI? 17, REVISION 0; CP4, REVISION 3 INDIAN POINT POWER STATION BUCHANAN, NEW YORK Radionuclide Concentrationsa (pCi/g)
NRC Region I Sample ID It I
I 1i 1697V0002 1697V0002 Ni-63 Lent's Cove 0.06 k 0.12b (0.20)
Lent's Cove 0.01 k 0.11 (0.19) 11 1697V0002 I Lent's Cove I 0.02 k 0.12 (0.20) 11
~~
%e MDCs for each radionuclide are in parentheses.
eUncertaindes represent the 95% confidence level, based on total propagated uncertaintics Indian Point Power Station projects/l697/Data Tables/2006-10-11 Ni-63 Reanalysis Data Tables