E-mail from P. Donahue of Entergy, Regarding Bi-Weekly IPEC Monitoring Well Date Report
ML063000488
Person / Time
Site: Indian Point  
Issue date: 09/13/2006
From: Donahue P
Entergy Nuclear Operations
To: Noggle J, Jason White
NRC Region 1
References
FOIA/PA-2006-0314
Download: ML063000488 (3)


Text

~JohnWhit

- B-Weely PEC Monitoring WlDaaReportPag1 I

Paqe i,ý From:

"Dojahue, Patrick J"/PDonahu@entergy.com>

To:

<jrvl @ nrc.gov>, <jdn @ nrc.gov>, <tbrice@ gw.dec.state.ny. us>, "Larry Rosenmann"

<larosenm @ gw.dec.state.ny.us>

Date:

09/13/2006 12:06:11 PM

Subject:

Bi-Weekly IPEC Monitoring Well Data Report Gentlemen, Attached is the most recent monitoring well data reports for the IPEC groundwater investigation for your review prior to the Thursday conference call.

Sincerely,

<<IpecWell_Report_09-13-06.pdf>>

Patrick Donahue Sr. HP/Chemistry Specialist Entergy Nuclear Northeast Indian Point Energy Center 450 Broadway, Suite 3 Buchanan, NY 10511 pdonahu@entergy.com (914) 736-8405 Voice (914) 734-6247 Fax This e-mail and any attachments thereto are intended only for the use by the addressee(s) named herein and contain proprietary and confidential information. If you are not the intended recipient of this e-mail, you are hereby notified that any dissemination, distribution, or copying of this e-mail, and any attachments thereto, is strictly prohibited. If you have received this e-mail in error, please immediately notify me by telephone and permanently delete the original and any copy of any e-mail and any printout thereof.

CC:

"Adler, Joseph J." <jadler@entergy.com>, "Sachatello, Ronald"

<rsach90@entergy.com>, "Hinrichs, Gary H" <ghinric@entergy.com>, "Wilson, Daniel"

<DWilson @ entergy.com>

John White - Ipec WellReport09-13-06.pdf P t g elj Latest Ground Water Well Sample Data Well Name LAF-001 LAF-002 LAF-003 MW-101 MW-103 MW-105 MW-107 MW-108 MW-109 MW-110 MW-111 MW-112 MW-30-72 MW-30-74 MW-30-78 MW-30-83 MW-30-88 MW-31 MW-32 MW-33 MW-34 MW-35 MW-36-26 MW-36-41 MW-36-53 MW-37-22 MW-37-32 MW-37-40 MW-37-57 MW-38 MW-38-Disch MW-39 MW-40 MW-41-42 MW-41-64 MW-42-41 MW-42-43 MW-42-46 MW-42-48 MW-42-51 MW-42-79 MW-43-28 MW-43-62 MW-44-104 MW-44-67 MW-45-43 MW-45-62 MW-46 MW-47-56 MW-47-80 Well Status Developed

-Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed N/A Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Developed Last Sample Date Last Sample Result 6/6/2006 13:58:

6/6/2006 12:47:

6/6/2006 10:23:

6/8/2006 9:10:

6/8/2006 10:40:

6/8/2006 10:15:

6/6/2006 13:30:

5/13/2006 10:53:

5/13/2006 10:10:

6/8/2006 9:50:

6/23/2006 8:35:

6/8/2006 12:30:

6/23/2006 13:30:

8/18/2006 14:45:

6/22/2006 14:10:

6/22/2006 11:40:

8/22/2006 13:15:

6/26/2006 8:55:

6/27/2006 13:00:

8/30/2006 13:00:

8/24/2006 12:18:

6/26/2006 10:40:

8/28/2006 10:30:

8/28/2006 10:10:

8/28/2006 10:00:

6/27/2006 10:25:

6/27/2006 9:15:

6/27/2006 10:15:

6/27/2006 9:35:

9/5/2006 11:30:

9/5/2006 10:50:

8/16/2006 11:15:

9/12/2006 13:20:

8/16/2006 13:15:

8/16/2006 13;00:

7/21/2006 11:35:

7/21/2006 10:33:

7/21/2006 9:00:

7/20/2006 14:32:

4/7/2006 17:52:

4/7/2006 17:58:

8/16/2006 12:10:

8/16/2006 11:55:

8/4/2006 9:40:

7/20/2006 11:15:

8/11/2006 10:00:

8/11/2006 9:45:

8/4/2006 8:40:

7/18/2006 10:13:

7/18/2006 8:51:

6/6/2006 13:58:

6/6/2006 12:47:

6/6/2006 10:23:

6/8/2006 9:10:

6/8/2006 10.40:

6/8/2006 10:15:

6/6/2006 13:30:

5/13/2006 10:53:

5/13/2006 10:10:

6/8/2006 9:50:

6/23/2006 8:35:

6/8/2006 12:30:

6/23/2006 13:30:

6/23/2006 10:50:

6/22/2006 14:10:

6/22/2006 11:40:

6/26/2006 8:55:

6/27/2006 13:00:

8/4/2006 8:15:

7/26/2006 10:20:

6/26/2006 10:40:

6/5/2006 12:20:

6/5/2006 11:30:

6/5/2006 11:30:

6/27/200 6 10:25:

6/27/200 6 9:15:

6/27/200 6 10:15:

6/27/200 6 9:35:

8/7/2006 13:23:

8/7/2006 13:50:

7/13/2006 14:05:

8/9/2006 10:35:

7/14/2006 8:45:

7/18/2006 13:04:

7/21/2006 11:35:

7/21/200 6 10:33:

7/21/2006 9:00:

7/20/2006 14:32:

4/7/2006 17:52:

4/7/2006 17:58:

7/12/2006 9:40:

7/12/2006 10:05:

8/4/2006 9:40:

5/24/2006 9:05:

7/14/2006 9:30:

6/12/2006 11:00:

8/4/2006 8:40:

7/18/200 6 10:13:

7/18/2006 8:51:

H-3 ND ND ND ND 1.70E+02 ND ND 2.78E+02 3.39E+02 2.25E+02 2.62E+05 ND 4.03E+05 3.92E+05 3.26E+05 1.81E+05 1.33E+04 4.44E+04 1.84E+05 4.07E+04 1.74E+04 2.02E+02 2.05E+04 2.40E+04 1.05E+04 7.92E+03 1.42E+04 4.48E+04 ND ND ND ND 9.83E+02 2.43E+02 3.58E+03 3.05E+03 2.32E+03 2.80E+03 2.51 E+03 7.92E+02 ND ND 7.61 E+02 2.37E+02 4.19E+02 1.02E+03 1.15E+03 ND 1.87E+03 Results in pCi/L Sr-90 Prelim ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 2.30E+00 4.33E+1 4.42E+00 5.10E+I 9.57E+00 7.59E++/-

2.98E+01 1.07E+I 2.44E+01 2.12E+I 2.73E+01 2.02E+

ND ND 7.02E+00 4.85E+(

2.17E+00 1.52E+(

1.30E+01 1.61 E+

1.28E+01 1.95E+(

1.09E+01 1.70E+(

1.52E+01 1.62E+(

1.89E+00 ND ND ND ND ND ND ND ND 7.41E-01 ND ND ND ND ND ND 2.47E+(

ND ND 2.86E+00 3.26E+

Sr 01 01 01 01 01 01 01 300 00 Date Printed: 09/13/2006 at 11:44 Page 1 of 2

F John White - bc Well ReDort 09-13-06.Ddf Pace 2 d]

John White - loec Well ReDort 09-13-06.odf Paae 2:1 I

-~

-~---,-.--

__---~--~-.~---,--,

=

l Well Name MW-48-2 3 MW-48-38 MW-48-River MW-49-25 MW-49-42 MW-49-65 MW-50-42 MW-50-67 MW-51 MW-52-200 MW-53-120 MW-53-80 MW-54-206 MW-55-78 MW-56-85 MW-57-45 MW-58-71 MW-65-80 U2-CST-W U3-1 U3-2 U3-3 U3-4D U3-T1 U3-T2 Well Status Developed Developed N/A Developed Developed Developed Developed Developed Developed Developed Under Development Developed Under Development Under Development Under Development Developed Developed Under Development Developed Developed Developed Developed Developed Developed Developed Last Sample Date 9/5/2006 10:05:

9/5/2006 10:20:

9/5/2006 10:50:

8/28/2006 12:30:

8/28/2006 12:40:

8/28/2006 12:35:

8/28/2006 11:50:

8/28/2006 12:05:

9/12/2006 10:40:

7/19/2006 13:20:

8/30/2006 11:30:

8/23/2006 12:50:

9/7/2006 13:00:

8/25/2006 9:20:

9/8/2006 11:15:

8/24/2006 9:30:

8/212006 9:37:

9/8/2006 9:40:

10/21/2005 12:00:

6/22/2006 9:55:

6/22(2006 9:23:

6/22/2006 9:05:

6/22/2006 10:20:

8/15/2006 11:30:

8/15/2006 10:30:

Last Sample Result 8/8/2006 10:30:

8/8/2006 10:20:

8/8/2006 10:40:

7/7/2006 9:15:

7/7/2006 9:15:

7/7/2006 9:10:

7/3/2006 11:35:

7/3/2006 11:00:

8/10/200 6 13:20:

7/19/2006 13:20:

8/2/2006 9:37:

10/21/2005 12:00:

6/22/2006 9:55:

6/22/2006 9:23:

6/22/2006 9:05:

6/22/2006 10:20:

7/12/2006 12:50:

7/12/200 6 12:25:

H-3 ND ND ND 1.00E+04 5.85E+03 4.63E+03 3.98E+02 8.62E+03 ND 3.37E+02 4.26E+02 ND

.7.55E+02 1.97E+02 1.79E+02 7.10E+02 6.84E+02 1.83E+03 Results in pCi/L Sr-90 1.26E+01 1.92E+01 1.56E+01 3.45E+00 2.53E+01 Prelim Sr 1.53E+01 2.25E+01 1.60E+01 4.89E+00 2.88E+01 ND ND ND ND ND 1.40E+00 ND ND ND ND ND ND ND ND 2.40E+00 ND Wells Never Sampled Well Name MW-59 MW-60 MW-61 MW-62 MW-63 MW-64 Well Status Under Development Under Development Under Development Under Development Under Development Under Development

1. "Prelim Sr" is an analysis that provides an initial approximation of strontium concentration.

"Sr-9(Y' results are the official concentrations and should replace the initial "Prelim Sr" result.

2. This information is propriety information between IPEC and the recipient pending official release by Entergy Corporation.
3. ND = (Non Detect). Sample results less than 3 standard deviations or less than the MDC.
4. N/A = Not Applicable.

MW-38-Disch and MW-48-River are grab samples from the Discharge Canal and Hudson River.

Date Printed: 09/13/2006 at 11:44 Page 2 of 2