December 22, 2006 Kevin T. Walsh, Vice President of Operations Waterford 3 Entergy Operations, Inc.
17265 River Road Killona, LA 70057-3093
SUBJECT:
COMMITMENTS AND INFORMATION RELATED TO STEAM GENERATOR BATWING DEGRADATION AND CONTINUED PLANT OPERATION
Dear Mr. Walsh:
This refers to your letters to the NRC regarding actions to address and compensate for degraded steam generator components (batwings) during operation of the Waterford 3 nuclear plant this cycle. Your letter, W3F1-2006-0070, dated December 20, 2006, provides commitments that you and the NRC have deemed necessary in order to support continued safe operation. In particular, you have committed to more restrictive plant shutdown criteria and to participate in a meeting with NRC management in the Spring of 2007 to discuss operational steam generator performance and your planned midcycle outage. Further, we understand that, with regards to Commitment Number 15, your plans for steam generator inspections during the midcycle outage will include inspections necessary to validate your analytical assumptions.
Based on our review of your commitments, we have no objections to your plans to continue to operate the Waterford 3 nuclear plant under the conditions described in your letter. We will continue to evaluate your plans, along with any further information you provide at the aforementioned management meeting. If you have any questions regarding these matters, please contact Jeffrey A. Clark of my staff at (817) 860-8185.
In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter, and any responses you provide will be made available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records System (PARS) component of NRCs document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
Sincerely,
/RA/
Bruce S. Mallett Regional Administrator Docket: 50-382 License: NPF-38 Entergy Operations, Inc.
Executive Vice President and Chief Operating Officer Entergy Operations, Inc.
P.O. Box 31995 Jackson, MS 39286-1995 Vice President, Operations Support Entergy Operations, Inc.
P.O. Box 31995 Jackson, MS 39286-1995 General Manager, Plant Operations Waterford 3 SES Entergy Operations, Inc.
17265 River Road Killona, LA 70057-3093 Manager, Licensing Entergy Operations, Inc.
17265 River Road Killona, LA 70057-3093 Chairman Louisiana Public Service Commission P.O. Box 91154 Baton Rouge, LA 70825-1697 Director, Nuclear Safety Assurance Entergy Operations, Inc.
17265 River Road Killona, LA 70057-3093 Richard Penrod, Senior Environmental Scientist, State Liaison Officer Office of Environmental Services Northwestern State University Russsell Hall, Room 201 Natchitoches, LA 71497 Parish President Council St. Charles Parish P.O. Box 302 Hahnville, LA 70057 Entergy Operations, Inc.
Electronic distribution by RIV:
Regional Administrator (BSM1)
DRP Director (ATH)
DRS Director (DDC)
DRS Deputy Director (RJC1)
Senior Resident Inspector (GFL1)
Branch Chief, DRP/E (ZKD)
Senior Project Engineer, DRP/E (VGG)
Team Leader, DRP/TSS (MAS3)
RITS Coordinator (KEG)
D. Cullison, OEDO RIV Coordinator (DGC)
ROPreports WAT Site Secretary (AHY)
SUNSI Review Completed: __x___ ADAMS: #Yes G No Initials: _JAC__
- Publicly Available G Non-Publicly Available G Sensitive
- Non-Sensitive DRS/BC:EB1 DRP/BC/E NRR DRP/D DRS/D RA JAClark DLProulx JGrobe ATHowell DDChamberlain BSMallet
/RA/
/RA/
E:JClark
/RA/
/RA/
/RA/
12/21/06 12/21/06 12/21/06 12/21/06 12/21/06 12/22/06 OFFICIAL RECORD COPY T=Telephone E=E-mail F=Fax