ML063130267

From kanterella
Jump to navigation Jump to search

11/7/2006 E-Mail from G. Michael, Arizona Public Service Company, to M. Fields, NRC, Re Information Needed for GSI-191 Extension Request
ML063130267
Person / Time
Site: Palo Verde 
Issue date: 11/07/2006
From: Michael G
Arizona Public Service Co
To: Fields M
NRC/NRR/ADRO/DORL/LPLIV
Fields M, NRR/DORL/LP4, 415-3062
References
TAC MD3335
Download: ML063130267 (2)


Text

From:

<Glenn.Michael@aps.com>

To:

<mbf1@nrc.gov>

Date:

11/7/2006 5:12:46 PM

Subject:

FW: Information needed for Palo Verde GSI-191 Extension Request

Mel, Please see Engineering's response below.

Glenn


Original Message-----

From: Engbring, Thomas P(Z34745)

Sent: Tuesday, November 07, 2006 3:10 PM To: Michael, Glenn A(Z01119)

Cc: Engbring, Thomas P(Z34745); Brutcher, Mark A(Z17480)

Subject:

RE: Information needed for Palo Verde GSI-191 Extension Request

Glenn, Calculation 13-MC-SI-0309, revision 5 (page 52 of 88) calculated a total of 154.57 ft3 of fiberfrax installed in unit 2. During the current unit 2 outage (2R13), all known fiberfrax was removed from unit 2.

Original Message-----

From: Michael, Glenn A(Z01119)

Sent: Tuesday, November 07, 2006 11:39 AM To: Engbring, Thomas P(Z34745)

Subject:

FW: Information needed for Palo Verde GSI-191 Extension Request Tom, Can you provide the info requested below?


Original Message-----

From: Mel Fields [1]

Sent: Tuesday, November 07, 2006 11:37 AM To: Michael, Glenn A(Z01119)

Cc: Weber, Thomas N(Z00499)

Subject:

Information needed for Palo Verde GSI-191 Extension Request See Q below - an email response is suffiicent...

"Please provide the quantities of Fiberfax being removed from PV2 and the quantity of residual Fiberfax to remain in the PV2 containment."

CC:

<Thomas.N.Weber@aps.com>, <Thomas.Engbring@aps.com>

Mail Envelope Properties (455104C8.FE8 : 7 : 36840)

Subject:

FW: Information needed for Palo Verde GSI-191 Extension Request Creation Date 11/7/2006 5:12:06 PM From:

<Glenn.Michael@aps.com>

Created By:

Glenn.Michael@aps.com Recipients

nrc.gov OWGWPO02.HQGWDO01 MBF1 (Mel Fields) aps.com Thomas.Engbring CC Thomas.N.Weber CC Post Office Route OWGWPO02.HQGWDO01 nrc.gov aps.com Files Size Date & Time MESSAGE 1211 11/7/2006 5:12:06 PM Mime.822 3241 Options Expiration Date:

None Priority:

Standard ReplyRequested:

No Return Notification:

None Concealed

Subject:

No Security:

Standard