ML063000384

From kanterella
Jump to navigation Jump to search
E-mail from T. Rice of DEC, Regarding Phase 1 and 2 State Results
ML063000384
Person / Time
Site: Indian Point  
Issue date: 07/21/2006
From: Rice T
State of NY, Dept of Environmental Conservation
To: James Adler, Kottan J, Mayer D, Noggle J, Jason White
- No Known Affiliation, Entergy Nuclear Operations, NRC Region 1
References
FOIA/PA-2006-0314
Download: ML063000384 (6)


Text

......

White - Phase 1 and 2 State Results Page1 iI From:

"Timothy Rice" <tbrice @ gw.dec.state.ny.us>

To:

<DMayerl @entergy.com>, "James Noggle" <JDN @nrc.gov>, "James Kottan"

<JJK@ nrc.gov>, "John White" <jrwl @nrc.gov>, "Jay Adler" <adler@tlgservices.com>

Date:

07/21/2006 1:50:12 PM

Subject:

Phase 1 and 2 State Results Attached is an Excel table with State results through Phase 2.

Sheet 2 includes Hudson River sediment samples.

Tim Rice

1:IJ -o h n Wh it e-TEX-T-. h-tm----

Pacei&1 Attached is an Excel table with State results through Phase 2.

Sheet 2 includes Hudson River sediment samples.

Tim Rice

John White - state IP Sample Results as of07-06.xls Page

§zDiMEIIT$ A PLES~

Sampling Date Sample Location Sr-90 pcilg, Cs-137 pCi/g Co-60 pCi/g 5/10/06 Verplank Beach 1.15 +/- 3.98E-1 1.89E-1 +/- 6.76E-2

< 7.19E-2 Verplank Beach - Dup 6.01 E-1 +/- 3.25E-1 2.36E-1 +/- 5.99E-2

< 7.23E-2 White Beach

< 6.43E-1

< 9.19E-2

< 1.09E-1 Manitou Beach 1.70 +/- 5.17E-1

< 1.73E-1

< 1.47E-1 Lents Cove

< 6.75E-1

< 7.77E-2

< 7.42E-2 Sediment samp es counted by contract lab.

All Samples shc w Naturally Ocurring Radioactive M terials

J_ýohn.hite -, StateP Sample Results as of 7-06.xls MfUMdI FUIL '.JUfuIiu dU1 M~VbtjSIycdIUII OUI 1ii1 Idl y IMJ TO nt1UILZ> dtZ UI --UdCtT1 Sampling Date Sample ID Sample Location Tritium pCi/I Sr90 pCi/I Gamma Spec 10/21/05 200520855628 U2 CST

<110 NA NA 10/21/05 200520855629 U3-T2 1420 +/- 160 NA NA 10/21/05 200520855630 U3-2 510 +/- 130 NA NA 10/21/05 200520855631 MW-1 11 267000+/- 8000 1.9 +/- 0.7

  • ND 10/21/05 200520855632 U3-4 340 +/- 120 NA NA 10/21/05 200520855633 U3-1

<110 NA NA 10/21/05 200520855634 U3-3

<110 NA NA 10/21/05 200520855535 U3-T1

<110 NA NA 11/30/05 200520855645 Trap Rock Quarry 90 +/- 60

<0.5 ***

ND 11/30/05 200520855646 Algonquin Creek

<60

<0.5 -

RDP 11/30/05 200520855647 5th Street Well

<60

<0.5 ***

RDP 11/30/05 200520855648 Gypsum Plant Outfall

<60

<0.5 RDP 12/6/05 200520855658 LaFarge Gypsum Well #1

<50 NA NA 12/6/05 200520855659 LaFarge Gypsum Well #3

<50 NA NA 12/8/05 200520855654 MW38 700 +/- 120 NA NA 12/8/05 200520855655 MW 101

<50 NA NA 12/8/05 200520855656 MW105 100 +/-90 NA NA 12/8/05 200520855657 MW 107

<50 NA NA 2/7/06 200620865001 MW-30 72' 3.76E5 +/- 0.11 E5

<0.5 ND 2/7/06 200620865002 MW-31 3.38E4 +/- 0.12E4

<0.5 ND 2/7/06 200620865003 MW-32 1.92E4 +/- 0.07E4

<0.6 ND 2/7/06 200620865004 MW-33 2.02E5 +/- 0.06E5

<0.5 ND 2/7/06 200620865005 MW-34 1.74E5 +/- 0.05E5

<0.6 ND 2/7/06 200620865006 MW-35 8.9E4 +/- 0.3E4

<0.5 ND 2/7/06 200620865007 MW-36 2.1 E4 +/- 0.08E4 1.1 +/- 0.6 ND 2/8/06 200620865008 MW-38

<110

<0.5 ND 2/8/06 200620865009 MW-48 250 +/- 110

<0.5 ND 2/7/06 200620865010 MW-1 11 1.96E5 +/- 0.06E5 1.6 +/- 0.05 ND 1/30/06 200620865011 Doodletown Bight @ PIP Maint.

<90

<0.5 ND 2/8/06 200620865012 Algonquin Creek

<90

<0.6 ND 2/8/06 200620865013 Trap Rock Quarry

<90 0.9 +/- 0.6 ND 1/30/06 200620865014 Lake Kanawauke

<90

<0.4 ND 1/30/06 200620865015 Ramapo River @ Arden Rd

<90

<0.4 ND 2/8/06 200620865016 Hudson River Middle of waterfront

<90

<0.4 ND 2/8/06 200620865017 Hudson River Unit 2 Outfall

<90

<0.4 ND 2/8/06 200620865018 Hudson River Off Manhole 1

<90

<0.4 ND 2/8/06 200620865019 Gypsum Plant Outfall

<90

<0.4 ND 2/8/06 200620865020 Hudson River North of IPEC

<90

<1.0 ND

John White- - State-- IP Sample Results as of 7-06.xls 5-29 h..ý 1.

State%

Sam ple R ult-t s as f

7l0lr

.l Page 1

3 i m 11 a-loin Sampling Date Sample ID Sample Location Tritium pCi/I Sr-90 pCi/I Gamma Spec 2/28/06 200620865024 MW-37 22' 1.48E4 +/- 0.06E4 INS ND 2/28/06 200620865025 MW-37 32' 2.89E4 +/- 0.10E4 INS ND 2/28/06 200620865026 MW-37 40' 1.61 E4 +/- 0.06E4 INS ND 2/28/06 200620865027 MW-37 57' 1.54E4 +/- 0.06E4 INS ND 3/10/06 200620865028 MW-37 22' 2.20E4 +/- 0.08E4 8.3 +/- 0.7 ND 3/10/06 200620865029 MW-37 32' 2.79E4 +/- 0.10E4 23.9 +4-1.1 ND 3/10/06 200620865030 MW-37 40' **

1.63E4 +/- 0.06E4 22.3 +/- 1.2 ND 3/10/06 200620865031 MW-37 57' 1.54E4 +/- 0.06E4 27.3 +/- 1.2 ND 3/22/06 200620865040 MW-49 25.5' 1.53E4 +/- 0.06E4 17.0 +/- 0.9 ND 3/22/06 200620865041 MW-49 42' 9.4E3 +/- 0.4E3 24.1 +/- 1.1 ND 3/22/06 200620865042 MW-49 65.5' 6.7E3 +/- 0.3E3 23.8 +/- 1.1 ND 3/22/06 200620865043 MW-50 42' 7.7E3 +/- 0.4E3 25.9 +/- 1.2 ND 3/22/06 200620865044 MW-50 67' 9.8E3 +/- 0.4E3 31.6 +/-1.3 ND 3/23/06 200620865045 MW-42 49' 2.7E3 +/- 0.2E3 60 +/- 2 Cs137, Co6O 1.:

MW-42 49' with solids, Cs-137 1.99E4 +/- 6.12E2 MW-42 49' decanted, Cs-137 1.31 E4 +/- 0.04E4 MW-42 49' with solids, Co-60 23 +/- 6 MW-42 49' decanted, Co-60 21 +/- 11 3/24/06 200620865046 MW-42 78' 4.7E2 +/- 1.2E2

<1.0 CS137, Co60, K40, RDP MW-42 78' with solids, Cs-137 1.12E3 +/- 0.04E3 MW-42 78' decanted, Cs-137 1.85E2 +/- 0.4E2 MW-42 78' with solids, Co-60 3.4 +/- 0.9 MW-42 78' decanted, Co-60

<5.9 MW-42 78' with solids, K-40 40 +/- 10 MW-42 78' decanted, K-40

<98 3/23/06 200620865037 MW-36 26' 3.53E4 +/- 0.12E4 0.9 +/- 0.4 ND 3/24/06 200620865038 MW-36 41' 5.97E4 +/- 0.19E4 4.4 +/- 0.5 ND 3/23/06 200620865039 MW-36 52' 2.65E4 +/- 0.09E4 6.1 +/- 0.5 ND 4/13/06 200620865047 MW-47 56' 5.0E2 +/-1.4E2 0.8 +/- 0.7 ND 4/13/06 200620865048 MW-47 80' 2.1 E3 +/- 0.2E3 3.9 +/- 0.4 ND 4/12/06 200620865049 MW-46 30' 1.78E3 +/- 0.18E3

<0.9 ND 4/11/06 200620865050 MW-40 200.****

<100 0.7 +/- 0.4 ND 4/11/06 200620865051 MW-51 200' 1.5E2 +/- 1.1 E2

<0.4 ND 4/12/06 200620865052 MW-48 37.5' 1.2E2 +/- 1.0E2

<0.7 RDP 4/12/06 200620865053 MW-48 52' 3.7E2 +/- 1.3E2

<0.7 ND 4/12/06 200620865054 MW-41 41' 5.8E2 +/- 1.4E2 5.0 +/- 0.8 ND 4/12/06 1 200620865055 MW-4.1 63' 4.7E2 +/- 1.3E2 5.7 +/- 0.5 ND

IF State IP Sam le Results as of 7-06.xls Pag'ý ý4 Witn-'Sta-ri-rri ater-mv PILIV Sam pie'1 R

s ta ofl 1

s-ts-Pa gO-t-

j Sampling Date Sample ID Sample Location Tritium pCi/I Sr-90 pCi/I Gamma Spec 4/12/06 200620865056 MW-43 28' 2.9E2 +/- 1.2E2

<0.4 K40, RDP 4/12/06 200620865057 MW-43 62.****

<110 0.6 +4- 0.4 ND 4/11/06 200620865058 Fishkill Creek

<130

<0.4 ND 4/11/06 200620865059 Philpse Brook

<90

<0.4 ND 4/17/06 200620865060 MH-5 U2 Curtain prior to outage 2.3E2 +/- 1.0E2

<0.4 ND 4/18/06 200620865061 Hudson River near MH1 Discharge

<90

<0.5 ND GA - Gross Alpha, GB - Gross Beta NA - Not Applicable (This analysis was not performed)

ND - Non Detect ( No readings at or above detection limits)

RDP - Dissolved Radon Decay Products INS - Insufficient Sample Volume for this Analysis Sr-90 Bkg Range =0.8 - 1.3 pCi/I NYSDOH Data, 1987 - 1990.

  • Analysis for Sr-90 repeated with 600ml of sample for better counting statistics
    • Review of GA Result requested -->sample high in suspended solids Result recalculated to account for new filter paper
  • Sr-90 results become < 0.7 pCi/I @ 3 sigma uncertainty.