Final Status Survey Final Report Phase IV Appendix A10 Survey Unit Release Record 9106-0010, Discharge Canal Novenmber 2006
CYAPCO FINAL STATUS SURVEY RELEASE RECORD DISCHARGE CANAL SURVEY UNIT 9106-0010 Prepared By: Date: i- a -01 FSSE neerr Reviewed BP: I Date: S' 0(,
F'S~.F~g 4 neer Approved By: q&!YAT 4 Date:_____O Technical Support Manager Revision 0
DISCHARGE CANAL SURVEY UNIT 9106-0010 RELEASE RECORD TABLE OF CONTENTS
- 1. SURVEY UNIT DESCRIPTION ................................................................ 3
- 2. CLASSIFICATION BASIS ....................................................................... 3
- 3. DATA QUALITY OBJECTIVES (DQO) ................................................... 5
- 4. SURVEY DESIG N ................................................................................... 8
- 5. SURVEY IMPLEMENTATION ................................................................ 11
- 6. SURVEY RESULTS ............................................................................... 12
- 7. QUALITY CONTROL ............................................................................. 14
- 8. INVESTIGATIONS AND RESULTS ....................................................... 15
- 9. REMEDIATION AND RESULTS ............................................................ 15
- 10. CHANGES FROM THE FINAL STATUS SURVEY PLAN ..................... 15
- 11. DATA QUALITY ASSESSMENT (DQA) ............................................... 15
- 12. A NO M A LIES .... ..................................................................................... 16
- 13. CO NC LUSIO N........................................................................................ 16
- 14. ATTACHM ENTS .................................................................................... 17 14.1 Attachment 1 - Figures (6 pages including cover) 14.2 Attachment 2 - Sample and Statistical Data (206 pages including covers)
Revision 0
DISCHARGE CANAL SURVEY UNIT 9106-0010 RELEASE RECORD SURVEY UNIT DESCRIPTION Survey Unit 9106-0010 (Discharge Canal) is designated as Final Status Survey (FSS) Class 2 and consists of approximately 9,512 mi (2.35 acres) of water covered sediment in an area located approximately 1.10 miles from the reference coordinate system benchmark used at the Haddam Neck Plant (HNP)
(see Attachment 1, Figure 1). The Discharge Canal is a man-made mile long waterway that runs parallel to, and ultimately communicates with the Connecticut River. The Discharge Canal is subdivided into fifteen (15) survey units including two (2) permanent wetland areas for FSS purposes. The survey unit is bounded as follows: Discharge Canal Survey Unit 9106-0009 is to the north (called north as orientated with the north to south flow of the Connecticut River), Survey Area 9523 is to the east, Discharge Canal Survey Unit 9106-0011 is to the south and Survey Area 9531 is to the west. The survey unit comprises the canal sediments to the depth of three feet from the top of the sediment layer or the original construction depth and it extends up the canal banks to the mean high water level.
This survey unit is bounded by reference coordinates EO 13 through E020 and by S156 through S168 (refer to License Termination Plan Section 5.4.4). The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS).
- 2. CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, "Survey Unit Classification." The historical information, scoping analyses and characterization results provided sufficient data to designate Survey Unit 9106-0010 as Class 2 in May 2006.
The "Classification Basis Summary" conducted for this survey unit consisted of:
a) A review of the 10CFR50.75 (g) (1) database, b) A review of the "Initial CharacterizationReport" and the "HistoricSite Assessment (HSA) Supplement, "
c) Historic and current survey records review, d) Visual inspections and a "walk-down."
e) Formal or informal interviews with cognizant personnel.
A review of the 10CFR50.75(g)(1) database report identified a number of events that might have impacted this survey unit. This was expected since the discharge canal served as the licensed discharge pathway for liquid releases.
Several events indicated the potential for plant related contamination in the survey unit. These included a number of primary side system to secondary side Revision 0 3 Revision 0 3
DISCHARGE CANAL SURVEY UNIT 9106-0010 RELEASE RECORD system leakage events, contamination found to be present in secondary side systems and components, and unmonitored spills that drained to the discharge canal. In 1986, samples were taken from the legacy dredge spoils removed in 1979 dredged spoils area and from recently dredged canal sediment. The sample analyses indicated that the concentrations of Cs-137, Co-60 and other radionuclides were a small fraction of the DCGLs for those nuclides that could be identified by gamma spectroscopy. (refer to NE-86-RA-1142 dated 11 86). None of the available historical information reviewed would support a conclusion that any residual activity in this survey unit is likely to be present at concentrations greater than the respective DCGLs.
Additional information was provided by several historical documents, including the "Results of Scoping Survey", (completed 9/1/98), the "Historical Site Assessment", and the HSA Supplement (dated 6-30-00). These documents presented the results of several sediment samples taken in 1997. These sample results indicated concentrations of 0.5 pCi/g for Co-60, 0.024 pCi/g for Cs-134 and 0.722 pCi/g for Cs-137.
An initial characterization survey was performed during April and May of 2004.
However, none of these samples were taken from within the footprint of survey Unit 9106-0010.
A final characterization was performed by Site Closure personnel in April of 2006 to obtain the necessary data of sufficient data quality for Final Status Survey (FSS) planning purposes. Six (6) 3-foot core sediment samples were taken from six (6) locations. All of the samples were analyzed by gamma spectroscopy. Since Hard-to-Detect (HTD) analyses were not performed, and since Ni-63 was found to be a nuclide of concern in an adjacent discharge canal Survey Unit (SU 9106-0009), for conservatism it was included as a nuclide of concern in Survey Unit 9106-0010. The Ni-63 concentration statistics were also included in the variance calculations to determine the size of the sample population for FSS. Although no additional HTD testing was performed for characterization; four (4) of the fifteen (15) samples taken to demonstrate compliance with the release criteria during FSS were tested for the full suite of HTD nuclides to provide additional assurance that all of the radionuclides of concern were appropriately addressed.. As a result of characterization, the radionuclides of concern identified for FSS planning purposes were Cs-137, Co-60 and Ni-63 (refer to Table 1).
Revision 0 4
DISCHARGE CANAL SURVEY UNIT 9106-0010 RELEASE RECORD
/. 1ZIZ,-Ul I /-.+/- M-u I Maximum Value: 4.32E-01 9.22E-01 2.59E+01 Mean: 1.97E-01 2.15E-01 2.5 1E+01 Median: 1.48E-01 7.76E-02 2.51E+O1 Standard Deviation: 1.86E-01 3.51 E-01 1.20E+00 NOTE: The Operational DCGLs are 6.01 pCi/g for Cs-137, 2.90 pCi/g for Co-60 and 549 pCi/g for Ni-63; these are used in conjunction with the unity rule to achieve nineteen (19) mrem/yr TEDE The FSS Engineer performed a visual inspection and walkdown during May 2006 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.
Based upon the historical information and the results of radiological surveys performed during characterization, it was concluded that there was a low probability for residual radioactivity to be present in this survey unit in concentrations greater than the Operational DCGLs justifying a survey unit classification of Class 2 (refer to Section 3).
- 3. DATA QUALITY OBJECTIVES (DQO)
FSS design and planning is based on the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, "Preparationof FinalStatus Survey Plan," and the "Multi-Agency Radiation Survey and Site Investigation Manual" (MARSSIM). A summary of the main features of the DQO process are provided herein.
The DQO process incorporates hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would satisfy the release criteria objective of the FSS.
The primary objective of the Final Status Survey Plan (FSSP) was to demonstrate that the level of residual radioactivity in Survey Unit 9106-0010 did not exceed the release criteria specified in the LTP and that the potential Revision 0 5 Revision 0 5
DISCHARGE CANAL SURVEY UNIT 9106-0010 RELEASE RECORD dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).
A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity. This is done through the development of Derived Concentration Guideline Levels (DCGLs). The DCGLs represent the concentration of radioactivity above background, equivalent to a dose-based release criterion and is presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL),
for existing groundwater radioactivity and for additional future groundwater radioactivity that will be contributed by building foundations and footings.
As described in detail in the LTP, the dose model applied to the discharge canal presumes that the canal sediments are dredged to a depth of three (3) feet below the top of the sediment layer and spread for the planting of crops per the Resident Farmer Scenario. Consequently, the soil DCGLs are directly applied to the canal sediment media The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity. Equation 1 shows the mathematical relationship between the three (3) components and the total dose.
Equation 1:
HTotal=Hsoil (sediment) + HExisting GW + HFuture GW The total dose under the LTP criteria is twenty-five (25) mrem/yr TEDE from all three components. The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for Connecticut Yankee (CY) is nineteen (19) mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the groundwater dose values discussed above.
This survey unit is not affected by either existing groundwater or by future groundwater (reference CY memo ISC 06-024). Therefore, dose contribution from both existing and future groundwater is zero (0) mrem/yr TEDE, based on field data.
Equation 2:
19 mrem/yrTotal= 19 mrem/yrsoi1+0 mrem/yrExisting GW+O mrem/yrFuture GW The allowable dose for soil in this survey unit is nineteen (19) mrem/yr TEDE as shown by Equation 2 above. The concentration of residual radioactivity Revision 0 6 Revision 0 6
DISCHARGE CANAL SURVEY. UNIT 9106-0010 RELEASE RECORD resulting in nineteen (19) mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2.
Note: The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 to conservatively account for the contribution to the total dose from existing and future groundwater which had not been established at the time of planning the FSS.
Iable 2 - Radionuclide Specific Base Case Soil DCGL, Operational DCGLs and Required*Minimum.DetectablelConcentrations Radioniuclide (1 Base Case Soil CGL
____ ,i/gY(2)
O perational DcGL Cpi/g) 0 rRequiired
.i/g (p l4 MDC H-3 4.12E+02 3.13E+02 1.65E+01 C-14 5.66E+00 4.30E+00 2.26E-01 Mn-54 1.74E+0I 1.32E+01 6.96E-01 Fe-55 2.74E+04 2.08E+04 1.1OE+03 Co-60 3.81 E+00 2.90E+00 1.52E-01 Ni-63 7.23E+02 5.49E+02 2.89E+0 I Sr-90 1.55E+00 1.18E+00 6.20E-02 Nb-94 7.12E+00 5.41E+00 2.85E-01 Tc-99 1.26E+01 9.58E+00 5.04E-01 Ag-108m 7.14E+00 5.43E+00 2.86E-01 Cs-134 4.67E+00 3.55E+00 1.87E-01 Cs-137 7.91E+00 6.01E+00 3.16E-0I Eu- 152 1.01 E+O1 7.68E+00 4.04E-01 Eu-154 9.29E+00 7.06E+00 3.72E-01 Eu-155 3.92E+02 2.98E+02 1.57E+01 Pu-238 2.96E+01 2.25E+01 1.18E+00 Pu-239/240 2.67E+01 2.03E+01 1.07E+00 Pu-241 8.70E+02 6.61E+02 3.48E+01 Am-241 () 2.58E+01 1.96E+O1 1.03E+00 Cm-243/244 2.90E+OI 2.20E+O1 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard to Detect (HTD)
(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to twenty-five (25) mrem/yr TEDE (3) The Operational DCGL is equivalent to nineteen (19) mrem/yr TEDE (4) The required MDC is equivalent to one (1) mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopy's when both analyses are performed.
Revision 0 7
DISCHARGE CANAL SURVEY UNIT 9106-0010 RELEASE RECORD Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability. Initial characterization was performed in April of 2004 as discussed in Section 2. Cs-137, Co-60 and Ni-63 were found to be the predominate radionuclides of concern. The basic statistical quantities (i.e., mean, standard deviation, median) for Cs-137, Co-60 and Ni-63 are provided in Table 1.
As part of the DQOs applied to laboratory processes, analysis results were reported as actual calculated results. Results reported as less than Minimum Detectable Concentration (<MDC) were not accepted for FSS. Sample report summaries included unique sample identification, analytical method, radionuclide, result, and uncertainty to two (2) standard deviations, laboratory data qualifiers, units, and the required and observed MDC.
- 4. SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. Guidance for preparing FSS plans is provided in Procedure RPM 5.1-11, "Preparation of Final Status Survey Plans ".
This survey was initially designed to ten (10) mrem/yr TEDE. At the time when the survey was designed, the dose contribution for existing and future groundwater had not yet been determined. Subsequently, a conservative value was chosen for the Operational DCGL. This approach is no longer required as the total dose from existing and future groundwater has been established. The dose for soil used for this survey unit to demonstrate compliance with the LTP criteria is nineteen (19) mrem/yr TEDE, as discussed in Section 2 of this Release Record.
The DQO process determined that Cs-137, Co-60 and Ni-63 were the radionuclides of concern (refer to Section 3). The sum of fractions or unity rule was used with the individual Operational DCGLs because multiple radionuclides (Cs-137, Co-60 and Ni-63) were considered in the survey design.
Surrogate DCGLs were not required for this survey unit based on process knowledge from FSS of nearby adjacent areas and via the screening process described in LTP Section 5.4.7.2, "Gross Activity DCGLs". Ni-63 concentrations in sediment and soil were ascertained by direct analysis.
Radionuclide screening or de-selection is a process where an individual radionuclide or aggregate may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations less than 5% for individual radionuclides and less than 10% for the aggregate of all radionuclides de-selected. This process was applied to analysis data for this survey unit.
The Elevated Measurement Comparison (EMC) did not apply to this survey unit since it is a Class 2 area and discrete, elevated areas of contamination were not expected.
Revision 0 8 Revision 0 8
DISCHARGE CANAL SURVEY UNIT 9106-0010 RELEASE RECORD The Sign Test was selected as the non-parametric statistical test to demonstrate that the null hypothesis was rejected. The use of the Sign Test did not require the selection or use of a background reference area, which simplified survey design and implementation. In addition, this approach is conservative since it includes background Cs-137 as part of the sample set.
The number of sediment samples for FSS was determined in accordance with Procedure RPM 5.1-12, "Determination of the Number of Samples for Final Status Survey. " The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 0.5 to maintain the relative shift (A/c) in the range of 1 and 3. The resulting relative shift was 2.1. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of MARSSIM in support of the decommissioning license termination rule (10CFR20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design.
This indicates that the survey unit has a high probability of rejecting the null hypothesis, assuming that the characterization data are representative of the FSS results. Survey design specified fifteen (15) sediment core samples for non-parametric statistical testing.
The grid pattern and locations of the sediment samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, "Identifying, and Marking Surface Sample Locationsfor Final Status Survey. "
Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a'Class 2 area.
Judgmental sampling was included as a feature of this survey design to address any anomalies identified in the field.
Sample locations were identified using AutoCAD-LT, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.
Revision 0 9 Revision 0 9
DISCHARGE CANAL SURVEY UNIT 9106-0010 RELEASE RECORD Taible 3 -Sam ple Nleasurement Locations with Associated GPS Coordinlates Designation No~rthing F>;EaS iI I ,
9106-0010-001F 233655.56 673189.16 9106-0010-002F 233655.56 673278.89 9106-0010-003F 233577.85 673144.30 9106-0010-004F 233577.85 673234.03 9106-0010-005F 233577.85 673323.76 9106-0010-006F 233500.14 673189.16 9106-0010-007F 233500.14 673278.89 9106-0010-008F 233422.43 673144.30 9106-0010-009F 233422.43 673234.03 9106-0010-01 OF 233422.43 673323.76 9106-0010-01IF 233344.72 673189.16 9106-0010-012F 233344.72 673278.89 9106-0010-013F 233344.72 673368.62 9106-0010-014F 233267.02 673323.76 9106-0010-015F 233267.02 673413.49 Four (4) sediment samples were analyzed for the full suite of radionuclides specified in Table 1, exceeding the requirement to analyze 5% of the sample population for HTD analysis specified in procedure RPM 5.1-11. Two (2) of the four (4) samples were randomly selected using the Microsoft Excel "RAND" function. The two (2) samples exhibiting the highest observed radionuclide concentrations by gamma analyses were also selected.
The implementation of quality control measures as referenced by Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey, " required the collection of two (2) soil samples for "split sample" analysis by the off-site laboratory. These locations were selected randomly using the Microsoft Excel "RAND" function. The number of quality control samples exceeded the 5%
requirement as specified by the LTP.
Section 5.7.3.2.6 of the LTP specifies that scanning is not required for the FSS of the Discharge Canal. Table 4 provides a synopsis of the survey design.
Revision 0 10 Revision 0 10
DISCHARGE CANAL SURVEY UNIT 9106-0010 RELEASE RECORD STable 4 - S nopsis of the Suiirve % Design
.. Feature.
.. Design Criteria , i. Basis' Survey Unit 9,512 m2 Based on AutoCAD-LT and Visual Land Area Sample Plan calculations Type I and Type 2 errors were 0.05, Number of 15 sigma was 0.238 the LBGR was set to 0.5 Measurements to maintain Relative Shift in the range of 1 and 3, Relative Shift was 2.1 Grid Spacing 23.4 m Based on triangular grid 3.16 pCi/g Cs-137 Design DCGL 1.52 pCi/g Co-60 To achieve ten (10) mrem/yr TEDE )
289 pCi/g Ni-63 Operational 6.01pCi/g Cs-137 To achieve nineteen (19) mrem/yr DC nl 2.90 pCi/g Co-60 TEDE (2) to demonstrate compliance with DCGL 549 pCi/g Ni-63 Equation 2 of this Release Record Scan Coverage N/A The LTP exempts this area Sediment 6.01 pCi/g Cs-1 37 The Operational DCGL meets the LTP Investigation 2.90 pCi/g Co-60 criteria for a Class 2 survey unit Level 549 pCi/g Ni-63 (1) The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 as the total dose from existing and future groundwater had not been established at the time of planning the FSS (2) The allowable dose for soil in this survey unit is nineteen (19) mrem/yr TEDE as the bounding dose from existing and future groundwater has been established based on field data (reference CY memo ISC 06-024)
- 5. SURVEY IMPLEMENTATION Final Status Survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2006-0021. The WP&IR package included a detailed FSSP, job safety analysis, job planning checklist and related procedures for reference. Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The "Daily Survey Journal" was used to document field activities and other information pertaining to the FSS.
Measurement locations were identified in North American Datum (NAD) 1927 coordinates that were supplied to the sampling vendor, Ocean Surveys, Inc.
(OSI) of Old Saybrook, Connecticut. Discharge Canal sampling was accomplished using direct push technology to collect composite samples of bottom and mean high water mark sediments. Sediment cores from the Discharge Canal were obtained by OSI using a vibrating corer that is platform mounted on a sampling vessel. The core barrel was a three (3) inch diameter thin-walled aluminum tube which also served as a core liner (ten (10) feet or less). A core catcher was available to prevent the sample from sliding out of the bottom of the tube. Vessel positioning and the determination of sample Revision 0 I1I
DISCHARGE CANAL SURVEY UNIT 9106-00 10 RELEASE RECORD locations were accomplished using a GPS interfaced with a navigation and data logging system.
After extraction, water was drained from above the sample by drilling holes above the sediment. The liner was cut, capped, sealed, labeled and turned over to site personnel who processed and controlled the samples under Chain of Custody (COC) protocols in accordance with procedure RPM 5.1-5, "Chain of Custody for Final Status Survey Samples. " Rinsing of the barrel and associated equipment was performed between sampling events. New aluminum tubes were used for each sample to prevent cross-contamination of subsequent samples.
The fifteen (15) sediment samples were collected and packaged in accordance with Haddam Neck Plant (H-NP) Procedure RPM 5.1-3, "Collection of Sample Media for Final Status Survey" and FSS design. Samples were controlled, transported, stored, and transferred to the off-site laboratory using COC protocols.
Four (4) samples (9106-0010-001F, 9106-0010-008F, 9106-0010-012F and 9106-0010-013F) were selected for HTD radionuclide analysis by the off-site laboratory.
The implementation of quality control measures included the collection of two (2) split samples at locations 9106-0010-011F and 9106-0010-014F for comparative analysis by the off-site laboratory.
- 6. SURVEY RESULTS The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories (GEL) - Charleston, South Carolina. The laboratory analyzed the fifteen (15) samples taken for non-parametric statistical testing and the associated duplicates using gamma spectroscopy. Ni-63 was analyzed by liquid scintillation analysis. All analyses were performed to the required MDC.
Cs-137 was positively identified (i.e., a result greater than two (2) standard deviations uncertainty) in thirteen (13), Co-60 was positively identified in eleven (11) and Ni-63 was positively identified in none of the fifteen (15) samples. The results reported for the remaining sample analyses indicated that activity was present at levels approaching or below the established detection limits in the remaining samples collected and analyzed for non-parametric testing.
Several other radionuclides which were positively identified (i.e., a result greater than two (2) standard deviations uncertainty) could be de-selected or excluded using the 5% and 10% rule described in Section 5.4.7.2 of the LTP.
Revision 0 12 Revision 0 12
DISCHARGE CANAL SURVEY UNIT 9106-0010 RELEASE RECORD The off-site laboratory also processed four (4) samples for full HTD analysis as required by the sample plan. The requested analyses included alpha spectroscopy, gas flow proportional counting, and liquid scintillation depending upon the radionuclide and the measurement method. All analyses were performed to the required MDC. Four (4) of the HTD radionuclides met the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty) in more than one sample; however, each of the positive results for HTD radionuclides could be de-selected based on the 5% and 10% rules.
None of the samples exceeded the Operational DCGL or required further investigation. A summary of the sample results is provided in Table 5.
Table 5- Sn imi-Nrof SoilSamnple Results>
Sumbler pCs-7 ~Co-60~ Ni-63 Fraction I' of the i Sam11brl p~s/-1, d~/0pgA OperatioflmI DCGLI 9106-0010-001 F 2.60E-01 5.75E-01 -1.07E+00 2.40E-01 9106-0010-002F 2.78E-02 5.45E-02 -4.66E+00 1.49E-02 9106-0010-003F 6.72E-02 -2.26E-03 -3.75E+00 3.57E-03 9106-0010-004F 4.92E-02 8.38E-02 -4.77E+00 2.84E-02 9106-0010-005F 1.08E-02 -2.17E-05 -3.87E+00 -5.26E-03 9106-0010-006F 1.47E-0 I 1.82E-01 -2.58E+00 8.25E-02 9106-0010-007F 8.OOE-02 8.30E-02 -2.34E+00 3.77E-02 9106-0010-008F 2.20E-01 1.95E-02 -2.65E+00 3.85E-02 9106-0010-009F 1.30E-01 1.92E-01 -3.71 E+00 8.11 E-02 9106-0010-01 OF 1.1 7E-01 5.08E-02 -3.80E+00 3.01 E-02 9106-0010-011F 3.45E-01 2.27E-01 6.33E+00 1.47E-01 9106-0010-012F 1.94E-01 4.03E-0I -2.72E+00 1.66E-01 9106-0010-013F 7.71 E-03 1.48E-03 -4.88E+00 -7.1 OE-03 9106-0010-014F 8.57E-02 5.07E-02 -4.24E+00 2.40E-02 9106-0010-015F 6.73E-03 2.28E-02 -1.48E+00 6.29E-03 (1) The Operational DCGLs from Table 2 are 6.01 pCi/g for Cs-137, 2.90 pCi/g for Co-60 and 549 pCi/g for Ni-63; these are used in conjunction with the unity rule to achieve nineteen (19) mrem/yr TEDE.
NOTE: The off-site laboratory reported that fourteen (14) of the fifteen (15) samples analyzed for Ni-63, within this survey unit, had a negative value reported. These negative values when used to determine the fraction of the Operational DCGL for the Radionuclide(s) of Concern had a maximum effect of lowering the fraction of the Operational DCGL present by less than 1% and the corresponding assigned dose for this survey unit by less than 0.2* mrem/yr TEDE.
- [-4.88 pCi/g (Maximum reported negative value for Ni-63) + 549 pCi/g (Operational DCGL for Ni-63) x 19 mrem/yr TEDE per DCGL = -0.169 mrem/yr TEDE z -0.2 mrem/yr TEDE]
Revision 0 13 Revision 0 13
DISCHARGE CANAL SURVEY UNIT 9106-0010 RELEASE RECORD One (1) biased sample was required by the FSS plan. This sample was designated as sample location 9106-0010-016F. Sample results for sample location 9106-0010-016F are presented in Table 6 below.
4 < Table 6 -Biased Sa nip)Ie Results Cs-137 Co-60 Ni-63 Fr-action of the Sample Number&-/( pcugf 1)(/g? Opertiona 9106-0010-016F 1.61E-02 1.49E-02 -5.24E+00 -1.73E-03 (1) The Operational DCGLs from Table 2 are 6.01 pCi/g for Cs-137, 2.90 pCi/g for Co-60 and 549 pCi/g for Ni-63; these are used in conjunction with the unity rule to achieve nineteen (19) mrem/yr TEDE
- 7. QUALITY CONTROL The two (2) split samples taken for QC were analyzed by the off-site laboratory.
The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 and as detailed in HNP Procedure RPM 5.1-24, "Split Sample Assessment for Final Status Survey. "
The first split-sample, 9106-0010-O0OF/S, did not meet the comparison criterion for Cs-137. A possible cause for this anomaly could be the presence of Cs-137 tightly bound to organic material in the sample aliquot. This distribution of material does not lend itself to homogenous mixing in a sediment matrix and, therefore, is not necessarily an indicator of inadequate sampling or sample preparation methodology. Additionally, Co-60 did meet the comparison criteria for the sample results. However, Ni-63 had a resolution of one (1) and values
<4 have not been addressed in NRC Inspection Procedure 84750. Therefore, a determination of the acceptability for values <4 can not be made. In this sample, K-40, a natural radioisotope, was found to be present at an acceptable level of agreement; therefore, the comparison was determined to be acceptable.
For the second QC split sample, 9106-0010-014F/S, did not meet the comparison criterion for Co-60. A possible cause for this anomaly could be the presence of Co-60 in the form of discrete particles. Such a physical form does not lend itself to homogenous mixing in a sediment matrix and, therefore, is not necessarily an indicator of inadequate sampling or sample preparation methodology. Additionally, Cs-137 did meet the comparison criteria for the sample results. However, Ni-63 had a resolution of negative two (-2) and values
<4 have not been addressed in NRC Inspection Procedure 84750. Therefore, a determination of the acceptability for values <4 can not be made. In this sample, K-40, a natural radioisotope, was found to be present at an acceptable level of agreement; therefore, the comparison was determined to be acceptable.
The sample analysis vendor, General Engineering Laboratories (GEL) -
Charleston, South Carolina, maintained quality control and quality assurance plans as part of normal operation. Refer to Attachment 2 for data and data quality analysis results.
Revision 0 14 Revision 0 14
DISCHARGE CANAL SURVEY UNIT 9106-0010 RELEASE RECORD
- 8. INVESTIGATIONS AND RESULTS No investigation was required to be performed since none of the sample results exceeded the investigation levels.
- 9. REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, "ALARA Evaluation of Soil Remediation in Support of Final Status Survey, " determined that remediation beyond that required to meet the release criteria to be unnecessary and that the remaining residual radioactivity in soil was ALARA.
- 10. CHANGES FROM THE FINAL STATUS SURVEY PLAN The survey was designed to ten (10) mrem/yr TEDE which was conservative and necessary at the time of FSS planning. It is no longer required as the total dose from existing and future groundwater has been established. The dose for soil used to demonstrate compliance with the LTP criteria is nineteen (19) mrem/yr TEDE as discussed in Section 2 of this Release Record.
- 11. DATA QUALITY ASSESSMENT (DQA)
The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, "Data Quality Assessment. " The sample design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs.
The evaluation of the Sign Test results indicates that the survey unit passes the unrestricted release criterion.
Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 2.
The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation). The standard deviation was slightly more than the value used for the survey design. This is represented by the shift in the retrospective power curve as shown in Attachment 2f. This would indicate a need to change the original LBGR in order to maintain the number of samples at fifteen (15) to meet the Operational DCGL. However, the value of LBGR is not a critical issue as the survey unit has passed the statistical test, and the mean and median values are well below the Operational DCGL when used in conjunction with the unity rule. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power.
Therefore, the survey unit meets the unrestricted release criterion with adequate power as required by the DQOs.
Revision 0 15 Revision 0 15
DISCHARGE CANAL SURVEY UNIT 9106-0010 RELEASE RECORD The range of the data, about 3.41 standard deviations, was not unusually large.
The difference between the mean and median was 40.3% of the standard deviation which indicates some skewness in the data. The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot shows some positive skewness as confirmed by the calculated skew of 1.07.
All data, assessments, and graphical representations are provided in Attachment 2.
- 12. ANOMALIES The anomalies associated with the disagreement between the field splits has been discussed in Section 7. The source of the disagreement for Co-60 and Cs-137, were likely due to Co-60 being present in the form of discrete particles and Cs-137 being tightly bound to organic materials in the sample media. Such a physical form does not lend itself to homogenous mixing in a sediment matrix.
- 13. CONCLUSION Survey Unit 9106-0010 has demonstrated compliance with the dose based, unrestricted release criterion. The sample data passed the Sign Test and the null hypothesis was rejected. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. Reclassification and remediation of this survey unit was not required.
Graphical representation of data indicates some positive skewness that is probably due to localized differences in particulate deposition rates, hydraulic velocity and sedimentation rates. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved. The survey unit was properly designated as a Class 2 survey unit.
As stated in Section 6, fourteen (14) of the fifteen (15) sample results reported for Ni-63 were negative values. These negative values were used when determining the sum of the fractions (unity rule) and, therefore, lowered the reported fraction of the Operational DCGL. In the interests of conservatism, the maximum dose contribution from the negative impact of using these values will be added to the total dose for this survey unit. The maximum dose contribution for Ni-63 is less than 0.2 mrem/yr TEDE.
The dose contribution from sediment in this survey unit is 1.3 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.
This survey unit is not affected by existing groundwater (reference CY memo ISC 06-024). It has been determined that the dose contribution from groundwater sources is zero (0) mrem/yr TEDE.
This survey unit also is not considered impacted by future groundwater radioactive contamination, as there are no concrete foundations or footings Revision 0 16
DISCHARGE CANAL SURVEY UNIT 9106-0010 RELEASE RECORD containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component is, therefore, zero (0) mrem/yr TEDE.
The average total dose from residual radioactivity in this survey unit, including that from sediment, will not exceed 1.3 mrem/yr Total Effective Dose Equivalent (TEDE).
- 14. ATTACHMENTS 14.1 Attachment 1 - Figures 14.2 Attachment 2 - Sample and Statistical Data Revision 0 17
DISCHARGE CANAL SURVEY UNIT 9106-0010 RELEASE RECORD Attachment 1 Figures (5 pages)
1.*
K Not=
0 420 840 Fwo
=
Coma~rdwm nz NADtZ7Cbnft
/
I Connecticut Yankee Atomic PowerCompany Site M4p With Reference To Survey Unit9106-0010
S sample Locs6im 0
4 7
3 0 6 0 10 0w 9106-0010 0
13 9 0 JO
-WýSW 00" 12 e
0 8
11 0 14 Coamwcut Yankee Atomic Power Company 9106-001OFma Sta'tu Siuwvy Degn
K 0.0278 9
0.260 Sample LoCation 0
0.0492 0.080 0.0672 0 0.147 0 0.117 0
9106-0010 0
0 30 60 I Fo' 0.130 Ab.fmi 0.194 1bar2kowme 0 0.1 S4WePbMnaSC 9 Camb-137n*mb 0.220 MvaimpMgi.
0.345 9 0.0857 Connecticut Yankee Atomic PowerCompany 9106-0010Fina Stitus Survey Cesium-137PostingPlot
0.0545
-0.i 0
0.575 Sample Location 0
0.0838 0.083
-0.0023 0 0.182 0 0.0508 0
9106-0010 0 0 30 60 I Fed 0.192 NOW 0.403 cowd&Wwavinw MUM2COWa~w
&W-hl--W 0
0.0195 5ieulmpavs 0.227 0 0.0507 Connecticut Yankee Atomic Power Company 9106-0010 FinalSttus Suwvcy Cobalt-60PostingPlot
4..
-4.66 0
-1.07 Staple Location 0
-4.77
-2.34
-3.75 0
-2.58
-3.80 0
9106-0010 0 30 NEEI 60 Fe
--3.71 N-Euh
-2.72 8ko&Mfr I 0
0
-2.65 AWa3mpO4m 6.33 o
-4.24 Connecticut Yankee Atomic Power Company 9106-0010 FinalStatus Survey Nickel-63 PostingPlot
DISCHARGE CANAL SURVEY UNIT 9106-0010 RELEASE RECORD Attachment 2 Sample and Statistical Data
DISCHARGE CANAL SURVEY UNIT 9106-0010 RELEASE RECORD Attachment 2a Sample Data (186 Pages)
Table ofContents G eneral Narrative .................................................................. 1 Chain of Custody and Supporting Documentation ........... 4 Radiological Analysis .......................................................... 11 Sample Data Summary ...................................................... 33 Q uality C ontrol D ata ........................................................... 73
General Narrative 1
CASE NARRATIVE For CONNECTICUT YANKEE RE: Sediment PO# 002332 Work Order: 163105 SDG: MSR #06-0707 June 16, 2006 Laboratory Identification:
General Engineering Laboratories, LLC Mailing Address:
P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address:
2040 Savage Road Charleston, South Carolina 29407 Telephone Number:
(843) 556-8171 Summary:
Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL) in Charleston, South Carolina on May 17, 2006. All sample containers arrived without any visible signs of tampering or breakage. The chain of custody contained the proper documentation and signatures.
The laboratory received the following sample(s):
Sample ID Client Sample ID 163105001 9106-0010-014F 163105002 9106-0010-014FS 163105003 9106-0010-O11F 163105004 9106-0010-011 FS 163105005 9106-0010-015F 163105006 9106-0010-005F 163105007 9 106-0010-003F 163105008 9106-0010-016F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP, INC.
P.O. Box 30712
- Charleston, SC 29417 ° 2040 Savage Road (29407)
Phone (843) 556-8171 - Fax (843) 766-1178 ° www.gel.com 2
Sample ID Client Sample ID 163105009 9106-0010-OOIF 163105010 9106-0010-002F 163105011 9106-0010-004F 163105012 9106-0010-006F 163105013 9106-0010-007F 163105014 9106-0010-009F 163105015 9106-0010-01OF 163105016 9106-0010-012F 163105017 9106-0010-008F 163105018 9106-0010-013F Items of Note:
There are no items of note.
Case Narrative:
Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.
Analytical Request:
Sixteen sediment samples were analyzed for FSSGAM and Ni-63.
Two sediment samples were analyzed for FSSALL.
Internal Chain of Custody:
Custody was maintained for the sample(s).
Data Package:
The enclosed data package contains the following sections: Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.
I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.
Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP,INC.
P.O. Box 30712
- Charleston, SC 29417
- 2040 Savage Road (29407)
Phone (843) 556-8171
- Fax (843) 766-1178 - www.gel.com 3
Chain of Custody and Supporting Documentation 4
Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Health Physics Procedure GPP-GGGR-R5 104-003-Attachment B-CY-00 I Major Connecticut Yankee Atomic Power Company Chain of Custody Form No.
362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:
Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 ,
843 556 8171. Attn. Cheryl Jones rA Priority: Z 30 D. E] 14 D. Ej 7 D. Container Media Type &Type Sample Desigation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0010-001F 5/04/06 10:49 SE C BP x x Transferred from COC 2006-00321 9106-0010-002F 5/04/06 11:12 SE C BP X X, Transferred from COC 2006-00321 9106-0010-004F 5/04/06 12:48 SE C BP X X Transferred from COC 2006-00321 9106-0010-006F 5/04/06 13:34 SE C BP x x Transferred from COC 2006-00321 9106-0010-007F 5/04/06 13:21 SE C BP x x Transferred from COC 2006-00321 T 9106-0010-009F 5/04/06 14:01 SE C BP x x Transferred from COC 2006-00321 9106-0010-01OF 5/04/06 14:21 SE C BP x X Transferred from COC 2006-00321 01P' 9106-0010-012F 5/04/06 14:44 SE C BP x x oil Transferred from COC 2006-00321 9106-0010-013F 5/04/06 15:06 SE C BP x Transferred from COC 2006-00321
- 4. .4 4 I-~-+----4----4 I
___________________________________ L _____________ £ _____________ .1_________ J L L......~......J. J L .J.J......J...............
Internal Container
.1 NOTES: PO #: 002332 MSR #: 06- 07-07 SSWP# NA [ LTP QA [] Radwaste QA El Non QA Samples Shipped Via: Internal Container Z Fed Ex Temp.: /7Deg. C El uPS El Hand Cus tod9yealed?
Y*" NEI
- 1) RelinquisheBy Date/Ti e 2) Received y Date/Time Custody Seal Intact?
El Other
- 3) Relinquished By Date/Time 4) Received By r Date/Time D Y 9"N 11 Bill of Lading #
3qo4- 3 1,- 6` -
I
Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00350 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:
Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones ci z Priority: Z 30 D. [] 14 D. El 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0010-014F 5/05/06 10:23 SE C BP X x Transferred from COC 2006-00324 9106-0010-014FS 5/05/06 10:23 SE C BP X X Transferred from COC 2006-00324 p' 9106-0010-01IF 5/05/06 09:39 SE C BP X x Transferred from COC 2006-00324 9106-0010-011FS 5/05/06 09:39 SE C BP x x Transferred from COC 2006-00324 9106-0010-015F 5/05/06 10:02 SE C BP x X Transferred from COC 2006-00324 9106-0010-005F 5/05/06 08:25 SE C BP X X Transferred from COC 2006-00324 9106-0010-008F 5/05/06 09:21 SE C BP x Transferred from COC 2006-00324 9106-0010-003F 5/05/06 07:48 SE C BP X X Transferred from COC 2006-00324 9106-0010-016F 5/15/06 10:45 SE C BP X x Transferred from COC 2006-00351 NOTES: PO #: 002332 MSR #: 06-ov'rO' SSWP#NA 0 LTP QA E] Radwaste QA E] Non QA Samples Shipped Via: Internal Co.gtamer 0 Fed Ex Temp.: I Deg. C FI uPs El Hand Custody Sealed?
- 1) Relinquished By Date/Tni e 2)Rzeiye Jm,.c _**,/-o //-D~ *,_* 1 Date/Time 5-11!-6t(0 y" El Other Custody Seal Intact?
- 3) Relinquished By Date/Time 4) Received By ) Date/Time Y &ý- N 0 Bill of Lading #
Connecticut Yankee Statement of Work for Analytical Lab Services -CY-IsC-SOW-o00 Figure 1. Sample Check-in List.
q V.' 05 -//-Id L Date/Time Received:
SDG#:
Work Order Number: /6.0 'Z Shipping Cdntainer ID:-St9) 3113 BSs Chain of Custody
- 1. Custody Seals orf shipping container intact?... :Yes No [I
- 2. Custody Seals dated and signed? Yes'*$No [].
- 3. Chain-of-Custody record present? Yes NX No []
.4. Cooler .temperature /7 a
- 5. Vermiculite/packing materials is: Wet^, Dry [']
- 6. Number of samples in shipping container:
- 7. Sample holding times exceeded? Yes [ ] No M
- 10. Were any anomalies identified in sample receipt?
I1.- Description of anomalies (include sample numbers):
Sample Custodian/Laboratory: . Date__. _ _-______-____
Telephoned to: On "-By 7
FORM RECEIPT & REVIEW eE ON? R110' % PM use only Client: il,'fdt ISDG/ARCOC/Work Order:
Date Received: 5- [7 -0,6 PM(A) Review( a" oo g items are resolved prior to signing):
Received By- " -7 .
Sample Receipt Criteria W Comm 1ents/Qualifiers (Required for Non-Conforming Items)
Shipping containers received intact Circle Applicable: seals broken damaged container leaking container other (describe) and sealed?
Samples requiring cold Circle Coolant # ice bags blue ice dry ice 4iýJ) other describe) 2 preservation within (4 +/- 2 C)?
Record preservation method.
Chain of custody documents included with shipment?
Sample containers intact and Circle Applicable: seals broken damaged container leaking container other (describe) sealed?
Samples requiring chemical Sample ID's. containers affected and observed pH:
preservation at proper pH?
Sample ID's and containers affected:
6 VOA vials free of headspace (defined as < 6mm bubble)?
Are Encore containers present?
7 (If yes, immediately deliver to VOA laboratory)
Id's and tests affected:
8 Samples received within holding time? _
9Sample ID's on COC match ID's Sample ID's and containers affected:
on bottles?
Date & time on COC match date Sample ID's affected:
& time on bottles? _
Sample ID's affected:
Number of containers received match number indicated on COC?
COC form is properly signed in 12 relinquished/received sections?
Air Bill ,Tracking #'s, &
1Additional Comments 4 ) RSO RAD Receipt##
8 *If > x2 area background is observed on samples identified as 'non-Suspected Hazard Information = regulated/non-radioactive", contact the Radiation Safety group for further
- investigation.
A [Radiological Classification? fri Maximum Counts Observed*: (2 rIPCB P RegulatedR? _ Comments:
rShipped as DOT Hazardous C Material? If yes, contact Waste Hazard Class Shipped:
Manager or ESH Manager. :
PM (or PMA) review of Hazard classification: Initials D f /
8
Connecticut Yankee Statement of Work for Analytical Lab Services .CY-ISC-SOW-001 Figure 1. Sample Check-in List Date/Time Received: q 4,/( 7 0/o6 SDG#: 1~ rJ-07c 6 to 7 Work Order Number:
Shipping CdhtainerID: -?*7O 311? 85YI Chain of Custody*# "o - 603j:
I. Custody Seals.ori shipping container intact?. Yes 1* No [ ]
- 2. Custody Seals dated and signed? Yes*[ No [ J
- 3. Chain-of-Custody record present? Yes [)Q No [ ]
- 4. Cooler temperature 7e
- 5. Vermiculite/packing materials is: Wet pq Dry []
6.: Number of samples in shipping container: ,
- 7. Sample holding times exceeded? Yes No
.8. Samples have:
tape -hazard labels
__.eustody seals -appropriate sample labels
- 9. Samples arei 4_ý_ingood condition l~eaking broken .have air bubbles
- 10. Were any anomalies identified in sample receipt? Yes[ ] No [(]
- 11. Description of anomalies (include sample numbers):
Sample Custodian/Laboratory: --11A * ") Date: . j-:-O Telephoned to: O By 9
SSAMPLE RECEIPT & REVIEW FORM
'4?OrR 'l' wMuae only Client: G)A'A. ISDG/ARCOCfWork Order:
Date Received: 1" . PM(A) Review (ensure non e resolved prior to signing):
Received By:
Sample Receipt Criteria ~Corn * /Qualifiers (Required for Non-Conforming Items) other (describe)
ICircle Applicable: seals broken damaged container leaking container 1 Shipping containers received intact and sealed?
Samples requiring cold Circle Coolant # ice bags blue ice dry ice A other describe) 2 preservation within (4 +/- 2 C)? /7Of.
Record preservation method.
Chain of custody documents included with shipment?
4 Sample containers intact and Circle Applicable: seals broken damaged container leaking container other (describe) sealed?
Samples requiring chemical Sample ID's. containers affected and observed pH:
5preservation at proper pH?
Sample ID's and containers affected:
6 VOA vials free of headspace (defined as < 6mm bubble)?
Are Encore containers present?
7 (If yes, immediately deliver to VOA laboratory)
Samples received within holding Id's and tests affected:
time?
9 Sample ID's on COC match ID's Sample ID's and containers affected:
on bottles?
Date & time on COC match date Sample ID's affected:
& time on bottles?
Number of containers received Sample ID's affected:
match number indicated on COC?
COC form is properly signed in relinquished/received sections? ]
Air Bill ,Tracking l #'s,A&" 90 ?(/
- 5'*
14Additional Comments SRSO RAD Receipt #_ __ _ _
qr - -5. *If > x2 area background is observed on samples identified as "non-t Ha f regulated/non-radioactive". contact the Radiation Safety group for further 94 investigation.
B PCB Regulated? Comments:
Shipped as DOT Hazardous C Material? If yes, contact Waste V/ Hazard Class Shipped:
IManager or ESH Manager. UN#:
PM (or PMA) review of Hazard classification: Initials 4b Date: a//7 , "
¢ 10
RADIOLOGICAL ANALYSIS 11
Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)
Work Order 163105 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 535134 Prep Batch Number: 531287 Dry Soil Prep GL-RAD-A-021 Batch Number: 531278 Sample ID Client ID 163105017 9106-0010-008F 163105018 9106-0010-013F 1201105084 Method Blank (MB) 1201105085 163105017(9106-0010-008F) Sample Duplicate (DUP) 1201105086 163105017(9106-0010-008F) Matrix Spike (MS) 1201105087 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
12
Quality Control (Q0 Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 163105017 (9106-0010-008F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information 13
Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- 11-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 535138 Prep Batch Number: 531287 Dry Soil Prep GL-RAD-A-021 Batch Number: 531278 Sample ID Client ID 163105017 9106-0010-008F 163105018 9106-0010-013F 1201105088 Method Blank (MB) 1201105089 163105017(9106-0010-008F) Sample Duplicate (DUP) 1201105090 163105017(9106-0010-008F) Matrix Spike (MS) 1201105091 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QCQ Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 163105017 (9106-0010-008F).
QC Information All of the QC samples met the required acceptance limits.
14
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Samples 1201105088 (MB), 1201105089 (9106-0010-008F) and 163105018 (9106-0010-013F) were recounted due to detector error.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu-i l-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 535141 Prep Batch Number: 531287 Dry Soil Prep GL-RAD-A-021 Batch Number: 531278 15
Sample ID Client ID 163105017 9106-0010-008F 163105018 9106-0010-013F 1201105092 Method Blank (MB) 1201105093 163105017(9106-0010-008F) Sample Duplicate (DUP) 1201105094 163105017(9106-0010-008F) Matrix Spike (MS) 1201105095 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QCQ Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 163105017 (9106-0010-008F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from 16
referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS Analytical Method: EML HASL 300, 4.5.2.3 Prep Method: Dry Soil Prep Analytical Batch Number: 531444 Prep Batch Number: 531278 Sample ID Client ID 163105001 9106-0010-014F 163105002 9106-0010-014FS 163105003 9106-0010-01 IF 163105004 9106-0010-011 FS 163105005 9106-0010-015F 163105006 9106-0010-005F 163105007 9106-0010-003F 163105008 9106-0010-016F 163105009 9106-0010-OO1F 163105010 9106-0010-002F 163105011 9106-0010-004F 163105012 9106-0010-006F 163105013 9106-0010-007F 163105014 9106-0010-009F 163105015 9106-0010-O0OF 163105016 9106-0010-012F 163105017 9106-0010-008F 163105018 9106-0010-013F 1201096203 Method Blank (MB) 120.1096204 163105001(9106-0010-014F) Sample Duplicate (DUP) 1201096205 Laboratory Control Sample (LCS) 17
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 11.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 163105001 (9106-0010-014F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
18
Qualifier information Qualifier Reason Analyte Sample U' Data rejected due to high full width half maximum. Cobalt-60 163105002 UI Data rejected due to high uncertainty. Bismuth-214 1201096204 UI Data rejected due to interference. Cesium- 134 163105011 Europium-155 163105001 163105005 163105006 1201096204 U' Data rejected due to low abundance. Cesium-134 163105001 163105002 163105003 163105005 163105006 163105014 163105017 Method/Analysis Information Product: GFPC, Sr9O, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 536335 Prep Batch Number: 531287 Dry Soil Prep GL-RAD-A-021 Batch Number: 531278 19
Sample ID Client ID 163105017 9106-0010-008F 163105018 9106-0010-013F 1201107674 Method Blank (MB) 1201107675 163105017(9106-0010-008F) Sample Duplicate (DUP) 1201107676 163105017(9106-0010-008F) Matrix Spike (MS) 1201107677 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 163105017 (9106-0010-008F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.
20
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 531704 Sample ID Client ID 163105017 9106-0010-008F 163105018 9106-0010-013F 1201096867 Method Blank (MB) 1201096868 162583001 (NOL-02-02-005-F-S) Sample Duplicate (DUP) 1201096869 162583001 (NOL-02-02-005-F-S) Matrix Spike (MS) 1201096870 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
21
Ouality Control (0C) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 162583001 (NOL-02-02-005-F-S).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Sample 163105017 (9106-0010-008F) was recounted due to high MDA.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 531618 Prep Batch Number: 531287 Dry Soil Prep GL-RAD-A-021 Batch Number: 531278 22
Sample ID Client ID 163105017 9106-0010-008F 163105018 9106-0010-013F 1201096631 Method Blank (MB) 1201096632 163173001(9304-0000-063RACR) Sample Duplicate (DUP) 1201096633 163173001(9304-0000-063RACR) Matrix Spike (MS) 1201096634 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 163173001 (9304-0000-063RACR).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
23
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni- 1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 531622 Prep Batch Number: 531287 Dry Soil Prep GL-RAD-A-021 Batch Number: 531278 Sample ID Client ID 163105001 9106-0010-014F 163105002 9106-0010-014FS 163105004 9106-0010-011 FS 163105005 9106-0010-015F 163105006 9106-0010-005F 163105007 9106-0010-003F 163105008 9106-0010-016F 163105009 9106-0010-001F 1201096644 Method Blank (MB) 1201096645 163173001(9304-0000-063RACR) Sample Duplicate (DUP) 1201096646 163173001 (9304-0000-063RACR) Matrix Spike (MS),
1201096647 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.
24
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QCQ Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 163173001 (9304-0000-063RACR).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information 25
Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 531654 Prep Batch Number: 531287 Dry Soil Prep GL-RAD-A-021 Batch Number: 531278 Sample ID Client ID 163105010 9106-0010-002F 163105011 9106-0010-004F 163105012 9106-0010-006F 163105013 9106-0010-007F 163105014 9106-0010-009F 163105015 9106-0010-O0OF 163105016 9106-0010-012F 163105017 9106-0010-008F 163105018 9106-0010-013F 1201096727 Method Blank (MB) 1201096728 163105010(9106-0010-002F) Sample Duplicate (DUP) 1201096729 163105010(9106-0010-002F) Matrix Spike (MS) 1201096730 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Guality Control (0C) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
26
Designated QC The following sample was used for QC: 163105010 (9106-0010-002F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Sample 163105017 (9106-0010-008F) was recounted due to a negative result greater than three times the error.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 534699 Prep Batch Number: 531287 Dry Soil Prep GL-RAD-A-021 Batch Number: 531278 27
Sample ID Client ID 163105003 9106-0010-011F 1201104073 Method Blank (MB) 1201104074 163105003(9106-0010-01 IF) Sample Duplicate (DUP) 1201104075 163105003(9106-0010-01 IF) Matrix Spike (MS) 1201104076 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 163105003 (9106-0010-01 IF).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Sample 163105003 (9106-0010-01 IF) was reprepped due to spectral interference.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this 28
SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: LSC, Tritium Dist, Solid-HTD2,ALL FSS Analytical Method: EPA 906.0 Modified Analytical Batch Number: 531705 Sample ID Client ID 163105017 9106-0010-008F 163105018 9106-0010-013F 1201096877 Method Blank (MB) 1201096878 162583001 (NOL-02-02-005-F-S) Sample Duplicate (DUP) 1201096879 162583001(NOL-02-02-005-F-S) Matrix Spike (MS) 1201096880 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 11.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC 29
The following sample was used for QC: 162583001 (NOL-02-02-005-F-S).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Sample 1201096877 (MB) was recounted due to high MDA.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: Liquid Scint C14, Solid AII,FSS Analytical Method: EPA EERF C-01 Modified Analytical Batch Number: 534984 Sample ID Client ID 163105017 9106-0010-008F 163105018 9106-0010-013F 1201104745 Method Blank (MB) 1201104746 163173001 (9304-0000-063RACR) Sample Duplicate (DUP) 1201104747 163173001 (9304-0000-063RACR) Matrix Spike (MS) 1201104748 Laboratory Control Sample (LCS) 30
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 163173001 (9304-0000-063RACR).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Samples were reprepped due to low/high recovery.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
31
Qualifier information Manual qualifiers were not required.
Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.
Review Validation:
GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.
The following data validator verified the information presented in this case narrative:
Reviewer/Date:
32
SAMPLE DATA
SUMMARY
33
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.
Client SDG: MSR#06-0707 GEL Work Order: 163105 The Qualifiers in this report are defined as follows:
- A quality control analyte recovery is outside of specified acceptance criteria
UI Gamma Spectroscopy--Uncertain identification ND The analyte concentration is not detected above the reporting limit.
The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.
Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.
This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.
Reviewed by 34
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analvs.iq Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-014F Proiect: YANKO 1204 Sample ID: 163105001 Client ID: YANK001 Matrix: SE Vol. Recv.:
Collect Date: 05-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 20.4%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinitim-228 0.657 +/-0.147 0.0487 +/-0.147 0.104 pCi/g MJHI 05/31/06 1745 531444 1 Americium-241 U 0.0197 +/-0.135 0.0925 +/-0.135 0.191 pCi/g Bismuth-212 0.270 +/-0.294 0.113 +/-0.294 0.237 pCi/g Bismuth-214 0.430 +/-0.0735 0.0247 +/-0.0735 0.0522 pCi/g Cesium-134 UUI 0.00 +/-0.0318 0.0185 +/-0.0318 0.0389 pCi/g Cesiumn-137 0.0857 +/-0.0355 0.0143 +/-0.0355 0.0301 pCi/g Cobalt-60 0.0507 +/-0.0266 0.0131 +/-0.0266 0.0287 pCi/g Europium-152 U - 0.00125 +/-0.0441 0.0368 +/-0.0441 0.0768 pCi/g Europium-154 U 0.0628 +/-0.0565 0.0518 +/-0.0565 0.110 pCi/g Europium-155 UUI 0.00 +/-0.0699 0.0406 +/-0.0699 0.0838 pCi/g Lead-212 0.710 +/-0.0836 0.0237 +/-0.0836 0.049 pCi/g Lead-214 0.491 +/-0.0798 0.0276 +/-0.0798 0.0574 pCi/g Manganese-54 U 0.00641 +/-0.0164 0.0141 +/-0.0164 0.0298 pCi/g Niobium-94 U 0.0108 +/-0.0148 0.0132 +/-0.0148 0.0277 pCi/g Potassium-40 11.9 +1-1.05 0.0979 +/-1.05 0.221 pCi/g Radium-226 0.430 +/-0.0735 0.0247 +/-0.0735 0.0522 pCi/g Silver-108m U - 0.00638 +/-0.0136 0.0117 +/-0.0136 0.0246 pCi/g Thallium-208 0.215 +/-0.0408 0.0122 +/-0.0408 0.0258 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -4.24 +/-3.72 3.20 +/-3.72 6.53 pCi/g SLN1 05/27/06 0423 531622 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B AXP2 05/19/06 1856 531287 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 PD 05/19/06 0918 531278 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 DOE RESL Ni-1, Modified 35
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-01,F Project: YANKO 1204 Sample ID: 163105001 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 91 (25%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
36
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-014FS Project: YANKO 1204 Sample ID: 163105002 Client ID: YANK001 Matrix: SE Vol. Recv.:
Collect Date: 05-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 21.4%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.693 +/-0.139 0.0435 +/-0.139 0.092 pCi/g MJH1 05/31/06 2041 531444 1 Americium-241 U 0.0263 +/-0.0556 0.0504 +/-0.0556 0.104 pCi/g Bismuth-212 0.533 +/-0.235 0.0965 +/-0.235 0.203 pCi/g Bismuth-214 0.409 +/-0.0762 0.0267 +/-0.0762 0.0556 pCi/g Cesium-134 UUI 0.00 +/-0.0274 0.0163 +/-0.0274 0.0341 pCi/g Cesium-137 0.0659 +/-0.039 0.0131 +/-0.039 0.0275 pCi/g Cobalt-60 UUI 0.00 +/-0.034 0.0109 +/-0.034 0.0238 pCi/g Europium-152 U - -0.00333 +/-0.0383 0.0331 +/-0.0383 0.0688 pCi/g Europium-154 U -0.0107 +/-0.0435 0.0351 +/-0.0435 0.0753 pCi/g Europium-155 U 0.0641 +/-0.0609 0.0383 +/-0.0609 0.0788 pCi/g Lead-212 0.685 +/-0.0716 0.0196 +/-0.0716 ,0.0405 pCi/g Lead-214 0.554 +/-0.0813 0.0219 +/-0.0813 0.0458 pCi/g Manganese-54 U 0.00475 +/-0.0143 0.0125 +/-0.0143 0.0264 pCi/g Niobium-94 U 0.00908 +/-0.0136 0.0122 +/-0.0136 0.0255 pCi/g Potassium-40 12.9 +/-1.01 0.115 +/-1.01 0.249 pCi/g Radium-226 0.409 +/-0.0762 0.0267 +/-0.0762 0.0556 pCi/g Silver-108m U - 0.00399 +/-0.0129 0.0108 +/-0.0129 0.0227 pCi/g Thallium-208 0.201 +/-0.0387 0.012 +/-0.0387 0.0253 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -2.83 +/-4.47 3.80 +/-4.47 7.74 pCi/g SLNI 05/27/06 0524 531622 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B AXP2 05/19/06 1856 531287 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 PD 05/19/06 0918 531278 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-1, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 37
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-014FS Proiect: YANK01204 Sample ID: 163105002 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 92 (25%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
38
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-0111F Project: YANKO 1204 Sample ID: 163105003 Client ID: YANK001 Matrix: SE Vol. Recv.:
Collect Date: 05-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 23%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 1.02 +/-0.260 0.0931 +/-0.260 0.197 pCi/g MJHI 05/31/06 2154 531444 1 Americium-241 U 0.00183 +/-0.0449 0.0393 +/-0.0449 0.0804 pCi/g Bismuth-212 0.818 +/-0.423 0.206 +/-0.423 0.433 pCi/g Bismuth-214 0.616 +/-0.119 0.0485 +/-0.119 0.102 pCi/g Cesium-134 UUI 0.00 +/-0.0454 0.0343 +/-0.0454 0.0718 pCi/g Cesium-137 0.345 +/-0.0708 0.0306 +/-0.0708 0.0639 pCi/g Cobalt-60 0.227 +/-0.0748 0.0273 +/-0.0748 0.0589 pCi/g Europium-152 U 0.0136 +/-0.0815 0.0697 +/-0.0815 0.145 pCi/g Europium-154 U -0.0794 +/-0.0976 0.0769 +/-0.0976 0.165 pCi/g Europium-155 U 0.116 +/-0.106 0.0585 +/-0.106 0.120 pCi/g Lead-212 0.948 +/-0.0805 0.0382 +/-0.0805 0.0788 pCi/g Lead-214 0.802 +/-0.127 0.0475 +/-0.127 0.0988 pCi/g Manganese-54 U 0.0392 +/-0.0412 0.0323 +/-0.0412 0.0676 pCi/g Niobium-94 U 0.00593 +/-0.0311 0.0267 +/-0.0311 0.0558 pCi/g Potassium-40 14.5 +/-1.09 0.265 +/-1.09 0.571 pCi/g Radium-226 0.616 +/-0.119 0.0485 +/-0.119 0.102 pCi/g Silver-108m U -0.0184 +/-0.0298 0.0241 +/-0.0298 0.0501 pCi/g Thallium-208 0.273 +/-0.0627 0.028 +/-0.0627 0.0585 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 6.33 +/-9.13 7.58 +/-9.14 15.4 pCi/g SLN 1 06/04/06 0440 534699 3 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B AXP2 05/19/06 1856 531287 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 PD 05/19/06 0918 531278 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-1, Modified 3 DOE RESL Ni-I, Modified 39
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-01 IF Project: YANKO 1204 Sample ID: 163105003 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 91 (25%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier
- QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
40
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-01 IFS Proiect: YANKO 1204 Sample ID: 163105004 Client ID: YANK001 Matrix: SE Vol. Recv.:
Collect Date: 05-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 25.9%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.733 +/-0.145 0.0463 +/-0.145 0.0983 pCi/g MJH1 05/31/06 2154 531444 1 Americium-241 U -0.0647 +/-0.114 0.0915 +/-0.114 0.189 pCi/g Bismuth-212 0.287 +/-0.189 0.106 +/-0.189 0.224 pCi/g Bismuth-214 0.412 +/-0.0789 0.026 +/-0.0789 0.0543 pCi/g Cesium-134 U 0.0209 +/-0.0212 0.0167 +/-0.0212 0.0351 pCi/g Cesium- 137 0.139 +/-0.0314 0.0115 +/-0.0314 0.0244 pCi/g Cobalt-60 0.132 +/-0.037 0.0145 +/-0.037 0.0313 pCi/g Europium-152 U -0.00476 +/-0.0452 0.0371 +/-0.0452 0.077 pCi/g Europium-154 U 0.0523 +/-0.0521 0.0472 +/-0.0521 0.100 pCi/g Europium-155 U 0.0396 +/-0.0448 0.0411 +/-0.0448 0.0844 pCi/g Lead-212 0.615 +/-0.0762 0.023 +/-0.0762 0.0473 pCi/g Lead-214 0.567 +/-0.084 0.0242 +/-0.084 0.0504 pCi/g Manganese-54 U -0.00048 +/-0.0163 0.0134 +/-0.0163 0.0284 pCi/g Niobium-94 U 0.00895 +1-0.0155 0.0135 +1-0.0155 0.0282 pCi/g Potassium-40 12.1 +1-1.05 0.118 +/-1.05 0.259 pCi/g Radium-226 0.412 +/-0.0789 0.026 +/-0.0789 0.0543 pCi/g Silver-108m U 0.00226 +/-0.0144 0.0127 +/-0.0144 0.0264 pCi/g Thallium-208 0.233 +/-0.0425 0.0133 +/-0.0425 0.0279 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -6.07 +/-4.72 4.07 +/-4.72 8.30 pCi/g SLNI 05/27/06 0727 531622 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021IB AXP2 05/19/06 1856 531287 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 PD 05/19/06 0918 531278 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-I, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 41
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-01 IFS Proiect: YANK01204 Sample ID: 163105004 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 85 (25%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
42
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-015F Project: YANKO 1204 Sample ID: 163105005 Client ID: YANK001 Matrix: SE Vol. Recv.:
Collect Date: 05-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 21.6%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS Actinium-228 0.766 +/-0.152 0.039 +/-0.152 0.0827 pCi/g MJH1 05/31/06 2155 531444 1 Americium-241 U 0.0219 +/-0.0815 0.0728 +/-0.0815 0.150 pCi/g Bismuth-212 0.397 +/-0.168 0.0853 +/-0.168 0.180 pCi/g Bismuth-214 0.481 +/-0.0706 0.0217 +/-0.0706 0.0455 pCi/g Cesium-134 UUI 0.00 +/-0.0227 0.0155 +/-0.0227 0.0324 pCi/g Cesium-137 U 0.00673 +/-0.0142 0.0124 +/-0.0142 0.026 pCi/g Cobalt-60 U 0.0228 +/-0.0199 0.0145 +/-0.0199 0.0308 pCi/g Europium-152 U 0.0041 +/-0.0333 0.0305 +/-0.0333 0.0635 pCi/g Europium-154 U -0.015 +/-0.0458 0.0372 +/-0.0458 0.0792 pCi/g Europium-155 UUI 0.00 +/-0.0621 0.0393 +/-0.0621 0.0811 pCi/g Lead-212 0.753 +/-0.0729 0.019 +/-0.0729 0.0393 pCi/g Lead-214 0.631 +/-0.0836 0.0212 +/-0.0836 0.0442 pCi/g Manganese-54 U 0.00443 +/-0.0143 0.0127 +/-0.0143 0.0267 pCi/g Niobium-94 U 0.00862 +/-0.0131 0.0115 +/-0.0131 0.024 pCi/g Potassium-40 13.6 +/- 1.25 0.100 +1-1.25 0.218 pCi/g Radium-226 0.481 +/-0.0706 0.0217 +/-0.0706 0.0455 pCi/g Silver-108m U 0.00145 +/-0.0115 0.0103 +/-0.0115 0.0214 pCi/g Thallium-208 0.216 +/-0.0322 0.0114 +/-0.0322 0.0239 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -1.48 +/-4.24 3.58 +/-4.24 7.30 pCi/g SLNI 05/27/06 0828 531622 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B AXP2 05/19/06 1856 531287 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 PD 05/19/06 0918 531278 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-1, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 43
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-015F Proiect: YANKO 1204 Sample ID: 163105005 Client ID: YANKOOI Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 71 (25%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GCIMS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
44
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-005F Proiect: YANKO 1204 Sample ID: 163105006 Client ID: YANK001 Matrix: SE Vol. Recv.:
Collect Date: 05-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 4.04%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.604 +/-0.119 0.0333 +/-0.119 0.0714 pCi/g MJHI 05/31/06 2158 531444 1 Americium-241 U -0.0427 +/-0.062 0.054 +/-0.062 0.111 pCi/g Bismuth-212 0.384 +/-0.180 0.0807 +/-0.180 0.171 pCi/g Bismuth-214 0.451 +/-0.0676 0.0189 +/-0.0676 0.0397 pCi/g Cesium-134 UUI 0.00 +/-0.0235 0.0136 +/-0.0235 0.0285 pCi/g Cesium-137 U 0.0108 +/-0.015 0.0121 +/-0.015 0.0253 pCi/g Cobalt-60 U - 2.170E- +/-0.0138 0.0117 +/-0.0138 0.0253 pCi/g 05 Europium- 152 U 0.0223 +/-0.0369 0.0288 +/-0.0369 0.0598 pCi/g Europium-154 U 0.0113 +/-0.0431 0.0375 +/-0.0431 0.080 pCi/g Europium-155 UIUI 0.00 +/-0.0558 0.0306 +/-0.0558 0.063 pCi/g Lead-212 0.584 +/-0.0602 0.0161 +/-0.0602 0.0333 pCi/g Lead-214 0.431 +/-0.0639 0.0187 +/-0.0639 0.039 pCi/g Manganese-54 U-0.000375 +/-0.0149 0.011 +/-0.0149 0.0232 pCi/g Niobium-94 U 0.0114 +/-0.0113 0.0103 +/-0.0113 0.0217 pCi/g Potassium-40 10.9 +/-0.928 0.0987 +/-0.928 0.216 pCi/g Radium-226 0.451 +/-0.0676 0.0189 +/-0.0676 0.0397 pCi/g Silver-108m U 0.00371 +/-0.010 0.00924 +/-0.010 0.0194 pCi/g Thallium-208 0.168 +/-0.033 0.0108 +/-0.033 0.0227 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -3.87 +/-4.61 3.94 +/-4.62 8.03 pCi/g SLNI 05/27/06 1527 531622 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B AXP2 05/19/06 1856 531287 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 PD 05/19/06 0918 531278 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-1, Modified 45
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-005F Project: YANK0 1204 Sample ID: 163105006 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 88 (25%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
46
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-003F Project: YANKO 1204 Sample ID: 163105007 Client ID: YANKOO Matrix: SE Vol. Recv.:
Collect Date: 05-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 17.9%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.617 +/-0.163 0.0484 +/-0.163 0.106 pCi/g MJHI 06/01/06 0536 531444 1 Americium-241 U 0.0462 +/-0.0903 0.0784 +/-0.0903 0.162 pCi/g Bismuth-212 0.476 +/-0.239 0.123 +/-0.239 0.263 pCi/g Bismuth-214 0.424 +/-0.0791 0.0293 +/-0.0791 0.0623 pCi/g Cesium-134 U 0.0354 +/-0.0203 0.0204 +/-0.0203 0.0433 pCi/g Cesium-137 0.0672 +/-0.0349 0.0143 +/-0.0349 0.0308 pCi/g Cobalt-60 U -0.00226 +/-0.0263 0.0189 +/-0.0263 0.0412 pCi/g Europium-152 U -0.0164 +/-0.0494 0.0404 +/-0.0494 0.0849 pCi/g Europium-154 U 0.0252 +/-0.0611 0.0537 +/-0.0611 0.117 pCi/g Europium-155 U 0.0457 +/-0.0487 0.0457 +/-0.0487 0.0947 pCi/g Lead-212 0.643 +/-0.0743 0.022 +/-0.0743 0.0459 pCi/g Lead-214 0.497 +/-0.0858 0.0289 +/-0.0858 0.0608 pCi/g Manganese-54 U -0.00392 +/-0.0199 0.0162 +/-0.0199 0.0348 pCi/g Niobium-94 U -0.00193 +/-0.0196 0.0143 +/-0.0196 0.0306 pCi/g Potassium-40 11.5 +/-1.12 0.124 +/-1.12 0.282 pCi/g Radium-226 0.424 +/-0.0791 0.0293 +/-0.0791 0.0623 pCi/g Silver-108m U -0.00521 +/-0.0151 0.013 +/-0.0151 0.0276 pCi/g Thallium-208 0.194 +/-0.0457 0.0159 +/-0.0457 0.0338 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -3.75 +/-4.48 3.83 +/-4.48 7.79 pCi/g SLN1 05/27/06 1628 531622 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021 B AXP2 05/19/06 1856 531287 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 PD 05/19/06 0918 531278 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-I, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 47
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-003F Project: YANK01204 Sample ID: 163105007 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 84 (25%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
48
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-016F Project: YANKO 1204 Sample ID: 163105008 Client ID: YANK001 Matrix: SE Vol. Recv.:
Collect Date: 15-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 22%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date . Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.621 +/-0.122 0.0435 +/-0.122 0.0939 pCi/g MJH1 06/01/06 0536 531444 1 Americium-241 U 0.0459 +/-0.107 0.0957 +/-0.107 0.198 pCi/g Bismuth-212 0.314 +/-0.197 0.0902 +/-0.197 0.194 pCi/g Bismuth-214 0.376 +/-0.0745 0.0226 +/-0.0745 0.0481 pCi/g Cesium-134 U 0.0219 +/-0.0182 0.017 +/-0.0182 0.036 pCi/g Cesium-137 U 0.0161 +/-0.0219 0.0126 +/-0.0219 0.0269 pCi/g Cobalt-60 U 0.0149 +/-0.0182 0.0167 +/-0.0182 0.0361 pCi/g Europium-152 U -0.0045 +/-0.0403 0.0342 +/-0.0403 0.0719 pCi/g Europium-154 U 0.0228 +/-0.0492 0.0438 +/-0.0492 0.0949 pCi/g Europium-155 U 0.0303 +/-0.0411 0.0397 +/-0.0411 0.0822 pCi/g Lead-212 0.479 +/-0.0638 0.0206 +/-0.0638 0.0429 pCi/g Lead-214 0.442 +/-0.0706 0.0245 +/-0.0706 0.0515 pCi/g Manganese-54 U 0.0254 +/-0.0193 0.0136 +/-0.0193 0.0291 pCi/g Niobium-94 U 0.0192 +/-0.0129 0.0124 +/-0.0129 0.0262 pCi/g Potassium-40 11.2 +/-1.03 0.110 +/-1.03 0.247 pCi/g Radium-226 0.376 +/-0.0745 0.0226 +/-0.0745 0.0481 pCi/g Silver-108m U 0.00904 +/-0.0136 0.0127 +/-0.0136 0.0267 pCi/g Thallium-208 0.174 +/-0.0402 0.0119 +/-0.0402 0.0253 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -5.24 +/-4.38 3.77 +/-4.38 7.69 pCi/g SLNI 05/27/06 1729 531622 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B AXP2 05/19/06 1856 531287 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 PD 05/19/06 0918 531278 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-I, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 49
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-016F Project: YANK01204 Sample ID: 163105008 ClientID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 82 (25%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
50
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-OOIF Proiect: YANKO 1204 Sample ID: 163105009 Client ID: YANKOO Matrix: SE Vol. Recv.:
Collect Date: 04-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 29.8%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.831 +/-0.201 0.068 +/-0.201 0.145 pCi/g MJHI 06/01/06 1000 531444 1 Americium-241 U 0.0912 +/-0.0978 0.0862 +/-0.0978 0.178 pCi/g Bismuth-212 0.466 +/-0.367 0.146 +/-0.367 0.308 pCi/g Bismuth-214 0.511 +/-0.0976 0.034 +/-0.0976 0.0717 pCi/g Cesium-134 U 0.0457 +/-0.0382 0.0252 +/-0.0382 0.053 pCi/g Cesium-137 0.260 +/-0.0408 0.0173 +/-0.0408 0.0367 pCi/g Cobalt-60 0.575 +/-0.0748 0.0186 +/-0.0748 0.0406 pCi/g Europium-152 U -0.0188 +/-0.0529 0.0433 +/-0.0529 0.0907 pCi/g Europium-154 U 0.00 +/-0.00 0.0511 +/-0.00 0.112 pCi/g Europium-155 U 0.063 +/-0.0841 0.048 +/-0.0841 0.0991 pCi/g Lead-212 0.858 +/-0.0923 0.0258 +/-0.0923 0.0535 pCi/g Lead-214 0.611 +/-0.0987 0.0311 +/-0.0987 0.0651 pCi/g Manganese-54 U --0.00443 +/-0.0231 0.0189 +/-0.0231 0.0402 pCi/g Niobium-94 U 0.00885 +/-0.0194 0.0169 +/-0.0194 0.0357 pCi/g Potassium-40 13.8 +/-1.32 0.156 +/-1.32 0.346 pCi/g Radium-226 0.511 +/-0.0976 0.034 +/-0.0976 0.0717 pCi/g Silver-108m U -0.0022 +/-0.0207 0.016 +/-0.0207 0.0335 pCi/g Thallium-208 0.252 +/-0.0503 0.0196 +/-0.0503 0.0413 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -1.07 +/-5.17 4.36 +/-5.17 8.88 pCi/g SLN1 05/27/06 1830 531622 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B AXP2 05/19/06 1856 531287 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 PD 05/19/06 0918 531278 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-1, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 51
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-OOIF Proiect: YANKO1204 Sample ID: 163105009 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 59 (25%-125%)
Notes:
The Qualifiers in this report are defined as follows:
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC. is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
52
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-002F Project: YANKO 1204 Sample ID: 163105010 Client ID: YANK001 Matrix: SE Vol. Recv.:
Collect Date: 04-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 18.1%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.401 +/-0.123 0.0498 +/-0.123 0.107 pCi/g MJHI 06/01/06 1000 531444 1 Americium-241 U -0.0267 +/-0.0778 0.0728 +/-0.0778 0.151 pCi/g Bismuth-212 0.345 +/-0.188 0.114 +/-0.188 0.241 pCi/g Bismuth-214 0.365 +/-0.0708 0.0227 +/-0.0708 0.0484 pCi/g Cesium-134 U 0.0228 +/-0.0169 0.0162 +/-0.0169 0.0345 pCi/g Cesium-137 0.0278 +/-0.0218 0.0111 +/-0.0218 0.0239 pCi/g Cobalt-60 0.0545 +/-0.0283 0.0144 +/-0.0283 0.0314 pCi/g Europium-152 U 0.014 +/-0.0419 0.0341 +/-0.0419 0.0715 pCi/g Europium-154 U 0.0594 +/-0.0525 0.0487 +/-0.0525 0.105 pCi/g Europium-155 U 0.00518 +/-0.043 0.0396 +/-0.043 0.0817 pCi/g Lead-212 0.463 +/-0.0582 0.0196 +/-0.0582 0.0407 pCi/g Lead-214 0.398 +/-0.0726 0.0244 +/-0.0726 0.0511 pCi/g Manganese-54 U -0.00887 +/-0.0155 0.0129 +/-0.0155 0.0278 pCi/g Niobium-94 U -0.0103 +/-0.0143 0.0113 +/-0.0143 0.0241 pCi/g Potassium-40 10.9 +/-0.991 0.121 +/-0.991 0.269 pCi/g Radium-226 0.365 +/-0.0708 0.0227 +/-0.0708 0.0484 pCi/g Silver-108m U -0.00217 +/-0.0128 0.0112 +/-0.0128 0.0236 pCi/g Thallium-208 0.146 +/-0.0333 0.0133 +/-0.0333 0.0281 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -4.66 +/-8.24 7.06 +/-8.24 14.6 pCi/g SLNI 06/03/06 2242 531654 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B AXP2 05/19/06 1856 531287 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 PD 05/19/06 0918 531278 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-1, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 53
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-002F Proiect: YANKO 1204 Sample ID: 163105010 Client ID: YANKOO 1 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mid Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 62 (25%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
54
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-004F Project: YANK01204 Sample ID: 163105011 Client ID: YANKOOI Matrix: SE Vol. Recv.:
Collect Date: 04-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 22.7%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.886 +1-0.150 0.0456 +/-0.150 0.0956 pCi/g MJHI 06/01/06 1001 531444 1 Americium-241 U -0.0371 +/-0.102 0.0826 +/-0.102 0.170 pCi/g Bismuth-212 0.563 +/-0.203 0.0974 +/-0.203 0.204 pCi/g Bismuth-214 0.541 +/-0.0816 0.0236 +/-0.0816 0.0491 pCi/g Cesium-134 UUI 0.00 +/-0.0221 0.0136 +/-0.0221 0.0285 pCi/g Cesium-137 0.0492 +/-0.0259 0.0116 +/-0.0259 0.0243 pCi/g Cobalt-60 0.0838 +/-0.0404 0.0116 +/-0.0404 0.025 pCi/g Europium-152 U 0.00342 +/-0.0433 0.0317 +/-0.0433 0.0657 pCi/g Europium- 154 U 0.0287 +/-0.0475 0.0415 +/-0.0475 0.0877 pCi/g Europium- 155 U 0.0663 +/-0.0516 0.0366 +/-0.0516 0.075 pCi/g Lead-212 0.932 +/-0.100 0.0195 +/-0.100 0.040 pCi/g Lead-214 0.638 +/-0.0926 0.023 +/-0.0926 0.0476 pCi/g Manganese-54 U 0.014 +/-0.0158 0.013 +/-0.0158 0.0271 pCi/g Niobium-94 U 0.013 +/-0.0136 0.0119 +/-0.0136 0.0249 pCi/g Potassium-40 14.1 +/-1.13 0.122 +/-1.13 0.261 pCi/g Radium-226 0.541 +/-0.0816 0.0236 +/-0.0816 0.0491 pCi/g Silver-108m U -0.0106 +/-0.0124 0.0103 +/-0.0124 0.0215 pCi/g Thallium-208 0.256 +/-0.0435 0.0119 +/-0.0435 0.0248 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -4.77 +/-6.05 5.23 +/-6.06 10.8 pCi/g SLNI 06/03/06 2313 531654 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B AXP2 05/19/06 1856 531287 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 PD 05/19/06 0918 531278 The following Analytical Methods were performed Method Description I EML HASL 300. 4.5.2.3 2 DOE RESL Ni-1, Modified 55
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-004F Proiect: YANK01204 Sample ID: 163105011 Client ID: YANKOOI Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 66 (25°/.-125%/6)
Notes:
The Qualifiers in this report are defined as follows:
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
56
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Ce-rtificatp nf AnAlveid Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-006F Project: YANKO 1204 Sample ID: 163105012 Client ID: YANK001 Matrix: SE Vol. Recv.:
Collect Date: 04-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 24.6%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gammna,Solid FSS GAM & ALL FSS Actinium-228 0.750 +/-0.123 0.0533 +/-0.123 0.114 pCi/g MJH1 06/01/06 1236 531444 1 Americium-241 U -0.166 +/-0.0914 0.0694 +/-0.0914 0.143 pCi/g Bismuth-212 0.594 +/-0.221 0.124 +/-0.221 0.263 pCi/g Bismuth-214 0.435 +/-0.0671 0.0293 +/-0.0671 0.0617 pCi/g Cesium-134 U 0.0238 +/-0.0484 0.0214 +/-0.0484 0.045 pCi/g Cesium-137 0.147 +/-0.0358 0.0153 +/-0.0358 0.0325 pCi/g Cobalt-60 0.182 +/-0.0381 0.0163 +/-0.0381 0.0355 pCi/g Europium-152 U 0.0282 +/-0.0544 0.0423 +/-0.0544 0.0881 pCi/g Europium-154 U 0.0685 +/-0.060 0.0551 +/-0.060 0.118 pCi/g.
Europium-155 U 0.0696 +/-0.0653 0.0495 +/-0.0653 0.102 pCi/g Lead-212 0.718 +/-0.0549 0.0255 +/-0.0549 0.0527 pCi/g Lead-214 0.558 +/-0.0708 0.0324 +/-0.0708 0.0674 pCi/g Manganese-54 U 0.0148 +/-0.0189 0.0171 +/-0.0189 0.0362 pCi/g Niobium-94 U 0.000519 +/-0.0177 0.0154 +/-0.0177 0.0324 pCi/g Potassium-40 13.2 +/-0.836 0.135 +/-0.836 0.298 pCi/g Radium-226 0.435 +/-0.0671 0.0293 +/-0.0671 0.0617 pCi/g Silver-108m U -0.00981 +/-0.018 0.0147 +/-0.018 0.0307 pCi/g Thallium-208 0.213 +/-0.041 0.0157 +/-0.041 0.0331 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -2.58 +/-4.12 3.54 +/-4.12 7.29 pCi/g SLN1 06/03/06 2345 531654 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B AXP2 05/19/06 1856 531287 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 PD 05/19/06 0918 531278 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 DOE RESL Ni-I, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 57
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-006F Project: YANK01204 Sample ID: 163105012 Client ID: YANKOO Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 64 (25%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
58
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-007F Proiect: YANK01204 Sample ID: 163105013 Client ID: YANK001 Matrix: SE Vol. Recv.:
Collect Date: 04-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 23%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.671 +1-0.151 0.0738 +1-0.151 0.156 pCi/g MJHI 06/01/06 1237 531444 1 Americium-241 U 0.0308 +/-0.0323 0.0312 +/-0.0323 0.0639 pCi/g Bismuth-212 0.708 +/-0.298 0.165 +/-0.298 0.345 pCi/g Bismuth-214 0.634 +/-0.103 0.0397 +/-0.103 0.0827 pCi/g Cesium-134 U 0.0387 +/-0.029 0.0269 +/-0.029 0.0562 pCi/g Cesium-137 0.080 +/-0.0383 0.022 +/-0.0383 0.0459 pCi/g Cobalt-60 0.083 +/-0.0391 0.0207 +/-0.0391 0.0444 pCi/g Europium-152 U -0.0522 +/-0.0598 0.0512 +/-0.0598 0.106 pCi/g Europium-154 U -0.0542 +/-0.0815 0.0669 +/-0.0815 0.142 pCi/g Europium-155 U 0.0676 +/-0.0524 0.0496 +/-0.0524 0.102 pCi/g Lead-212 0.749 +/-0.0605 0.029 +/-0.0605 0.0597 pCi/g Lead-214 0.582 +/-0.0941 0.0375 +/-0.0941 0.0777 pCi/g Manganese-54 U --0.00264 +/-0.0262 0.0224 +/-0.0262 0.047 pCi/g Niobium-94 U -0.0179 +/-0.0265 0.0191 +/-0.0265 0.040 pCi/g Potassium-40 12.3 +/-0.980 0.161 +/-0.980 0.351 pCi/g Radium-226 0.634 +/-0.103 0.0397 +/-0.103 0.0827 pCi/g Silver-108m U 0.0167 +/-0.021 0.0181 +/-0.021 0.0377 pCi/g Thallium-208 0.264 +/-0.0519 0.0194 +/-0.0519 0.0406 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -2.34 +/-3.85 3.30 +/-3.85 6.81 pCi/g SLNI 06/04/06 0016 531654 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B A.XP2 05/19/06 1856 531287 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 PD 05/19/06 0918 531278 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-1, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 59
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-007F Proiect: YANK01204 Sample ID: 163105013 Client ID: YANK00 1 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 77 (25%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
60
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-009F Project: YANKO 1204 Sample ID: 163105014 Client ID: YANK001 Matrix: SE Vol. Recv.:
Collect Date: 04-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 26.1%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS Actinium-228 0.668 +/-0.145 0.0572 +/-0.145 0.122 pCi/g MJH1 06/01/06 1237 531444 1 Americium-241 U-0.000611 +/-0.0214 0.0192 +/-0.0214 0.0395 pCi/g Bismuth-212 0.638 +/-0.246 0.105 +/-0.246 0.225 pCi/g Bismuth-214 0.418 +/-0.0801 0.0291 +/-0.0801 0.0613 pCi/g Cesium-134 UUI 0.00 +/-0.0382 0.022 +/-0.0382 0.0462 pCi/g Cesium-137 0.130 +/-0.0414 0.0147 +/-0.0414 0.0312 pCi/g Cobalt-60 0.192 +/-0.0462 0.0161 +/-0.0462 0.0351 pCi/g Europium-152 U -0.0105 +/-0.0423 0.0356 +/-0.0423 0.0744 pCi/g Europium-154 U -0.0153 +/-0.0589 0.0482 +/-0.0589 0.104 pCi/g Europium-155 U 0.0259 +/-0.0352 0.0312 +/-0.0352 0.0643 pCi/g Lead-212 0.753 +/-0.0485 0.0196 +/-0.0485 0.0407 pCi/g Lead-214 0.518 +/-0.0661 0.0245 +/-0.0661 0.0514 pCi/g Manganese-54 U 0.00765 +/-0.0202 0.0174 +/-0.0202 0.0367 pCi/g Niobium-94 U 0.00514 +/-0.0153 0.0134 +/-0.0153 0.0283 pCi/g Potassium-40 12.7 +/-0.809 0.137 +/-0.809 0.303 pCi/g Radium-226 0.418 +/-0.0801 0.0291 +/-0.0801 0.0613 pCi/g Silver-108m U -0.0059 +/-0.0132 0.0115 +/-0.0132 0.0243 pCi/g Thallium-208 0.235 +/-0.0389 0.0144 +/-0.0389 0.0305 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -3.71 +/-4.85 4.19 +/-4.86 8.64 pCi/g SLNI 06/04/06 0048 531654 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B AXP2 05/19/06 1856 531287 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 PD 05/19/06 0918 531278 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-l, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 61
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-009F Project: YANKO 1204 Sample ID: 163105014 Client ID: YANKOO Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 76 (25%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UlI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
62
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-OIOF Proiect: YANKO 1204 Sample ID: 163105015 Client ID: YANKOO I Matrix: SE Vol. Recv.:
Collect Date: 04-MA Y-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 22.1%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.719 +/-0.165 0.0679 +/-0.165 0.146 pCi/g MJH1 06/01/06 1238 531444 1 Americium-241 U 0.00799 +/-0.0282 0.0268 +/-0.0282 0.0551 pCi/g Bismuth-212 U 0.273 +/-0.204 0.147 +/-0.204 0.313 pCi/g Bismuth-214 0.413 +/-0.0779 0.033 +/-0.0779 0.070 pCi/g Cesium-134 LJ 0.0401 +/-0.0269 0.0251 +/-0.0269 0.0531 pCi/g Cesium- 137 0.117 +/-0.0364 0.0182 +/-0.0364 0.0386 pCi/g Cobalt-60 0.0508 +/-0.039 0.0192 +/-0.039 0.042 pCi/g Europium-152 L. -0.0333 +/-0.0477 0.0415 +/-0.0477 0.0871 pCi/g Europium-154 L. -0.00612 +/-0.0606 0.0509 +/-0.0606 0.112 pCi/g Europium-155 L. 0.0368 +/-0.0444 0.0418 +/-0.0444 0.0862 pCi/g Lead-212 0.604 +/-0.048 0.0241 +/-0.048 0.050 pCi/g Lead-214 0.475 +/-0.0708 0.0341 +/-0.0708 0.0712 pCi/g Manganese-54 L 0.0117 +/-0.023 0.0201 +/-0.023 0.0428 pCi/g Niobium-94 L 0.0199 +/-0.0208 0.0189 +/-0.0208 0.040 pCi/g Potassium-40 10.8 +/-0.926 0.145 +/-0.926 0.327 pCi/g Radium-226 0.413 +/-0.0779 0.033 +/-0.0779 0.070 pCi/g Silver-108m L -0.00375 +/-0.0172 0.0151 +/-0.0172 0.0318 pCi/g Thallium-208 0.164 +/-0.0415 0.0219 +/-0.0415 0.046 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 LJ -3.8 +/-4.72 4.08 +/-4.72 8.41 pCi/g SLN1 06/04/06 0120 531654 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash SoilPrep, GL-RAD-A-021B AXP2 05/19/06 1856 531287 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 PD 05/19/06 0918 531278 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 DOE RESL Ni-1, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 63
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-OIOF Proiect: YANK01204 Sample ID: 163105015 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 67 (25%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
64
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-012F Proiect: YANK01204 Sample ID: 163105016 Client ID: YANK001 Matrix: SE Vol. Recv.:
Collect Date: 04-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 28.6%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Gamma Spec Analysis GammaSolid-FSS GAM & ALL FSS Actinium-228 0.901 +/-0.176 0.0485 +/-0.176 0.102 pCi/g MJH1 06/01/06 1238 531444 1 Americium-241 U 0.014 +/-0.094 0.0811 +/-0.094 0.167 pCi/g Bismuth-212 0.644 +/-0.247 0.104 +/-0.247 0.218 pCi/g Bismuth-214 0.549 +/-0.086 0.027 +/-0.086 0.0564 pCi/g Cesium-134 U 0.0359 +/-0.0257 0.0186 +/-0.0257 0.0388 pCi/g Cesium-137 0.194 +/-0.0344 0.0153 +/-0.0344 0.0319 pCi/g Cobalt-60 0.403 +/-0.0592 0.0141 +/-0.0592 0.0302 pCi/g Europium-152 U -0.0075 +/-0.0415 0.0368 +/-0.0415 0.0765 pCi/g Europium-154 U 0.016 +/-0.0496 0.0422 +/-0.0496 0.0898 pCi/g Europium-155 U 0.0703 +/-0.0676 0.0456 +/-0.0676 0.0939 pCi/g Lead-212 0.838 +/-0.0881 0.0309 +/-0.0881 0.0632 pCi/g Lead-214 0.748 +/-0.102 0.0272 +/-0.102 0.0565 pCi/g Manganese-54 U 0.00225 +/-0.0176 0.0154 +/-0.0176 0.0322 pCi/g Niobium-94 U 0.000771 +/-0.0154 0.0129 +/-0.0154 0.027 pCi/g Potassium-40 15.2 +/-1.40 0.107 +/-1.40 0.233 pCi/g Radium-226 0.549 +/-0.086 0.027 +/-0.086 0.0564 pCi/g Silver-108m U 0.0065 +/-0.0146 0.0131 +/-0.0146 0.0272 pCi/g Thallium-208 0.279 +/-0.0443 0.0125 +/-0.0443 0.0264 pCi/g Rad Liquid Scintillation Analysis Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -2.72 +/-7.85 6.67 +/-7.85 13.7 pCi/g SLN1 06/04/06 0151 531654 2 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B AXP2 05/19/06 1856 531287 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 PD 05/19/06 0918 531278 The following Analytical Methods were performed Method Description I EML HASL 300, 4.5.2.3 2 DOE RESL Ni-1, Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits 65
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-012F Project: YANK01204 Sample ID: 163105016 Client ID: YANKOO Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Surrogate/Tracer recovery Test Recovery% Acceptable Limits Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 73 (25%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
66
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-008F Proiect: YANK01204 Sample ID: 163105017 Client ID: YANKOOI Matrix: SE Vol. Recv.:
Collect Date: 05-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 24.2%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.0374 +/-0.065 0.0506 +/-0.065 0.186 pCi/g LCW1 06/06/06 2133 535134 1 Curium-242 U 0.00 +/-0.0708 0.00 +/-0.0708 0.0979 pCi/g Curium-243/244 U -0.00756 +/-0.0635 0.0359 +/-0.0636 0.157 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U - 0.00586 +/-0.0492 0.0278 +/-0.0493 0.122 pCi/g LCW1 06/06/06 1737 535138 2 Plutonium-239/240 U 0.0244 +/-0.0478 0.00 +/-0.0479 0.0661 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 2.14 +/-12.6 10.5 +/-12.6 21.7 pCi/g LCW1 06/08/06 2032 535141 3 Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.704 +/-0.156 0.0384 +/-0.156 0.0813 pCi/g MJHI 06/01/06 1238 531444 4 Americium-241 U -0.0245- +/-0.0522 0.0475 +/-0.0522 0.0975 pCi/g Bismuth-212 0.533 +/-0.212 0.0839 +/-0.212 0.177 pCi/g Bismuth-214 0.511 +/-0.0766 0.0201 +/-0.0766 0.0421 pCi/g Cesium-134 UUI 0.00 +/-0.0241 0.0147 +/-0.0241 0.0306 pCi/g Cesium-I 37 0.220 +/-0.0387 0.0106 +/-0.0387 0.0223 pCi/g Cobalt-60 U 0.0195 +/-0.0266 0.0125 +/-0.0266 0.0267 pCi/g Europium-152 U - 0.00792 +/-0.033 0.0289 +/-0.033 0.0601 pCi/g Europium-154 U - 0.00843 +/-0.0361 0.0294 +/-0.0361 0.0632 pCi/g Europium-155 U 0.0606 +/-0.0567 0.0403 +/-0.0567 0.0825 pCi/g Lead-212 0.718 +/-0.0705 0.0182 +/-0.0705 0.0375 pCi/g Lead-214 0.598 +/-0.0811 0.021 +/-0.0811 0.0436 pCi/g Manganese-54 U 0 .000493 +/-0.0132 0.0115 +/-0.0132 0.0242 pCi/g Niobium-94 U 0.00753 +/-0.0118 0.0108 +/-0.0118 0.0225 pCi/g Potassium-40 12.8 +/-0.954 0.0896 +/-0.954 0.195 pCi/g Radium-226 0.511 +/-0.0766 0.0201 +/-0.0766 0.0421 pCi/g Silver-108m U - 0.00385 +/-0.011 0.00936 +/-0.011 0.0196 pCi/g Thallium-208 0.219 +/-0.0354 0.0111 +/-0.0354 0.0232 pCi/g Rad Gas Flow Proportional Counting GFPC,S90, solid-ALL FSS Strontium-90 U -0.0 0194 +/-0.0174 0.0205 +/-0.0174 0.046 pCi/g BXF1 06/10/06 1907 536335 5 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 3.07 +/-5.86 4.80 +/-5.87 9.98 pCi/g NXPI 05/28/06 0735 531705 6 Liquid Scint C14, SolidAILFSS 67
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-008F Project: YANKO 1204 Sample ID: 163105017 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0417 +/-0.0932 0.0769 +/-0.0932 0.159 pCi/g ATH2 06/04/06 0547 534984 7 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 11.5 +/-20.5 14.8 +/-20.5 31.2 pCi/g SLN1 05/29/06 1648 531618 9 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U -2.65 +/-7.14 6.07 +/-7.14 12.5 pCi/g SLNI 06/04/06 0223 531654 10 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0805 +/-0.266 0.221 +/-0.266 0.454 pCi/g SXEI 05/31/06 1041 531704 11 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B AXP2 05/19/06 1856 531287 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 PD 05/19/06 0918 531278 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C-01 Modified 8 EPA EERF C-01 Modified 9 DOE RESL Fe-I, Modified 10 DOE RESL Ni-I, Modified 11 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALl 79 (15%-125%)
Plutonium-242 Alphaspec Pu, Solid-ALL FSS 96 (15%6-125%)
Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FE 41 (25%-125%)
Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 70 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 81 (15%-125%)
68
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-008F Proiect: YANK01204 Sample ID: 163105017 ClientID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 51 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 63 (15%-/125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
69
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certifieate- of Ana1v6iq Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-013F Project: YANK01204 Sample ID: 163105018 Client ID: YANKOOI Matrix: SE Vol. Recv.:
Collect Date: 04-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 19.7%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0. 0381 +/-0.0661 0.0515 +/-0.0662 0.189 pCi/g LCWI 06/06/06 2133 535134 1 Curium-242 U -0.0 0885 +/-0.0744 0.042 +/-0.0745 0.184 pCi/g Curium-243/244 U -0. 0308 +/-0.0696 0.073 +/-0.0696 0.233 pCi/g AIphaspec Pu, Solid-ALL FSS Plutonium-238 U -0. 0142 +/-0.0279 0.0675 +/-0.0279 0.295 pCi/g LCW1 06/07/06 1003 535138 2 Plutonium-239/240 U -0. 0284 +/-0.0394 0.0954 +/-0.0395 0.351 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U - -1.48 +/-6.99 5.91 +/-7.00 12.2 pCi/g LCWI 06/08/06 2103 535141 3 Rad Gamma Spec Analysis Gamma,Solid-FSS GAM & ALL FSS Actinium-228 0.526 +/-0.122 0.0492 +/-0.122 0.0983 pCi/g MJHI 06/01/06 1244 531444 4 Americium-241 U 0. 0427 +/-0.0671 0.0561 +/-0.0671 0.112 pCi/g Bismuth-212 ().292 +/-0.202 0.117 +/-0.202 0.233 pCi/g Bismuth-214 (0.416 +/-0.0757 0.0262 +/-0.0757 0.0523 pCi/g Cesium-134 U (0.036 +/-0.0305 0.0188 +/-0.0305 0.0375 pCi/g Cesium-137 U 0.0 0771 +/-0.0221 0.0155 +/-0.0221 0.0309 pCi/g Cobalt-60 U 0.0 0148 +/-0.0165 0.0141 +/-0.0165 0.0281 pCi/g Europium-152 U -0. 0709 +/-0.0541 0.0381 +/-0.0541 0.0762 pCi/g Europium-154 U -0. 0286 +/-0.0494 0.0394 +/-0.0494 0.0787 pCi/g Europium-155 U 0.00 0963 +/-0.0463 0.0418 +/-0.0463 0.0836 pCi/g Lead-212 ( ).576 +/-0.0665 0.0206 +/-0.0665 0.0412 pCi/g Lead-214 0).470 +/-0.0799 0.0282 +/-0.0799 0.0564 pCi/g Manganese-54 U -0.0 0391 +/-0.0168 0.0145 +/-0.0168 0.029 pCi/g Niobium-94 U 0.0 0862 +/-0.0147 0.013 +/-0.0147 0.026 pCi/g Potassium-40 10.6 +/-0.918 0.119 +/-0.918 0.238 pCi/g Radium-226 01.416 +/-0.0757 0.0262 +/-0.0757 0.0523 pCi/g Silver-108m U 0.00 0776 +/-0.0145 0.0128 +/-0.0145 0.0256 pCi/g Thallium-208 01.189 +/-0.0397 0.0138 +/-0.0397 0.0275 pCi/g Rad Gas Flow Proportional Counting GFPC,S90, solid-ALL FSS Strontium-90 U 0. 0129 +/-0.019 0.0191 +/-0.019 0.043 pCi/g BXFI 06/10/06 1907 536335 5 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 5.31 +/-6.34 5.12 +/-6.34 10.6 pCi/g NXPI 05/28/06 0807 531705 6 Liquid Scint C14, SolidAllFSS 70
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-013F Proiect: YANKO 1204 Sample ID: 163105018 Client ID: YANKOO Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Liquid Scintillation Analysis Liquid Scint C14, SolidAll,FSS Carbon-14 U 0. +/-0.103 0.0848 +/-0.103 0.175 pCi/g ATH2 06/04/06 0750 534984 7 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 11.3 +/-19.4 14.1 +/-19.5 29.7 pCi/g SLN1 05/29/06 1705 531618 9 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U - -4.88 +/-4.47 3.90 +/-4.47 8.04 pCi/g SLNI 06/04/06 0255 531654 10 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U ().252 +/-0.260 0.210 +/-0.260 0.434 pCi/g SXEI 05/30/062354 531704 11 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GL-RAD-A-021B AXP2 05/19/06 1856 531287 Dry Soil Prep Dry Soil Prep GL-RAD-A-021 PD 05/19/06 0918 531278 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-11-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C-01 Modified 8 EPA EERF C-01 Modified 9 DOE RESL Fe-I, Modified 10 DOE RESL Ni-I, Modified 11 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 75 (15%-125%)
Plutonium-242 Alphaspec Pu, Solid-ALL FSS 56 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Pu24 I, Solid-ALL F5 71 (25%-6125%)
Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 73 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 79 (15%-/125%)
71
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: June 14, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-013F Project: YANK01204 Sample ID: 163105018 Client ID: YANKOOl Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 56 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-/125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
72
QUALITY CONTROL DATA 73
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Report Date: June 14, 2006 Client : Connecticut Yankee Atomic Power Page 1 of 9 362 Injun Hollow Rd East Hampton, Connecticut
Contact:
Mr. Jack McCarthy Workorder: 163105 Parmname NOM Samole Oual QC Units RPD% REC% Range Anlst Date Time Rad Alpha Spec Batch 535134 QC1201105085 163105017 DUP Americium-241 U -0.0374 U 0.0655 pCi/g 732 (0%- 100%) .CWI 06/06/06 21:33 Uncert: +/-0.065 +/-0.0856 TPU: +/-0.065 +/-0.0861 Curium-242 U 0.00 U 0.00 pCi/g 0 (0%- 100%)
Uncert: +/-0.0708 +/-0.0656 TPU: +/-0.0708 +/-0.0656 Curium-243/244 U -0.00756 U -0.063 pCi/g 157 (0% - 100%)
Uncert: +/-0.0635 +/-0.0412 TPU: +/-0.0636 +/-0.0421 QC1201105087 LCS Americium-241 12.9 11.7 pCi/g 91 (75%-125%) 06/06/06 21:33 Uncert: +/-0.987 TPU: +/-1.82 Curium-242 U 0.00 pCi/g Uncert: +/-0.0427 TPU: +/-0.0427 Curium-243/244 15.7 14.0 pCi/g 89 (75%-125%)
Uncert: +/-1.08 TPU: +/-2.12 QC1201105084 MB Americium-241 U 0.0943 pCi/g 06/06/06 21:33 Uncert: +/-0.111 TPU: +/-0.112 Curium-242 U 0.00 pCi/g Uncert: +/-0.061 TPU: +/-0.061 Curium-243/244 U -0.00741 pCi/g Uncert: +/-0.0622 TPU: +/-0.0623 Americium-24 I 12.9 U -0.0374 11.7 pCi/g 91 (75%-125%) 06/06/06 21:33 Uncert: +/-0U065 +/-0.981 TPU: +/-0.065 +/-1.81 Curium-242 U 0.00 U 0.00 pCi/g Uncert: +/-0.0708 +/-0.0482 TPU: +/-0.0708 +/-0.0482 Curium-243/244 15.8 U -0.00756 13.8 pCi/g 87 (75%-125%)
Uncert: +/-0.0635 +/-1.07 TPU: +/-0.0636 +/-2.08 Batch 535138 QC1201105089 163105017 DUP Plutonium-238 U -0.00586 U -0.00933 pCi/g 46 (0%- 100%) LCWI 06/07/06 10:03 74
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 163105 Page 2 of 9 Parmname NOM . ..
Samnle
.. r-Mg Oual QC Units RPD% REC% Range Anist Date Time Rad Alpha Spec Batch 535138 Uncert: +/-0.0492 +/-0.0183 TPU: +/-0.0493 +/-0.0183 Plutonium-239/240 U 0.0244 U -0.00932 pCi/g 447 (0%- 100%)
Uncert: +/-0.0478 +/-0.0183 TPU: +/-0.0479 +/-0.0183 QC1201105091 LCS Plutonium-238 U 0.00106 pCi/g (75%-125%) 06/06/06 21:33 Uncert: +/-0.0577 TPU: +/-0.0577 Plutonium-239/240 11.9 10.6 pCi/g 89 (75%-125%)
Uncert: +/-1.04 TPU: +/-1.58 QC1201105088 MB Plutonium-238 U -0.0139 pCi/g 06/07/06 10:03 Uncert: +/-0.0719 TPU: +/-0.0719 Plutonium-239/240 U -0.0987 pCi/g Uncert: +/-0.0536 TPU: +/-0.0546 QC1201105090 163105017 MS Plutonium-238 U -0.00586 U -0.0214 pCi/g (75%-125%) 06/06/06 21:33 Uncert: +/-0.0492 +/-0.0922 TPU: +/-0.0493 +/-0.0922 Plutonium-239/240 11.9 U 0.0244 12.5 pCi/g 105 (75%-125%)
Uncert: +/-0.0478 +/-1.46 TPU: +/-0.0479 +/-2.17 Batch 535141 QC1201105093 163105017 DUP Plutonium-241 U 2.14 U -1.35 pCi/g 0 (0% - 100%) .CW I 06/08/06 22:05 Uncert: +/-12.6 +/-5.34 TPU: +/-12.6 +/-5.35 QC1201105095 LCS Plutonium-241 136 114 pCi/g 84 (75%-125%) 06/08/06 23:08 Uncert: +/-10.1 TPU: +/-15.5 QCI201105092 MB Plutonium-241 U 2.49 pCi/g 06/08/06 21:34 Uncert: +/-6.09 TPU: +/-6.09 QC1201105094 163105017 MS Plutonium-241 137 U 2.14 127 pCi/g 93 (75%-125%) 06/08/06 22:37 Uncert: +/-12.6 +/-9.05 TPU: +/-12.6 +/-15.0 Rad Gamma Spec Batch 531444 QC1201096204 163105001 DUP Actinium-228 0.657 0.787 pCi/g 18 (0% - 100%) MJH I 06/02/06 11:55 Uncert: +/-0.147 +/-0.181
+/-0.181 75
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 163105 Page 3 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Gamma Spec Batch 531444 TPU: +/-0.147 Americium-241 U 0.0197 U 0.00783 pCi/g 86 (0%- 100%)
Uncert: +/-0.135 +/-0.0361 TPU: +/-0.135 +/-0.0361 Bismuth-212 0.270 U 0.215 pCi/g 22 (0%- 100%)
Uncert: +/-0.294 +/-0.363 TPU: +/-0.294 +/-0.363 Bismuth-214 0.430 UUI 0.00 pCi/g 8* (0%- 100%)
Uncert: +/-0.0735 +/-0.0986 TPU: +/-0.0735 +/-0.0986 Cesium-134 UUI 0.00 U 0.0594 pCi/g 17 (0%- 100%)
Uncert: +/-0.0318 +/-0.0406 TPU: +/-0.0318 +/-0.0406 Cesium- 137 0.0857 0.0823 pCi/g 4 (0%- 100%)
Uncert: +/-0.0355 +/-0.0423 TPU: +/-0.0355 +/-0.0423 Cobalt-60 0.0507 0.108 pCi/g 72 (0%- 100%)
Uncert: +/-0.0266 +/-0.0498 TPU: +/-0.0266 +/-0.0498 Europium- 152 U -0.00125 U -0.0242 pCi/g 180 (0%- 100%)
Uncert: +/-0.0441 +/-0.0667 TPU: +/-0.0441 +/-0.0667 Europium- 154 U 0.0628 U -0.022 pCi/g 415 (0%- 100%)
Uncert: +/-0.0565 +/-0.0877 TPU: +/-0.0565 +/-0.0877 Europium- 155 UUI 0.00 UUI 0.00 pCi/g 24 (0%- 100%)
Uncert: +/-0.0699 +/-0.0782 TPU: +/-0.0699 +/-0.0782 Lead-212 0.710 0.740 pCi/g 4 (0% - 20%)
Uncert: +/-0.0836 +/-0.0659 TPU: +/-0.0836 +/-0.0659 Lead-214 0.491 0.572 pCi/g 15 Uncert: +/-0.0798 +/-0.0863 TPU: +/-0.0798 +/-0.0863 Manganese-54 U 0.00641 U 0.00847 pCi/g 28 (0% - 100%)
Uncert: +/-0.0164 +/-0.0425 TPU: +/-0.0164 +/-0.0425 Niobium-94 U 0.0108 U -0.00216 pCi/g 300 (0%- 100%)
Uncert: +/-0.0148 +/-0.0247 TPU: +/-0.0148 +/-0.0247 Potassium-40 11.9 12.6 pCi/g 6 (0%-20%)
Uncert: +/-1.05 +/-0.965 TPU: +/-1.05 +/-0.965 Radium-226 0.430 0.467 pCi/g 8 (0%- 100%)
Uncert: +/-0.0735 +/-0.0986 TPU: +/-0.0735 +/-0.0986 Silver-108m U -0.00638 U 0.0115 pCi/g 700 (0%- 100%)
Uncert: +/-0.0136 +/-0.0229 76
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 163105 Page 4 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 531444 TPU: +/-0.0136 +/-0.0229 Thallium-208 0.215 0.249 pCi/g 14 (0%- 100%)
Uncert: +/-0.0408 +/-0.0592 QC1201096205 LCS TPU: +/-0.0408 +/-0.0592 Actinium-228 U -0.14 pCi/g 06/02/06 11:55 Uncert: +/-0.429 TPU: +/-0.429 Americium-24 I 23.4 24.1 pCi/g 103 (75%-125%)
Uncert: +/-3.07 TPU: +/-3.07 Bismuth-212 U -0.522 pCi/g Uncert: +/-0.818 TPU: +/-0.818 Bismuth-214 U 0.0187 pCi/g Uncert: +/-0.246 TPU: +/-0.246 Cesium- 134 U 0.0489 pCi/g Uncert: +/-0.118 TPU: +/-0.118 Cesium-137 9.64 10.7 pCi/g 111 (75%-125%)
Uncert: +/-0.808 TPU: +/-0.808 Cobalt-60 15.0 16.4 pCi/g 109 (75%-125%)
Uncert: +/-1.43 TPU: +/-1.43 Europium-152 U -0.0654 pCi/g Uncert: +/-0.253 TPU: +/-0.253 Europium- 154 U 0.0234 pCi/g Uncert: +/-0.256 TPU: +/-0.256 Europium-155 U -0.174 pCi/g Uncert: +/-0.327 TPU: +/-0.327 Lead-212 U 0.141 pCi/g Uncert: +/-0.182 TPU: +/-0.182 Lead-214 U -0.0253 pCi/g Uncert: +/-0.191 TPU: +/-0.191 Manganese-54 U -0.041 pCi/g Uncert: +/-0.124 TPU: +/-0.124 Niobium-94 U 0.0474 pCi/g Uncert: +/-0.103 TPU: +/-0.103 Potassium-40 U 0.516 pCi/g 77
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 163105 Page 5 of 9 Parmname NOM Samole Oual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 531444 Uncert: +/-0.947 TPU: +/-0.947 Radium-226 U 0.0187 pCi/g (75%-125%)
Uncert: +/-0.246 TPU: +/-0.246 Silver-I 08m U 0.0347 pCi/g Uncert: +/-0.136 TPU: +/-0.136 Thallium-208 U 0.141 pCi/g Uncert: +1-0.105 TPU: +1-0.105 QC1201096203 MB Actinium-228 U 0.047 pCi/g 06/03/06 12:45 Uncert: +/-0.0622 TPU: +/-0.0622 Americium-24 I U -0.0397 pCi/g Uncert: +/-0.0695 TPU: +/-0.0695 Bismuth-212 U 0.0403 pCi/g Uncert: +/-0.104 TPU: +/-0.104 Bismuth-214 U 0.0185 pCi/g Uncert: +/-0.0236 TPU: +/-0.0236 Cesium- 134 U 0.00684 pCi/g Uncert: +/-0.0134 TPU: +/-0.0134 Cesium- 137 U 0.0139 pCi/g Uncert: +/-0.0105 TPU: +1-0.0105 Cobalt-60 U -0.00948 pCi/g Uncert: +1-0.0105 TPU: +1-0.0105 Europium- 152 U -2.390E-05 pCi/g Uncert: +/-0.0276 TPU: +/-0.0276 Europium-154 U -0.0124 pCi/g Uncert: +/-0.0303 TPU: +/-0.0303 Europium- 155 U -0.0106 pCi/g Uncert: +/-0.0268 TPU: +/-0.0268 Lead-212 U 0.0167 pCi/g Uncert: +/-0.0177 TPU: +/-0.0177 Lead-214 U 0.0112 pCi/g Uncert: +/-0.0205 TPU: +/-0.0205 78
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 163105 Page 6 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Gamma Spec Batch 531444 Manganese-54 U 0.00725 pCi/g Uncert: +/-0.0121 TPU: +/-0.0121 Niobium-94 U -0.00341 pCi/g Uncert: +/-0.0111 TPU: +/-0.0111 Potassium-40 U 0.214 pCi/g Uncert: +/-0.126 TPU: +/-0.126 Radium-226 U 0.0185 pCi/g Uncert: +/-0.0236 TPU: +/-0.0236 Silver- 108m U -0.0106 pCi/g Uncert: +/-0.00889 TPU: +/-0.00889 Thallium-208 U 0.0102 pCi/g Uncert: +/-0.0123 TPU: +/-0.0123 Rad Gas Flow Batch 536335 QC1201107675 163105017 DUP Strontium-90 U -0.00194 U -0.015 pCi/g 0 (0% - 100%) BXFI 06/11/06 10:58 Uncert: +/-0.0174 +/-0.0182 TPU: +/-0.0174 +/-0.0182 QC1201107677 LCS Strontium-90 1.48 1.56 pCi/g 105 (75%-125%) 06/11/06 10:59 Uncert: +/-0.0872 TPU: +/-0.099 QC1201107674 MB Strontium-90 U -0.00598 pCi/g 06/11/06 10:58 Uncert: +/-0.0102 TPU: +/-0.0102 QC1201107676 163105017 MS Strontium-90 1.57 U -0.00194 1.62 pCi/g 104 (75%-125%) 06/11/06 10:59 Uncert: +/-0.0174 +/-0.103 TPU: +/-0.0174 +/-0.114 Rad Liquid Scintillation Batch 531618 QC1201096632 163173001 DUP Iron-55 U 10.3 U 5.38 pCi/g 0 (0% - 100%) SLNI 05/31/06 12:49 Uncert: +/-20.1 +/-18.0 TPU: +/-20.1 +/-18.1 QC1201096634 LCS Iron-55 437 428 pCi/g 98 (75%-125%) 05/31/06 13:22 Uncert: +/-40.6 TPU: +/-62.3 QC1201096631 MB Iron-55 U 3.58 pCi/g 05/31/06 12:32 79
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 163105 Page 7 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Liquid Scintillation Batch 531618 Uncert: +/-24.7 TPU: +/-24.7 QC1201096633 163173001 MS Iron-55 569 U 10.3 544 pCi/g 96 (75%-125%) 05/31/06 13:05 Uncert: +/-20.1 +/-39.3 TPU: +/-20.1 +/-69.3 Batch 531622 QC1201096645 163173001 DUP Nickel-63 U -6.64 U -5.49 pCi/g 0 (0% - 100%) SLNI 05/28/06 01:38 Uncert: +/-7.30 +/-4.33 TPU: +/-7.31 +/-4.33 QC1201096647 LCS Nickel-63 362 301 pCi/g 83 (75%-125%) 05/28/06 03:40 Uncert: +/-7.49 TPU: +/-11.1 QC1201096644 MB Nickel-63 U -1.66 pCi/g 05/28/06 00:37 Uncert: +/-3.41 TPU: +/-3.41 QC1201096646 163173001 MS Nickel-63 460 U -6.64 395 pCi/g 86 (75%-125%) 05/28/06 02:39 Uncert: +/-7.30 +/-9.22 TPU: +/-7.31 +/-14.9 Batch 531654 QCl201096728 163105010 DUP Nickel-63 U -4.66 U -9.09 pCi/g 0 (0% - 100%) SLNI 06/04/06 03:58 Uncert: +/-8.24 +/-7.46 TPU: +/-8.24 +/-7.47 QC1201096730 LCS Nickel-63 258 235 pCi/g 91 (75%-125%) 06/04/06 04:46 Uncert: +/-12.2 TPU: +/-13.6 QC1201096727 MB Nickel-63 U 0.387 pCi/g 06/08/06 22:07 Uncert: +/-4.73 TPU: +/-4.73 QC1201096729 163105010 MS Nickel-63 286 U -4.66 268 pCi/g 94 (75%-125%) 06/04/06 04:30 Uncert: +/-8.24 +/-12.8 TPU: +/-8.24 +/-14.5 Batch 531704 QC1201096868 162583001 DUP Technetium-99 U 0.161 U 0.239 pCi/g 0 (0% - 100%) SXEI 05/31/06 00:27 Uncert: +/-0.254 +/-0.273 TPU: +/-0.255 +/-0.273 QC1201096870 LCS Technetium-99 12.5 11.1 pCi/g 89 (75%-125%) 05/31/06 01:00 Uncert: +/-0.474 TPU: +/-0.545 80
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 163105 Page 8 of 9 Parmname NOM Sample Qual C Units RPD% REC% Range Anist Date Time Rad Liquid Scintillation Batch 531704 QC1201096867 MB Technetium-99 U 0.163 pCi/g 05/31/06 00:11 Uncert: +/-0.214 TPU: +/-0.214 QC1201096869 162583001 MS Technetium-99 13.1 U 0.161 11.6 pCi/g 89 (75%-125%) 05/31/06 00:44 Uncert: +/-0.254 +/-0.583 TPU: +/-0.255 +/-0.649 Batch 531705 QC1201096878 162583001 DUP Tritium U 1.17 U 6.01 pCi/g 0 (0% - 100%) NXPI 05/28/06 09:10 Uncert: +/-4.09 +/-4.70 TPU: +/-4.09 +/-4.70 QC1201096880 LCS Tritium 41.4 44.8 pCi/g 108 (75%-125%) 05/28/06 10:14 Uncert: +/-5.68 TPU: +/-5.73 QC1201096877 MB Tritium U 0.0641 pCi/g 06/03/06 05:11 Uncert: +/-0.533 TPU: +/-0.533 QC1201096879 162583001 MS Tritium 45.7 U 1.17 52.3 pCi/g 114 (75%-125%) 05/28/06 09:42 Uncert: +/-4.09 +/-6.44 TPU: +/-4.09 +/-6.50 Batch 534699 QC1201104074 163105003 DUP Nickel-63 U 6.33 U 10.5 pCi/g 0 (0%- 100%) SLNI 06/04/06 07:46 Uncert: +/-9.13 +/-8.74 TPU: +/-9.14 +/-8.76 QC1201104076 LCS Nickel-63 1190 983 pCi/g 83 (75%-125%) 06/04/06 11:01 Uncert: +/-22.7 TPU: +/-58.9 QC1201104073 MB Nickel-63 U 9.47 pCi/g 06/04/06 06:13 Uncert: +/-8.66 TPU: +/-8.68 QC1201104075 163105003 MS Nickel-63 1280 U 6.33 1020 pCi/g 79 (75%-125%) 06/04/06 09:58 Uncert: +/-9.13 +/-23.6 TPU: +/-9.14 +/-64.5 Batch 534984 QC1201104746 163173001 DUP Carbon- 14 U 0.00714 U 0.00246 pCi/g 0 (0% - 100%) ATH2 06/05/06 03:00 Uncert: +/-0.0996 +/-0.103 TPU: +/-0.0996 +/-0.103 QC1201104748 LCS Carbon- 14 12.1 11.3 pCi/g 94 (75%-125%) 06/05/06 05:20 81
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 163105 Page 9 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time Rad Liquid Scintillation Batch 534984 Uncert: +/-0.855 TPU: +/-0.873 QC1201104745 MB Carbon-14 U -0.0368 pCi/g 06/05/06 00:57 Uncert: +/-0.101 TPU: +/-0.101 QC1201104747 163173001 MS Carbon-14 12.9 U 0.00714 12.1 pCi/g 94 (75%-125%) 06/05/06 05:02 Uncert: +/-0.0996 +/-0.917 TPU: +/-0.0996 +/-0.936 Notes:
The Qualifiers in this report are defined as follows:
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.
- Indicates analyte is a surrogate compound.
A The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.
For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.
Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.
82
General Narrative Page 1 of 105
CASE NARRATIVE For CONNECTICUT YANKEE RE: Soil PO# 002332 Work Order: 168404 SDG: MSR #06-0652, 06-0675, 06-0687, 06-0688, 06-0707, 06-0743, 06-0755 August 15, 2006 Laboratory Identification:
General Engineering Laboratories, LLC Mailing Address:
P.O. Box 30712 Charleston, South Carolina 29417 Express Mail Delivery and Shipping Address:
2040 Savage Road Charleston, South Carolina 29407 Telephone Number:
(843) 556-8171 Summary:
Sample receipt The sample(s) for this Project arrived at General Engineering Laboratories, LLC, (GEL) in Charleston, South Carolina on May 5, May 9, May 12, May 17, May 26, June 2, June 8, 2006. All sample containers arrived without any visible signs of tampering or breakage. The chain of custody contained the proper documentation and signatures.
The laboratory received the following sample(s):
Sample ID Client Sample ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP INC.
P.O. Box 30712
- Charleston, SC 29417
- 2040 Savage Road (29407)
Page 2 of 105 Phone (843) 556-8171 *Fax (843) 766-1178. www.gel.com
168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-O0IF 168404015 9106-0010-012F Items of Note:
At the request of Dale Randall on July 20, 2006, GEL analyzed the above samples according to the spreadsheet in the attached email.
Case Narrative:
Sample analyses were conducted using methodology as outlined in General Engineering Laboratories (GEL) Standard Operating Procedures. Any technical or administrative problems during analysis, data review, and reduction are listed below by analytical parameter.
Analytical Reqluest:
Seven soil samples were reanalyzed for FSSALL, except gamma and Sr-90.
Four soil samples were reanalyzed for FSSALL, except gamma and Ni-63.
Two soil samples were reanalyzed for FSSALL, except gamma.
Two soil samples were reanalyzed for FSALL, except gamma, Sr-90 and Ni-63.
Internal Chain of Custody:
Custody was maintained for the sample(s).
Data Package:
The enclosed data package contains the following sections: Case Narrative, Chain of Custody and Supporting Documentation and all analytical fractions.
I certify that this data package is in compliance with the SOW, both technically and for completeness, for other than the conditions detailed above. Release of the data contained in this hard copy data package has been authorized by the Laboratory Manager or a designee, as verified by the following signature.
Cheryl Jones Project Manager GENERAL ENGINEERING LABORATORIES, LLC a Member of THE GEL GROUP INC.
P.O. Box 30712
- Charleston, SC 29417 ° 2040 Savage Road (29407)
Phone (843) 556-8171
- Fax (843) 766-1178
- www.gel.com Page 3 of 105
. I!
Additional HTD analyses
Subject:
Additional HTD analyses 16&90(4 ý1, From: "Dale Randall" <randall @cyapco.com>
Date: Thu, 20 Jul 2006 11:04:54 -0400 To: "Cheryl Jones" <cj @gel.com>
CC: "Clyde Newson" <Newson@CYAPCO.com>, "John McCarthy" <McCarthy@ CYAPCO.com>
Cheryl:
Per our earlier discussion, attached is a list of samples that we would like to have analyzed to the FSSALL protocol. I have included a list of test protocols performed on each sample to date. Once you have had an opportunity to determine our options for each sample please call or e-mail me at your convenience.
Thank You, Dale (860) 267-3133 Content-Description: GEL FSSALL analyses request.xls GEL FSSALL analyses request.xlsi Content-Type: application/vnd.ms-excel
'Content-Encoding: base64 I of I Page 4 of 105 8/2/2006 7:04 PM
Done To be done Previous
'IGEL ID CY sample location IDs FSS Gain Sr-90 Ni-63 Am Pu Sr90 Pu241 Fe55 Ni63 Tc99 H3 C14 O164220008 9106-0002-007F x x x x x x x x x x 164220012 9106-0002-011F x x x x x x x x x x 9162335004 9106-0003-004F x x x x x x x x x x 162335014 9106-0003-015F x x x x x x x x x x 162832015 9106-0004-005F x x x x x x x x x x 162832009 9106-0004-015F x x x x x x x x x x 162485008 9106-0005-01OF x x x x x x X x x x 162485011 9106-0005-014F x x x x x x x x x x 162850014 9106-0006-005F x x x x x x x x x x 163741005 9106-0008-006F x x x x x x x x x x 163741009 9106-0008-008F x x x x x x x x x x 164542008 9106-0009-002F x x x x x x x x x x 164542003 9106-0009-017F K x x x x x x x x x 163105009 9106-0010-001F x x x x x x x x x x 163105016 9106-0010-012F K x X xK x K
- K
Chain of Custody and Supporting Documentation Page 6 of 105
~kva 16 !Kq0 1ý GPP-GGGR-RS 104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00371 C0 362 Injun Hollow Road, East Hampton, CT 06424
<= Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:
Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones c C .L Priority: g 30 D,[] 14 D. E- 7 D. Sample Container Size- \(.a A Z2 ,
Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0002-OOIF 5/17/06 10:42 SE C BP X X Transferred from COC 2006-00357 9106-0002-002F 511 8W06 09:43 SE C BP x Transferred from COC 2006-00361 9106-0002-003F 5/18/06 10:14 SE C BP X X Transferred from COC 2006-00361 9106-0002-004F 5/18/06 10:39 SE C BP X - Transferred from COC 2006-00361 9106-0002-005F 5/18/06 12:49 SE C BP x x Transferred from COC 2006-00364 9106-0002-006F 5/18/06 13:14 SE C BP x "_*_ x Transferred from COC 2006-00364 9106-0002-006FS 5/18/06 13:14 SE C BP x x Transferred from COC 2006-00364 9106-0002-007F 5/18/06 13:37 SE C BP x x Transferred from COC 2006-00364 9106-0002-008F 5/18/06 14:04 SE C BP x x Transferred from COC 2006-00364 NOTES: PO #: 002332 MSR #: 06- SSWP# NA Z LTP QA El Radwaste QA (I Non QA Samples Shipped Via: Internal 155 Fed Ex Container El UPS Temp.:
Deg. C El Hand Custody Sealed?
Rel'--qu ary.By Date/Time 2) l~ ived By Date/Time Custody Seal Q8 ý1 C\ýO El6Other Intact?
1'"gelinquished
- Date/Time 4) Received By Date/Time YO__ No Bill of Lading #
- 5) Relinquished By Date/Time 6) Received By Date/Time
Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 1 Major Conneeticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00372 CD 00 362 Injun Hollow Road, East Hampton, CT 06424 0 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name &Phone: Comments:
Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0
- 843 556 8171. Attn. Cheryl Jones c'n V V- V.L W~I Priority: Z 30 D. [ 14 D. E 7 D. Container 4
Sample Size-Media Type &Type "Preservation Sample Designation "ml Lab Date Time Code Code Code Come, Prese 3Sample 9106-0002-009F 5/18/06 14:28 SE C BP x Transferred from C0C2006-00364 9106-0002-01OF 5/18/06 14:50 SE C BP X X Transferred from COC 2006-00364 9106-0002-OIIF 5/19/06 08:10 SE C BP x x Transferred from COC 2006-00365 9106-0002-012F 5/19/06 08:31 SE C BP x x Transferred from COC 2006-00365 9106-0002-013F 5/19/06 09:00 SE C BP X x Transferred from COC 2006-00365 9106-0002-014F 5/19/06 09:58 SE C BP x x Transferred from COC 2006-00365 9106-0002-01FFS 5/19/06 09:58 SE C BP x - Transferred from COC 2006-00365 9106-0002-0145F 5/19/06 10:29 SE C BP X X Transferred from COC 2006-00365 9106-0002-016F 5/19/06 13:19 SE C BP x x Transferred from COC 2006-00365 NOTES: PO #: 002332 MSR #: 06- SSWP# NA [ LTP QA F Radwaste QA El Non QA Samples Shipped Via: Internal 07,5"s Fed Ex Container 0 UPS Temp.:
Deg. C DI Hand Custody Relin DateTime 2) R:eived By Dat Time Sealed?
Custody Seal 1"k _ M______n_'___ _____,'la. _ E Other Intact?
3)ý1(elinquished By Date/Time 4) Received By Date/Time BillofLading_#YO_ NO
- 5) Relinquished By Date/Time" 7qo9.Iq Bill of Lading75 #
- 6) Received By Date/Time 076J'7
Connecticut Yankee Statement of Work for Analytical Lab Services -CY-IsC-Sow-0ol Figure 1. Sample Check-in List Date/Time Ree.ived (0* "
SDG#: Ms o -c O4 -*-"
Work Order Number: C.. 2Z0 ".
ShippingChanr ID~IO~t 4U1(559/ 0 Chain of Custody# i'O , <J !
I. Custody Seals oti shipping container intact?.. Yes *" No []
- 2. Custody Seals dated and signed? Yes No[ "
- 3. Chain-of-Custody record present? Yes ]Not "
- 4. Cooler temperature -
- 5. Vermiculitelpacking materials is: Wet [] Dry ['1 I;
- 6. -Number of samples in shipping container:
- 7. Sample holding times exceeded? Yes No
- 8. Samples have' tape _hazard labels
_-eustody seals _appropriate sample labels
- 9. Samples are.'
good condition -leaking
-broken -have air bubbles
- 10. Were any anomalies identified in sample receipt? Yes[] NoXI
- 11. Description of anomalies (include sample numbers):
Sample Custodian/Laboratory:_____ Date: 0 (p Telephoned to:- ,n B Page 9 of 105
Connecticut Yankee
-CY-ISC-SOW-001 Statement of Work for Analytical Lab Services .CY-lsC-sow-oo1 Figure 1. Sample Check-in List Date/Time Recei~ved-/<ýý` t2 SDG#: /k$5 #. o O Work Order Number: "O '
Shipping C tainer - Chain of Custody #1-0 (o ,
I. Custody Seals ori shipping container intact?... Yes No [I
- 2. Custody Seals dated and signed? Yes .No [
- 3. Chain-of-Custody record present? Yes ](No[]
- 4. Cooler t.emperature o/J.5d
- 5. Vermiculite/packing materials is: Wet [] Dry ",]Il Ii..
6.: -Numberof samples in shipping container. _ _ _
- 7. Sample holding times exceeded? Yes No
.8. j eshave.:
ap._._hazard labels eustody seals *appropriate sample labels
- 9. Samples are:-
4
._* in good condition leaking
-broken -have air bubbles
- 10. Were any anomalies identified in sample receipt?. Yes [J No
- 11. Description of anomalies (include sample numbers):
Sample Custodian/Laboratory: ;'L'l-,"J . Date.: ,
Telephoned to: On By Page 10 of:105
0 SAMPLE RECEIPT & REVIEW FORM 1 ., ~*v*I,,
I 7.
lien t:
014JrORtr-
ý co Date eceied:
r- U Q~e ~PM(A)
SDGARCOC/Work Order:-ill PM use only Review (emsre non-conforming items are resolved prior to signing);
i lReceived By:
Sample Receipt Criteria CommentslQualifiers (Required for Non-Conforming Items)
Shipping containers received intact Circle Applicable: seals broken damaged container ICaibg container odter (describe) and sealed? 1.7 Samples requiring cold Circle Coolant # ice bags blue ice/ dry ice none other describe) 2 preservation within (4 +1- 2 C)?
Record preservation inethod. ,_.. . .
3 Chain included of w custody ith ship documents ment?
incale with ment? Applicab s bk-en damaged container leaking container other (describe)
SSample containers intact and circle Ap~.
sealed? 7' Samples requiring chemical 38 l ID's. containers affected and observed pH:
preservaionat proper pH?
VOA vials free of headspace Sample ID's and comtainers affected:
6(defined as < 6mm bubble)?
Are Encore containers present?
7 (If yes, immediately deliver to VOA laboratory) 8 Samples received witl holding Id's and ts affected; time?
9 Sample ID's 914COC match ID's Sample ID's and containers affected on bottles?/
Date & me on COC match date Sample ID's affected:
& tinv on bottles?
Nu her of containers received Sample IU's affected:
match number indicated on COC?
COC form is properly signed in relinquished/received sections? ( W1- :H-Air Bill Tracking #'s, &
Additional Comments
- ii ' ' I~ _ 'i -- 1. .. ..
I Vi VU 3 aRIKOI RAL) Receipt #f _______________
- If > x2 area background is observed on samples identified as "non-Suspected Hazard Information 'Si I
08 I U
regulated/non-radioactive", contact the Radiation Safety group for further iE investigation.
I i t Ml a ;-
ilo*l-Iil B )PCB Recgulated?
1'-,1la, lltr- ')ll.
I Ma~ximum Counts Observed*:',, es ce7
( J Comments:
IShipped as DOT Hazardous I
CiMaterial? If yes, contact Waste IManager or ESHManager.
P (or PMA) review of1Hazard Page 11I of 105 if/,
Hazard Class Shipped:
UN#:
Initials Dae 0z c i
ENC/ SAMPLE RECEI'TPT & REVIEWF ORM
~4T~ll1~PM use only' 1 I
Client:,C o r.. ) .tA "a.*_ Wc(, .. r,,. prior t--,S n . I Date Received: " OCo .R w u n Wi r ved prior to sRgnilg:
-Received By:
Sample Receipt Criteria Z Z Comments/Qualifiers equired for Nn.-Conforming Items)
Circle Applicable: seals broke// damaged container leaking container other (describe)
Shipping containers received intact and sealed? -
Ciric Coolant # ý7i gs blue ice dry ice none other describe)
Samples requiring cold i
2 preservation within (4 +/- 2 C)? /
Record preservation method.
Chain of custody documents included with shipment?
Sample containers intact and Cir pplicable: seals broken damaged container leaking container other (describe) sealed?
5 Samples requiring chemical Sample lO's. containers affected and observed pH:
preservation at proper pH? . .........
VOA vials free of headspace Sample 1o's and contaims affected:
(defined as < 6mm bubble)? . .. . . . .....
Are Encore containers present?
7 (If yes, immediately deliver to VOA laboratory) 8 Samples received within holdin ls and test affect**
time? /
Sample ID's on COC ma D's Sample ID's and conutiners affected:
9 on bottles?__.... .. . .... .
Date & time on COC tch date Sample ID's affected:
& time on bottles? _
Number of container received Sample ID's affected:
match number indicited on COC?
COC form is prop rly signed in 4k 005_2-1 relinquished/received sections? D- _ . .-
Air Bill ,Tracking #'s, &
Additional Comments V a ZRSO RAD Receipt #
Suspected Hazard Information 0. ';S to *If > x2 area background iscontact regulated/non-radioactive', observedthe oa Radiation Safety group for further
- investigation.
Wadiological Classification? Maximoum Counts Observed*:' wh PM
- BPCB Regulated? im , n "
S hlippedas DO!T Hazardous
[Material? If yes, contact Waste Hazard Class Shipped:
Manager or ESH Manager. N#,
MPM (or PMA) review of Hazard classitication: Initials k V Page 12 of 105 U
Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 I Major Chain of Custody Form N.20-01 Connecticut Yankee Atomic Power Company No. 2006-00312
- 362 Injun Hollow Road, East Hampton, CT 06424860_26%2556 - . "
860-267-2556 ' L .I ,,-
o Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only
, Contact Name & Phone: 'Comments:
Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)
General Engineering 2040 Savage Laboratories Road. Charleston SC. 29407 < < . ... "-.
843 556 8171. Attn. Cheryl Jones V)n V) C cL.,~ cr. ,
Priority: Z] 3U D. --] 14 D. [17 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab SampleID.
i 9106-0003-OOIF 4/24/06 14:13 SE C BP X Transferred from COC2006-00221 J
" 9106-0003-002F 4/24/06 14:39 SE C BP X Transferred from COC2006-00221
' 9106-0003-003F 4/24/06 15:01 SE C BP X Transferred from COC2006-00221 9106-0003-004F 4/25/06 08:41 SE C BP X Transferred from COC2006-00223 9106-0003-004FS 4/25/06 08:41 SE C BP X Transferred from COC2006-00223 9106-0003-005F 4/25/06 09:21 SE C BP X Transferred from COC2006-00223 9106-0003-006F 4/25/06 09:46 SE C BP X Transferred from COC2006-00223 a 9106-0003-007F 4/25/06 10:28 SE C BP X Transferred from COC2006-00223 9106-0003-008F 4/25/06 11:15 SE C BP xX' Transferred from C0C2006-00223 NOTES: PO #: 002332 MSR #: 0 6-0 6 SSWP# NA Z LTP QA El Radwaste QA El Non QA Samples Shipped Via: X,',nte'n` CýJ itiiner Combined samples 9106-0003-003F taken on 4/25/06 @08:19 and 9106-0003-003FB taken on 4/25106 @ 08:19 in order to have sufficient sample for counting. 0 Fed Ex i ,::.. :" i-Deg. CC Q UPS C] Hand Custoidy*Sealed?'
- 1) Relinquished By Date/Time 2) Recived By Date/Time CUStOdy Seal Intact?7 J c . .- 4"-g /13.'30.- / IJ Other
- 3) Relinquished By Date/Time 4) Received By Datl/Time _ _ _ _ . N .
Bill of Lading #
- 5) Relinquished By Date/Time 6) Received By Date/Time .- 52 0- '/{0- o2 4C)
Health Physics Procedure GPP-GGGR-RS 104-003 -Attachment B-CY-001 Major Health Physics Procedure GPP-GGGR-R5 104-003-Attachment B-CY-00 I Major o Chain of Custody Form No. 2006-00313 0Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 - ,,,, _ - _ ___ _ _ _ _ _ _
Project Name: Haddam Neck Decommissioning Analyses Requested M M .- ".- .4 ,
Contact Name & Phone: .. .
Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State) -.41 General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones Cn .,
Priority: 30 D., 14 D. L] 7 D. Container Sample Size- d4' Media Type &Type rsrvto Sample Designation Date Time Code Code Code Comment, Preservation *.- -. -l
A 9106-0003-009F 4/25/06 4/25/06 13:23 13:23 SE SE C C BP BP xX - - -- TrnfrefomCC20003 Transferred from COC 2006-00236 010 9106-0003-OIOF 0 9106-0003-010FS 4/25/06 13:23 SE C BP x Transferred from COC 2006-00236 il5 9106-0003-012F 4/25/06 15:12 SE C BP X Transferred from COC 2006-00236 0 9106-0003-013F 4/25/06 14:21 SE C BP X Transferred from COC 2006-00236 0 9106-0003-015F 4/26/06 08:16 SE C BP X Transferred from COC 2006-00237 9106-0003-016F 4/26/06 09:41 SE C BP X TransferredSfromCC2006-00237 9106-0003-017F 4/26/06 09:18 SE C BP X Transferred from COC 2006-00237 ,* .
NOTES: PO #: 002332 MSR #: 06- SSWP#INA Z LTPQA [I Radwaste QA EJ Non QA Samples Shipped Via: v o~ntziffier,
[ Fed Ex El UPS Li Hand
- 1) Relinquished By Date/ime 2))eceived By DateiTime El Other ~N,
- 3) Relinquished By Date/Time 4) Received By Da elTime Bill of Lading 4
- 9/2o-g%?2o- 0211
Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-00.I Figure 1. Sample Check-in List Date/Time Received: ,- -
SDG#:_ /u * -c('-
Work Order Number: "' t92-3 3 Shipping Cdntainer ID: cIT Y q'ZC0 0Q i Chain of Custody# .C.3 ,
0740 .313 004Q9
- 1. Custody Seals or shipping container intact?. -Yes [ ] No
- 2. Custody Seals dated and signed? Yesj No
- 3. Chain-of-Custody record present? Yes No [
- 4. Cooler temperature _ C1 .
- 5. Vermiculite/packing materials is: Wet f] Dry[I,]
6.: Number of samples in shipping container [i O y e- I F-O)
M1 r-ýlLn
- 7. Sample holding times exceeded? Yes [ No
.8. Samp71eph
-tape ___hazard labels
_zcustody seals -appropriate sample labels
- 9. Samples are:
good condition "=leaking
-broken .. *have air bubbles
- 10. Were any anomalies identified in sample receipt? Yes [ No Q.
1.. .Description of anomalies (include sample numbers):
Sample, Custodian/Laboratory:L ifhL 2 rcC 1 . Date
- Telephoned to: On ' 3 Page 15 of 105
SAMPLE RECEIPT & REVIEW FORM r
PM use only 'Z3135r (9112 Client: '4al-k SDG/ARCOC/Work Order:J Date Received: oN I51 6 ý7 PM(A) Review (ensure nuonconfrng items are resolved prior to sigig):
Received By: (p -rv Cc _ _ _ _ _ _ _ _ _ _ _
Sample Receipt Criteria Comments/Qualiifers (Required for Non-Conforming Items)
Shipping containers received intact Circle Applicable: seals broken damaged container leaking container nber (describe)
I sealed?
-and I Samples requiring cold Circle Coolant # ice bags blue ice dry ice none 2 preservation within (4 +/- 2 C)?
Record preservation method., / ,
Chain of custody documents included with shipment? .........
4 Sample containers intact and Circle Applicable: stea broken damaged container leaking container oie (describe) sealed? T Samples requiring chemical Smple ID's, containers affected and observed pH:
preservation at proper pH? __
6 VOA vials free of headspace Sample lO's and containers affected:
(defined as < 6am bubble.)_?
Are Encore containers present?
7 (If yes, immediately deliver to VOA laboratory) 8 Samples received within holding Id's and tests affeted; time?
9 Sample ID's on COC match ID's Smple ID's and containers affected:
on bottles?
Date & time on COC match date Sample ID's affected:
& time on bottles?
Number of containers received Sample ID's affected:
match number indicated on COC?
COC form is properly signed in relinquished/received sections?
Air Bill ,Tracking #'s, & la bL 'O OZ j Additional Comments O".- -0 "U V "'IRSO T RAD Receipt #
Information*If > x2 area background is observed on samples identified as *no-ZHo & regulated/non-radioactive", contact the Radiation Safety group for further C *_ investigation.
A IRadiological Classification? Maximum Counts Observed*: " 0D 1RA B PCB Regulated? Comments:
Shipped as DOI Hazardous C Material? If yes, contact Waste Hazard Class Shipped:
_Manager or ESH Manager. U#:
PM (or PMA) review of Hazard classification: Initials _ Dale: o 0' )
Page 16 of 105 a I ,.
Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 I Major HelhPyiI rcdr IPPIIGGR- 10-0-ttcmn BIY0 ao Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424
ýProject Name: Haddam Neck Decommissic
,ontact Name & Phone:
Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority: 0 30 D. (114 D. D] 7 D.
Samples Shipped Via:
E Fed Ex Dl uPs El Hand Ml Other Bill of Lading #
Health Phys~s Proedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major n " T i T I SCqn~~n~,~$l Yankee Atomic Power Company
- fZnjtun Hollow Road, East Hampton, CT 06424 Project.Name: Haddam Neck Decommissic Contact Name & Phone:
Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority: Z30 D.E] 14 D. M7 D.
Samples Shipped Via:
[ Fed Ex E UPS El Hand MI Other Bill of Lading #
4*7/ ' 3yy- F97Z
Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-001 Figure 1. Sample Check-in List 11 '
Date/Time Received: X-. 4.Z. 0 6 ýe ý.20 SDGN: IK6R tfO(> - 0 9 Work Order Number:- AZ,932- '/
Shipping Container ID: -7A Z35- 887z Chain of Custody # Lo-60J i
- 1. Custody Seals on shipping container intact? Yes No [
- 2. Custody Seals dated and signed? Yes No []
- 3. Chain-of-Custody record present? Yes No ]
- 4. Cooler temperature
- 5. Vermiculite/packing materials is: WetJ4 Dry []
- 6. Number of samples in shipping container:
- 7. Sample holding v
times exceeded? Yes [1 No
- 8. Samples have:
ktape hazard labels Xcustody seals __._appropriate, sample labels
- 9. Samples are:
_ in good condition ___4 eaking broken have air bubbles
- 10. Were any anomalies identified in sample receipt? Yes No [J 1I. Description of anomalies (include sample numbers):
Sample Custodiar/Laboratory:. Date , '" - d 9' ,>
Telephoned to: On -By Page 45 of 56 Page 19 of 105
. Connecticut Yankee Statement of Work for Analytical Lab Services -CY-ISC-SOW-OOI Figure 1. Sample Check-in List.
Date.ime Received.
SDG#: /WlY. (*gOO-Work Order Number: . I fez's .
"" '* 13N5 E*2- ""
Shipping CIitainer ID- " Chain ofCustody# A0o.X(n334 - (0
-'. Custody Seals on shipping container intact?: Yes (I No
- 2. Custody Seals dated and signed? Yes ] No fLJi
- 3. Chain-of-Custodiy record present? Ycs ' No [ "
.4.. Cooler temperaftur
- 5. Vermiculite/packing materials is: Wet [,2Dry t\ "
. 6. Number of sarples in shipping container: _ _ _ _;__'
- 7. Sample holding timns exceeded? "Yes[ No
.8.. Samples have:-
- . _..4 ape _hazard labels S.appropriate Sample labels
- 9. Samples are-in* good condition .(*_eaking
. . .""' -broken have air bubbles 10.
- 10. Were any anonalies identified in sample receipt? *Yes (a4 No [1"
-Description of anomalies. (include sample numibr):
i 4 !..
S'ample Cusodia/Labratzy:. Cy -
Telephonel to:_________________
PageOn 20 of 1 P.* ge .- 0 105 . . .. - . .
. .4.*"- SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM
,q - -QIn .. rq \(_0 C) C (cq-?) rQc*
dbin' 00
- ',m6i\ -'<* " i,YiC/f~
cob ch t d t-L _ _ _ __ _ _ _ _ __ _ _ _ _ _ _
b(usfec Page 21 of 105
a SAMPLE RECEIPT & REVIEW FORM ff PM use only Client: ('( LA' L.* SDG/ARCOC/Work Order: / 2, Z .
Date Received: ' . PM(A) Review (ensure non-conforning itens are resolved prior to signing)-
ReceivedBy ~(h _______________ ___
Sample Receipt Criteria Comments/Qualiflers (Required for Non-Conforming Items) other(descbe) containers received intact Circle Applicable: seals broen damaged container leaking container Shipping 1 'and sealed?
Samples requiring cold ircile Coolant # ice bags blue ice dry ice now other describe) 2 preservation within (4 + /- 2 C)?
Record preservation method. _ _.... ..... ..
Chain of custody documents lincluded with shipment?
iSample containers .
intact and Circle Applicable: seals broken daimaged container lq<K tai other (describe) sealed? - .'M _ /_a_(e_-_ooo-91t_ -,__j Samples requiring chemical "Sample M's. contliners affected and observed p4:
preservation at proper pH?
vials free of headspace Sarple ID's and conainers affected:
6- VOA (defined as < 6mm bubble)? _
Are Encore containers present?
7 (If yes, immediately deliver to VOA laboratory)
Samples received within holding Id's and tests affected:
8time?______________________ ___
9 Sample ID's on COC match ID's Se M's and contMine affected:
on bottles?
,Date & time on COC match date sampl ID's affected:
10 & time on bottles? ---- ==----
Number of containers received Sap DBaffected:
match number indicated on COC? __
12 COC form is properly signed in relinquishedreceived sections? (doc. Aoi' K-.
A1r BlTracking #'s, &
rAdid~itiional Comments E
..... ~ 19 l RAD Remeip#_ ., 'i-
- If > x2 area background is observed on samples identified as non-n o , guated/non-radioactive, conat the Radiation Safety group for fuer
.B a, , .... ...... . '- ',
AjRadio1og a C -assification?
. - MUM-AYUU1: I
- LLQcJ.
B PCB Regulied? .. munments:
P 'z4 .,5 a U'
C Material? If yes, contact Waste lazard, Class Shlipped; Manager or ESH Manager. _ FND:A Po*(h T*,yi)*w of Hazard classification:
Pffi1QPPKAknYicw of Hazard classification:
I I[1111*11 *'
-Date: (
>11 LL-ý (I
0 SAMPLE RECEIPT & REVIEW FORM PM use ofly ICfient: Vrfln b i , SDGIARCOCIWork Order: /(,, 2 .,
Date Received: = / PM(A) Review ¶e( f.ou-coutormnitems are resolved prior to siping):
Received By: (2 t1 .ex I/i C& -l ' I______
Sample Receipt Criteria Comments/Qualiflers (Required for Non-Conforming Items)
Shipping containers received intact Circle Applicable: seals broken damaged container leaking container other (describe) and sealed? _9,,.11,P__,_ ,
Samples requiring cold Circle Coolm # Ie bags blue ice dry keC o&" describe) 2 preservation within (4 +/- 2 C)?
Record preservation method. ___ __
Chain of custody documents CIO)U O.C" \/ L+-
p:_
included with shipment?
Sample intact and hicI clsbf) ef damaged containe kicoi 4sealed containers
?
Samples requiring chemical 5'npe ID's. containersaffected an=observed pH:
preservation at proper pH? .3 P 2_
VOA vials free of headspace Sample ID's and canuinem affeced:
(defined as < 6mm bubble)?
Are Encore containers present?
7 (If yes, immediately deliver to VOA laboratory) ......
'Samples received within holding Id's and test affected:
time?
SSample ID's on COC match ID's mpIIleUDs and1 containers affected:
on bottles?
Date & time on COC match date Sample ID's affected:
10
& fime on bottles?
Number of containers received Sample ID's affted:
,match number indicated on COC?
COC form is properly signed in relinquished/received sections?
rn " Cfoc 'cy£, VLu-- %AiU*,Vs C '
Cd f t) .)LL . d - (* L ..
A ir Bill ,Trac kin g # 's , & ý_v 14Additional Comments V V 0ORAD Receipt
. .f > x2 area background is observed on samples identified as 'non-Suspected Hazard Information S Za . eulated/non-radioactive', contact the Radiation Safety group for further Snvestigation.
o m m re nts :
Radiological Classificatio-n.' 'C
- 9 .
' Maximum Counts Observed*:
B BP R asueg la t?ed ....
[S ipped i .1T37 azard ous
/Material? If yes, contact Waste Hazard Class Shipped: at:
Manager or ESH Manager. UNI:
PM (or PMA) review 137.7,1 !P" 7.Cclassification:
of Hazard Initials Dat' :!,77 5 Vi
Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 0 860-267-2556
-Project Name: Haddam Neck Decommissioning uContact Name &Phone: Analyses Requested Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Cn Cn Priority: 0 30 D.E] 14 D. E] 7 D. Container Sample Isize-Media Type &Type Sample Designation Date Time Code Code Code Comment Preservation S9106-0005-OIOF 5/02/06 13:16 SE C BP x xTransferred from COC 2006-00314 9106-0005-OIF 5/02/06 13:39 SE C BP x x Transferred from COC 2006-00314 9106-0005-013F 5/02/06 14:35 SE C BP x x Transferred from COC 2006-00314 9106-0005-014F 5/02/06 15:04 SE C BP x x Transferred from COC 2006-00314 9106-0005-016F 5/02/06 13:59 SE C BP x x Transferred from COC 2006-00314 9106-0005-015F 5/03/06 08:03 SE C BP X X Transferred from COC 2006-00316 9106-0005-017F 5/03/06 08:13 SE C BP x x Transferred from COC 2006-00316 9106-0005-018F 5/03/06 09:09 SE C X BP X Transferred from COC 2006-00316 9106-0005-018FS 5/03/06 09:09 SE C BP x x Transferred from COC 2006-00316 NOTES: PO #: 002332 MSR #: 06-0675 SSWP# NA [ LTP QA El Radwaste QA [ Non QA Samples Shipped Via:
Z Fed Ex El UPS E] Hand
- 1) linquish Beyy Date/Time 21 = L Pata/Time j /p.FD- q 6 qg9E Other
- 3) R\quished By Date/Time I4) ci Date/Time
~7q.zc Bill of Lading 0
-9,95
Connecticut Yankee Statement of Work for Analytical Lab Services .Cy-Isc-sow-O01 Figure 1. Sample Check-in List.
Date/Time Received 4 Lo OLf3ý SG - , kkf*.
Work Order Number: LAA ",
Shipping Cohtainer ID: *
- 7- ROM- 4-S 52 V7 3 Chain of Custody# .,,6b4p-oo- I& L9 I1. Custody Seals o0i shipping container intact? Yes , No[]
- 2. Custody Seals dated and signed? Yes,' No [ ]
- 3. Chain-of-Custody record present? Yes J4"No []
.4. Cooler temperature I A' Iq "
- 5. Vermiculite/packingmaterials is: wet b,4"Dry t, ]
6.' Number of samples in shipping container: I *"
- 7. Sample holding times Cxceeded? Yes [ ] No LA'
- 10. Were any anomalies identified in sa' p!e receipt? Yes [I No L' rimbr fo s c s no.
- 1. -Description of anomalies,(include Sample numbers):
Page 25 of 105
,I
0 SAMPLE RECEIPT & REVIEW FORM V
PM use only Cie Date Received:
IReceived By:
topic,-
' SDGJARCOC/Work Order:
PM(A) Review (ensu -items onre..
oG2.Lt85
_ I are resolved prior to signing):
Sample Receipt Criteria Z Comments/Qualifiers (Required for Non-Conforming Items)
Circle Applicable: seals broken damaged container leaking container other (describe)
Shipping containers received intact a kclsealed? . ...
Samp requiring cold Circle Coolant # ice bags blue ice dry ice none other describe) 2 preservan, within (4 +/- 2 C)?
Record preser' *on method. _________________________
3 Chain of custody d nts l included with shi ment?
4 Sample containers intact and Circle Applicable: seals broken damaged container leaking comainter other (describe) sealed?
Samples requiring chemical Sample ID's..... miner affected and obsrved pH:
preservation at proper pH? _
6 VOA vials free of headspace _Sample ID's and containers affected:
6 (defined as < 6mm bubble)?
Are Encore containers present?
7 (If yes, immediately deliver to VOA laboratory)
- 8. Samples received within holding Id's and tests affected.
time?
9 Sample ID's on COC match ID's Sample ID's and containers affected:
on bottles?
10 Date & time on COC match date Sample ID's affected:
& time on bottles?
11 Number of containers received Sample ID's affected:
match number indicated on COC?
COC form is properly signed in 12 relinquished/received sections?
14Air Bill ,Tracking Additional Comments#Fs,& F ~1 -( £r19 5' ~4?5z
- s'(o
- 17c.
I*-0c.
PC' RSO RAD Receipt #
- ,*If > x2 area background is observed on samples identified as *non-Suspected Hazard Information a =
S. regulated/non-radioactive", contact the Radiation Safety group for finrher investigation.
'A IRadiological Classification? - Maximum Counts Olbserved*:
B ]PCB Regulated? ____Comments:
IShipped as DOI[ Hazardous C Material? If yes, contact Waste " Hazard Class Shipped:
[Manager or ESH Manager. UN#:
PM (or PMA)freview of Hazard classification: Initials Date:
U/
Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 I Major Health Physics Procedure GPP-GGGR-RS 104-003-Attachment B-CY-00 I Major Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 Troject Name: Hacam-n NeCK u.ecommissi(
ýrontact Name & Phone:
Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn.Cheryl Jones Priority: Z 30 D. [] 14 D. M] 7 D.
Samples Shipped Via:
[ Fed Ex D UPS C] Hand
[] Other Bill of Lading #
fo 44Q-1.2-
- Connecticut Yankee Statement of Work for Analytical Lab Services .CY.ISC-SOW-OOI Ci*O" Figure I. Sample Chek-in List Datenrhfe Recei ved.____________________
- " SDG#-
Work order Numbe ShippingCdntainerIDl 6 (TCO7- N-t- Chain of Custody# -
' 5 #-
- 1. Custody Seals oii shipping container intact?.
Yes t1 NokI
- 2. Custody Seals dated and signed?
Yes [No
- 3. Chain'-of-Custody record preent? *Yes 4VPNO [1
- 4. Cooler temperature .
- 5. Vermiculite/packing materials is: - Wet ()Dry i, l 6: Numberofsamplesinshippin*,lgCota-f,. tC YCk. 3 c
- 7. Sample holding times ex*eeded? Yes [ No 8amSamples have; tjane -hazard labels 1.custody seals appropriate sample labels
- 9. Samples ae:'
_Liqgood conditionlekg
_brokenm -have air bubbles
- 10. Were any anornalies identified in sampercit Yes (INo ~
- escription PI. of anomalies.(include sample numbters):
Sampleý Custodiadmaboratory: ~2Al '~k Date. Z5 L*(
Telephoned to:-n____________
Page 28 of f105
.LENGI*
/"SAMPLE RECEIPT & REVIEW FORM O4*4~~I' e onl wOR**"YP Client:
DaeRcid Received By:
V]
C n 6 v :51LJfMPM(A) one.y I_____
SDGbARCOC/Work Order: (6Cr.z.8 Z &*/,65
,, 0, Revieow (esure om-confrmin item *re resolved prior to Siglking:
___5___7__
J Sample Receipt Criteria
- z z Comments/Qualirnrs (Required for Non-Conforming Items) ircle Applicable: seals broken damaged container leaking container otler (describe)
Shipping containers received intact and sealed? __A=
Samples requiring cold Circle Cooant # ie bags blue ice dry icc odi describe 2 preservation within (4 +-A 2 C)?
Record preservation method.... C Chain of custody documents C )OUS o- b GA, included with shipment?i.
Sample containers intact and iAppyable:stablsWqcn damaged container leaking containe r (describe) sea led ? es c tr d I Di conta. obsev edqpH: )an 5 Samples requiring chemical ai . coniirs affctid and observed pH:
5 reservation at proper pH?
VOA vials free of headspace Saimple ID's and coainers affected:
(defined as < 6mm bubble)?
Are Encore containers present?
7 (If yes, immediately deliver to VOA laboratory) 8 Samples received within holding Id's and tests affected:
lime?
9 Sample ID's on COC match ID's L-ID's ad coniners affec",d:
on bottles?
a on___ _
iDate & time on COC match date Sample ID's affected:
10 & time on bottles?
,, to's aected; 1 Number of containers received match number indicated on COC?
2 COC form is properly signed in no Cb(5, CX_,, VL",Yi rtA
- I3kj relinquished/received sections? .
. . ( *i -J-L 14 Air Bill ,Tracking #s, &
Additional Cormnents "a RSO RAD Receipt I Suspected Hazard Information
- C C *If > x2 area background iscontactobserved on samples identified as non-Sui .1 regulated/non-radioactive-, the Radiation Safely group for further
- . investigation.
i Maximm Counts Observed*:
Radiological Classification?
SPCB Regulated? "V Comments:
Shipped as IX I Hazardous Material? If yes, contact Waste I Hazard Class Shipped:
Manager or ESH Manager.
PM (or PMA) review of Hazard classification: Initials Date:
age 2-7 of 105 V 11--II. II
SAMPLE RECEIPT & REVIEW FORM CONTINUATION FORM
ý'IAlp /67 932,I
-e-d F Y- -Fak-W ,, - c 0, q
-I1 -q0 (qa~I 7-o _l a~*1 oo*-
00 OO3~)
S3 0(q- "ASWvo Ho-)"
-.- 1~ ,- ( oo3--:s (C 'niv c,-de-v h cid m. '
bu~sfed 1c! p Rs
~ ~' so Page 30 of 105 11.1ýrm.[
Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 I Maj or Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00367 CD 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 3-7
/__________________
6 4________________________
W Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:
Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 294070 < o 843 556 8171. Attn. Cheryl Jones 4, *. .
Priority: Z 30 D.E[] 14 D. El 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 1 15 6 3 -E B- - - ,
9106-0008-001F 5/05/06 11:13 SE C BP X x x Transfcrred from COC # 2006-00324 9106-0008-003F 5/5/06 13:35 SE C BP X x X Transferred from COC # 2006-00325 9106-0008-004F 5/5/06 13:51 SE C BP X X X Transferred from COC U2006-00325 9106-0008-005F 5/5/06 14:17 SE C BP X x x Transferred from COC # 2006-00325 9106-0008-006F 5/5/06 14:36 SE C BP X x X Transferred from COC # 2006-00325 9106-0008-006Fs 5/5/06 14:36 SE C BP X X X Transferred from COC # 2006-00325 9106-0008-007F 5/5/06 15:03 SE C BP x ... Transferred from COC # 2006-00325 9106-0008-002F 5/5/06 13:10 SE C BP X - X x - - Transferred from COC U2006-00325 NOTES: PO#: 002332 MSR#: 06-07-3 SSWP#NA 0 LTP QA [] Radwaste QA E] Non QA Sacnples Shipped Via: Internal Container E] Fed Ex Temp.: - Deg. C
[] UPS Hand Custody Sealed?
I I /I YO NO
- 1) elinqu she Date/Time 2) e ived ate/Time Custody Seal Intact?
Other
- 3) *'inquished By Date/Time 4) de eive y V . Iate/Time YO NO 1 of Lading #
Kt 2_1 554 11(,P2_
Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-00 1 Major
- )Chain 70No. of Custody Form 2006-00366 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 860-267-2556 - - -
Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only t Contact Name & Phone: Comments:
Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 ,
843 556 817 1. Attn. Cheryl Jones rA 0 z Priority: Z 30 D. [] 14 D. [] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID
) 9106-0008-008F. 5/08/06 08:01 SE C BP X X X Transferred from COC # 2006-00327 010 9106-0008-009F 5/08/06 08:32 SE C BP X X X Transferred from COC # 2006-00327 oil 9106-0008-O0OF 5/08/06 09:09 SE C BP x x x Transferred from COC # 2006-00327 01 9106-0008-01OFS 5/08/06 09:09 SE C BP X x X Transferred from COC # 2006-00327 I 9106-0008-01 IF 5/08/06 09:30 SE C BP x x x Transferred from COC #2006-00327
)1 9106-0008-012F 5/08/06 09:53 SE C BP X 7 Transferred from COC #2006-00327
)1 9106-0008-013F 5/08/06 10:16 SE C BP x x x Transferred from COC #2006-00327 9 _106-0008-014F 5/08/06 10:47 SE C BP X x X Transferred from COC # 2006-00327 NOTES: PO #: 002332 MSR #: 06- 61q,3 SSWP#NA SLTP QA [] Radwaste QA El Non QA Samples Shipped Via: Internal Container
[ Fed Ex Temp.: -4 1 Deg. C El UPS ElHand Custody Sealed?
YO N)T 1)Relinquished By Date/Time 2) Received By Date/Time Custody Seal Intact?
3C El Other By fate/Ti a
- 3) Relinquished By Date/Time 4) Received By Date/Time Y50 NO Bill of Lading #
Connecticut Yankee Statement of Work for Analytical Lab Services cY-lsC-soW-001 Figure 1. Sample Check-in List.
Datefrime Received. 'jItZk T~3C SDG#:
Work Order Number:
Shipping CdotainerlD: * ¢ I i'() Chain of Custody# Coo'.o -0 o o "3
- 1. Custody Seals. o shipping container intact?.. Yes [No [I
- 2. Custody Seals dated and signed? Yesi[ No [
- 3. Chain-of-Pustody record present? Yes [H11o I I
-4. Cooler temperature / --
- 5. Vermiculite/packing materials is: Wet [ Dry A/}I A)]
- 6. -Numberof samples in shipping container: "
- 7. Sample holding times exceeded? Yes [ I No
- 8. Samples have:"
_tape _hazard
-. labels
_. custody seals Y_- appropriate sample labels
- 9. Samples are'
- ....*ia good condition -leaking
-broken w -have air bubbles
- 10. Were any anomalies identified in sample receipt? Yes [ ] No IL.. Description of anomalies. (include sample numbers):
" . . 5. . . .
Telephoned to: " .* ". : " - ,
On. . . = "
By_.." h.
On.By_________
Page 33 of 105 .
- ,t3 IT
- k ~0 SAMPLE RECEIPT & REVIEW FORM a
PHM an only BCflest: CcSDGIARCOCfWork Ord-:
- IDate Received: ,~M(A) PA~ Rev,~w (ensure son-conforrning items ane resufre prior to slglas:
IReceived B*.!o" ,,
Sample Receipt Criteria ComnsQulnw (Rqe fo0o-ofomn tm 1Shipping containers received intact -/ . -- ki-waer c"(d*-c)
Smlsrequiring cold We CoOlaN # ice baps blu ace dry ice brdsa 2 prsr.to within (4 +/- 2 CQ? /
/ RecdPreservation method. /
custody Sof documents inlded h with shipment?______________________
seled? ntin r intact sand atCApIhcahe snab broken daaupd conulner lek in* olmr o ID's. Wmahen affnedw arnd bserval pH:
Samles requirifg chemical
-rsration at Proper pH?_________________________
a.i'..A .
vAinsta fro%^ uPSd .n -m, e-i -- a . Sa'%
I 61(defined as < 6mm bubbleo? I/
Are containers present? -r 7 (If yea. immediately deliver to.
/
VOA laboratory)
Saples received wnthin holding m - himrd's .1.4 ~
nd am AM-
.ff..~4 time? I1.
I *_5J, ID's on COC match ID's on boules? I // - r~.. . 1.
i in'.
We- an 11' I
& time on COC match date -Y-
' S r-W
&/onbottles?
I I
Il q ~
mber of containers received 11 match number indicated on COC? / J'ctd 85C form is properly signed in 12 reliquished/recejyed sections? 7 Air Bill ,Tracking #s, &
114 Addt"na ('nni11wT~awr.q
" ' - ]I,:SO AD Receipt I . .
J SuqwpedSusedMUM- Hazard Information >identified na'/no.-radioave', scontact
~s=non* saPf as "*ow.
. the Radiation Safetygp o o*Maiumm Count Observe*: j1 aA. * "
ahpp as. Dt: .aarous .________________
Material?i If yes, contact Waste "C/s Sip:
Manager or ESM Manager.
PM (or PMA) review of Hazard classification:
Page 34 of 105
SANPLERECEIPT & REVIEW FORM
-7 YO W PM use mli' Client: Y an k . SDG/ARCO.C/Work Order: lb W7 '/
Date Received: 5"/= Im PM(A) Review (ensure aon-coforming items are resolved prior to signing):
lReceived By: C i(l.*t I( A t-A _Z_ _
Sample Receipt Criteria 4 Z Comments/Qualiflers (Required for Non-Conforming Items)
Shipping containers received intact Circle Applicable: seals broken damaged container leaking container other (describe) and sealed? do Samples requiring cold Circle Coolant # ice bags blue ice dry ice Other describe) 2 preservation within (4 +/- 2 C)?
Record preservation method. . ..
3Chain of custody documents
. included with shipmenrt?
4 Sample containers intact and / Circle Applicable: seals broken damaged container leaking container other (describe) sealed?
Samples requiring chemical Sample ID's. containers affected and observed pH:
5 preservation at proper pH?
6 VOA vials free of headspace Sample ID's and containers affected:
(defined as < 6mm bubble)? ,,
Are Encore containers present?
7 (If yes, immediately deliver to .
VOA laboratory)_,
Samples received within holding Id's and kso affecied:
time?
9 Sample ID's on COC match ID's saWMle ID's and containers afficued:
10 Date & time on COC match date JiPl IDa affected:
0 & time on bottles?
Number of containers received Sample ID's affected:
8 match number indicated on COC?
COC form is properly signed in n-o4- ,'f~qt4 Jk 2 relinquished/received sections?
14 Air Bill ,Tracking #'s, & .'j Z," 5 I //75 Additional Comments T'* RSO RAD Receipt #
-- *if > x2 area background is observed on samples identified as "non-Suspected Hazard Information *a regulated/non-radioactive", contact the Radiation Safety group for further CZ1e 4 investigation.
A fKadiological Classification? 5:XTf v' Maximum Counts Observed*: ero rnt4t B'PCB Regulated? Tv Comments:
-Shipped as DOIT Hazardous .. '
Hazard Class Shipped:
C Material? If yes, contact Waste JN#:
_Manager or ESH Manager.
PM (or PMA) review of Hazard classification: Initials Date:
/ "(
Page 35 of 105
Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-O01 Figure 1. Sample Check-in List Date/Time. Received: 5"/Atac2L (' o*l SDG#:
Work Order Number:
Shipping Cdntainer ID: -79 21 5 K-4 I 1 13 Chain of Custody'# O- ,
- 1. Custody Seals od shipping container intact?... -Yes kiNo [ ]
- 2. Custody Seals dated and signed? Yes L.,,To [I
- 3. Chaia-of-Custody record present? Yes L o [es
- 4. Cooler temperature - lot.
- 5. Vermi culite/packing materials is: Wet WI4*ry LI 6.. Number of samples in shipping container: C3 "ULlf hkt
- 7. Sample holding times exceeded? Yes-[ NDI No
- 8. Samples have:
,_Z pe ---- hazard labels custody seals ___appropriate sample labels
- 9. Samples are'
_ýýin good condition leaking broken ____have air bubbles
- 10. Were any anomalies identified in sample receipt? Yes [] No [-<
- 11. Description of anomalies (include sample numbers):
Sample. Custodian/Laboratory: '*2'*V,4 '*A " Date: __________________
Telephoned to: On By_
Page 36 of 105
, ' 1't1
Health Physics Procedure GPP-GGGR-R5104-003 -Attachment B-CY-00 I Major
/ &45-4ol -A
-o Chain of Custody Form No. 2006-00380 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road, East Hampton, CT 06424 0 860-267-2556 Project Name: Haddam Neck Decommissioning _ A,nalyses Requested -LabUse Only Contact Name & Phone: Comments:
Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 0 843 556 8171. Attn. Cheryl Jones Cin Z Priority: Z 30 D. El 14 D. E: 7 D. Container Sample Size-Media Type &Type . "
Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID
- 9106-0009-016F 5/15/06 13:28 SE C BP x x Transferred from COC 2006-00352 0.9106-0009-016FS 5/15/06 13:28 SE C BP X X Transferred from COC 2006-00352 9106-0009-017F 5/15/06 14:03 SE C BP x X Transferred from COC 2006-00352 9106-0009-01 IF 5/15/06 08:05 SE C BP x - Transferred from COC 2006-00351 p 9106-0009-013F 5/15/06 08:35 SE C BP X X Transferred from COC 2006-00351 5 9106-0009-013FS 5/15/06 08:35 SE C BP X X Transferred from COC 2006-00351 Di1 9106-0009-014F 5/15/06 08:59 SE C BP X Transferred from COC 2006-00351 9106-0009-015F 5/15/06 09:36 SE C BP X X Transferred from COC 2006-00351 NOTES: PO #: 002332 MSR #: 06-M/I SSWP# NA SLTP QA El Radwaste QA rL Non QA Samples Shipped Via: Internal Container (2 Fed Ex Temp.: __ Deg. C 0i ups Li Hand Custody Sealed?
YO NO 1)Relinquis* d By Date/Time 2) Rec v d y Date/Time Custody Seal Intact?
El Other
- 3) Relinquished By Date/Time 4) Releive By Date/Time YI1 Nf" Bill of Lading #
Health Physics Procedure GPP-GGGR-R5104-003-Attachment B-CY-001 Major I 1-J-1
' '" T IJ , , .,,
Ct Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00381 362 Injun Hollow Road, East Hampton, CT 06424 0 0860-267-2556 C..
2 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only C
Contact Name & Phone: Comments:
Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones z Priority: Z 30 D.[] 14 D. E] 7 D. Container Sample Size-Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 01 9106-0009-001F 5/11/06 13:22 SE C BP X X Transferred from COC 2006-00347 5 9106-0009-002F 5/11/06 13:46 SE C BP X X Transferred from COC 2006-00347 0*DI 9106-0009-003F 5/11/06 14:06 SE C BP x x Transferred from COC 2006-00347 9106-0009-004F 5/11106 14:30 SE C BP X X Transferred from COC 2006-00347 0I4* 9106-0009-005F 5/11/06 14:55 SE C BP X X Transferred from COC 2006-00347 Cl/ 9106-0009-007F 5/12/06 07:44 SE C BP X - - Transferred from COC 2006-00348 3 9106-0009-008F 5/12/06 08:16 SE C BP x x Transferred from COC 2006-00348 r' 9106-0009-009F 5/12/06 08:35 SE C BP X X Transferred from COC 2006-00348 64 9106-0009-01OF 5/12/06 09:07 SE C BP X X Transferred from COC 2006-00348 NOTES: PO #: 002332 MSR#: 06- SSWP# NA Z LTP QA [: Radwaste QA El Non QA Samples Shipped Via: Internal Container
[ Fed Ex Temp.: _Deg. C EUPS D Hand Custody Sealed?
YO] NO
- 1) Relinquished By Date/Time 2) ReDcUe ,y ate/Time Custody Seal Intact?
El Other
- 3) Relinquished By Date/Time 4) ReceivedtBy Date/Time YEI NT]
Bill of Lading #
ýC?11 i*/C" z3
VI.f
-v-P5r -I Connecticut Yankee Statement of Work for Analytical Lab Services CY-ISC-SOW-OOl Figure 1. Sample Check-in List Date/Time Received: 0 [o SDG#: IV S O O I ~,
Work Order Number:
Shipping Cdntainer ID: Ila Chain of Custody#
- 1. Custody Seals ori shipping container intact?: -Yes D No (I
- 2. Custody Seals dated and signed? Yes'[ 3No
- 3. Chain-of-Custody record present? Yes No t I
.4. Cooler temperature ZQ
- 5. Vermiculite/packing materials is: Wet [J.Dry'
- 6. Number of samples in shipping container:
- 7. Sample holding times exceeded? Yes D( No [ )
- 8. Samples have.-
.. a" _____hazard labels
,~ custody seals - .appropriate sample labels
- 9. Samples are:
2.?S in good condition . -*leaking
-broken _have air bubbles
- 10. Were any anomalies identified in sample receipt? Yes [ ] No 11.. . .Description of anomalies, (include sample numbers):
Sample Custodian/wlaboratory: Date.: G. ' G ':L Telephoned to: On By.
Page 39 of t05
Health Physics Procedure OPP-GGGR-R5104-003-Attachment B-CY-001 Major Health Physics Procedure GPP-GGGR-R5 104-003-Attachment B-CY-001 Major Connecticut Yankee Atomic Power Company Chain of Custody Form No. 2006-00349 362 Injux Hollow Road, East Hampton, CT 06424 860-267-2556 Project Name: Haddam Neck Decommissioning Analyses Requested Lab Use Only Contact Name & Phone: Comments:
Jack McCarthy 860-267-2556 Ext. 3024 Analytical Lab (Name, City, State)
General Engineering Laboratories 2040 Savage Road. Charleston SC. 29407 843 556 8171. Attn. Cheryl Jones Priority: 0 30 D. [: 14 D. 0 7 D. Container Media Type &Type Sample Designation Date Time Code Code Code Comment, Preservation Lab Sample ID 9106-0010-00IF 5/04/06 10:49 SE C BP X X TrasferredffromiCOC2006-00321 0'0 9106-0010-002F 5/04/06 11:12 SE C BP X X Transferred from COC 2006-00321 it 9106-0010-004F 5/04/06 12:48 SE C BP X X Transferred from COC 2006-00321 I 9106-0010-006F 5/04/06 13:34 SE C BP X X Transferred from COC 2006-00321 0 -9106-0010-007F 5/04/06 13:21 SE C BP X X Transferred from COC 2006-00321 0it 9106-0010-009F 5/04/06 14:01 SE C BP X X Transferred from COC 2006-00321 C 9106-0010-OIOF 5/04/06 14:21 SE C BP X X Transferred from COC 2006-00321 0 -9106-0010-012F 5/04/06 14:44 SE C BP X X Transferred from COC 2006-00321 I'
9106-001O-013F 5/04/06 15:06 SE C BP X Transferred from COC 2006-00321 NOTES: PO #: 002332 MSR#: 06- 0707 SSWP#INA Z LTP QA [I Radwaste QA El Non QA Samples Shipped Via: Internal Container
[ Fed Ex Temp.: /7 Deg. C EUPS El Hand CustodySealed?
1)RelinquisheoBy Date/Tithe 2) Received y Date/Time Custody Seal Intact?
El Other
- 3) Relinquished By Date ime 4)
I Received eee Byy]laeTm Date/Time Y 9VN 0 Bill of Lading #
3 q64- 3
Connecticut Yankee
-CY-ISC-SOW-001 Statement of Work for Analytical Lab Services Figure 1. Sample Check-in List
- q. 51/17/o, Date/Time Received:
SDG#: lc-4i 4j _'7fl"7 Work Order Number:
Shipping CdhtainerID: -O91 311/; SS' Chain of Custody# '10- 60 3_V I. Custody Seals orif shipping container intact? Yes Ic No [ ]
- 2. Custody Seals dated and signed? Yes "M No [C]
- 3. Chain-of-Custody record present? Yes [No[]
- 4. Cooler temperature (7 C"
- 5. Venniculite/packing materials is: Wet *]. Dry (t, 6,' -Numberof samples in shipping container: I
- 7. Sample holding times exceeded? Yes ] No
.8. Samples have:
-tape -_hazardlabels
.. Iicustody seals - appropriate sample labels
- 9. Samples are
___in good condition .AJeaking
-broken _have air bubbles
- 10. Were any anomalies identified in sample receipt? Yes [ ] No PQ
- 11. . .Description of anomalies (include sample numbers):
Sample. Custodian/Laboratory:_ Date: .- P -- O(""
Telephoned to:'On By - '
Page 41 of 105 -*1, .',1ItI
SAMPLERECEIPT & REVIEW FORM PM use only Client: (A.,tI*, XAI4 SDARCOOWork Order:
Receivedp RDate PM(A) Review e 0 prirto signing):
Received By: --- _
Sample Receipt Criteria Comments/Qualiiers (Required for Non-Conforming Items)
Circle Applicable: seals broken damaged container leaking container other (describe)
Shipping containers received intact and sealed?
CircJe Coolant # ice bags blWe ice dry ice ne other describe)
Samples requiring cold 2 preservation within (4 +/- 2 C)?
-Record preservation method.
Chain of custody documents included with shipment? _
4 Sample containers intact and Circle Applicable: seals broken damaged container leaking container other (describe) sealed?
Samples requiring chemical Sample ID's. containers affected and observed pH:
preservation at proper pH?__
6 VOA vials free of headspace Sample ID's and containers affected:
(defined as < 6mm bubble)?
Are Encore containers present?
7 (If yes, immediately deliver to VOA laboratory)
Id's and tests affected:
8 Samples received within holding time?
Sample ID's on COC match ID's Sample ID's and containers affected:
on bottles? A Sample ID's affected:
10 Date & time on COC match date
& time on bottles? _
Number of containers received Sample ID's affected:
match number indicated on COC?
12 COC form is properly signed in
-reiinuished/received sections?
14 Air Bill ,Tracking #'s, & (li-Lu Additional Comments 7 7 4RSO RAD Receipt #
I*If > x2 area background is observed on samples identified as "non-Suspected Hazard Information
- regulated/non-radioactive", contact the Radiation Safety group for further
_investigation.
A Radiological Classification? v Maximum Counts Observed*:
- PCB Regulated? V' Comments:
Shipped as D01 Hazardotus C Material? If yes, contact Waste 1"Hazard Class Shipped:
Manager or ESH Manager.
PM (or PMA) review of Hazard classification: Initials Date: /'/ ,.
I'll /
Page 42 of 105
List of current GEL Certifications as of 15 August 2006 I State Certification Alaska UST-062 Arizona AZo668 -. .
H Arkansas 88-0651 CLIA 42D0904046 California 01151ICA Colorado GenEngLabs
.C.onnectic-u.t. ... PH-0169-Dept. of Navy NFESC 413 EPA WG-15J Florida/NELAP E87156 Georgia . E87156 (FLNELAP)
______.Idaho - N/A Illinois 200029 Indiana C-SC-01 Kansas E- 10332 Kentucky __ 90129_
Maryland 270
- Massachusetts M-SCO*12 Michigan 9903 Nevada New Jersey New York 11501 North Carolina North Carolina Drinking W 45709 1North Dakota Oklahoma R-158 9904 Pennsylvania 68-485
- South Carolina 10120001110585001/10120002 Tennessee 02934 Texas TX21 3-2006A U.S. Dept. of Agriculture S-52597 I f
US Army Corps of Engineer N/A Utah 8037697376 GEL Vermont N/A Virginia 00151 Washington C223 Page 43 of 105
RADIOLOGICAL ANALYSIS Page 44 of 105
Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)
Work Order 168404 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555696 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F 1201153129 Method Blank (MB) 1201153130 168340011(9304-01-005C) Sample Duplicate (DUP) 1201153131 168340011(9304-01-005C) Matrix Spike (MS) 1201153132 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.
Page 45 of 105
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 168340011 (9304-01-005C).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Sample 168404003 (9106-0003-004F) was recounted due to high MDA.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Page 46 of 105
Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 557837 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Sample ID Client ID 168404009 9106-0006-005F 168404010 9106-0008-006F 1201158316 Method Blank (MB) 1201158317 168404009(9106-0006-005F) Sample Duplicate (DUP) 1201158318 168404009(9106-0006-005F) Matrix Spike (MS) 1201158319 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Ouality Control (OC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 168404009 (9106-0006-005F).
QC Information Page 47 of 105
All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu-i l-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555697 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 48 of 105
Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-OO1F 168404015 9106-0010-012F 1201153133 Method Blank (MB) 1201153134 168340011(9304-01-005C) Sample Duplicate (DUP) 1201153135 168340011(9304-01-005C) Matrix Spike (MS) 1201153136 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-01 1 REV# 14.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (0C0 Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 168340011 (9304-01-005C).
QC Information All of the QC samples met the required acceptance limits.
Page 49 of 105
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu- I1-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555698 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 50 of 105
Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-OOIF 168404015 9106-0010-012F 1201153137 Method Blank (MB) 1201153138 168340011(9304-01-005C) Sample Duplicate (DUP) 1201153139 168340011(9304-01-005C) Matrix Spike (MS) 1201153140 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 8.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Ouality Control (C0 Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 168340011 (9304-01-005C).
QC Information All of the QC samples met the required acceptance limits.
Page 51 of 105
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Manual Integration No manual integrations were performed on data in this batch.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: GFPC, Sr90, solid-ALL FSS Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 556350 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 52 of 105
Sample ID Client ID 168404003 9106-0003-004F 168404004 9106-0003-015F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F 1201154644 Method Blank (MB) 1201154645 168404003(9106-0003-004F) Sample Duplicate (DUP) 1201154646 168404003(9106-0003-004F) Matrix Spike (MS) 1201154647 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 10.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 168404003 (9106-0003-004F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Page 53 of 105
Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Samples 1201154644 (MB), 1201154645 (9106-0003-004F), 1201154646 (9106-0003-004F),
1201154647 (LCS), 168404003 (9106-0003-004F), 168404004 (9106-0003-015F), 168404012 (9106-0009-002F), 168404013 (9106-0009-017F), 168404014 (9106-0010-001F) and 168404015 (9106-0010-012F) were dried and reweighed due to low matrix spike/laboratory control sample recovery.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 554580 Page 54 of 105
Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F 1201150561 Method Blank (MB) 1201150562 168340012(9304-02-003C) Sample Duplicate (DUP) 1201150563 168340012(9304-02-003C) Matrix Spike (MS) 1201150564 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-005 REV# 13.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Ouality Control (OC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 168340012 (9304-02-003C).
QC Information All of the QC samples met the required acceptance limits.
Page 55 of 105
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe- 1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555722 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 56 of 105
Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-01OF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F 1201153222 Method Blank (MB) 1201153223 168340012(9304-02-003C) Sample Duplicate (DUP) 1201153224 168340012(9304-02-003C) Matrix Spike (MS) 1201153225 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 168340012 (9304-02-003C).
QC Information All of the QC samples met the required acceptance limits.
Page 57 of 105
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni- 1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 555723 Prep Batch Number: 554650 Dry Soil Prep GL-RAD-A-021 Batch Number: 554649 Page 58 of 105
Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-01OF 168404008 9106-0005-014F 168404009 9106-0006-005F 1201153226 Method Blank (MB) 1201153227 168340012(9304-02-003C) Sample Duplicate (DUP) 1201153228 168340012(9304-02-003C) Matrix Spike (MS) 1201153229 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 8.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 168340012 (9304-02-003C).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Page 59 of 105
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: LSC, Tritium Dist, Solid-HTD2,ALL FSS Analytical Method: EPA 906.0 Modified Analytical Batch Number: 554582 Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F 1201150569 Method Blank (MB) 1201150570 168340011(9304-01-005C) Sample Duplicate (DUP) 1201150571 168340011(9304-01-005C) Matrix Spike (MS) 1201150572 Laboratory Control Sample (LCS)
Page 60 of 105
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 12.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QCQ Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 168340011 (9304-01-005C).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis Sample 168404010 (9106-0008-006F) was recounted due to high MDA.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Page 61 of 105
Qualifier information Manual qualifiers were not required.
Method/Analysis Information Product: Liquid Scint C14, Solid AII,FSS Analytical Method: EPA EERF C-01 Modified Analytical Batch Number: 554583 Sample ID Client ID 168404001 9106-0002-007F 168404002 9106-0002-01 IF 168404003 9106-0003-004F 168404004 9106-0003-015F 168404005 9106-0004-005F 168404006 9106-0004-015F 168404007 9106-0005-OIOF 168404008 9106-0005-014F 168404009 9106-0006-005F 168404010 9106-0008-006F 168404011 9106-0008-008F 168404012 9106-0009-002F 168404013 9106-0009-017F 168404014 9106-0010-001F 168404015 9106-0010-012F 1201150573 Method Blank (MB) 1201150574 168404003(9106-0003-004F) Sample Duplicate (DUP) 1201150575 168404003(9106-0003-004F) Matrix Spike (MS) 1201150576 Laboratory Control Sample (LCS)
SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.
Calibration Information:
Calibration Information All initial and continuing calibration requirements have been met.
Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).
Page 62 of 105
Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.
Quality Control (QC) Information:
Blank Information The blank volume is representative of the sample volume in this batch.
Designated QC The following sample was used for QC: 168404003 (9106-0003-004F).
QC Information All of the QC samples met the required acceptance limits.
Technical Information:
Holding Time All sample procedures for this sample set were performed within the required holding time.
Preparation Information All preparation criteria have been met for these analyses.
Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.
Miscellaneous Information:
NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. A nonconformance report (NCR) was not generated for this SDG.
Additional Comments Additional comments were not required for this sample set.
Qualifier information Manual qualifiers were not required.
Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.
Review Validation:
GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.
Page 63 of 105
The following data validator verified the information presented in this case narrative:
Reviewer/Date: w o/
- q/Ze4 Page 64 of 105
SAMPLE DATA
SUMMARY
Page 65 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Report for YANKOO Connecticut Yankee Atomic Power Co.
Client SDG: 168404 GEL Work Order: 168404 The Qualifiers in this report are defined as follows:
- A quality control analyte recovery is outside of specified acceptance criteria
ND The analyte concentration is not detected above the detection limit.
The above sample is reported on a dry weight basis except where prohibited by the analytical procedure.
Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.
This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.
Reviewed by Page 66 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-007F Proiect: YANKO1204 Sample ID: 168404001 Client ID: YANKOOI Matrix: SE Vol. Recv.:
Collect Date: 18-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 20.9%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0. 0762 +/-0.102 0.00 +/-0.102 0.0956 pCi/g BXL1 08/11/06 1336 555696 1 Curium-242 U 0.00 +/-0.0995 0.00 +/-0.0995 0.138 pCi/g Curium-243/244 U -0.0 0853 +/-0.0717 0.0405 +/-0.0717 0.177 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.199 +/-0.228 0.181 +/-0.229 0.444 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U 0. 0341 +/-0.129 0.120 +/-0.129 0.323 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-24I U 10.0 +/-6.64 5.08 +/-6.72 10.7 pCi/g BXLI 08/16/06 1220 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 4.17 +/-6.67 5.28 +/-6.67 11.4 pCi/g DFAI 08/09/06 1128 554582 4 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.0813 +/-0.0797 0.0634 +/-0.0797 0.132 pCi/g ATH2 08/09/06 0324 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 9.90 +/-48.1 32.0 +/-48.1 65.9 pCi/g MXPI 08/12/06 1633 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.02 +/-6.39 5.18 +/-6.40 10.6 pCi/g MXPI 08/11/06 0738 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.139 +/-0.213 0.173 +/-0.213 0.360 pCi/g EGDI 08/11/06 2027 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu- 11-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified Page 67 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-007F Project: YANK01204 Sample ID: 168404001 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA EERF C-01 Modified 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 80 (15%-125%)
Plutonium-242 Alphaspec Pu, Solid-ALL FSS 100 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 98 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 75 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 76 (25%-0125%)
Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 74 (15%/o-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 68 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-01IF Project: YANKO 1204 Sample ID: 168404002 Client ID: YANK001 Matrix: SE Vol. Recv.:
Collect Date: 19-MAY-06 Receive Date: 02-JUN-06 Collector: Client Moisture: 17.4%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.120 +/-0.154 0.0683 +/-0.155 0.251 pCi/g BXL1 08/11/06 1336 555696 1 Curium-242 U -0.0146 +/-0.122 0.0692 +/-0.123 0.303 pCi/g Curium-243/244 U -0.0103 +/-0.0861 0.0487 +/-0.0862 0.213 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.0121 +/-0.125 0.127 +/-0.125 0.344 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U 0.0254 +/-0.0675 0.0381 +/-0.0675 0.167 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 6.72 +/-7.02 5.56 +/-7.05 11.7 pCi/g BXLI 08/16/06 1237 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U -0.521 +/-7.03 5.94 +/-7.03 12.8 pCi/g DFAI 08/09/06 1143 554582 4 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.023 +/-0.0828 0.0685 +/-0.0828 0.143 pCi/g ATH2 08/09/06 0426 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 3.93 +/-47.7 31.9 +/-47.7 65.7 pCi/g MXPI 08/12/06 1649 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.52 +/-5.81 4.68 +/-5.81 9.60 pCi/g MXP1 08/11/06 0825 555723 7 Liquid Scint Tc99, Solid ALL FSS Technetium-99 U 0.173 +/-0.203 0.164 +/-0.203 0.341 pCi/g EGD1 08/11/06 2043 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I 1-RC Modified 3 DOE EML HASL-300, Pu-lI1-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 69 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0002-01 IF Project: YANK01204 Sample ID: 168404002 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 76 (15%-125%/o)
Plutonium-242 Alphaspec Pu, Solid-ALL FSS 100 (15%-1125%)
Carrier/Tracer Recovery Liquid Scint Pu24I, Solid-ALL Fý 88 (25%- 125%)
Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 72 (15%-/125%)
Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 76 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 79 (15%-/125%)
Notes:
The Qualifiers in this report are defined as follows:
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 70 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address: 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-004F Proiect: YANKO 1204 Sample ID: 168404003 Client ID: YANK001 Matrix: SE Vol. Recv.:
Collect Date: 25-APR-06 Receive Date: 05-MAY-06 Collector: Client Moisture: 23.5%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.027 +/-0.117 0.153 +/-0.117 0.488 pCi/g BXLI 08/13/06 0819 555696 1 Curium-242 U 0.112 +1-0.315 0.245 +/-0.315 0.781 pCi/g Curium-243/244 U 0.0217 +/-0.206 0.205 +/-0.206 0.594 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium- 2 38 U 0.061 +/-0.189 0.176 +/-0.189 0.449 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U 0.0551 +/-0.103 0.0584 +/-0.103 0.215 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 8.31 +/-5.73 4.40 +/-5.78 9.25 pCi/g BXLI 08/16/06 1253 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U -0.00343 +/-0.0203 0.0172 +/-0.0203 0.036 pCi/g BXFI 08/14/06 0834 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.603 +/-8.25 6.87 +/-8.25 14.8 pCi/g DFA I 08/09/06 1159 554582 5 Liquid Scint C4, Solid AllFSS Carbon-14 U 0.0937 +/-0.0813 0.0642 +/-0.0813 0.134 pCi/g ATH2 08/09/06 0529 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 7.68 +/-51.2 34.2 +/-51.2 70.4 pCi/g MXPI 08/12/06 1706 555722 7 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 5.74 +/-7.12 6.58 +/-7.13 13.6 pCi/g MXPI 08/11/06 0912 555723 8 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.0643 +/-0.198 0.169 +/-0.198 0.351 pCi/g EGD1 08/11/06 2059 554580 9 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified Page 71 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21,2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-004F Project: YANK01204 Sample ID: 168404003 Client ID: YANKOOI Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 3 DOE EML HASL-300. Pu-I I-RC Modified 4 EPA 905.0 Modified 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE RESL Ni-I, Modified 9 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 42 (15%- 125%)
Plutonium-242 Alphaspec Pu, Solid-ALL FSS 92 (15%- 125%)
Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 113 (250/-125%)
Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 59 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 71 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 83 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 76 (15%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded Page 72 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-004F Project: YANKO 1204 Sample ID: 168404003 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd The above sample is reported on a dry weight basis.
Page 73 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-015F Proiect: YANKO 1204 Sample ID: 168404004 Client ID: YANKOOI Matrix: SE Vol. Recv.:
Collect Date: 25-APR-06 Receive Date: 05-MAY-06 Collector: Client Moisture: 22.5%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0456 +1-0.155 0.139 +1-0.155 0.387 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U 0.113 +/-0.181 0.0733 +/-0.182 0.321 pCi/g Curium-243/244 U 0.180 +/-0.239 0.181 +/-0.240 0.472 pCi/g Alphaspec Pu, Solid-ALL FSS +/-0.121 +/-0.121 Plutonium-238 U 0.0196 0.118 0.324 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U 0.0326 +/-0.0639 0.00 +/-0.064 0.0884 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 6.63 +/-6.19 4.86 +/-6.22 10.2 pCi/g BXLI 08/16/06 1309 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr9o, solid-ALL FSS Strontium-90 U 0.00477 +/-0.0216 0.0179 +/-0.0216 0.0375 pCi/g BXF1 08/14/06 0834 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 1.03 +/-7.06 5.85 +/-7.06 12.6 pCi/g DFAI 08/09/06 1215 554582 5 Liquid Scint Cl4, SolidAllFSS Carbon-14 0.156 +/-0.0912 0.0699 +/-0.0913 0.146 pCi/g ATH2 08/09/06 0632 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -9.99 +/-42.7 28.7 +/-42.7 59.2 pCi/g MXPI 08/12/06 1722 555722 7 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 0.939 +/-10.1 10.3 +/-10.1 21.6 pCi/g MXPI 08/11/06 1001 555723 8 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.237 +/-0.213 0.170 +/-0.213 0.353 pCi/g EGD1 08/11/06 2115 554580 9 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I 1-RC Modified Page 74 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-015F Project: YANK01204 Sample ID: 168404004 Client ID: YANKOOI Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 905.0 Modified 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-1, Modified 8 DOE RESL Ni-I, Modified 9 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am24l, Cm, Solid ALL 78 (15%-125%)
Plutonium-242 Alphaspec Pu, Solid-ALL FSS 94 (15%-/125%)
Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 101 (25%-/125%)
Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 58 (25%6-125%)
Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 75 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 62 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%- 125%)
Notes:
The Qualifiers in this report are defined as follows:
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
Ul Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded Page 75 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0003-015F Project: YANKO 1204 Sample ID: 168404004 Client ID: YANKOO I Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd The above sample is reported on a dry weight basis.
Page 76 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005F Proiect: YANKO 1204 Sample ID: 168404005 Client ID: YANKOOI Matrix: SE Vol. Recv.:
Collect Date: 03-MAY-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 15.4%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.036 +/-0.123 0.157 +/-0.123 0.437 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U -0.0169 +/-0.033 0.080 +/-0.0331 0.350 pCi/g Curium-243/244 U -0.0129 +/-0.227 0.247 +/-0.227 0.619 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.0217 +/-0.163 0.181 +/-0.163 0.444 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U -0.0708 +/-0.0791 0.128 +/-0.0795 0.337 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 9.52 +/-6.00 4.57 +/-6.07 9.61 pCi/g BXL1 08/16/06 1326 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.854 +/-5.88 4.87 +/-5.88 10.5 pCi/g DFAI 08/09/06 1231 554582 4 Liquid Scint C14, SolidAllFSS Carbon-14 0.347 +/-0.097 0.0674 +/-0.0972 0.141 pCi/g ATH2 08/09/06 0734 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -1.57 +/-46.0 30.7 +/-46.0 63.2 pCi/g MXPI 08/12/06 1738 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 6.39 +/-7.62 7.40 +/-7.62 15.5 pCi/g MXPI 08/11/06 1017 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0198 +/-0.187 0.156 +/-0.187 0.324 pCi/g EGDI 08/11/06 2131 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu- I -RC Modified 3 DOE EML HASL-300, Pu-I l-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 77 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-005F Project: YANKO 1204 Sample ID: 168404005 Client ID: YANKOO Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-l, Modified 7 DOE RESL Ni-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 65 (15%-125%)
Plutonium-242 Alphaspec Pu, Solid-ALL FSS 95 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL F5 105 (25%- 125%)
Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 78 (15%-0125%)
Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 80 (25%- 125%)
Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 80 (15%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 78 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-015F Project: YANKO 1204 Sample ID: 168404006 Client ID: YANK001 Matrix: SE Vol. Recv.:
Collect Date: 03-MAY-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 26.5%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0823 +/-0.203 0.178 +/-0.203 0.469 pCi/g BXL1 08/11/06 1434 555696 1 Curium-242 U -0.0154 +/-0.0301 0.0729 +/-0.0302 0.319 pCi/g Curium-243/244 U -0.0994 +/-0.251 0.300 +/-0.251 0.713 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.0466 +/-0.213 0.210 +/-0.213 0.521 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U -0.142 +/-0.108 0.191 +/-0.109 0.483 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 6.64 +/-6.53 5.16 +/-6.57 10.8 pCi/g BXLI 08/16/06 1342 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U -2.9 +/-7.59 6.60 +/-7.59 14.2 pCi/g DFAI 08/09/06 1247 554582 4 Liquid Scint C14, Solid AIlFSS Carbon-14 U 0.0352 +/-0.0868 0.0713 +/-0.0868 0.149 pCi/g ATH2 08/09/06 0837 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 1.88 +/-46.8 31.3 +/-46.8 64.4 pCi/g MXPI 08/12/06 1754 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 3.88 +/-7.46 7.40 +/-7.46 15.5 pCi/g MXPI 08/11/06 1033 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0894 +/-0.198 0.163 +/-0.198 0.338 pCi/g EGD1 08/11/06 2147 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I 1-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-0I Modified Page 79 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0004-015F Project: YANK0 1204 Sample ID: 168404006 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 72 (15°/-125%)
Plutonium-242 Alphaspec Pu, Solid-ALL FSS 72 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 94 (25%-/125%)
Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 73 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 80 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 78 (150/-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UT Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 80 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-01OF Project: YANKO 1204 Sample ID: 168404007 Client ID: YANK001 Matrix: SE Vol. Recv.:
Collect Date: 02-MAY-06 Receive Date: 09-MAY-06 Collector: Client Moisture: 56.2%
Parameter Qualifier R Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U - +/-0.0939 0.142 +/-0.0942 0.385 pCi/g BXL1 08/11/06 1434 555696 1 Curium-242 U -0 +/-0.128 0.147 +/-0.128 0.450 pCi/g Curium-243/244 U -0 +/-0.122 0.149 +/-0.122 0.401 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0 +/-0.169 0.158 +/-0.170 0.403 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U 0 +/-0.121 0.117 +/-0.121 0.322 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 10.4 +/-6.89 5.27 +/-6.97 11.1 pCi/g BXLI 08/16/06 1358 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.00 +/-6.86 5.76 +/-6.86 12.4 pCi/g DFAl 08/09/06 1303 554582 4 Liquid Scint C14, SolidAllFSS Carbon- 14 U 0 .0636 +/-0.0801 0.0644 +/-0.0801 0.135 pCi/g ATH2 08/09/06 1017 554583 5 Liquid Scint Fe55, Solid-ALL FSS lron-55 U 36.1 +/-44.1 28.7 +/-44.1 59.0 pCi/g MXPI 08/12/06 1811 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.26 +/-10.2 10.0 +/-10.2 20.9 pCi/g MXPI 08/11/06 1049 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U --0.05 +/-0.199 0.169 +/-0.199 0.351 pCi/g EGD1 08/11/06 2203 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I 1-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 81 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-010F Project: YANK01204 Sample ID: 168404007 Client ID: YANKOO Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-I, Modified 7 DOE RESL Ni-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 85 (15%-1250%)
Plutonium-242 Alphaspec Pu, Solid-ALL FSS 91 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 92 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 81 (15%/-,125%)
Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 64 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Tc99,. Solid-ALL FS 77 (15%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 82 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-014F Proiect: YANK01204 Sample ID: 168404008 Client ID: YANK001 Matrix: SE Vol. Recv.:
Collect Date: 02-MAY-06 Receive Date: 09-MAY-06 Collector: Client Moisture: 32.3%
Parameter Qualifier Resuit Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0(0591 +/-0.219 0.231 +/-0.219 0.608 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U - 0.04 +1-0.0554 0.134 +/-0.0557 0.494 pCi/g Curium-243/244 U 0.(0634 +/-0.261 0.249 +/-0.261 0.646 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.t 0694 +/-0.106 0.160 +/-0.106 0.434 pCi/g BXL1 08/11/06 1633 555697 2 Plutonium-239/240 U -0.( 0287 +/-0.098 0.127 +/-0.0981 0.369 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 4.68 +/-8.01 6.48 +/-8.02 13.6 pCi/g BXLI 08/16/06 1415 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 6.02 +/-6.38 4.90 +/-6.38 10.6 pCi/g DFA1 08/09/06 1319 554582 4 Liquid Scint C14, SolidAllFSS Carbon-14 U 0.()892 +/-0.0827 0.0655 +/-0.0827 0.137 pCi/g ATH2 08/09/06 1424 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 19.8 +/-46.3 30.6 +/-46.3 62.9 pCi/g MXP] 08/12/06 1827 555722 6 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 5.41 +/-7.91 7.77 +/-7.91 16.2 pCi/g MXP1 08/11/06 1106 555723 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0 .134 +/-0.192 0.167 +/-0.192 0.346 pCi/g EGDl 08/11/06 2218 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-11-RC Modified 3 DOE EML HASL-300, Pu- 11-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified Page 83 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0005-014F Project: YANKO 1204 Sample ID: 168404008 Client ID: YANKOO Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 DOE RESL Fe-1, Modified 7 DOE RESL Ni-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 50 (15%-I125%)
Plutonium-242 Alphaspec Pu, Solid-ALL FSS 61 (15 %-125%)
Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 74 (25/6- 125%)
Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 76 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 76 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-,125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 84 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005F Project: YANKO 1204 Sample ID: 168404009 Client ID: YANKOO Matrix: SE Vol. Recv.:
Collect Date: 28-APR-06 Receive Date: 12-MAY-06 Collector: Client Moisture: 16.5%
Parameter Qualifier Re suit Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.(0851 +/-0.136 0.106 +/-0.136 0.390 pCi/g BXLI 08/16/06 0949 557837 1 Curium-242 U -0.( 0253 +/-0.0495 0.120 +/-0.0496 0.525 pCi/g Curium-243/244 U -0.( 0479 +/-0.0542 0.131 +/-0.0545 0.443 pCi/g Aiphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.(0183 +/-0.113 0.110 +/-0.113 0.303 pCi/g BXLI 08/11/06 1633 555697 3 Plutonium-239/240 U 0.0(0122 +/-0.0662 0.0694 +/-0.0662 0.221 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 4.43 +/-5.83 4.67 +/-5.85 9.82 pCi/g BXL1 08/16/06 1431 555698 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U - 2.02 +/-6.67 5.76 +/-6.67 12.4 pCi/g DFAI 08/09/06 1335 554582 5 Liquid Scint C14, SolidAllFSS Carbon-14 0.142 +/-0.0798 0.061 +/-0.0799 0.127 pCi/g ATH2 08/09/06 1719 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 12.6 +/-47.6 31.7 +/-47.6 65.3 pCi/g MXPI 08/12/06 1843 555722 7 Liquid Scint Ni63, Solid-ALL FSS Nickel-63 U 7.70 +/-9.56 9.31 +/-9.56 19.5 pCi/g MXP1 08/11/06 1122 555723 8 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U -0.00 )659 +/-0.185 0.156 +/-0.185 0.323 pCi/g EGD1 08/11/06 2234 554580 9 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Am-05-RC Modified 3 DOE EML HASL-300, Pu- I -RC Modified 4 DOE EML HASL-300, Pu-1 I-RC Modified 5 EPA 906.0 Modified Page 85 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0006-005F Project: YANK01204 Sample ID: 168404009 Client ID: YANKOO I Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 6 EPA EERF C-01 Modified 7 DOE RESL Fe-1, Modified 8 DOE RESL Ni-I, Modified 9 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 76 (15%-125%)
Plutonium-242 Alphaspec Pu, Solid-ALL FSS 93 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 105 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 72 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Ni63, Solid-ALL FS 64 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 81 (15%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 86 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0008-006F Proiect: YANKO 1204 Sample ID: 168404010 Client ID: YANKOOI Matrix: SE Vol. Recv.:
Collect Date: 05-MAY-06 Receive Date: 26-MAY-06 Collector: Client Moisture: 34.8%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U I +/-0.195 0.0758 +/-0.196 0.332 pCi/g BXLI 08/16/06 0949 557837 1 Curium-242 U I +/-0.202 0.00 +/-0.203 0.280 pCi/g Curium-243/244 U -0. +/-0.0316 0.0766 +/-0.0317 0.335 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0. +/-0.0711 0.0967 +/-0.0712 0.275 pCi/g BXLI 08/11/06 1633 555697 3 Plutonium-239/240 U 0.0 +/-0.113 0.118 +/-0.113 0.317 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 14.9 +/-6.37 4.64 +/-6.51 9.75 pCi/g BXLI 08/16/06 1447 555698 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.00 +/-6.06 5.09 +/-6.06 10.7 pCi/g DFAI 08/10/06 2150 554582 5 LiquidScint C14, SolidAllFSS Carbon- 14 U ).107 +/-0.0846 0.0664 +/-0.0846 0.139 pCi/g ATH2 08/09/06 1822 554583 6 Liquid Scint Fe55, Solid-ALL FSS lron-55 U 15.1 +/-41.4 27.5 +/-41.4 56.6 pCi/g MXPI 08/12/06 1900 555722 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U ).258 +/-0.225 0.179 +/-0.225 0.373 pCi/g EGDI 08/11/062251 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were. performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Am-05-RC Modified 3 DOE EML HASL-300, Pu- 11-RC Modified 4 DOE EML HASL-300, Pu-11-RC Modified 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified Page 87 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0008-006F Project: YANK01204 Sample ID: 168404010 Client ID: YANKOOI Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 77 (15%-125%o)
Plutonium-242 Alphaspec Pu, Solid-ALL FSS 94 (159/6-125%)
Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL Fý 103 (25%-I125%)
Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 72 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 71 (15%-I125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 88 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0008-008F Proiect: YANKO 1204 Sample ID: 168404011 Client ID: YANKOO Matrix: SE Vol. Recv.:
Collect Date: 08-MAY-06 Receive Date: 26-MAY-06 Collector: Client Moisture: 35.7%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0. 0969 +/-0.192 0.152 +/-0.193 0.426 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U -0. 0482 +/-0.142 0.132 +/-0.142 0.446 pCi/g Curium-243/244 U -0. 0576 +/-0.202 0.240 +/-0.203 0.603 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0. 0397 +/-0.096 0.125 +/-0.096 0.328 pCi/g BXLI 08/11/06 1633 555697 2 Plutonium-239/240 U -0. 0315 +/-0.114 0.137 +/-0.114 0.353 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 11.5 +/-6.72 5.08 +/-6.80 10.7 pCi/g BXLI 08/16/06 1504 555698 3 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.00 +/-5.92 4.97 +/-5.92 10.7 pCi/g DFAI 08/09/06 1407 554582 4 Liquid Scint C14, SolidAllFSS Carbon-14 U -0.0238 +/-0.0745 0.0636 +/-0.0745 0.133 pCi/g ATH2 08/09/06 1924 554583 5 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -10.7 +/-40.9 27.5 +/-40.9 56.8 pCi/g MXP1 08/12/06 1916 555722 6 LiquidScint Tc99, Solid-ALL FSS Technetium-99 U 0.0956 +/-0.211 0.174 +/-0.211 0.361 pCi/g EGDI 08/11/06 2307 554580 7 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 906.0 Modified 5 EPA EERF C-01 Modified 6 DOE RESL Fe-I, Modified Page 89 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0008-008F Project: YANKO 1204 Sample ID: 168404011 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 7 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 65 (15%-125%)
Plutonium-242 Alphaspec Pu, Solid-ALL FSS 98 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 96 (259/6-125%)
Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 76 (15%-/125%)
Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 74 (15%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 90 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21,2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-002F Proiect: YANKO 1204 Sample ID: 168404012 Client ID: YANKOO Matrix: SE Vol. Recv.:
Collect Date: 11-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 33%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U -0.00144 +1-0.155 0.166 +1-0.155 0.458 pCi/g BXL1 08/11/06 1434 555696 1 Curium-242 U 0.0192 +/-0.145 0.135 +/-0.145 0.455 pCi/g Curium-243/244 U 0.013 +/-0.268 0.281 +/-0.268 0.687 pCi/g Alphaspec Pu, Solid-ALL FSS 0.0279 Plutonium-238 U -0.00587 +/-0.0493 +/-0.0494 0.122 pCi/g BXL1 08/11/06 1632 555697 2 Plutonium-239/240 U 0.0186 +/-0.0492 0.0278 +/-0.0493 0.122 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.6 +/-6.90 5.13 +/-7.01 10.8 pCi/g BXLI 08/16/06 1520 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr9O, solid-ALL FSS Strontium-90 U 0.0151 +/-0.0146 0.0114 +/-0.0146 0.0242 pCi/g BXFI 08/14/06 0834 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 4.12 +/-8.36 6.70 +/-8.36 14.5 pCi/g DFAI 08/09/06 1422 554582 5 Liquid Scint C14, SolidAllFSS Carbon- 14 U 0.046 +/-0.0755 0.0613 +/-0.0755 0.128 pCi/g ATH2 08/09/06 2027 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U 12.9 +/-40.6 26.8 +/-40.6 55.2 pCi/g MXPI 08/12/06 1932 555722 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.078 +/-0.203 0.168 +/-0.203 0.348 pCi/g EGD1 08/11/06 2323 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 905.0 Modified Page 91 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-002F Project: YANK01204 Sample ID: 168404012 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 61 (15%-125%)
Plutonium-242 Alphaspec Pu, Solid-ALL FSS 98 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Pu24 1,Solid-ALL FS 94 (25%- 125%)
Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 69 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 81 (15%-/125%)
Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-/125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 92 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.corn Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-017F Project: YANK01204 Sample ID: 168404013 Client ID: YANKOO I Matrix: SE Vol. Recv.:
Collect Date: 15-MAY-06 Receive Date: 08-JUN-06 Collector: Client Moisture: 28.4%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.0755 +/-0.242 0.230 +/-0.243 0.574 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U 0.0957 +/-0.220 0.171 +/-0.220 0.509 pCi/g Curium-243/244 U -0.073 +/-0.214 0.256 +/-0.214 0.627 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00629 +/-0.0529 0.0299 +/-0.0529 0.131 pCi/g BXLI 08/11/06 1632 555697 2 Plutonium-239/240 U 0.0262 +/-0.0513 0.00 +/-0.0514 0.0709 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.3 +/-6.66 4.95 +/-6.77 10.4 pCi/g BXLI 08/16/06 1536 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U 0.0205 +/-0.0151 0.0116 +/-0.0151 0.0246 pCi/g BXFI 08/14/06 0833 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.583 +/-7.98 6.65 +/-7.98 14.4 pCi/g DFAI 08/09/06 1438 554582 5 Liquid Scint C14, SolidAll,FSS Carbon-14 U 0.0271 +/-0.0759 0.0625 +/-0.0759 0.131 pCi/g ATH2 08/09/06 2129 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U -61.9 +/-150 102 +/-150 210 pCi/g MXPI 08/12/06 1949 555722 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0628 +/-0.200 0.165 +/-0.200 0.343 pCi/g EGDI 08/11/06 2338 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description 1 DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 905.0 Modified Page 93 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0009-017F Project: YANK01204 Sample ID: 168404013 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-1, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 64 (15%o-125%o)
Plutonium-242 Alphaspec Pu, Solid-ALL FSS 91 (15%/.-125%)
Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL FS 96 (25%- 125%)
Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 72 (25%- 125%)
Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 73 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 79 (15%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 94 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-00IF Proiect: YANKO 1204 Sample ID: 168404014 Client ID: YANK001 Matrix: SE Vol. Recv.:
Collect Date: 04-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 27.3%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.00677 +/-0.227 0.238 +/-0.227 0.628 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U 0.0854 +/-0.167 0.00 +/-0.168 0.231 pCi/g Curium-243/244 U 0.0361 +/-0.242 0.241 +/-0.242 0.634 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U 0.173 +/-0.181 0.143 +/-0.182 0.331 pCi/g BXL1 08/11/06 2250 555697 2 Plutonium-239/240 U --0.0342 +/-0.0865 0.0951 +/-0.0866 0.235 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 13.0 +/-6.44 4.78 +/-6.54 10.0 pCi/g BXLI 08/16/06 1553 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U --0.0128 +/-0.0141 0.0125 +/-0.0141 0.0262 pCi/g BXFI 08/14/06 0833 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 01.548 +/-7.50 6.25 +/-7.50 13.5 pCi/g DFA1 08/09/06 1454 554582 5 Liquid Scint C14, SolidAllFSS Carbon- 14 U 0.'0555 +/-0.0809 0.0655 +/-0.0809 0.137 pCi/g ATH2 08/09/06 2232 554583 6 Liquid Scint Fe55, Solid-ALL FSS Iron-55 U - 18.1 +/-47.6 32.3 +/-47.6 66.6 pCi/g MXPI 08/12/06 2005 555722 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.134 +/-0.205 0.167 +/-0.205 0.347 pCi/g EGDI 08/11/06 2354 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I I-RC Modified 4 EPA 905.0 Modified Page 95 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-00IF Project: YANKO 1204 Sample ID: 168404014 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified 7 DOE RESL Fe-1, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 50 (15%-125%)
Plutonium-242 Alphaspec Pu, Solid-ALL FSS 85 (15%6-125%)
Carrier/Tracer Recovery Liquid Scint Pu24 1, Solid-ALL F5 99 (25%-/125%)
Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 74 (25%-/125%)
Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 70 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 (15%-125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 96 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-012F Project: YANK01204 Sample ID: 168404015 Client ID: YANK001 Matrix: SE Vol. Recv.:
Collect Date: 04-MAY-06 Receive Date: 17-MAY-06 Collector: Client Moisture: 28.1%
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium-241 U 0.110 +/-0.184 0.140 +/-0.184 0.386 pCi/g BXLI 08/11/06 1434 555696 1 Curium-242 U -0.0547 +/-0.141 0.192 +/-0.141 0.544 pCi/g Curium-243/244 U -0.126 +/-0.184 0.245 +/-0.185 0.597 pCi/g Alphaspec Pu, Solid-ALL FSS Plutonium-238 U -0.00157 +/-0.126 0.122 +/-0.126 0.291 pCi/g BXLI 08/11/06 2250 555697 2 Plutonium-239/240 U 0.0867 +/-0.0869 0.0406 +/-0.0872 0.128 pCi/g Liquid Scint Pu241, Solid-ALL FSS Plutonium-241 U 8.31 +/-6.16 4.77 +/-6.21 10.0 pCi/g BXLI 08/16/06 1609 555698 3 Rad Gas Flow Proportional Counting GFPC,Sr90, solid-ALL FSS Strontium-90 U -0.00771 +/-0.0144 0.0124 +/-0.0144 0.0263 pCi/g BXF1 08/14/06 0833 556350 4 Rad Liquid Scintillation Analysis LSC, Tritium Dist, Solid-HTD2,ALL FSS Tritium U 0.896 +/-6.17 5.11 +/-6.17 11.0 pCi/g DFAI 08/09/06 1510 554582 5 Liquid Scint C14, SolidAll,FSS Carbon-14 U 0.0162 +/-0.0763 0.0633 +/-0.0763 0.132 pCi/g ATH2 08/09/06 2334 554583 6 Liquid Scint Fe55, Solid-ALL FSS lron-55 U 23.3 +/-49.3 32.5 +/-49.3 67.0 pCi/g MXPI 08/12/06 2021 555722 7 Liquid Scint Tc99, Solid-ALL FSS Technetium-99 U 0.0577 +/-0.206 0.171 +/-0.206 0.354 pCi/g EGDI 08/12/06 0010 554580 8 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GL-RAD-A-021 LXM2 08/03/06 1534 554649 The following Analytical Methods were performed Method Description I DOE EML HASL-300, Am-05-RC Modified 2 DOE EML HASL-300, Pu-I I-RC Modified 3 DOE EML HASL-300, Pu-I 1-RC Modified 4 EPA 905.0 Modified Page 97 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Company: Connecticut Yankee Atomic Power Address : 362 Injun Hollow Rd East Hampton, Connecticut 06424 Report Date: August 21, 2006
Contact:
Mr. Jack McCarthy Project: Soils PO# 002332 Client Sample ID: 9106-0010-012F Project: YANK01204 Sample ID: 168404015 Client ID: YANK001 Vol. Recv.:
Parameter Qualifier Result Uncertainty LC TPU MDA Units DF Analyst Date Time Batch Mtd 5 EPA 906.0 Modified 6 EPA EERF C-01 Modified' 7 DOE RESL Fe-I, Modified 8 DOE EML HASL-300, Tc-02-RC Modified Surrogate/Tracer recovery Recovery% Acceptable Limits Americium-243 Alphaspec Am241, Cm, Solid ALL 81 (15%-I125%)
Plutonium-242 Alphaspec Pu, Solid-ALL FSS 91 (15°/o-125%)
Carrier/Tracer Recovery Liquid Scint Pu241, Solid-ALL F5 99 (25%-/125%)
Carrier/Tracer Recovery GFPC, Sr90, solid-ALL FSS 68 (25%-125%)
Carrier/Tracer Recovery Liquid Scint Fe55, Solid-ALL FS 74 (15%-125%)
Carrier/Tracer Recovery Liquid Scint Tc99, Solid-ALL FS 75 ( 15°/o- 125%)
Notes:
The Qualifiers in this report are defined as follows
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported
> Result is greater than value reported A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded The above sample is reported on a dry weight basis.
Page 98 of 105
.I QUALITY CONTROL DATA Page 99 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Report Date: August 21, 2006 Client : Connecticut Yankee Atomic Power Page 1 of 6 362 Injun Hollow Rd East Hampton, Connecticut
Contact:
Mr. Jack McCarthy Workorder: 168404 Parmname NOM Samnle Oual OC Units RPD% REC% Ranee Anist Date Time Rad Alpha Spec Batch 555696 QC1201153130 168340011 DUP Americium-241 U -0.000522 U 0.0578 pCi/g 204 (0% - 100%) BXLI 08/11/06 14:34 Uncert: +/-0.0385 +/-0.278 TPU: +/-0.0385 +/-0.279 Curium-242 U 0.00 U -0.0405 pCi/g 200 (0%- 100%)
Uncert: +/-0.0756 +/-0.0562 TPU: +/-0.0756 +/-0.0565 Curium-243/244 U -0.0177 U -0.0517 pCi/g 98 (0%- 100%)
Uncert: +/-0.0764 +/-0.257 TPU: +/-0.0765 +/-0.257 QC1201153132 LCS Americium-241 12.8 12.8 pCi/g 100 (75%-125%)
Uncert: +/- 1.84 TPU: +/-2.70 Curium-242 U -0.0328 pCi/g Uncert: +/-0.0454 TPU: +/-0.0457 Curium-243/244 15.5 14.3 pCi/g 92 (75%-125%)
Uncert: +/-1.94 TPU: +/-2.92 QC1201153129 MB Americium-241 U 0.0471 pCi/g Uncert: +/-0.157 TPU: +/-0.157 Curium-242 U -0.0469 pCi/g Uncert: +/-0.0459 TPU: +/-0.0464 Curium-243/244 U -0.00385 pCi/g Uncert: +/-0.210 TPU: +/-0.210 QC1201153131 168340011 MS Americium-24 l 13.3 U -0.000522 12.0 pCi/g 91 (75%-125%)
Uncert: +/-0.0385 +/-1.38 TPU: +/-0.0385 +/-2.08 Curium-242 U 0.00 U 0.0427 pCi/g Uncert: +/-0.0756 +/-0.0837 TPU: +/-0.0756 +/-0.0839 Curium-243/244 16.1 U -0.0177 15.9 pCi/g 99 (75%-125%)
Uncert: +/-0.0764 +/-1.58 TPU: +/-0.0765 +/-2.61 Batch 555697 QC1201153134 168340011 DUP Plutonium-238 U -0.0155 U 0.0237 pCi/g 956 (0% - 100%) BXLI 08/11/06 22:51 Page 100 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 168404 Page 2 of 6 Parmname NOM Sample Oual OC Units RPD% REC% Ran2e Anist Date Time Rad Alpha Spec Batch 555697 Uncert: +/-0.0215 +/-0.0465 TPU: +/-0.0216 +/-0.0466 Plutonium-239/240 U 0.0414 U -0.0489 pCi/g 2410 (0%- 100%)
Uncert: +/-0.0934 +/-0.124 TPU: +/-0.0935 +/-0.124 QC1201153136 LCS Plutonium-238 U 0.155 pCi/g (75%-125%)
Uncert: +/-0.141 TPU: +/-0.142 Plutonium-239/240 11.8 11.5 pCi/g 98 (75%-125%)
Uncert: +/-0.856 TPU: +/-1.32 QC1201153133 MB Plutonium-238 U 0.0552 pCi/g 08/11/06 22:50 Uncert: +/-0.186 TPU: +/-0.186 Plutonium-239/240 U -0.0978 pCi/g Uncert: +/-0.0892 TPU: +/-0.0899 QC1201153135 168340011 MS Plutonium-238 u -0.0155 U 0.0539 pCi/g (75%-I 25%) 08/11/06 22:51 Uncert: +/-0.0215 +/-0.112 TPU: +/-0.0216 +/-0.112 Plutonium-239/240 12.3 U 0.0414 10.3 pCi/g 84 (75%-125%)
Uncert: +/-0.0934 +/-0.796 TPU: +/-0.0935 +/-1.19 Batch 555698 QC1201153138 168340011 DUP Plutonium-241 U 7.28 U 10.1 pCi/g 0 (0% - 100%) BXLI 08/16/06 16:41 Uncert: +/-6.30 +/-6.39 TPU: +/-6.35 +/-6.46 QC1201153140 LCS Plutonium-241 137 145 pCilg 106 (75%-125%) 08/16/06 17:14 Uncert: +/-12.5 TPU: +/-19.9 QC1201153137 MB Plutonium-241 U 8.57 pCi/g 08/16/06 16:25 Uncert: +/-6.93 TPU: +/-6.98 QC1201153139 168340011 MS Plutonium-241 138 U 7.28 142 pCi/g 103 (75%-125%) 08/16/06 16:58 Uncert: +/-6.30 +/- 12.4 TPU: +/-6.35 +/-19.7 Batch 557837 I QC1201158317 168404009 DUP Americium-241 U -0.0851 U 0.167 pCi/g 616 (0%- 100%) BXLI 08/16/06 09:49 Uncert: +/-0.136 +/-0.220 TPU: +/-0.136 +/-0.221 Curium-242 U -0.0253 U 0.241 pCi/g 247 (0%- 100%)
Page 101 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 168404 Page 3 of 6 Parmname NOM Sample Qua] QC Units RPD% REC% Range Anist Date Time Rad Alpha Spec Batch 557837 Uncert: +/-0.0495 +/-0.334 TPU: +/-0.0496 +/-0.335 Curium-243/244 U -0.0479 U 0.0761 pCi/g 879 (0%- 100%)
Uncert: +/-0.0542 +/-0.149 TPU: +/-0.0545 +/-0.149 QC1201158319 LCS Americium-241 24.5 25.4 pCi/g 104 (75%-125%)
Uncert: +/-2.47 TPU: +/-4.16 Curium-242 U 0.0477 pCi/g Uncert: +/-0.127 TPU: +/-0.127 Curium-243/244 29.7 27.0 pCi/g 91 (75%-125%)
Uncert: +/-2.54 TPU: +/-4.38 QC1201158316 MB Americium-241 U 0.234 pCi/g Uncert: +/-0.275 TPU: +/-0.277 Curium-242 U 0.00 pCi/g Uncert: +/-0.152 TPU: +/-0.152 Curium-243/244 U -0.0551 pCi/g Uncert: +/-0.0624 TPU: +/-0.0628 QC1201158318 168404009 MS Americium-241 26.4 U -0.0851 29.1 pCi/g 110 (75%-125%)
Uncert: +/-0.136 +/-2.97 TPU: +/-0.136 +1-5.01 Curium-242 U -0.0253 U 0.126 pCi/g Uncert: +/-0.0495 +/-0.247 TPU: +/-0.0496 +/-0.248 Curium-243/244 32.4 U -0.0479 31.7 pCi/g 98 (75%-125%)
Uncert: +/-0.0542 +/-3.12 TPU: +/-0.0545 +/-5.39 Rad Gas Flow Batch 556350 QC1201154645 168404003 DUP Strontium-90 U -0.00343 U -0.00637 pCi/g 0 (0% - 100%) BXFI 08/14/06 08:33 Uncert: +/-0.0203 +/-0.0152 TPU: +/-0.0203 +/-0.0152 QC1201154647 LCS Strontium-90 1.56 1.30 pCi/g 83 (75%-125%)
Uncert: +/-0.0563 TPU: +/-0.0881 QC1201154644 MB Strontium-90 U 0.0176 pCi/g Uncert: +/-0.018 TPU: +/-0.018 Page 102 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 168404 Page 4 of 6 Parmname NOM Sample Qual OC Units RPD% REC% Range Anist Date Time Rad Gas Flow Batch 556350 QC1201154646 168404003 MS Strontium-90 1.58 U -0.00343 1.29 pCi/g 82 (75%-125%)
Uncert: +/-0.0203 +/-0.0535 TPU: +/-0.0203 +/-0.0813 Rad Liquid Scintillation Batch 554580 QC1201150562 168340012 DUP Technetium-99 U 0.0338 U 0.266 pCi/g 0 (0% - 100%) EGDI 08/12/06 00:42 Uncert: +/-0.192 +/-0.226 TPU: +/-0.192 +/-0.226 QC1201150564 LCS Technetium-99 13.1 13.6 pCi/g 103 (75%-125%) 08/12/06 01:14 Uncert: +/-0.496 TPU: +/-0.599 QC1201150561 MB Technetium-99 U 0.0311 pCi/g 08/12/06 00:26 Uncert: +/-0.177 TPU: +/-0.177 QC1201150563 168340012 MS Technetium-99 13.0 U 0.0338 12.0 pCi/g 92 (75%-125%) 08/12/06 00:58 Uncert: +/-0.192 +/-0.523 TPU: +/-0.192 +/-0.602 Batch 554582 QC1201150570 168340011 DUP Tritium U 1.77 U 1.62 pCi/g 0 (0% - 100%) DFAI 08/09/06 15:42 Uncert: +/-8.20 +/-7.47 TPU: +/-8.20 +/-7.47 QC1201150572 LCS Tritium 68.3 76.2 pCi/g I11 (75%-125%) 08/09/06 16:14 Uncert: +/-14.0 TPU: +/-14.1 QC1201150569 MB Tritium U 0.586 pCi/g 08/09/06 15:26 Uncert: +/-8.01 TPU: +/-8.01 QC1201150571 168340011 MS Tritium 61.3 U 1.77 61.8 pCi/g 101 (75%-125%) 08/09/06 15:58 Uncert: +/-8.20 +/-12.2 TPU: +/-8.20 +/-12.3 Batch 554583 QC1201150574 168404003 DUP Carbon- 14 U 0.0937 U 0.0422 pCi/g 0 (0% - 100%) ATH2 08/10/06 01:39 Uncert: +/-0.0813 +/-0.075 TPU: +/-0.0813 +/-0.0751 QC1201150576 LCS Carbon-14 7.27 7.14 pCi/g 98 (75%-125%) 08/10/06 03:00 Uncert: +/-0.508 TPU: +/-0.520 QC1201150573 MB Page 103 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 168404 Page 5 of 6 Parmname NOM Sample Qual QC Units RPD% REC% Range AnIst Date Time Rad Liquid Scintillation Batch 554583 Carbon- 14 U -0.0315 pCi/g Uncert: +/-0.0776 TPU: +/-0.0776 QC1201150575 168404003 MS Carbon-14 15.1 U 0.0937 13.8 pCi/g 92 (75%-125%) 08/10/06 02:43 Uncert: +/-0.0813 +/-1.00 TPU: +/-0.0813 +/-1.03 Batch 555722 QC1201153223 168340012 DUP lron-55 U -26.5 U 5.83 pCi/g 0 (0% - 100%) vIXPI 08/12/06 20:54 Uncert: +/-65.1 +/-36.9 TPU: +/-65.1 +/-36.9 QC0201153225 LCS Iron-55 641 660 pCi/g 103 (75%-125%) 08/12/06 21:27 Uncert: +/-56.2 TPU: +/-67.2 QCI201153222 MB Iron-55 U 18.2 pCi/g 08/12/06 20:38 Uncert: +/-39.6 TPU: +/-39.6 QC1201153224 168340012 MS Iron-55 717 U -26.5 688 pCi/g 96 (75%-125%) 08/12/06 21:11 Uncert: +/-65.1 +/-60.2 TPU: +/-65.1 +/-71.6 Batch 555723 QC1201153227 168340012 DUP Nickel-63 U 3.79 U 6.68 pCi/g 0 (0% - 100%) viXPI 08/11/06 11:55 Uncerl: +/-5.39 +/-7.43 TPU: +/-5.40 +/-7.43 QC1201153229 LCS Nickel-63 512 479 pCi/g 94 (75%-125%) 08/1 1/06 12:27 Uncert: +/-22.4 TPU: +/-27.1 QC1201153226 MB Nickel-63 U 15.7 pCi/g 08/11/06 11:38 Uncert: +/-9.92 TPU: +/-9.93 QC1201153228 168340012 MS Nickel-63 530 U 3.79 511 pCi/g 96 (75%-125%) 08/11/06 12:11 Uncert: +/-5.39 +/-23.5 TPU: +/-5.40 +/-28.7 Notes:
The Qualifiers in this report are defined as follows:
- A quality control analyte recovery is outside of specified acceptance criteria
< Result is less than value reported Result is greater than value reported Page 104 of 105
GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 168404 Page 6 of 6 Parmname NOM Sample Qual QC Units RPD% REC% Range Anist Date Time A The TIC is a suspected aldol-condensation product B Target analyte was detected in the associated blank BD Results are either below the MDC or tracer recovery is low C Analyte has been confirmed by GC/MS analysis D Results are reported from a diluted aliquot of the sample H Analytical holding time was exceeded J Value is estimated N/A Spike recovery limits do not apply. Sample concentration exceeds spike concentration by 4X or more R Sample results are rejected U Analyte was analyzed for, but not detected above the MDL, MDA, or LOD.
UI Gamma Spectroscopy--Uncertain identification X Consult Case Narrative, Data Summary package, or Project Manager concerning this qualifier Y QC Samples were not spiked with this compound A RPD of sample and duplicate evaluated using +/-RL. Concentrations are <5X the RL h Preparation or preservation holding time was exceeded N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike cone. by a factor of 4 or more.
- Indicates analyte is a surrogate compound.
^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.
For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.
Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.
Page 105 of 105
DISCHARGE CANAL SURVEY UNIT 9106-0010 RELEASE RECORD Attachment 2b Split Sample Assessment Forms (2 Pages)
Connecticut Yankee Decommissioning Project Health 24265-000-GPR-GGGR-R5124-000 Attachment A Physics Procedure Split Sample Assessment Form Survey Area Survey 0010 Survey Discharge Canal
- 9106 Unit #: Unit Name:
Sample Plan or WPIR#: 2006-021 SML #: 9106-0010-011 Sample
Description:
Comparison of split samples collected from sample measurement location #11 and analyzed using gamma spectroscopy by an off-site vendor laboratory. The standard sample was 9106-0010-011 F the comparison sample was 9106-0010-011 FS.
STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)
Value Error Range Value Error Ratio Cs-137 3.45E-01 3.54E-02 10 0.6- 1.66 1.39E-01 1.57E-02 0.40 N Co-60 2.27E-01 3.74E-02 6 0.5- 2 1.32E-01 1.85E-02 0.58 Y Ni-63 6.33E+00 4.57E+00 1 NONE- -6.07E+00 2.36E+00 -0.96 N/A K-40 1.45E+01 5.45E-01 27 0.75 1.33 1.21E+01 5.25E-01 0.83 Y Comments/Corrective Actions: In consideration of the Ni-63 Table is provided to show acceptance criteria used results, guidance for agreement ranges, obtained from USNRC to assess split samples.
Inspection Procedure 84750, does not address resolution ratios less than 4, therefore, a determination of acceptability for such Resolution I Agreement Range rations cannot be made. Since Cs-137 has a likelyhood to be 4 7 0.50 2.00 tightly bound to organic mater in the sample matrix, one would 8 15 0.60 1.66 not neccassarily expect it to be homogenuously mixed if 16 50 0.75 1.33 processing of the sample-split aliqot is not effective in 51 200 0.80 1.25 dispersing organic material uniformly through the sample aliqot. Since both Co-60 and K-40 were also found to be > 200 0.85 1.18 present at an acceptable level of agreement, no further action is warranted.
Performed By: viewed b~y:
WPIR - Work Plan and Inspection Record SML - Sample Measurement Location designation Page I of I
Connecticut Yankee Decommissioning Project Health 24265-000-GPR-GGGR-R5124-000 Attachment A Physics Procedure Split Sample Assessment Form Survey SSurvey 0010 urvey Unit Discharge Canal Area#: Unit #: Name:
Sample Plan or WPIR#: 2006-0021 SML #: 9106-0010-014 Sample
Description:
Comparison of split samples collected from sample measurement location #18 and analyzed using gamma spectroscopy by an off-site vendor laboratory. The standard sample was 9106-0010-014F, the comparison sample was 9106-0010-014FS.
STANDARD COMPARISON Radionuclide Activity Standard Resolution Agreement Activity Standard Comparison Acceptable (Y/N)
Value Error Range Value Error Ratio Cs-137 8.57E-02 1.78E-02 5 0.5 - 2 6.59E-02 1.95E-02 0.77 Y Co-60 5.07E-02 1.33E-02 4 0.5- 2 0.OOE+00 1.70E-02 0.00 N Ni-63 -4.24E+00 1.86E+00 -2 NONE - -2.83E+00 2.24E+00 0.67 N/A K-40 1.19E+01 5.25E-01 23 0.75 1.33 1.29E+01 5.05E-01 1.08 Y
_ I __ _ i _ _ I _ I __ I _ _ I _ _ I __
I I I .4. 4 4 4 .4.
I I 4 .1. 4 4 4 +
I d I __________ I I Comments/Corrective Actions: In consideration of the I Table is provided to show acceptance criteria used results, guidance for agreement ranges, obtained from Uý to assess split samples.
Inspection Procedure 84750, does not address resolution -!t'l no I less than 4, therefore, a determination of acceptability foi Resolution Agreement Range rations cannot be made. Since Co-60 has a likelyhood to 4 7 0.50 2.00 present in the sample matrix in particulate form, one wou 8 15 0.60 1.66 not neccassarily expect it to be homogenuously mixed fr( 16 50 0.75 1.33 processing of the sample-split aliqot. Since both Cs-137 51 200 0.80 1.25 K-40 were also found to be present at an acceptable level
> 200 0.85 1.18 agreement, no further action is warranted.
Performed By:
WPIR - Work Plan and Inspection Record SML - Sample Measurement Location designation Page I of I
DISCHARGE CANAL SURVEY UNIT 9106-0010 RELEASE RECORD Attachment 2c Preliminary Data Form (1 Page)
Health Physics Procedure GPP-GGGR-R512 1-001 Attachment B, Rev. CY-00 I MAJOR Health Physics Procedure GPP-GGGR-R5121-001 Attachment B, Rev. CY-001 MAJOR Preliminary Data Review Form - Samples for the Sign Test Survey Unit: 9106- 0010 Survey Unit Name: Discharge Canal Classification: 2 Survey Media: Soil Type of Survey: Final Status Survey Type of Measurement: Gross Measurement Number of Measurements: 15 Operational DCGL: 1 BASIC STATISTICAL QUANTITIES Cs-137 Co-60 Ni-63 Minimum Value: 6.73E-03 -2.26E-03 -4.88E+00 Maximum Value: 3.45E-01 5.75E-01 6.33E+00 Mean: 1.17E-0 1 1.30E-01 -2.68E+00 Median: 8.57E-02 5.45E-02 -3.71E+00 Standard Deviation: 1.OIE-01 1.66E-01 2.75E+00 RADIONUCLIDE CONCENTRATION (pCi/g)
NUMBER Cs-137 Co-60 Ni-63 Identified? Identified? Identified?
9106-0010-OO1F 2.60E-01 5.75E-01 -1.07E+00 Y Y N 9106-0010-002F 2.78E-02 5.45E-02 -4.66E+00 Y Y N 9106-0010-003F 6.72E-02 -2.26E-03 -3.75E+00 Y N N 9106-0010-004F 4.92E-02 8.38E-02 -4.77E+00 Y Y N 9106-0010-005F 1.08E-02 -2.17E-05 -3.87E+00 N N N 9106-0010-006F 1.47E-01 1.82E-01 -2.58E+00 Y Y N 9106-0010-007F 8.OOE-02 8.30E-02 -2.34E+00 Y Y N 9106-0010-008F 2.20E-01 1.95E-02 -2.65E+00 Y N N 9106-0010-009F 1.30E-01 1.92E-01 -3.71 E+00 Y Y N 9106-0010-01OF 1.17E-01 5.08E-02 -3.80E+00 Y Y N 9106-0010-01 IF 3.45E-01 2.27E-01 6.33E+00 Y Y N 9106-0010-012F 1.94E-01 4.03E-01 -2.72E+00 Y Y N 9106-0010-013F 7.71 E-03 1.48E-03 -4.88E+00 N N N 9106-0010-014F 8.57E-02 5.07E-02 -4.24E+00 Y Y N 9106-0010-015F 6.73E-03 2.28E-02 -1.48E+00 N Y N Performed By: 5d-* y4* Date: ll-z-0 Independent Review: Date: A/'-d
DISCHARGE CANAL SURVEY UNIT 9106-0010 RELEASE RECORD Attachment 2d Graphical Representation of Data (6 Pages)
Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Health Physics Procedure GGGR-R5123-Rev.CY-OO1 Attachment C Quantile Plot For Cesium - 137 Survey Unit: 9106-0010 Survey Unit Name: Discharge Canal Mean: 1.17E-01 pCi/g 4.00E-01 3.50E-01 -
3.00E-01 0.
2.50E-01 2.00E-01 1.50E-01 o 1.00E-01 . . - .....
0 0 5.00E-02 0.00E+00 * -
0 20 40 60 80 100 Percentage Cs-1 37 Rank Percentage 6.73E-03 1 3 %
7.71 E-03 2 10 %
1.08E-02 3 17 %
2.78E-02 4 23 %
4.92E-02 5 30 %
6.72E-02 6 37 %
8.00E-02 7 43 %
8.57E-02 8 50 %
1.17E-01 9 57 %
1.30E-01 10 63 %
1.47E-01 11 70 %
1.94E-01 12 77 %
2.20E-01 13 83 %
2.60E-01 14 90 %
3.45E-01 15 97 %
Prepared By: m Date:
Reviewed By: Date:
I I
Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Health Physics Procedure GGGR-R5123-Rev.CY-OO1 Attachment C Quantile Plot For Cobalt - 60 Survey Unit: 9106-0010 Survey Unit Name: Discharge Canal Mean: 1.30E-01 pCi/g 7.OOE-01 6.OOE-01 -
. 5.OOE-01 4.OOE-01 0
3.00E-01 2.OOE-01 _ __,
o 1.OOE-01 O.OOE+00 -. " - __
-1.OOE-O1 20 4P 6 80 . . 1 Percentage Co-60 Rank Percentage
-2.26E-03 1 3%
-2.17E-05 2 10 %
1.48E-03 3 17 %
1.95E-02 4 23 %
2.28E-02 5 30 %
5.07E-02 6 37 %
5.08E-02 7 43 %
5.45E-02 8 50 %
8.30E-02 9 57 %
8.38E-02 10 63 %
1.82E-01 11 70 %
1.92E-01 12 77 %
2.27E-01 13 83 %
4.03E-01 14 90 %
5.75E-01 15 97 %
Prepared By: 15z, e", Date: //- Z?-0 Reviewed By: ýe
-5ý,, 46ý--, Date:
7-
Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Quantile Plot For Nickel - 63 Survey Unit: 9106-0010 Survey Unit Name: Discharge Canal Mean: -2.68E+00 pCi/g 8.OOE+00 -
6.OOE+00 -
"3 4.OOE+00 0.
0 2.00E+00
,0.00E+00 cu -2.00E+00 -
0 . . . . . . .--- .- 4 0.
-4.OOE+00 *- -.- ----- _
-6.OOE+00 Percentage Ni-63 Rank Percentage
-4.88E+00 1 3 %
-4.77E+00 2 10 %
-4.66E+00 3 17 %
-4.24E+00 4 23 %
-3.87E+00 5 30 %
-3.80E+00 6 37 %
-3.75E+00 7 43%
-3.71 E+00 8 50%
-2.72E+00 9 57%
-2.65E+00 10 63%
-2.58E+00 11 70%
-2.34E+00 12 77 %
-1.48E+00 13 83%
-1.07E+00 14 90%
6.33E+00 15 97 %
Prepared By: /" . - Date:
Reviewed By: f =J Date: /11.e,1edg
Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Cs - 137 Survey Unit: 9106-0010 Survey Unit Name: Discharge Canal Mean: 0.117 pCi/g 6
5-4-
Cr 3-UL 2-1-
0 K- I- -H -I _-
0.05 0.10 0.15 0.20 0.25 0.30 0.35 Upper End Value (pCi/g)
Upper End Observation Observation %
Value Frequency Frequency 0.05 5 33%
0.10 3 20%
0.15 3 20%
0.20 1 7%
0.25 1 7%
0.30 1 7%
0.35 1 7%
Total 15 100%
Prepared By: Date: 1,1-2 -OZ Reviewed By: Date: k/*:/
Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Cobalt-60 Survey Unit: 9106-0010 Survey Unit Name: Discharge Canal Mean: 0.130 pCi/g 12 10 Cr 6-
_._ 4 2
0 0.10 0.20 0.30 0.40 0.50 0.60 Upper End Value (pCi/g)
Upper End Observation Observation %
Value Frequency Frequency 0.10 10 67%
0.20 2 13%
0.30 1 7%
0.40 0 0%
0.50 1 7%
0.60 1 7%
Total 15 100%
Prepared By: ~52~ ,~4 Date: /(- 2-0 ý Reviewed By: Date: 11/,*//
/7
Health Physics Procedure GGGR-R5123-Rev.CY-001 Attachment C Frequency Plot For Nickel - 63 Survey Unit: 9106-0010 Survey Unit Name: Discharge Canal Mean: -2.679 pCi/g 12-10-
=o8 6 A C*
U 2
-5.00 -2.50 0.00 2.50 5.00 7.50 Upper End Value (pCi/g)
Upper End Observation Observation %
Value Frequency Frequency
-5.00 11 73%
-2.50 3 20%
0.00 0 0%
2.50 0 0%
5.00 0 0%
7.50 1 7%
Total 15 100%
Prepared By: '9 ~~4~2/ Date: /( - _ - P9 Reviewed By: By:
Reviewed Date:
DISCHARGE CANAL SURVEY UNIT 9106-0010 RELEASE RECORD Attachment 2e Sign Test Calculation (1 Page)
Health Physics Procedure GPP-GGGR-R5]121-000 Attachment A, Rev. CY-00 I MAJOR Sign Test Calculation Sheet For Multiple Radionuclisdes Survey Unit Number: 9106-0010 Survey Unit Name: Discharge Canal WP&IR#: 2006-021 Classification : 2 TYPE I (c error):0.05 ITYPE I (P3error):0.05 I Radionuclides: Cs- 137 Co-60 Ni-63 Survey Design DCGL (pCi/g): 6.01 2.90 549 Results Cs-137 Results Co-60 Results Ni-63 Weighted Sum (Ws) DCGL-Result Sign 2.60E-01 5.75E-01 -1.07E+00 2.40E-01 7.60E-01 1 2.78E-02 5.45E-02 -4.66E+00 1.49E-02 9.85E-01 I 6.72E-02 -2.26E-03 -3.75E+00 3.57E-03 9.96E-01 I 4.92E-02 8.38E-02 -4.77E+00 2.84E-02 9.72E-01 I 1.08E-02 -2.17E-05 -3.87E+00 -5.26E-03 1.01 E+00 I 1.47E-01 1.82E-01 -2.58E+00 8.25E-02 9.17E-01 I 8.OOE-02 8.30E-02 -2.34E+00 3.77E-02 9.62E-01 I 2.20E-01 1.95E-02 -2.65E+00 3.85E-02 9.61 E-01 1 1.30E-01 1.92E-01 -3.71 E+00 8.11E-02 9.19E-01 1 1.17E-01 5.08E-02 -3.80E+00 3.01E-02 9.70E-01 I 3.45E-01 2.27E-01 6.33E+00 1.47E-01 8.53E-01 I 1.94E-01 4.03E-01 -2.72E+00 1.66E-01 8.34E-01 1 7.71 E-03 1.48E-03 -4.88E+00 -7.1OE-03 1.01E+00 I 8.57E-02 5.07E-02 -4.24EE+00 2.40E-02 9.76E-01 I Number of Positive Differences (S+): 14 Critical Value: 11 Survey Unit: Meets Acceptance Criterion Performed By: _t_,z & ,- Date: /!- ** CI.
Independent Review: , Ss z Date: ] 6/-/
c)
Page 1 of 1
DISCHARGE CANAL SURVEY UNIT 9106-00 10 RELEASE RECORD Attachment 2f COMPASS DQA Surface Soil Report with Retrospective Power Curve (3 Pages)
DQA Surface Soil Report Assessment Summary Site: 9106-0010 (19 mrem/yr)
Planner(s): Dale Randall Survey Unit Name: 9106-0010 Report Number: 1 Survey Unit Samples: 15 Reference Area Samples: 0 Test Performed: Sign Test Result: Not Performed Judgmental Samples: 0 EMC Result: Not Performed Assessment
Conclusion:
Reject Null Hypothesis (Survey Unit PASSES)
Retrospective Power Curve 1
=
0.9
~~Ii
- 4. __ -
I-0.8 Ii --
I- -- -~
- =- 0.7 4-
- ____ I ____
-I--
0.6 I-5-
0.5 I.
- ______ -- ___________
- I- -1~ __
=a 0.4 I- il_
0.3 II 0.2 ~zzii _
r
-I- -- _
0.1 4-I-_--
0 ~zzIi zzzzz~~~
0.0 0.2 0.4 0.6 0.8 1.0 1.2 Unity Rule Sum-of-Ratios, including background
= Prospective Power U 1-beta Actual Power
- LBGR - - Estimated Power
- DCGL --- Retrospective Power COMPASS v0..0.e 11/12/006 Page I
DQA Surface Soil Report Survey Unit Data NOTE: Type = "S" indicates survey unit sample.
Type = "R" indicates reference area sample.
Sample Number Type Co-60 (pCiIg) Cs-137 (pCi/g) Ni-63 (pCi/g) 9106-0010-001F S 0.57 0.26 -1.07 9106-0010-002F S 0.05 0.03 -4.66 9106-0010-003F S 0 0.07 -3.75 9106-0010-004F S 0.08 0.05 -4.77 9106-0010-005F S 0 0.01 -3.87 9106-0010-006F S 0.18 0.15 -2.58 9106-0010-007F S 0.08 0.08 -2.34 9106-0010-008F S 0.02 0.22 -2.65 9106-0010-009F S 0.19 0.13 -3.71 9106-0010-01OF S 0.05 0.12 -3.8 9106-0010-011F S 0.23 0.34 6.33 9106-0010-012F S 0.4 0.19 -2.72 9106-0010-013F S 0 0.01 -4.88 9106-0010-014F S 0.05 0.09 -4.24 9106-0010-015F S 0.02 0.01 -1.48 Modified Data (Unity Rule SOR)
NOTE: Type = "S"indicates survey unit sample.
Type = "R" indicates reference area sample.
Sample Number Type Sum-of-Ratios (SOR) 9106-0010-001 F S 0.24 9106-0010-002F S 0.01 9106-0010-003F S 0 9106-0010-004F S 0.03 9106-0010-005F S -0.01 9106-0010-006F S 0.08 9106-0010-007F S 0.04 9106-0010-008F S 0.04 9106-0010-009F S 0.08 9106-0010-01OF S 0.03 9106-0010-011F S 0.15 9106-0010-012F S 0.17 9106-0010-013F S -0.01 9106-0010-014F S 0.02 9106-0010-015F S 0.01 I 11212006 Page 2 COMPASS vl.O.O COMPASS vl.0.0 111212006 Page 2
W DQA Surface Soil Report Basic Statistical Quantities Summary Statistic Survey Unit Background DQO Results Sample Number 15 N/A N=13 Mean (SOR) 0.06 N/A 0.15 Median (SOR) 0.03 N/A N/A Std Dev (SOR) 0.07 N/A 0.12 High Value (SOR) 0.24 N/A N/A Low Value (SOR) -0.01 N/A N/A COMPASS v1..O2 11/2/2006 Page 3