Text
January 12, 2007 Mr. James M. Levine Executive Vice President, Generation Arizona Public Service Company P.O. Box 52034 Phoenix, AZ 85072-2034
SUBJECT:
PALO VERDE NUCLEAR GENERATING STATION, UNITS 1, 2, AND 3 -
CLOSEOUT OF GENERIC LETTER 2006-01, STEAM GENERATOR TUBE INTEGRITY AND ASSOCIATED TECHNICAL SPECIFICATIONS (TAC NOS. MD0096, MD0097, AND MD0098)
Dear Mr. Levine:
On January 20, 2006, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2006-01, Steam Generator [SG] Tube Integrity and Associated Technical Specifications
[TSs] (Agencywide Document Access and Management System (ADAMS) Accession No. ML060200385). This GL requested that addressees either submit a description of their program for ensuring SG tube integrity for the interval between inspections or adopt alternative TS requirements for ensuring SG tube integrity.
By letter dated February 9, 2006 (ADAMS Accession No. ML060520483), Arizona Public Service Company (the licensee) responded to GL 2006-01 for the Palo Verde Nuclear Generating Station (Palo Verde), Units 1, 2, and 3. This response stated that by application dated May 26, 2005 (ADAMS Accession No. ML051520413), the licensee requested changes to the TSs for the Palo Verde units to adopt the alternative TS requirements for ensuring SG tube integrity. The alternative TS requirements were modeled after Technical Specification Task Force (TSTF) Traveler, TSTF-449, Steam Generator Tube Integrity, Revision 4 (ADAMS Accession No. ML051090200).
On July 27, 2006 (ADAMS Accession No. ML062090296), the NRC staff issued TS amendments approving SG TSs modeled after TSTF-449, Revision 4, for the Palo Verde units.
J. M. Levine The NRC staff finds the licensees adoption of new SG TSs modeled after TSTF-449 to be an acceptable and complete response to GL 2006-01. This completes the NRC staffs efforts on TAC Nos. MD0096, MD0097, and MD0098. If you have any questions regarding this letter, please contact me at (301) 415-3062.
Sincerely,
/RA/
Mel B. Fields, Senior Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. STN 50-528, STN 50-529, and STN 50-530 cc: See next page
J. M. Levine The NRC staff finds the licensees adoption of new SG TSs modeled after TSTF-449 to be an acceptable and complete response to GL 2006-01. This completes the NRC staffs efforts on TAC Nos. MD0096, MD0097, and MD0098. If you have any questions regarding this letter, please contact me at (301) 415-3062.
Sincerely,
/RA/
Mel B. Fields, Senior Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. STN 50-528, STN 50-529, and STN 50-530 cc: See next page DISTRIBUTION:
PUBLIC LPLIV r/f RidsAcrsAcnwMailCenter RidsNrrDprPgcb RidsNrrDorlLpl4 RidsNrrLAJBurkhardt RidsNrrPMMFields RidsNrrDorl (CHaney/JLubinski)
RidsRgn4MailCenter RidsOgcRp DBeaulieu, NRR ADAMS Accession No.: ML070040257 OFFICE NRR/LPL4/PM NRR/LPL4/LA NRR/CSGB/BC NRR/LPL4/BC NAME MFields LFeizollahi AHiser DTerao DATE 1/8/07 1/4/07 1/10/07 1/12/07 OFFICIAL AGENCY RECORD
May 2006 Palo Verde Nuclear Generating Station cc:
Mr. Steve Olea Arizona Corporation Commission 1200 W. Washington Street Phoenix, AZ 85007 Mr. Douglas Kent Porter Senior Counsel Southern California Edison Company Law Department, Generation Resources P.O. Box 800 Rosemead, CA 91770 Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 40 Buckeye, AZ 85326 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission Harris Tower & Pavillion 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-8064 Chairman Maricopa County Board of Supervisors 301 W. Jefferson, 10th Floor Phoenix, AZ 85003 Mr. Aubrey V. Godwin, Director Arizona Radiation Regulatory Agency 4814 South 40 Street Phoenix, AZ 85040 Mr. Craig K. Seaman, General Manager Regulatory Affairs and Performance Improvement Palo Verde Nuclear Generating Station Mail Station 7636 P.O. Box 52034 Phoenix, AZ 85072-2034 Mr. John Taylor Public Service Company of New Mexico 2401 Aztec NE, MS Z110 Albuquerque, NM 87107-4224 Mr. Geoffrey M. Cook Southern California Edison Company 5000 Pacific Coast Hwy Bldg N50 San Clemente, CA 92672 Mr. Robert Henry Salt River Project 6504 East Thomas Road Scottsdale, AZ 85251 Mr. Jeffrey T. Weikert Assistant General Counsel El Paso Electric Company Mail Location 167 123 W. Mills El Paso, TX 79901 Mr. John Schumann Los Angeles Department of Water & Power Southern California Public Power Authority P.O. Box 51111, Room 1255-C Los Angeles, CA 90051-0100 Mr. Brian Almon Public Utility Commission William B. Travis Building P.O. Box 13326 1701 North Congress Avenue Austin, TX 78701-3326 Ms. Karen O'Regan Environmental Program Manager City of Phoenix Office of Environmental Programs 200 West Washington Street Phoenix AZ 85003 Mr. Matthew Benac Assistant Vice President Nuclear & Generation Services El Paso Electric Company 340 East Palm Lane, Suite 310 Phoenix, AZ 85004