ML062680415

From kanterella
Jump to navigation Jump to search

Tech Spec Pages to Correction to Amendment 223 Regarding Steam Generator Tube Integrity
ML062680415
Person / Time
Site: Point Beach  NextEra Energy icon.png
Issue date: 09/18/2006
From:
NRC/NRR/ADRO/DORL/LPLIII-1
To:
F. Lyon LPLE X2296
Shared Package
ML062440008 List:
References
TAC MD0194, TAC MD0195
Download: ML062680415 (2)


Text

SG Tube Integrity 3.4.17 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.17 Steam Generator (SG) Tube Integrity LCO 3.4.17 SG tube integrity shall be maintained.

AND All SG tubes satisfying the tube repair criteria shall be plugged in accordance with the Steam Generator Program.

APPLICABILITY:

MODES 1, 2, 3, and 4.

ACTIONS NOTE---

Separate Condition entry is allowed for each SG tube.

CONDITION REQUIRED ACTION COMPLETION TIME A. One or more SG tubes A.1 Verify tube integrity of the 7 days satisfying the tube repair affected tube(s) is criteria and not plugged maintained until the next in accordance with the refueling outage or SG Steam Generator tube inspection.

Program.

AND A.2 Plug the affected tube(s) in Prior to entering accordance with the Steam MODE 4 following the Generator Program.

next refueling outage or SG tube inspection B. Required Action and B.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time of Condition A not AND met.

B.2 Be in MODE 5.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> OR SG tube integrity not maintained.

Point Beach 3.4.17-1 Unit 1 - Amendment No. 223 Unit 2 - Amendment No. 229 Revised by letter dated September 18

, 2006

SG Tube Integrity 3.4.17 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.4.17.1 Verify SG tube integrity in accordance with the In accordance Steam Generator Program.

with the Steam Generator Program SR 3.4.17.2 Verify that each inspected SG tube that satisfies the Prior to entering tube repair criteria is plugged in accordance with the MODE 4 following Steam Generator Program.

a SG tube inspection Point Beach 3.4.17-2 Unit 1 - Amendment No. 223 Unit 2 - Amendment No. 229 Revised by letter dated September 18, 2006