RCS Leakage Detection Instrumentation 3.4.15 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.15 RCS Leakage Detection Instrumentation LCO 3.4.15 APPLICABILITY:

The following RCS leakage detection instrumentation shall be OPERABLE:

a.

The containment sump level and flow monitoring system;

b.

One containment atmosphere particulate radioactivity monitor; and

c.

The containment cooler condensate monitoring system.

MODES 1, 2, 3, and 4.

I ACTIONS COMPLETION CONDITION REQUIRED ACTION TIME TIME A.

Required containment sump A.1 NOTE------

level and flow monitoring Not required until system inoperable.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after establishment of steady state operation.

Perform SR 3.4.13.1.

Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> AND A.2 Restore required 30 days containment sump level and flow monitoring system to OPERABLE status.

(continued)

CALLAWAY PLANT 3.4-36 Amendment No. 175

RCS Leakage Detection Instrumentation 3.4.15 ACTIONS (continued)

I COMPLETION CONDITION REQUIRED ACTION TIME TIME B.

Required containment atmosphere particulate radioactivity monitor inoperable.

B.1.1 OR B.1.2 Analyze samples of the containment atmosphere.

NOTE------

Not required until 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after establishment of steady state operation.

Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Perform SR 3.4.13.1.

AND B.2.1 Restore required containment atmosphere particulate radioactivity monitor to OPERABLE status.

30 days I

OR I.

B.2.2 Verify containment air cooler condensate monitoring system is OPERABLE.

30 days tcontinueac)

CALLAWAY PLANT 3.4-37 Amendment No. 175

RCS Leakage Detection Instrumentation 3.4.15 ACTIONS (continued)

COMPLETION CONDITION REQUIRED ACTION TIME TIME C.

Required containment C.1 Perform SR 3.4.15.1.

Once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> cooler condensate monitoring system OR inoperable.

C.2 NOTE------

Not required until 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after establishment of steady state operation.

Perform SR 3.4.13.1.

Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> D.

Required containment D.1 Restore required 30 days atmosphere particulate containment atmosphere radioactivity monitor particulate radioactivity inoperable.

monitor to OPERABLE status.

AND OR Required containment cooler condensate D.2 Restore required 30 days monitoring system containment cooler inoperable, condensate monitoring system to OPERABLE status.

E.

Required Action and E.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.

AND E.2 Be in MODE 5.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> F..

All required monitoring F.1 Enter LCO 3.0.3.

Immediately methods inoperable.

I CALLAWAY PLANT 3.4-38 Amendment No. 175

RCS Leakage Detection Instrumentation 3.4.15 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.4.15.1 Perform CHANNEL CHECK of the required 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> containment atmosphere particulate radioactivity monitor.

SR 3.4.15.2 Perform COT of the required containment 92 days atmosphere particulate radioactivity monitor.

SR 3.4.15.3 Perform CHANNEL CALIBRATION of the required 18 months containment sump level and flow monitoring system.

SR 3.4.15.4 Perform CHANNEL CALIBRATION of the required 18 months containment atmosphere particulate radioactivity monitor.

SR 3.4.15.5 Perform CHANNEL CALIBRATION of the required 18 months containment cooler condensate monitoring system.

II CALLAWAY PLANT 3.4-39 Amendment No. 175