1CAN100601, Supplement to License Amendment Request to Support Use of Metamic Poison Insert Assemblies in Spent Fuel Pool

From kanterella
(Redirected from ML062910244)
Jump to navigation Jump to search

Supplement to License Amendment Request to Support Use of Metamic Poison Insert Assemblies in Spent Fuel Pool
ML062910244
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 10/04/2006
From: Marlow T
Entergy Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
1CAN100601
Download: ML062910244 (47)


Text

- EEntergy Operations, Inc.

Elnftergy1 1448 S.R. 333 Tel 479-858-4601 Thomas A. Marlow

Director, Nuclear Safety Assurance 1CAN100601 October 4, 2006 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555

SUBJECT:

Supplement to License Amendment Request to Support the Use of Metamic Poison Insert Assemblies in the Spent Fuel Pool Arkansas Nuclear One, Unit 1 (ANO-1)

Docket No. 50-313 License No. DPR-51

REFERENCES:

1.

Letter to the NRC dated July 27, 2006, "License Amendment Request to Support the Use of Metamic Poison Insert Assemblies in the Spent Fuel Pool" (1CAN070603)

Dear Sir or Madam:

Pursuant to 10 CFR 50.90, Entergy Operations, Inc. (Entergy) requested an amendment to the Arkansas Nuclear One, Unit 1 (ANO-1) Technical Specification (TS) 3.7.14, Spent Fuel Pool Concentration, TS 3.7.15, Spent Fuel Pool Storage, and TS 4.3, Fuel Storage (Reference 1).

On August 31, 2006, Holtec International identified an error in the criticality safety evaluation that was included in the original submittal. In the criticality calculations for the ANO-1 fuel racks, the material composition for spent fuel is transferred between the CASMO depletion code and the Monte Carlo (MCNP4a) criticality code using an automated process (script). When the script generated for the ANO-1 project was reviewed for use in another project, it was determined that the script contained a typographical error that affected the oxygen atom density in the spent fuel. As a result, the density of all actinides and fission products were underestimated by about 3% in the MCNP4a calculations. The consequence is a slight under prediction of the k-effective in the analysis; reducing margin. The reduction in margin affects the proposed analysis for the ANO-1 spent fuel pool and has no impact on the current criticality analysis. According to the vendor, the script is new and its use limited to two analyses; ANO-1 SFP and another commercial nuclear facility. The error was documented in the ANO corrective action program (CR-ANO-1-2006-1178).

The correction resulted in a slightly higher minimum burnup requirement for the fuel assemblies that are stored in Regions 1 and 2 of the spent fuel pool and reflected in TS 3.7.15-1. In addition, the minimum boron concentration required to ensure K-effective remains < 0.95 (TS 4.3.1.1.b) was changed. This number was slightly lower than the previously submitted value due to the statistical characteristics of the MCNP4a criticality code.

Ao--o

1CAN100601 Page 2 of 3 During the initial rework of the poison panel assemblies (PIAs), it was determined that minor weld changes to the top and bottom of the PIA and inconsequential material changes to the bottom were needed. This results in slight wording changes in the summary of the structural considerations. The original structural analysis remains bounding. In addition, a typographical error is corrected.

Attached are the corrected pages only. Revision bars mark the changes. Please remove the designated pages from the original submittal and insert the corrected pages as follows:

  • - pages 3, 5, 17, and 18

" Attachments 2 and 3 - pages 3.7.15-2 and 4.0-3

" - page B 3.7.14-1 and B 3.7.15-1

" - pages 4-3, 4-4, 4-21, 4-24, 4-25, 4-26, 4-27, 4-28 (text roll-over only),

4-29 (text roll-over only) 4-39, 4-40, 4-43,.4-44, 4-47, 4-48, 4-52, 4-53, 4-61, 4-62, 4-63, and 4-64

  • - pages 16, 25, 27, 46, 49, and 50 There is no change to the originally submitted no significant hazards considerations or commitments.

Entergy requests approval of the proposed amendment by February 1, 2007, in order to support insertion of the Metamic@ PIAs prior to the spring 2007 refueling outage. Once approved, the amendment shall be implemented within 60 days. Although this request is neither exigent nor emergency, your prompt review is requested.

If you have any questions or require additional information, please contact Dana Millar at 601-368-5445.

I declare under penalty of perjury that the foregoing is true and correct. Executed on October 4, 2006.

Sincerely, TAM/DM Attachments:

1. Analysis of Proposed Technical Specification Change
2. Proposed Technical Specification Changes (mark-up)
3. Proposed Technical Specification Changes (revised)
4. Changes to Technical Specification Bases Pages (For Information Only)
5. Spent Fuel Pool Racks Modifications with Poison Material Inserts in ANO Unit 1
6. Structural/Seismic Considerations for Addition of Metamic Panels to the Flux Traps of Two Spent Fuel Racks at ANO-1

1CAN100601 Page 3 of 3 cc:

Dr. Bruce S. Mallett Regional Administrator U. S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-8064 NRC Senior Resident Inspector Arkansas Nuclear One P. 0. Box 310 London, AR 72847 Arkansas Department of Health & Human Services Division of Health P.O. Box 1437 Slot H-30 Little Rock, AR 72203-1437 U. S. Nuclear Regulatory Commission Attn: Mr. Drew G. Holland MS O-7D1 Washington, DC 20555-0001

Attachment I ICAN100601 Analysis of Proposed Technical Specification Change to 1CAN100601 Page 3 of 23 Region 1 loading restrictions will be reflected in Table 3.7.15-1 as follows:

Region 1 - Minimum Burnup Requirements at Varying Initial U-235 Enrichment and Cooling Time (Notes 1 & 2)

Enrichment 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Cooling Time Minimum Burnup (GWD/MTU)

(Years)__

0 2.3 9.2 15.5 22.1 27.7 33.0 39.0 5

2.2 8.7 14.8 21.1 26.7 31.1 37.1 10 2.1 8.3 14.0 20.0 25.6 29.8 35.3 15 2.0 8.1 13.6 19.4 25.3 29.1 34.0 20 2.0 8.0 13.5 19.0 24.6 28.6 33.3 The criticality analysis also results in changes to the current loading restrictions imposed on the Region 2 racks and reflected in current Figure 3.7-15-1. The current figure will be deleted and new loading restrictions will be reflected in Table 3.7.15-1 for Region 2, as follows:

Region 2 - Minimum Burnup Requirements at Varying Initial U-235 Enrichment and Cooling Time (Notes 1 & 2)

Enrichment 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Cooling Time Minimum Burnup (GWD/MTU)

(Years)__

0 4.5 11.7 18.7 25.7 30.6 36.9 42.8 5

4.2 11.0 17.6 24.2 29.1 34.4 40.7 10 4.0 10.6 16.7 23.0 28.1 33.0 38.6 15 4.0 10.1 15.9 22.4 27.4 31.8 37.4 20 4.0 9.8 15.7 21.8 26.8 31.2 36.4 Note 1 associated with the two tables will be added stating:

"Linear interpolation between burnups for a given cooling time is allowed. However, linear interpolation between cooling times is not allowed, therefore the cooling time of a given assembly must be rounded down to the nearest cooling time."

Note 2, which is also associated with Regions 1 and 2, will be added to state the following:

"When it is necessary to store fuel assemblies in Region 1 or Region 2 that do not meet the burnup versus U-235 enrichment restrictions, fuel assemblies, including fresh or irradiated fuel assemblies with a maximum U-235 enrichment of 4.95 wt%, may be stored in a 2 x 2 checkerboard (i.e., 2 assemblies and 2 empty cells) arrangement."

A portion of the SFP racks in Region 2 will be modified by the installation of Metamic@ PIAs.

This will result in the creation of a new Region 3 that will include loading restrictions which will be reflected in Table 3.7.15-1 as follows:

to 1CAN100601 Page 5 of 23 SR 3.7.15.2 Verify Metamic properties are in accordance with, and In accordance with are maintained within the limits of, the Metamic I the Metamic Coupon Sampling Program.

Coupon Sampling I Program.

Technical Specifications 4.3.1, Criticality ANO-1 TS 4.3.1.1 a defines a maximum U-235 enrichment of 4.1 wt%. The proposed change will allow the maximum U-235 enrichment to be 4.95 wt%.

ANO-1 TS 4.3.1.1 b defines that keff (the effective neutron multiplication factor) will be maintained less than or equal to 0.95 if the spent fuel pool racks are fully flooded with unborated water. The criticality analysis, as allowed by 10 CFR 50.68, will credit boron (444 parts per million (ppm)) to assist in maintaining keff< 0.95 during normal operating conditions.

TS 4.3.1.1 c will be added, which will describe that a keff less than 1.0 will be maintained when the pool is flooded with unborated water. The addition of TS 4.3.1.1 c will result in the currently designated TSs 4.3.1.1 c, d, and e to be re-indexed as TSs 4.3.1.1 d, e, and f, respectively.

Current ANO-1 TS 4.3.1.1 d and TS 4.3.1.1 e define loading restrictions for Regions 1 and 2.

These will be modified in accordance with the changes proposed to TS 3.7.15 and as follows (current TS 4.3.1.1 d is reflected as "e" and current TS 4.3.1.1 e is reflected as "f' below):

e. New or partially spent fuel assemblies stored in accordance with Table 3.7.15-1 in the spent fuel pool storage racks;
f.

New or partially spent fuel assemblies with cooling times, U-235 enrichment or discharge burnup in the unacceptable range of Table 3.7.15-1 for fuel stored in either Region 1 or Region 2 may be stored in a 2 x 2 checkerboard configuration (i.e., 2 assemblies and 2 empty cells); and To describe the design features of Region 3, TS 4.3.1.1 g will be added and will state:

g. Neutron absorber (Metamic) installed between fuel assemblies in the Region 3 racks.

ANO-1 TS 4.3.1.2 a defines a maximum U-235 enrichment of 4.1 wt%. The proposed change will allow the maximum U-235 enrichment to be 4.95 wt%.

ANO-1 TS 4.3.1.2 e references Figure 4.3.1.2-1 which depicts locations in the fresh fuel storage racks in which fuel loading is prohibited. Based on the increase in fuel assembly U-235 enrichment from 4.1 wt% to a maximum U-235 enrichment of 4.95 wt%, two loading pattern configurations will be proposed, which will result in the addition of Figure 4.3.1.2-2. Figure 4.3.1.2-1 will depict the loading pattern associated with fuel assemblies with a maximum U-235 enrichment up to 4.95 wt% and Figure 4.3.1.2-2 will illustrate the loading configuration for fuel

Attachment I to 1CAN100601 Page 17 of 23 5.7 SFP Structural Integrity for Increased Loads from SFP Racks An evaluation of the SFP structural integrity for the effects of the increased loads from the SFP racks was performed. The evaluation demonstrated that the structural integrity of the pool structure is maintained.

6.0 REGULATORY ANALYSIS

6.1 Applicable Regulatory Requirements/Criteria The proposed changes have been evaluated to determine whether applicable regulations and requirements continue to be met. The applicable regulations and requirements used to support the proposed changes and reflection of their continued compliance are included in subsequent attachments to this letter.

Arkansas Nuclear One, Unit 1 (ANO-1) is currently exempt from the requirements of 10 CFR 70.24, Criticality accident requirements. The exemption was granted on October 6, 1998 (TAC NOS. MA1278 and MA1279). Upon approval of the proposed change, the exemption to 10 CFR 70.24 will no longer be required. ANO-1 will fully comply with 10 CFR 50.68 paragraph (b) as follows:

50.68(b)(1) - Plant procedures shall prohibit the handling and storage at any one time of more fuel assemblies than have been determined to be safely subcritical under the most adverse moderation conditions feasible by unborated water.

It has been determined that movement of only one fuel assembly at a time assures that subcriticality is maintained under the most adverse moderation conditions feasible by unborated water. ANO fuel handling procedures for the spent fuel pool (SFP) and reactor refueling bridges will exclusively prohibit the movement of more than one fuel assembly over the SFP or the refueling canal. Movement of a fuel assembly using the upender frame is allowed while the fuel handling bridges are moving fuel assemblies because it has been determined that for the worst case geometry the effective neutron multiplication factor (keff) is less than 0.95 at a 95% probability with a 95% confidence level. The fuel receipt procedure only allows one new fuel assembly to be moved at a time. Only one fuel assembly at a time is procedurally allowed to be moved into a dry fuel storage cask.

Storage of fuel assemblies is procedurally controlled to assure keff remains below 1.0, at a 95% probability, 95% confidence level, when flooded with unborated water. The storage patterns assure subcriticality under the most adverse moderation conditions by unborated water. The storage patterns will also insure reactivity will not exceed 0.95 at a 95%

probability with a 95% confidence level when credit is taken for 444 ppm boron during normal conditions. If a fuel assembly were to be misloaded, reactivity will not exceed 0.95 at a 95% probability with a 95% confidence level when credit is taken 889 ppm boron. For the overly conservative fuel drop accident that assumes the loss of all Metamic, a boron concentration of 1600 ppm ensures reactivity will not exceed 0.95 at a 95% probability with a 95% confidence level.

50.68(b)(2) - The estimated ratio of neutron production to neutron absorption and leakage (k-effective) of the fresh fuel in the fresh fuel storage racks shall be calculated assuming to 1CAN 100601 Page 18 of 23 the racks are loaded with fuel of the maximum fuel assembly reactivity and flooded with unborated water and must not exceed 0.95, at a 95 percent probability, 95 percent confidence level. This evaluation need not be performed if administrative controls and/or design features prevent such flooding or if fresh fuel storage racks are not used.

Criticality calculations have been performed on the new fuel vault fully loaded with B&W 15x15 fresh fuel assemblies and filled with the most reactive unborated water. The results of these calculations showed that reactivity did not exceed 0.95, at a 95% probability, 95%

confidence level.

50.68(b)(3) - If optimum moderation of fresh fuel in the fresh fuel storage racks occurs when the racks are assumed to be loaded with fuel of the maximum fuel assembly reactivity and filled with low density hydrogenous fluid, the k-effective corresponding to this optimum moderation must not exceed 0.98, at a 95 percent probability, 95 percent confidence level.

This evaluation need not be performed if administrative controls and/or design features prevent such moderation or if fresh fuel storage racks are not used.

Criticality calculations were performed on the new fuel vault fully loaded with B&W 15 x 15 fresh fuel assemblies and filled with the most reactive low density hydrogenous fluid. The results of these calculations showed that reactivity does not exceed 0.98, at a 95%

probability, 95% confidence level. Hydrogenous fluid are not used in the new fuel vault area and they would only be used in the most extreme cases where the use of fire water was not able to contain a fire in the new fuel vault area.

50.68(b)(4) - If no credit for soluble boron is taken, the k-effective of the spent fuel storage racks loaded with fuel of the maximum fuel assembly reactivity must not exceed 0.95, at a 95 percent probability, 95 percent confidence level, if flooded with unborated water. If credit is taken for soluble boron, the k-effective of the spent fuel storage racks loaded with fuel of the maximum fuel assembly reactivity must not exceed 0.95, at a 95 percent probability, 95 percent confidence level, if flooded with borated water, and the k-effective must remain below 1.0 (subcritical), at a 95 percent probability, 95 percent confidence level, if flooded with unborated water.

Soluble boron credit will be taken in the SFP storage racks. The criticality calculations included in the proposed change show that keff remains below 1.0, at a 95% probability, 95% confidence level, when flooded with unborated water. Reactivity (Ke,) will not exceed 0.95 at a 95% probability with a 95% confidence level when credit is taken for 444 ppm boron during normal operations. If a fuel assembly were to be misloaded, reactivity will not exceed 0.95 at a 95% probability with a 95% confidence level when credit is taken 889 ppm boron. For the overly conservative fuel drop accident that assumes the loss of all Metamic, a boron concentration of 1600 ppm ensures reactivity will not exceed 0.95 at a 95% probability with a 95% confidence level.

50.68(b)(5) - The quantity of SNM, other than nuclear fuel stored onsite, is less than the quantity necessary for a critical mass.

Any quantity of SNM (special nuclear material), other than nuclear fuel, that is received on site is tracked to ensure that the total quantity remains less than that needed to form a critical mass.

ICAN100601 Proposed Technical Specification Changes (mark-up)

Spent Fuel Pool Storage 3.7.15 Region 1 - Minimum Burnup Requirements at Varying Initial U-235 Enrichment and Cooling Time (Notes I & 2)

Enrichment 2.0 2.5 3.0 1

3.5 4.0 4.5 5.0 Cooling Time Minimum Burnup (GWDIMTU)

(Years)

Minimum Burnup

__VVD/MTU 0

2.3 9.2 15.5 22.1 27.7 33.0 39.0 5

2.2 8.7 14.8 21.1 26.7 31.1 37.1 10 2.1 8.3 14.0 20.0 25.6 29.8 35.3 15 2.0 8.1 13.6 19.4 25.3 29.1 34.0 20 2.0 8.0 13.5 19.0 24.6 28.6 33.3 Region 2 - Minimum Burnup Requirements at Varying Initial U-235 Enrichment and Cooling Time (Notes I & 2)

Enrichment 2.0 2.55 3.0 1

3.5 4.0 4.5 5.0 Cooling Time Minimum Burnup (GWD/MTU)

(Years)

Minimum Burnup

__WD/MTU_

0 4.5 11.7 18.7 25.7 30.6 36.9 42.8 5

4.2 11.0 17.6 24.2 29.1 34.4 40.7 10 4.0 10.6 16.7 23.0 28.1 33.0 38.6 15 4.0 10.1 15.9 22.4 27.4 31.8 37.4 20 4.0 9._8 15.7 21.8 26.8 31.2 36.4 Region 3 Loading Restrictions Unrestricted storage is allowed for fuel assemblies with an initial U-235 enrichment less than or equal to 4.35 wt%.

For fuel assemblies with an initial U-235 enrichment greater than 4.35 wt%, the burnup of at least one fuel assembly in each 2 x 2 section of storage cells is at least 20.1 GWD/MTU.

Note 1: Linear interoolation between burnuDs for a aiven coolina time is allowed. However.

linear interpolation between cooling times is not allowed, therefore the cooling time of a given assembly must be rounded down to the nearest coolinq time.

Note 2: When it is necessary to store fuel assemblies in Region 1 or Region 2 that do not meet the burnup versus U-235 enrichment restrictions, fuel assemblies, including fresh or irradiated fuel assemblies with a maximum U-235 enrichment of 4.95 wt%, may be stored in a 2 x 2 checkerboard (i.e., 2 assemblies and 2 empty cells) arrangement.

ANO-1 3.7.15-2 Amendment No. 21-5,

Fuel Storage 4.3 4.0 DESIGN FEATURES 4.3 Fuel Storage 4.3.1 Criticality 4.3.1.1 The spent fuel storage racks are designed and shall be maintained with:

a. Fuel assemblies having a maximum U-235 enrichment of 44-4.95 weight percent;
b. kef < 0.95 if fully flooded with 444 ppm of unborated water, which includes an allowance for uncertainties as described in Section 9.6.2.4.3 of the SAR;
c.

keff < 1.0 if fully flooded with unborated water, which includes an allowance for uncertainties as described in Section 9.6.2.4.3 of the SAR; Gd. A nominal 10.65 inch center to center distance between fuel assemblies placed in the storage racks; de. New or partially spent fuel assemblies with a discharge burnup in the "ac.eptable range" of-stored in accordance with Pgu-e-Table 3.7.15-1 allowed unreStricted storage in either-the spent fuel storage racks, Rogion or Region 2; and ef. New or partially spent fuel assemblies with cooling times, U-235 enrichment or a-discharge burnup in the -unacceptable range! of FigUe-Table 3.7.15-1 for fuel assemblies stored in Region 1 o.r Region 2 may be stored in a 2 x 2,-or-in checkerboard configuration (i.e., 2 assemblies and 2 empty cells): and-iA Region

a. Neutron absorber (Metamic) installed between fuel assemblies in the Region 3 racks.

4.3.1.2 The new fuel storage racks are designed and shall be maintained with:

a. Fuel assemblies having a maximum U-235 enrichment of 4-44.95 weight percent;
b. kef-< 0.95 under normal conditions, which includes an allowance for uncertainties as described in Section 9.6.2.4.3 of the SAR;
c. keff < 0.98 with optimum moderation, which includes an allowance for uncertainties as described in Section 9.6.2.4.3 of the SAR;
d. A nominal 21 inch center to center distance between fuel assemblies placed in the storage racks; and
e. Ton inteio*r* strage o.ls, Fuel assembly loading prohibited in interior stora-ge cells as shown in Figures 4.3.1.2-1 or 4.3.1.2-2, based on U-235 fuel enrichment., p-"ecled4 from use durin f uc" ANO-1 4.0-3 Amendment No. 21-5, ICAN100601 Proposed Technical Specification Changes (revised)

Spent Fuel Pool Storage 3.7.15 Table 3.7.15-1 Loading Restrictions for Spent Fuel Storage Racks Region I - Minimum Burnup Requirements at Varying Initial U-235 Enrichment and Cooling Time (Notes I & 2)

Enrichment 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Cooling Time Minimum Burnup (GWDIMTU)

(Years)

Minimum Burnup (GVVDMTU) 0 2.3 9.2 15.5 22.1 27.7 33.0 39.0 5

2.2 8.7 14.8 21.1 26.7 31.1 37.1 10 2.1 8.3 14.0 20.0 25.6 29.8 35.3 15 2.0 8.1 13.6 19.4 25.3 29.1 34.0 20 2.0 8.0 13.5 19.0 24.6 28.6 33.3 Region 2 - Minimum Burnup Requirements at Varying Initial U-235 Enrichment and Cooling Time (Notes I & 2)

Enrichment 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Cooling Time Minimum Burnup (GWD/MTU)

(Years)__

0 4.5 11.7 18.7 25.7 30.6 36.9 42.8 5

4.2 11.0 17.6 24.2 29.1 34.4 40.7 10 4.0 10.6 16.7 23.0 28.1 33.0 38.6 15 4.0 10.1 15.9 22.4 27.4 31.8 37.4 20 4.0 9.8 15.7 21.8 26.8 31.2 36.4 Region 3 Loading Restrictions Unrestricted storage is allowed for fuel assemblies with an initial U-235 enrichment less than or equal to 4.35 wt%.

For fuel assemblies with an initial U-235 enrichment greater than 4.35 wt%, the burnup of at least one fuel assembly in each 2 x 2 section of storage cells is at least 20.1 GWD/MTU.

Note 1: Linear interpolation between burnups for a given cooling time is allowed. However, linear interpolation between cooling times is not allowed, therefore the cooling time of a given assembly must be rounded down to the nearest cooling time.

Note 2: When it is necessary to store fuel assemblies in Region I or Region 2 that do not meet the burnup versus U-235 enrichment restrictions, fuel assemblies, including fresh or irradiated fuel assemblies with a maximum U-235 enrichment of 4.95 wt%, may be stored in a 2 x 2 checkerboard (i.e., 2 assemblies and 2 empty cells) arrangement.

ANO-1 3.7.15-2 Amendment No. 245,

Fuel Storage 4.3 4.0 DESIGN FEATURES 4.3 Fuel Storage 4.3.1 Criticality 4.3.1.1 The spent fuel storage racks are designed and shall be maintained with:

a. Fuel assemblies having a maximum U-235 enrichment of 4.95 weight percent;
b. kef -< 0.95 if fully flooded with 444 ppm of borated water, which includes an allowance for uncertainties as described in Section 9.6.2.4.3 of the SAR;
c. keff < 1.0 if fully flooded with unborated water, which includes an allowance for uncertainties as described in Section 9.6.2.4.3 of the SAR;
d. A nominal 10.65 inch center to center distance between fuel assemblies placed in the storage racks;
e. New or partially spent fuel assemblies stored in accordance with Table 3.7.15-1 in the spent fuel storage racks;
f.

New or partially spent fuel assemblies with cooling times, U-235 enrichment or discharge burnup in the unacceptable range of Table 3.7.15-1 for fuel assemblies stored in Region 1 or Region 2 may be stored in a 2 x 2 checkerboard configuration (i.e.,

2 assemblies and 2 empty cells); and

g. Neutron absorber (Metamic) installed between fuel assemblies in the Region 3 racks.

4.3.1.2 The new fuel storage racks are designed and shall be maintained with:

a. Fuel assemblies having a maximum U-235 enrichment of 4.95 weight percent;
b. kef < 0.95 under normal conditions, which includes an allowance for uncertainties as described in Section 9.6.2.4.3 of the SAR;
c. keff - 0.98 with optimum moderation, which includes an allowance for uncertainties as described in Section 9.6.2.4.3 of the SAR;
d. A nominal 21 inch center to center distance between fuel assemblies placed in the storage racks; and
e. Fuel assembly loading prohibited in interior storage cells as shown in Figures 4.3.1.2-1 or 4.3.1.2-2, based on U-235 fuel enrichment.

ANO-1 4.0-3 Amendment No. 245, ICAN100601 Changes to Technical Specification Bases Pages For Information Only

Spent Fuel Pool Boron Concentration B 3.7.14 B 3.7 PLANT SYSTEMS B 3.7.14 Spent Fuel Pool Boron Concentration BASES BACKGROUND As described in the Bases for LCO 3.7.15, "Spent Fuel Pool Storage," fuel assemblies are stored in the spent fuel pool racks in accordance with criteria based on initial U-235 enrichment, cooling time, and discharge burnup. Although the water in the spent fuel pool is normally borated to,.> 4600-2000 ppm, the criteria that limit the storage of a fuel assembly to specific rack locations are conservatively developed without-taking credit for a boron concentration of 444 Por in the spent fuel pool water.

The spent fuel storage pool is divided into two-three separate and distinct regions as shown in SAR Figure 9-53 which, for the purpose of criticality considerations, are considered as separate poolsinfinite arrays._ Rogion *,.s desig.od to accommodnte new fuel with a maximum enrichment of 4.1 Q5.0 - %4% U-1235, or spent (irradiated) fulel regardlos, of the di,, hargo-fu.. bu,,nup. Rogio;n I nd, 2 is reThe spent fuel pool racks are designed to accommodate fuel of various initial U-235 enrichments whioh-have accuGmulted minim'-buiups-within the acceptable domain according to F-igure-Table 3.7.15-1. Fuel assemblies not meeting the criteria of Fiqug-e-Table 3.7.15-1 shall be stored in accordance with Specification 4.3.1.1.ef. The criticalit' considr.tion, for the c~ack arc the same as required f-or Region I of the sepnt fuel pool storage locations.

The water in the spent fuel storage pool normally contains soluble boron, which results in large subcriticality margins under actual operating conditions. However, the NRC guidelines (10 CFR 50.68) specify that the limiting keff of 0-.951.0 be evaluated in the absence of soluble boron. The NRC guidelines also require that the limiting keff of 0.95 may be evaluated considering soluble boron or the absence of soluble boron. Hence, the design of both-the three regions is based on the use of u-borated water, which maintains each region in a subcritical condition during normal operation with the regions fully loaded. The double contingency principle discussed in ANSI N-16.1-1975 and the April 1978, NRC letter (Ref. 1) allows credit for soluble boron under other abnormal or accident conditions, since only a single accident need be considered at one time. Thus, for accident conditions, the presence of soluble boron in the spent fuel pool water can be assumed as a realistic condition. For example, accident scenarios are postulated which could potentially increase the reactivity and reduce the margin to criticality. To mitigate these postulated criticality related accidents, boron is dissolved in the pool water. Safe operation of the high density storage racks with no movement of assemblies may therefore be achieved by controlling the location of each assembly in accordance with LCO 3.7.15, "Spent Fuel Pool Storage." Prior to movement of an assembly, it is necessary to perform SR 3.7.15.1.

ANO-1 B 3.7.14-1

^A'mendment No. 215, Rev.

Spent Fuel Pool Storage B 3.7.15 B.3.7 PLANT SYSTEMS B 3.7.15 Spent Fuel Pool Storage BASES BACKGROUND The spent fuel assembly storage facility is designed to store either new (nonirradiated) nuclear fuel assemblies, or burned (irradiated) fuel assemblies in a vertical configuration underwater. The spent fuel pool is sized to store 968 fuel assemblies and is connected to a pit for loading shipping or dry fuel storage casks. The spent fuel storage cells are installed in parallel rows with center to center spacing of 10.65 inches in each direction.

The cask configuration is in accordance with the cask vendors VendeFS Certificate of Compliance.

The spent fuel storage pool is divided into two-three separate and distinct regions as shown in SAR Figure 9-53 which, for the purpose of criticality considerations, are considered as separate pools. Region 1 is dosignod to a..co..odato now fuel with a

'is*

g uel" bunmup,-and Region 2 is-are designed to accommodate fuel of various initial U-235 enrichments which have accumulated minimum burnups within the acceptable domain according to FTgue able 3.7.15-1. Fuel assemblies not meeting the G*ieF-iaacceptable range of FiqUF eTable 3.7.15-1 shall be stored in accordance with paragraph 4.3.1.1.e-f in SAR-TS_ Section 4.3, Fuel Storage. Region 3 is designed to accommodate new fuel with loading restrictions with a maximum initial fuel assembly enrichment of 4.35 or 4.95 wt% U-235 in accordance with Table 3.7.15-1. The supporting analysis included U-235 fuel enrichments of up to 5.0 wt% plus 0.05 wt% for uncertainties (Ref. 5). The rfiticality con;iderations for the cask are the same as-required for Regio I of the spent fuel pool storage locations.

APPLICABLE SAFETY ANALYSES Criticality of fuel assemblies in the spent fuel storage rack and casks is prevented by the design of the rack or cask, which limits fuel assembly interaction. This is done by fixing the Minimum separation between assemblies and inserting neutron poison between assemblies in Regi** ! 7Region 1 and-Region 2 controls fuel assembly interaction by fixing the minimum separation between assemblies and by setting U-235 enrichment, and burnup, and cooling time criterion to limit fissile materials. Region 3 controls fuel assembly interaction similar to Region 2 and utilizes Metamic poison panels. Thisis sufficient to mainta*n Aa keff of _ 0.95 for spent fuel of original U-235 enrichment of up to 4.4Gw95 wt% is accomplished by taking credit for boron (444 ppm).

k of < 1.0 is accomplished when no credit for boron is taken. However, fuel assemblies to be stored in the spent fuel pool RegioGn 2 '"ohic"h do9 net mneet enAr-ichme-nit" and bu.rup criterion must inadvertent fuel Assembly insertion into two adjacent storage foc~ations, Vacant space adjacent tG the faces of any fuel assembly which does not meet the Region 2 burnup G~iteiia.(u~nrest~iG ed) are physically blocked before any such fuel assembly is placed in Region 2 (Ref. 1). in addition, the area designated for checkerboard arrangement is ANO-1 B 3.7.15-1 Amendment No. 215, Rev. 43,

Spent Fuel Pool Storage B 3.7.15 Required Soluble Boron Concentrations for Accident Conditions TS 3.7.14 includes the requirement for great than 2000 ppm boron concentration to assure the fuel assemblies will be maintained in a subcritical array with K ff<* 0.95 in the event of a postulated drop accident. Analysis has shown that, during a postulated misplacement accident with the fuel stored within the limits of this specification, that a K ff < 0.95 will be maintained when the boron concentration is at or above 889 ppm.

The spent fuel pool storage satisfies Criterion 2 of 10 CFR 50.36 (Ref. 3).

ANO-1 B 3.7.15-1 Amcndmcnt No. 215, Rev. 4-3, 1CAN100601 Spent Fuel Pool Racks Modifications with Poison Material Inserts in ANO Unit I

Table 4.7.26 the following conclusions may be drawn regarding the reactivity effect of the interfaces:

  • In the Region 1 and Region 2 racks, a fresh fuel checkerboard and uniform spent fuel loading may be placed in the same rack. Calculations for the Region 2 racks show a slight increase in reactivity (Ak = +0.00 11) compared to the reference reactivity. This increase is accommodated by the margin in the calculations (max keff for Region 2 racks with spent fuel is 0.9950).

Therefore, this condition is allowed for Region 1 and Region 2 racks.

  • In Region 1 and Region 2 racks, if adjacent racks contain a checkerboard of fresh fuel assemblies, the checkerboard must be maintained across the gap, i.e., fresh fuel assemblies may not face each other across a gap.
  • In Region 3, uniform loading of fresh fuel at 4.35 wt% 235U may be combined with 3 of 4 loading in the same rack as long as a row of fresh and spent fuel in the 3 of 4 loading pattern faces the uniform loading of all fresh fuel at 4.35 wt% 213U.
  • If adjacent Region 3 racks contain different loading patterns (one rack contains all fresh fuel at 4.35 wt% and the other rack contains a 3 of 4 loading pattern), both fresh and spent fuel must be in the outer row of the rack containing the 3 of 4 pattern.
  • If adjacent Region 3 racks both contain 3.of 4 loading patterns, both racks may not have fresh fuel facing the other rack. Calculations with both Region 3 racks containing 3 of 4 patterns with all fresh fuel in the outer row of one rack and fresh and spent fuel in the outer row of the second rack shows a slight increase in reactivity (Ak = +0.0006) I compared to the reference case. This increase is accommodated by the margin in the calculations (max knff for Region 3 racks with 3 of 4 pattern is 0.9966). Therefore, this condition is allowed.
  • All interfaces between dissimilar racks (Region 1-Region 3 and Region 2-Region 3) do not result in an increase in the reactivity, and therefore, are permitted. Calculations were performed with a 3 of 4 loading pattern in the Region 3 racks, with fresh fuel (5.0 wt%

5U) in the outer row facing the other rack. This is bounding for the Region 3 rack containing all fresh fuel at 4.35 wt%, because the analyzed cases have higher reactivity fuel in the outer row of the rack.

4.2 METHODOLOGY The principal method for the criticality analysis of the high-density storage racks is the three-dimensional Monte Carlo code MCNP4a [4.3]. MCNP4a is a continuous energy three-dimensional Monte Carlo code developed at the Los Alamos National Laboratory. MCNP4a was selected because it has been used previously and verified for criticality analyses and has all of the necessary features for this analysis. MCNP4a calculations used continuous energy cross-section data based on ENDF/B-V and ENDF/B-VI.

Exceptions are two lumped fission products calculated by the CASMO-4 depletion code that do not have corresponding cross sections in MCNP4a. For these isotopes, the CASMO-4 cross sections are used in MCNP4a. This approach Holtec Report HI-2022867 4-3 Holtec Project 1196

has been validated [4.4] by showing that the cross sections result in the same reactivity effect in both CASMO-4 and MCNP4a.

Benchmark calculations, presented in Appendix 4A, indicate a bias of 0.0009 with an uncertainty of

+/- 0.0011 for MCNP4a, evaluated with a 95% probability at the 95% confidence level [4.1]. The calculations for this analysis utilize the same computer platform and cross-section libraries used for the benchmark calculations discussed in Appendix 4A.

The convergence of a Monte Carlo criticality problem is sensitive to the following parameters:

(1) number of histories per cycle, (2) the number of cycles skipped before averaging, (3) the total number of cycles and (4) the initial source distribution. The MCNP4a criticality output contains a great deal of useful information that may be used to determine the acceptability of the problem convergence.

This information has been used in parametric studies to develop appropriate values for the aforementioned criticality parameters to be used in storage rack criticality calculations. Based on these studies, a minimum of 10,000 histories were simulated per cycle, a minimum of 100 cycles were skipped before averaging, a minimum of 150 cycles were accumulated, and the initial source was specified as uniform over the fueled regions (assemblies). Further, the output was reviewed' to ensure that each calculation achieved acceptable convergence. These parameters represent an acceptable compromise between calculational precision and computational time.

Fuel depletion analyses during core operation were performed with CASMO-4 (using the 70-group cross-section library), a two-dimensional multigroup transport theory code based on capture probabilities [4.7-4.9]. CASMO-4 is used to determine the isotopic composition of the spent fuel.

In addition, the CASMO-4 calculations are restarted in the storage rack geometry, yielding the two-dimensional infinite multiplication factor (kjil) for the storage rack to determine the reactivity effect of fuel and rack tolerances, temperature variation, depletion uncertainty, and to perform various studies. For all calculations in the spent fuel pool racks, the Xe-135 concentration in the fuel is conservatively set to zero.

The evaluation performed to establish the bumup versus enrichment curve (loading curve) for the Region I and Region 2 racks, consists of MCNP4a calculations performed at selected enrichments between 2.0 wt% and 5.0 wt%, and for bumup values slightly above and below the expected loading curve. Points on the proposed loading curve are then calculated by linear interpolation for each enrichment, based on an appropriate target value (max keff = 0.9950) for the reactivity. Bumup versus enrichment values are calculated for cooling times of 0, 5, 10, 15 and 20 years. For the Region 3 racks the minimum required bumup for the single spent fuel assembly was determined with MCNP4a calculations, performed at an enrichment of 5.0 wt%

235U and at bumup values slightly above and below the expected required bumup. The minimum bumup was then calculated by linear interpolation, based on an appropriate target value (max klf

= 0.9966) for the reactivity.

The maximum kfr is determined from the MCNP4a calculated kffn the calculational bias, the temperature bias, and the applicable uncertainties and tolerances (bias uncertainty, calculational uncertainty, rack tolerances, fuel tolerances, depletion uncertainty) using the following formula:

Holtec Report HI-2022867 4-4 Holtee Project 1196

(e.g., depletion uncertainty and axial burnup distribution penalty) are not applicable to the Region 3 loading pattern with all fresh fuel of 4.35 wt% 235U. Results show that the maximum kefr of the Region 3 racks is less than 1.0 at a 95% probability at a 95% confidence level with no credit for soluble boron.

4.7.4.6 Determination of the Minimum Burnup for a Single Spent Assembly in the 3 of 4 Loading Pattern To establish a minimum required bumup for the loading pattern with 3 fresh fuel assemblies and one spent fuel assembly, calculations were performed with all assemblies having a maximum nominal initial enrichment of 5.0 wt% 235U and the single spent fuel assembly having bumup values slightly above and below the expected burnup value. The acceptable bumup for the single spent fuel assembly is then calculated by linear interpolation, based on an appropriate target value (max krr = 0.9966) for the reactivity. All calculations were performed at 0 cooling time; no credit was taken for additional cooling time for the single spent assembly as the reduction in burnup would be minimal. The minimum burnup is shown for 3 of 4 loading in Table 4.7.9.

4.7.4.7 Soluble Boron Concentration for Maximum keff of 0.95 Calculations crediting soluble boron in the spent fuel pool to ensure that the reactivity does not exceed 0.95 are also performed. Calculations are performed at enrichments of 4.35 wt% 235U and 5.0 wt% 235U for uniform loading of fresh fuel and a 3 of 4 configuration, respectively, at a soluble boron level of 400 ppm and 800 ppm. The minimum soluble boron requirement is determined by linear interpolation between soluble boron levels to achieve a target maximum kfr of 0.9450. In all cases, the maximum ker including all applicable biases and uncertainties is below the regulatory limit of 0.95. The results for each loading pattern in Region 3 is also listed in Table 4.7.10 and Table 4.7.12 for a 3 of 4 configuration and uniform loading of fresh fuel, respectively.

4.7.5 Abnormal and Accident Conditions for Region 1, 2 & 3 Racks The effects on reactivity of credible abnormal and accident conditions are examined in this section. This section identifies which of the credible abnormal or accident conditions will result in exceeding the limiting reactivity (kefr < 0.95). For those accidents or abnormal conditions that result in exceeding the limiting reactivity, a minimum soluble boron concentration is determined to ensure that kn" 2000 ppm), significantly reducing reactivity and further eliminating any criticality concern.

Holtec Report HI-2022867 4-29 Holtee Project 1196

Table 4.7.1 Summary of the Criticality Safety Analyses for Region 1 without Soluble Boron at 0 Years Cooling Time Design Basis Burnup at 5.0 wt% 235U 39.0 GWD/MTU I

Soluble Boron 0 ppm Uncertainties Bias Uncertainty (95%/95%)

+/- 0.0011 Calculational Statistics (95%/95%, 2.0xa)

+/- 0.0010 Fuel Eccentricity

+ 0.0142 Rack Tolerances

-0.0066 Fuel Tolerances

+/- 0.0074 Depletion Uncertainty

-0.0127

[

Statistical Combination of Uncertaintiestg9

+ 0.0215 I

Reference kefr (MCNP4a) 0.9638 I

Total Uncertainty (above) 0.0215 Temperature Bias 0.0085 Calculational Bias (see Appendix 4A) 0.0009 Maximum keff 0.9947 Regulatory Limiting keff 1.0000

[9] Square root of the sum of the squares.

Holtec Report HI-2022867 4-39 Holtec Project 1196

Table 4.7.2 Summary of the Criticality Safety Analyses for Region 1 with Soluble Boron at 0 Years Cooling Time Design Basis Bumup at 5.0 wt% "-U 39.0 GWD/MTU Soluble Boron 248 ppm Uncertainties Bias Uncertainty (95%/95%)

+/- 0.0011 Calculational Statistics (95%/95%, 2.0x;)

+/- 0.0011 Fuel Eccentricity

+ 0.0142 Rack Tolerances

-0.0066 Fuel Tolerances

+/- 0.0074 Depletion Uncertainty

- 0.0127 Statistical Combination of Uncertaintiesti0

+/-:0.0215 Reference Irr (MCNP4a) 0.9141 Total Uncertainty (above) 0.0215 Temperature Bias 0.0085 Calculational Bias (see Appendix 4A) 0.0009 Maximum keff 0.9450 Regulatory Limiting kerr 0.9500

[1o0 Square root of the sum of the squares.

Holtec Report HI-2022867 4-40 Holtec Project 1 196 Holtec Report HI-2022867 4-40 Holtec Project 1196

Table 4.7.5 Summary of the Criticality Safety Analyses for Region 2 without Soluble Boron at 0 Years Cooling Time Design Basis Burnup at 5.0 wt% 235U 42.8 GWD/MTU Soluble Boron 0 ppm Uncertainties Bias Uncertainty (95%/95%)

+/- 0.0011 Calculational Statistics (95%/95%, 2.0x;)

+/- 0.0011 Fuel Eccentricity

+0.0168 Rack Tolerances

-0.0039 Fuel Tolerances

+/- 0.0073 Depletion Uncertainty

+ 0.0139 Statistical Combination of Uncertainties 13]

+ 0.0234 I

Reference klr (MCNP4a) 0.9613 Total Uncertainty (above) 0.0234 I

Temperature Bias 0.0093 Calculational Bias (see Appendix 4A) 0.0009 Maximum kerr 0.9949 Regulatory Limiting kerr 1.0000 1131 Square root of the sum of the squares.

Holtec Report HI-2022867 4-43 Hohec Project 1196 Holtec Report HI-2022867 4-43 Holtec Project 1196

Table 4.7.6 Summary of the Criticality Safety Analyses for Region 2 with Soluble Boron at 0 Years Cooling Time Design Basis Burnup at 5.0 wt% 235U 42.8 GWD/MTU Soluble Boron 236 ppm[1 4J Uncertainties Bias Uncertainty (95%/95%)

+/- 0.0011 Calculational Statistics (95%/95%, 2.Oxa)

+/- 0.0012 Fuel Eccentricity

+0.0168 Rack Tolerances

. 0.0039 Fuel Tolerances

+/- 0.0073 Depletion Uncertainty

. 0.0139 Statistical Combination of Uncertainties115 J

+ 0.0234 Reference kenr (MCNP4a) 0.9114 Total Uncertainty (above) 0.0234 Temperature Bias 0.0093 Calculational Bias (see Appendix 4A) 0.0009 Maximum kenf 0.9450 Regulatory Limiting kerr 0.9500

[14] Calculations performed for 5.0 wt% fuel with a bumup of 36.4 GWD/MTU at 20 years cooling time, resulted in a slightly higher soluble boron requirement of 237ppm

[51 Square root of the sum of the squares.

Holtec Report HI-2022867 4.44 Holtec Project 1196 Holtec Report HI-2022867 4-44 Holtec Project 1196

Table 4.7.9 Summary of the Criticality Safety Analyses for Region 3 without Soluble Boron for a 2x2 Checkerboard of 3 Fresh Fuel Assemblies and 1 Spent Fuel Assembly at 0 Years Cooling Time Design Basis Burnup for Single (5.0 wt%) Spent 20.1 GWD/MTU Assembly Soluble Boron 0 ppm Uncertainties Bias Uncertainty (95%/95%)

+ 0.0011 Calculational Statistics (95%/95%, 2.0xa)

+/- 0.0014 Fuel Eccentricity Negative Rack Tolerances

+ 0.0060 Fuel Tolerances

-0.0053 Depletion Uncertainty

+ 0.0012 Statistical Combination of Uncertaintiest'8 1

++/-0.0082 Reference kerr (MCNP4a) 0.9858 Total Uncertainty (above) 0.0082 Temperature Bias 0.0017 Calculational Bias (see Appendix 4A) 0.0009 Maximum kerr 0.9966 Regulatory Limiting ken 1.0000

[ISj Square root of the sum of the squares.

Holtec Report HI-2022867 4-47 Holtec Project 1196 Holtec Report HI-2022867 4-47 Holtec Project 1196

Table 4.7.10 Summary of the Criticality Safety Analyses for Region 3 with Soluble Boron for a 2x2 Checkerboard of 3 Fresh Fuel Assemblies and 1 Spent Fuel Assembly at 0 Years Cooling Time Design Basis Bumup for Single (5.0 wt%) Spent 20.1 GWD/MTU Assembly Soluble Boron 444 ppm Uncertainties Bias Uncertainty (95%/95%)

+/- 0.0011 Calculational Statistics (95%/95%, 2.0xa)

+/- 0.0012 Fuel Eccentricity Negative Rack Tolerances

+/- 0.0060 Fuel Tolerances

+/-0.0053 Depletion Uncertainty

-0.0012 Statistical Combination of Uncertaintiestigj

+ 0.0082 Reference ker (MCNP4a) 0.9342 Total Uncertainty (above) 0.0082 Temperature Bias 0.0017 Calculational Bias (see Appendix 4A) 0.0009 Maximum kff 0.9450 Regulatory Limiting keg 0.9500

[19] Square root of the sum of the squares.

Holtec Report HI.2022867 4-48 Holtec Project 1196 Holtec Report HI-2022867 4-48 Holtec Project 1196

Table 4.7.14122]

Minimum Burnup versus Enrichment Values for Region 1 Racks with Spent Fuel Enrichment 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Cooling Time Minimum Bumup (GWD/MTU) 0 2.3 9.2 15.5 22.1 27.7 33.0 39.0 5

2.2 8.7 14.8 21.1 26.7 31.1 37.1 10 2.1 8.3 14.0 20.0 25.6 29.8 35.3 15 2.0 8.1 13.6 19.4 25.3 29.1 34.0 20 2.0 8.0 13.5 19.0 24.6 28.6 33.3 122 Linear interpolation between bumups for a given cooling time is allowed. However, linear interpolation between cooling times is not allowed, therefore the cooling time of a given assembly must be rounded down to the nearest cooling time.

Holtec Report HI-2022867 4-52 Holtee: Project I196*

Table 4.7.15123]

Minimum Burnup versus Enrichment Values for Region 2 Racks with Spent Fuel Enrichment 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Cooling Time Minimum Bumup (GWD/MTU) 0 4.5 11.7 18.7 25.7 30.6 36.9 42.8 5

4.2 11.0 17.6 24.2 29.1 34.4 40.7 10 4.0 10.6 16.7 23.0 28.1 33.0 38.6 15 4.0 10.1 15.9 22.4 27.4 31.8 37.4 20 4.0 9.8 15.7 21.8 26.8 31.2 36A 1231 Linear interpolation between bumups for a given cooling time is allowed. However, linear interpolation between cooling times is not allowed, therefore the cooling time of a given assembly must be rounded down to the nearest cooling time.

Holtec: Report HI-2022867 4-53 Holtec Project 1196

Table 4.7.23 Region 1 Accident Conditions Abnormal/Accident Condition Soluble Boron Requirement Abnormal Temperature - Spent Fuel 326 ppm Abnormal Temperature - Fresh Fuel 209 ppm Dropped Assembly - Horizontal Negligible Dropped Assembly - Vertical Negligible Misloaded Assembly - Spent Fuel 521 ppm Misloaded Assembly - Fresh Fuel 804 ppm Mislocated Assembly - Spent Fuel 493 ppm Mislocated Assembly - Fresh Fuel 889 ppm Maximum 889 ppm I

II Holtec Report HI-2022867 4.61 Holtec Project 1196 Holtec Report HI-2022867 4-61 Holtec Project 1196

Table 4.7.24 Region 2 Accident Conditions Abnormal/Accident Condition Soluble Boron Requirement Abnormal Temperature - Spent Fuel 332 ppm Abnormal Temperature - Fresh Fuel 278 ppm Dropped Assembly - Horizontal Negligible Dropped Assembly - Vertical Negligible Misloaded Assembly-Spent Fuel 551 ppm Misloaded Assembly - Fresh Fuel 867 ppm Mislocated Assembly - Spent Fuel 480 ppm Mislocated Assembly - Fresh Fuel 875 ppm Maximum 875 ppm I

I Holtec Report HI-2022867 4-62 Holtec Project 1196 Holtec Report HI-2022867 4-62 Holtec Project 1196

Table 4.7.25 Region 3 Accident Conditions Abnormal/Accident Condition Soluble Boron Requirement Abnormal Temperature Negative Dropped Assembly - Horizontal Negligible Dropped Assembly - Vertical Negligible Misloaded Assembly-3 of 4 Pattern 672 ppm Mislocated Assembly - 3 of 4 Pattern 843 ppm Maximum 843 ppm Holtec Report 1-11-2022867 4-63 Holtec Project 1196 Holtec Report HI-2022867 4-63 Holtec Project 1196

Table 4.7.26 Interface Calculations Interface Calculation Figure #

Reactivity Reference Delta k Acceptable?

Reactivity (k,,,,1 )

Region ito Region I with fresh fuel checkerboard in each 4.7.1 0.9352 0.9329

+0.0023 N

rack. Fresh fuel assemblies facing in adjacent racks.

4.7.1,0.9352 0.9329_+0.0023_N Region I - Checkerboard and Spent Fuel in same rack.

4.7.2 0.9596 0.9638

-0.0042 Y

Region 2 to Region 2 with fresh fuel checkerboard in each 473 0.9454 0.9431

+0.0023 N

rack. Fresh fuel assemblies facing in adjacent racks.

4.7.3 0.9454_0.9431

+0.0023 N

Region 2 - Checkerboard and Spent Fuel in same rack.

4.7.4 0.9673 0.9662

+0.0011 Y

Region 3 to Region 3 with no Metamic Panel in the gap. 3 of 4 pattern with fresh fuel at 5.0 wt% 35U facing each 4.7.5 0.9908 0.9858

+0.0050 N

other in both racks.

Region 3 to Region 3 with no Metamic Panel in the gap. 3 of 4 pattern with fresh fuel at 5.0 wt% 23U in one rack 4.7.6 0.9864 0.9858

+0.0006 Y

facing fresh and spent fuel in other rack across gap.

Region 3 to Region 3 with no Metamic Panel in the gap.

All fresh fuel at 4.35 wt% 235U in one rack, 3 of 4 pattern 4.7.7 0.9890 0.9860

+0.0030 N

with fresh fuel facing gap in other rack.

Region 3 to Region 3 with no Metamic Panel in the gap.

All fresh fuel at 4.35 wt% 23SU in one rack, 3 of 4 pattern 4.7.8 0.9838 0.9860

-0.0022 Y

with fresh and spent fuel facing gap in other rack.

Region I to Region 3, Fresh Fuel Checkerboard in Region 4.7.9 0.9825 0.9858

-0.0033 Y

I1 rack, 3 of 4 pattern in Region 3 rack.

4.7.9 0.9825_0.9858_-0.0033__

Region 1 to Region 3, Spent Fuel in Region I rack, 3 of 4 4.7.10 0.9822 0.9858

-0.0036 Y

pattern in Region 3 rack.

Region 2 to Region 3, Fresh Fuel Checkerboard in Region 4.7.11 0.9832 0.9858

-0.0026 Y

2 rack, 3 of 4 pattern in Region 3 rack.

Region 2 to Region 3, Spent Fuel in Region 2 rack, 3 of 4 4.7.12 0.9834 0.9858

-0.0024 Y

pattern in Region 3 rack.

4..20.840.88-002_

Region 3 - 3 of 4 and Fresh Fuel 4.35 wt% 235U in same 4.7.13 0.9881 0.9860

+0.0021 N

rack. All fresh 5.0 wt% facing all fresh 4.35 wt%

Region 3 - 3 of 4 and Fresh Fuel 4.35 wt% 23 0U in same y

rack. Fresh and spent 5.0 wt% facing all fresh 4.35 Wt%

Holtee Report HI-2022867 4-64 Holtec Project 1196 1CAN 00601 Structural/Seismic Considerations for Addition of Metamic Panels to the Flux Traps of Two Spent Fuel Racks at ANO-1

Stevenson & Associates Report 06Q3571.01-01 Friction at the support to pool floor interface is modeled by the linear friction springs with stiffness Kf up to the limiting lateral load gtN, where N is the current compression load at the interface between support and liner. At every time-step during time history analysis, the current value of N (either zero, if the pedestal has lifted off the floor, or a restraining force) is computed.

The modeling of the effective compression stiffness with the gap element of stiffness K, includes the pedestal stiffness and local stiffness of the underlying pool slab.

4.8 Poison Insert Modeling The metamic poison inserts consist of two nominal 7" wide x 155" long by 0.1" thick metamic panels per flux trap. Each metamic panel is enclosed in a formed 26 gage sheet metal channel.

The channels are nominally 7.12" deep with.43" flanges x 155" long. The metamic panels are held in the channels by a 4" long x 26 gage sheet metal channel-shaped band at the top and bottom, and four 6" long x 26 gage sheet metal channel-shaped bands between the 4" bands, spaced at about 30" to 32" center to center. These bands are spot welded to the outside channel "flanges" with two spot welds on each side. The inserts are detailed on References 14 and 15.

The design of the metamic inserts has evolved over time to the present configuration where the sheet metal channels with the metamic panels are now held (front to front) at a nominal 1.20" apart, measured out to out between the backs of the channel sections. They are held by ten to fourteen pairs of 0.075" thick x 0.95" wide x 4" long plates, spaced 7" to 20" welded to the channel flanges along the length, plus a pair of 0.90" wide x 4" long plates (0.02" thick at the bottom and 0.075" thick at the top) welded to the channel flanges at the top and bottom.

There are four 22 Gage sheet metal formed bands described as horizontal supports, between the two insert halves along with four pairs of corresponding 22 Gage sheet metal formed bands described as vertical supports.

The original purpose of these "supports" was to hold the opposing channel/panel sections together during shipping and insertion into the flux traps. Now that the design is such that the panel/channel sections are fixed by the plates on the flanges, these "supports" no longer have any function. They are classified as non-safety related and provide no structural support, and assumed no interference. The total mass/weight of these supports is very small (-0. 1 lb each). In the rack models, the inserts are modeled with more than double their actual weight. Hence, the horizontal and vertical supports are not considered explicitly.

There are also three sets of wedge blocks made from %-"

plate, with one set at the top, one at the bottom, and the other located about 2/5 the distance from the top, between the other two. These wedge blocks were originally designed to hold the insert halves apart and against the inside walls of the flux traps after insertion into the flux traps. Since the panels with their wrapper channels are now fixed by the added plates at a nominal 1.20" outside width and the opposing panel assemblies are now offset vertically 113/16", the wedge blocks likely are not in contact with each other, and hence cannot be counted on to provide any structural support. They are included for mass/weight effects only in the insert model, with mass distribution varied proportionately to account for their locations in the rack models.

To determine equivalent structural properties for the metamic insert panels for inclusion in the rack models, a model of a typical metamic panel was developed using shell elements.

Page 16 of 50

Stevenson & Associates Report 06Q3571.01-01 and subscripts x and y reflect the particular bending plane.

Combined flexure and compression (or tension) on a net section:

f.

+ fL. +fby

<1. 0 o.6SY FbX bY The above requirements are to be met for both direct tension and compression.

7.2.6 Bearing Allowable Stress - OBE Allowable Bearing Stress from Section NF-3226.1 of the ASME Code [16]:

Fb = Sy 27,500 psi 7.2.7 Weld Allowable Stress or Force (By Analysis and Test) - OBE Allowable maximum shear stress on the net section of a weld is given by:

F,, = 0.3 Su (on the weld material) or

& = 0.4 Sy (on the base metal material in shear)

& = 0.6 Sy (on the base metal material in tension) where S,, is the weld material ultimate strength at temperature and Sy is the base metal yield strength at temperature. Per Ref. [9] the weld material used is an E80 electrode with an S,, = 80 ksi.

For fillet weld legs in contact with base metal, the shear stress on the gross section is limited to 0.4Sy, where Sy is the base material yield strength at temperature.

Therefore the allowable weld stress is:

& = 0.3 S, =.3

  • 80 ksi = 24 ksi (on the weld material)

Fw = 0.4 Syv = 0.4

  • 27,500 psi = 11,000 psi (on the base metal material in shear)

F, = 0.6 Sy = 0.6

  • 27,500 psi = 16,500 psi (on the base metal material in tension)

The spot weld and fillet weld allowables were determined by test, with the spot weld capacity found to be lower than that for the fillet welds. Capacity for both welds was then taken as:

F = T.L. * (/SId Where: T.L. is the mean ultimate capacity test results. From Ref. [19] the mean of the 15 test samples for the spot weld = 680 lb (rounded to the nearest 10 lb)

S = ASME Code Allowable Stress S = 17.2 ksi from Ref. [ 18] (Note that failure of the test was a base metal failure, therefore, S, is the base metal allowable stress.)

Page 25 of 50

Stevenson & Associates Report 06Q3571.01-01 7.3.5 Combined Bending and Tension or Compression Allowable Stress - DBE Combined bending and compression on a net section satisfies:

f.

+ C"fbX + CflyfbY < 1 0.667

  • F, D.Fb, DyFbY Where all of the terms have been defined in Subsections 7.2.5 and 7.3.2.

Combined flexure and compression (or tension) on a net section:

f.

+

fA,+y < 1.0 0.667"F, FbX Fby Where 0.667

  • Fe is limited to the tension allowable of 28,500 psi. The above requirements are to be met for both direct tension and compression.

7.3.6 Bearing Allowable Stress - DBE Per Section F-1334.10 [16], Bearing Stress need not be evaluated for loads when Limit D Service Limits are specified.

7.3.7 Weld Allowable Stress and Force (By Test) - DBE For welds, the allowable maximum weld stress is not specified in Appendix F of the ASME Code. An appropriate limit for weld throat stress is conservatively set here as:

Fw = 0.3 S,, x factor (on the weld material)

& = 0.4 Sy x factor (on the base metal in shear)

F, = 0.6 S,, x factor (on the base metal in tension) where:

factor = (Level D shear stress limit) / (Level A shear stress limit) 17,100/11,000 = 1.55 and S, and Sy were defined in Section 7.2.7 Therefore the allowable weld stress is:

F= 0.3 S,, x factor 1.55*0.3

  • 80 ksi = 37.2 ksi (weld material)

& = 0.4 Sy x factor = 1.55

  • 0.4
  • 23,750 psi = 14,725 psi (base metal in shear)

F, = 0.6 S. x factor = 1.55 *0.6

  • 23,750 psi = 22,088 psi (base metal in tension)

The spot weld and fillet weld allowable loads were determined by test from F-1332.7 of Appendix F [16] and were taken (using the lower OBE allowable load for the spot welds) as:

F& = 0.7 *T.L. * (AIS,,*)

Page 27 of 50

Stevenson & Associates Report 06Q3571.01-01 10.0 Conclusions The overall design objectives of the spent fuel storage pool at ANO Unit I have been shown to meet the various Regulatory Guides, the Standard Review Plan, and industry standards. The structural adequacy of the SFP maximum density spent fuel racks at ANO Unit 1 with the new poison inserts have been evaluated using the appropriate regulatory and design standards.

Postulated loadings for normal, seismic, and accident conditions at the ANO Unit I site were considered in this analysis and evaluation. The design adequacy of the racks and the poison inserts has been confirmed with analyses that were performed in compliance with the USNRC Standard Review Plan [1], the USNRC Office of Technology Position Paper [2], Lawrence Livermore Report UCRL52342 [3] and ANO Specification APL-C-502 [4]. All applicable displacement and stress acceptance criteria have been met for the racks and the new poison inserts, as summarized for the OBE and DBE in Tables 10.1, 10.2 and 10.3 below. Results for the Pool Structure Analysis are summarized in Table 9.1 above.

Table 10.1 -

Summary of Stre~ Re~uIt~ for ORE Load Case Component Stress D + L + E Type Applied Stress Allowable Stress Stress (psi)

(psi)

Interaction Cell Axial+Bending 10209.4 16500 0.619 Buckling 5485.4 7612 0.721 Wrapper Welds Shear 8847 11000 0.804 Cell Seam Welds Shear 18786 24000 0.783 Cell to Cell Welds at Top Shear 12259 24000 0.511 at Bottom Shear 19681 24000 0.820 Cell to Base Plate Tension 12790 16500 0.775 Welds Support Pad Axial 9322.9 16500 0.565 Shear 2115.9 11000 0.192 Bearing 8274.2 27500 0.301 Shear 8128.5 11000 0.739 Threads Support Plate Axial 330.1 16500 0.020 Shear 2543.9 11000 0.231 Metamic Insert Enclosure Channel Axial + Bending 44.3 151116500 0.261 Buckling Axial Compression 94.2 lb 360 lb 0.262 Spot Welds Shear Force 170 lb I

Note: 1) Shear force on the spot welds are insignificant from seismic loading.

Page 46 of 50

Stevenson & Associates Report 06Q3571.01-01 11.0 References

[1]

USNRC NUREG-0800, Standard Review Plan, June 1987.

[2]

(USNRC Office of Technology) "OT Position for Review and Acceptance of Spent Fuel Storage and Handling Applications," dated April 14,1978, and January 18, 1979 amendment thereto.

[3]

UCRL52342, "Effective Mass and Damping of Submerged Structures," Lawrence Livermore National Laboratory, April 1, 1978.

[4]

ANO Technical Specification APL-C-502, "Technical Specifications for Earthquake Resistance Design of Structures and/or Components Located in the Auxiliary Building for the Arkansas Nuclear One Unit 1 Power Plant," Rev. 2, 4-22-87.

[5]

Stevenson & Associates Calculation ANO-ER-02-051, "Seismic Re-qualification of the Arkansas Nuclear One Unit 1 Spent Fuel Racks," Rev. 1, June 28, 2006.

[6]

SOLVIA, Finite Element System, Version 99, Solvia Engineering, AB, Sweden, 1987-2001.

[7].

SOLVIA, Finite Element System, Version 03, Solvia Engineering, AB, Sweden, 1987-2006.

[8]

Westinghouse Drawing 1-W62A-017(l)-0

[9]

Calculation 91E-0079-01, Revision 1, "Design Report for Spent Fuel Storage Racks for AP&L Co.," 9-20-96 (analysis performed in 1982).

[10]

Levy, S. and Wilkinson, J.P.D., "The Component Element Method in Dynamics with Application to Earthquake and Vehicle Engineering," McGraw Hill, 1976.

[11]

ASCE Standard 4-98, "Seismic Analysis of Safety Related Nuclear Structures and Commentary," American Society of Civil Engineers, Copyright 2000.

[12]

Stevenson & Associates Report, "Independent Evaluation of Seismic Response of Spent Fuel Storage Racks Currently Being Procured for Salem Nuclear Power Plant," Dec. 1, 1993.

[13]

NUREG/CR-5912, BNL-NUREG-52335, "Review of the Technical Basis and Verification of Current Analysis Methods Used to Predict Seismic Response of Spent Fuel Storage Racks," Brookhaven National Laboratory, October 1992.

[14]

Holtec International Drawing 4127, "Fabrication Drawing of Metamic Inserts for ANO-1 Spent Fuel Racks," Revision 13, 9/28/06.

[15]

Holtec International Drawing 3917, "Metamic Inserts and Fuel Leadins for Spent Fuel Racks," Revision 11,9/28/06.

Page 49 of 50

Stevenson & Associates Report 06Q3571.01-01

[16]

ASME Boiler & Pressure Vessel Code,Section III, Subsection NF, 1980, through Winter 1981 Addendum.

[17]

Stevenson and Associates, Program THSPEC - Verification and User's Manual for Computer Code THSPEC.

[18]

ASME Boiler & Pressure Vessel Code,Section III, Appendices, 1980, through Winter 1981 Addendum.

[19]

Stork Herron Testing Labs, Specimen Load Tests, Dec. 18, 2003.

[20]

Chun, R., Witte, M. and Schwartz, M., "Dynamic Impact Effects on Spent Fuel Assemblies," UCID-21246, Lawrence Livermore National Laboratory, October 1987.

[21]

ACI 349-85, Code Requirements for Nuclear Safety Related Concrete Structures, American Concrete Institute, Detroit, Michigan, 1985.

[22]

ACI 318-95, Building Code Requirements for Structural Concrete, American Concrete Institute, Detroit, Michigan, 1995.

[23]

Entergy letter to the NRC dated April 2, 2003. "License Amendment Request to Modify the Fuel Assembly Enrichment, the Spent Fuel Pool (SFP) Boron Concentration Technical Specification (TS) 3.7.14, the Loading Restrictions in the SFP in TS 3.7.15, and to Modify the Fuel Storage Design Features in TS 4.3."

[24]

Entergy letter to Stevenson & Associates - ANO-2003-00144, dated Dec. 8, 2003,

Subject:

"Spent fuel Pool Inputs Required for the Unit 1 Rack Seismic Analysis."

[25]

ANO-1 SFP Rack Design Inputs, Design Input Record, Document Number ANO-2005-00252, 11/16/2005.

[26]

Stevenson & Associates Calculation ANO-ER-02-010, "Review of Structural Analysis of the Arkansas Nuclear One Unit I Spent Fuel Pool For Revised Fuel Rack Loads," Rev. 0, June 28, 2006.

[27]

Chajes, A., "Principles of Structural Stability Theory," Prentice-Hall, New Jersey, 1974.

[28]

ANO-1 SFP Rack Design Inputs, Design Input Record, Document Number ANO-2005-00252, 11/16/2005.

[29]

ANO-! SFP Rack Design Inputs, Design Input Record, Document Number lHoltec Drawing 3917 and 4127, 9/29/2006, Rev. 1.

Page 50 of 50