January 5, 2007 Carolina Power and Light Company ATTN:

Mr. J. Scarola Vice President Brunswick Steam Electric Plant P. O. Box 10429 Southport, NC 28461

SUBJECT:

BRUNSWICK STEAM ELECTRIC PLANT, NOTIFICATION OF INSPECTION AND REQUEST FOR INFORMATION

Dear Mr. Scarola:

On March 5-9, 2007 and March 19-23, 2007, the NRC will perform the baseline Occupational Radiation Safety Inspection at Brunswick (NRC Inspection Procedures 71121.01, 71121.02, and 71122.02, and radiation safety portions of 71151). Experience has shown that this inspection is resource intensive both for the NRC inspectors and your staff. In order to minimize the impact to your on-site resources and to ensure a productive inspection, we have enclosed a request for documents needed for this inspection. It is important that all of these documents are up-to-date and complete, in order to minimize the number of additional documents requested during the preparation and/or the onsite portions of the inspection. The lead inspector has scheduled a two-day pre-inspection visit with your staff for February 6-8, 2007. The material requested will be reviewed and collected at that time.

We have discussed the schedule for these inspection activities with your staff and understand that our regulatory contact for this inspection will be Mr. Lee Grzeck of your organization. If there are any questions about this inspection or the material requested, please contact the lead inspector, Heather Gepford, at (404) 562-4659.

In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS).

CP&L 2

ADAMS is accessible from the NRC Web site at http://www.nrc.gov/ reading-rm/adams.html (the Public Electronic Reading Room).

Sincerely,

/RA/

Brian Bonser, Chief Plant Support Branch 1 Division of Reactor Safety Docket Nos. 50-325, 50-324 License Nos. DPR-71, DPR-62

Enclosure:

Occupational Radiation Protection Inspection Document Request cc w/encl: (See page 3)

CP&L 3

T. P. Cleary, Director Site Operations Brunswick Steam Electric Plant Progress Energy Carolinas, Inc.

Electronic Mail Distribution Benjamin C. Waldrep Plant Manager Brunswick Steam Electric Plant Carolina Power & Light Company Electronic Mail Distribution James W. Holt, Manager Performance Evaluation and Regulatory Affairs PEB 7 Carolina Power & Light Company Electronic Mail Distribution Edward T. O'Neil, Manager Training Carolina Power & Light Company Brunswick Steam Electric Plant Electronic Mail Distribution Randy C. Ivey, Manager Support Services Carolina Power & Light Company Brunswick Steam Electric Plant Electric Mail Distribution Garry D. Miller, Manager License Renewal Progress Energy Electronic Mail Distribution Annette H. Pope, Supervisor Licensing/Regulatory Programs Carolina Power and Light Company Electronic Mail Distribution David T. Conley Associate General Counsel - Legal Dept.

Progress Energy Service Company, LLC Electronic Mail Distribution James Ross Nuclear Energy Institute Electronic Mail Distribution John H. O'Neill, Jr.

Shaw, Pittman, Potts & Trowbridge 2300 N. Street, NW Washington, DC 20037-1128 Beverly Hall, Chief, Radiation Protection Section N. C. Department of Environment and Natural Resources Electronic Mail Distribution Peggy Force Assistant Attorney General State of North Carolina Electronic Mail Distribution Chairman of the North Carolina Utilities Commission c/o Sam Watson, Staff Attorney Electronic Mail Distribution Robert P. Gruber Executive Director Public Staff NCUC 4326 Mail Service Center Raleigh, NC 27699-4326 Public Service Commission State of South Carolina P. O. Box 11649 Columbia, SC 29211 David R. Sandifer Brunswick County Board of Commissioners P. O. Box 249 Bolivia, NC 28422 Warren Lee Emergency Management Director New Hanover County Department of Emergency Management P. O. Box 1525 Wilmington, NC 28402-1525

OFFICE RII:DRS RII:DRP SIGNATURE RA RA NAME B.Bonser R. Musser DATE 1/5/2007 1/5/2007 1/ /2007 1/ /2007 1/ /2007 1/ /2007 1/ /2007 E-MAIL COPY?

YES NO YES NO YES NO YES NO YES NO YES NO YES NO

Enclosure PUBLIC RADIATION PROTECTION INSPECTION DOCUMENT REQUEST Pre-Inspection Visit:

February 6-8, 2007 Inspection Dates:

March 5-9, 2007 and March 19-23, 2007 Inspection Procedures:

IP 71121.01 Access Control To Radiologically Significant Areas IP 71121.02 ALARA Planning and Controls IP 71122.02 Radioactive Material Processing & Transportation IP 71151 Performance Indicator Verification (Occupational/

Public Radiation Safety Cornerstones)

Note: This is a broad list of the documents the lead NRC inspector will be interested in reviewing and obtaining during the pre-inspection visit. The current version of these documents is expected unless specified otherwise. Electronic media is preferred, if readily available. (The preferred file format is Word, WordPerfect, or searchable Adobe Acrobat (.pdf).) Information in the following document list should contain enough information to be easily understood by someone who has a knowledge of the subject. The lead inspector will discuss specific information needs with the licensee staff and may request additional documents.

Miscellaneous

1. Current organization chart for HP/Chemistry/Radwaste/Shipping with contact numbers.
2. Corrective action program procedure.
3. Outage schedule of major activities (Gantt chart if available).
4. HP Manual.

Access Controls

1. Plant maps of all Locked HRAs and VHRAs.
2. Procedures related to HP/access controls (e.g. posting, labeling, surveys, RWPs, contamination control, dosimetry, multi-dosimetry, key control, control of divers, controls during fuel offload, etc.)
3. List of all non-fuel items stored in spent fuel pool (both units).
4. Internal dose assessments for intakes where dose was assigned since September 2006.
5. Documentation associated with any skin contaminations > 1 rem SDE, since September 2006.
6. Most recent self-assessment or audit of access control program.
7. List of CRs related to access controls (including poor radworker or HP tech performance) issued since September 2006.

ALARA

1. All procedures related to HP/ALARA not listed above (e.g. declared pregnant worker, shielding, ALARA planning, etc.).
2. All procedures related to crudburst & cleanup.
3. ALARA manual (or equivalent high-level procedure).
4. List of top 5 dose jobs for refueling outage and ALARA planning packages if available.

2 Enclosure

5. Crudburst & cleanup trending point data from previous outage (dose rates and cobalt concentration). Data should be from the same unit as the current outage.
6. Source term reduction program guidance, including cobalt reduction.
7. List of CRs related to ALARA since April 2005.
8. Most recent annual ALARA report, or equivalent.
9. Most recent self-assessment or audit of ALARA program.

Shipping & Radwaste

1. All procedures related to transportation and solid radwaste processing.
2. Current PCP.
3. List of all shipments made since April 2005.
4. List of all changes made to solid and liquid radwaste processing systems since April 2005.
5. List of all permanently abandoned solid and liquid radwaste processing equipment.
6. Last two 10 CFR Part 61 analyses for each waste stream.
7. List of CRs related to shipping or radwaste since April 2005.
8. Most recent self-assessment or audit of Shipping/Radwaste Processing program.

PI Verification (occupational and public radiation safety cornerstones)

1. Procedure for gathering and reporting PI data.
2. List of all CRs since July 2006 using keywords: HRA, LHRA, VHRA, unintended dose, unlocked door, offsite dose, ODCM, etc. Note: you dont need to duplicate any CRs that overlap with access controls.
3. Monthly PI reports since July 2006.
4. List of all dose rate alarms >1R/hr since July 2006.
5. List of all dose alarms since July 2006.
6. All final release point effluent monitor out-of-service dates since July 2006.
7. Most recent gaseous and liquid effluent release permits.
8. 2006 Annual Effluent Report.

Lead Inspector Contact Information:

Heather Gepford, CHP (404) 562-4659 hjg1@nrc.gov Mailing Address US NRC Region II ATTN: Heather Gepford 61 Forsyth Street, SW Suite 23T85 Atlanta, GA 30303-3415