Generic ALARA Evaluation Comparison Worksheet Survey Area:

OOL-09 Survey Unit:

01 Reference Generic ALARA Evaluation No.:

YA-REPT-00-003-05 Applicable Generic ALARA AL:

165 Radionuclide Average Concentration DCGL fraction DCGL 1

Co-60 0.0059 1.4 4.21 E-03 2

CS-137 0.1457 3

4.86E-02 3

4 Z(fraction DCGL):

5.28E-02 If the C(fraction DCGL) < the generic ALARA AL, then the generic ALARA evaluation is applicable to the survey unit.

Check one:

X Gener~c ALARA AL IS satisfied.

Generic ALARA AL IS NOT satisfied.

Prepared by: J. Hummer Date:

Reviewed by: Martin Erickson Date: L,//JfiA FSS Project ManagerIRaktion Pr

Generic ALARA Evaluation Comparison Worksheet Survey Area:

OOL-09 Survey Unit:

02 Reference Generic ALARA Evaluation No.:

YA-REPT-00-003-05 Applicable Generic AURA AL:

165 Radionuclide Average Concentration DCGL fraction DCGL 1

CO-60 0.0059 1.4 4.21 E-03 2

CS-137 0.1457 3

4.86E-02 3

4 Z(fraction DCGL):

5.28E-02 If the C(fraction DCGL) < the generic ALARA AL, then the generic ALARA evaluation is applicable to the survey unit.

Check one:

X Generic ALARA AL satisfied.

Generic AURA AL IS NOT satisfied.

Prepared by: Nancy Touie Date:

611 212006 Reviewed by: Martin Erickson Date:

611 212006 FSS Project Mana iation Prafection Manager

Generic ALARA Evaluation Comparison Worksheet Survey Area:

OOL-09 Survey Unit:

03 Reference Generic ALARA Evaluation No.:

YA-REPT-00-003-05 Applicable Generic ALARA AL:

165 Radionuclide Average Concentration DCGL fraction DCGL 1

CS-137 0.0864 3

2.88E-02 2

0 3

4 X(fraction DCGL):

2.88E-02 If the C(fraction DCGL) < the generic ALARA AL, then the generic ALARA evaluation is applicable to the survey unit.

Check one:

X Generic ALARA AL IS satisfied.

Generic ALARA AL IS NOT satisfied.

Prepared by: Nancy Touie Date:

711 012006 Reviewed by:

Date:.?A3AL

Generic ALARA Evaluation Comparison Worksheet Survey Area:

OOL-09 Survey Unit:

04 Reference Generic ALARA Evaluation No.:

YA-REPT-00-003-05 Applicable Generic ALARA AL:

165 Radionuclide Average Concentration DCGL fraction DCGL 1

CS-137 0.0864 3

2.88E-02 2

0 3

4 C(fraction DCGL):

2.88E-02 If the C(fraction DCGL) < the generic ALARA AL, then the generic ALARA evaluation is applicable to the survey unit.

Check one:

X Generic ALARA AL 5 satisfied.

Generic ALARA AL IS NOT satisfied.

Prepared by: Nancy Tozzie Date:

711 012006 Reviewed by:

3 Date: 2b)/a L.

nagedRadiation Protection Manager

Generic ALARA Evaluation Comparison Worksheet Survey Area:

OOL-09 Survey Unit:

05 Reference Generic ALARA Evaluation No.:

YA-REPT-00-003-05 Applicable Generic ALARA AL:

165 Radionuclide Average Concentration DCGL fraction DCGL 1

CS-I37 0.052 3

1.73E-02 2

3 4

C(fraction DCGL):

1.73E-02 If the C(fraction DCGL) < the generic ALARA AL, then the generic ALARA evaluation is applicable to the survey unit.

Check one:

X Generic ALARA AL satisfied.

Generic ALARA AL IS NOT satisfied.

Prepared by: Robert Tozzi Date:

611 512006 Reviewed by:

C.,

i Date: 419r/0 C,

FSS ~

  • c t ManagdrlRadiation Protection Manager