ML063180302

From kanterella
Jump to navigation Jump to search
Final Accident Sequence Precursor Analysis
ML063180302
Person / Time
Site: Saint Lucie  NextEra Energy icon.png
Issue date: 11/16/2006
From: Moroney B
NRC/NRR/ADRO/DORL/LPLII-2
To: Stall J
Florida Power & Light Co
Shared Package
ML063180289 List:
References
IR-04-004
Download: ML063180302 (4)


Text

November 16, 2006 Mr. J. A. Stall Senior Vice President, Nuclear and Chief Nuclear Officer Florida Power and Light Company P.O. Box 14000 Juno Beach, Florida 33408-0420

SUBJECT:

ST. LUCIE NUCLEAR PLANT, UNITS 1 AND 2 - FINAL ACCIDENT SEQUENCE PRECURSOR ANALYSIS OF A SEPTEMBER 2004 OPERATIONAL EVENT

Dear Mr. Stall:

The enclosure provides the final results of the Accident Sequence Precursor (ASP) analysis of an event that occurred at St. Lucie, Units 1 and 2, as documented in Licensee Event Report 335/04-004. The subject event occurred on September 25, 2004, during which a dual-unit loss of offsite power occurred at the St. Lucie site. The ASP analysis calculated a mean conditional core damage probability of 1 x 10-5.

The U.S. Nuclear Regulatory Commission (NRC) established the ASP Program in 1979 in response to the Risk Assessment Review Group report (see NUREG/CR-0400, dated September 1978). The ASP Program systematically evaluates U.S. nuclear power plant operating experience to identify, document, and rank the operating events that were most likely to have led to inadequate core cooling and severe core damage (precursors), accounting for the likelihood of additional failures.

The ASP Program has the following objectives:

Provide a measure for trending nuclear power plant core damage risk.

Provide a partial check on dominant core damage scenarios predicted by probabilistic risk assessments.

Provide feedback to regulatory activities.

Evaluate the adequacy of NRC programs.

The NRC also uses the ASP Program to monitor performance against the safety goal established in the agency's Strategic Plan. (See NUREG-1100, Vol. 21, dated February 2005.)

For more information about the ASP program, see the annual ASP program report at http://www.nrc.gov/reading-rm/doc-collections/commission/secys/2005/secy2005-0192/2005-01 92scy.pdf.

J. Stall The enclosure is provided for your information and no response is requested. The preliminary ASP analysis was sent to you on February 16, 2006, with a request for peer review and comment. No comments were received.

Sincerely,

/RA/

Brendan T. Moroney, Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-335 and 50-389

Enclosure:

Final ASP Analysis cc w/encl: See next page

ML063180302 NRR-106 OFFICE LPL2-2/PM LPL2-2/LA LPL2-2/BC(A)

NAME BMoroney /ma BClayton DPickett DATE 11/ 15 /06 11/ 15 /06 11/16 /06

Mr. J. A. Stall ST. LUCIE PLANT Florida Power and Light Company cc:

Mr. William E. Webster Vice President, Nuclear Operations Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Senior Resident Inspector St. Lucie Plant U.S. Nuclear Regulatory Commission P.O. Box 6090 Jensen Beach, Florida 34957 Craig Fugate, Director Division of Emergency Preparedness Department of Community Affairs 2740 Centerview Drive Tallahassee, Florida 32399-2100 M. S. Ross, Managing Attorney Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Marjan Mashhadi, Senior Attorney Florida Power & Light Company 801 Pennsylvania Avenue, NW.

Suite 220 Washington, DC 20004 Mr. Douglas Anderson County Administrator St. Lucie County 2300 Virginia Avenue Fort Pierce, Florida 34982 Mr. William A. Passetti, Chief Department of Health Bureau of Radiation Control 2020 Capital Circle, SE, Bin #C21 Tallahassee, Florida 32399-1741 Mr. Gordon L. Johnston Site Vice President St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957-2000 Mr. Christopher R. Costanzo Plant General Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957 Mr. Terry Patterson Licensing Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957 Mark Warner, Vice President Nuclear Operations Support Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Mr. Rajiv S. Kundalkar Vice President - Nuclear Engineering Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Mr. J. Kammel Radiological Emergency Planning Administrator Department of Public Safety 6000 Southeast Tower Drive Stuart, Florida 34997 Mr. Bill Parks Operations Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957-2000 Mr. Seth B. Duston Training Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957-2000