Morgan, Lewis & BockiUS LLP 1111 Pennsylvania Avenue, NW Washington, DC 20004 MOU NS LAW Tel: 202.739.3000 COUNSELORS AT LAW Fax: 202.739.3001 www.morganlewis.com Donald P. Ferraro Associate 202.739.5376 dferraro@morganlewis.com September 11, 2006 VIA FEDEX Sara E. Brock Office of the General Counsel U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Re:

Request Under 10 CFR H 2.390 to Withhold Materials from Public Disclosure

Dear Ms. Brock:

As we discussed during our recent telephone conversations, FirstEnergy Nuclear Operating Company (FENOC) has reviewed the five boxes of documents found at Davis-Besse in June 2006 to determine which documents may contain proprietary information. Attached to this letter is a matrix which shows the proprietary document file name (corresponding to the two CDs hand delivered to your representative on September 2, 2006), the pages that contain the proprietary information, the owner of that information, and a brief description. FENOC requests that the documents be withheld from public disclosure under 10 CFR §§ 2.390(a)(4) because they contain trade secrets, commercial, or financial information.

As we discussed, the documents on the two CDs produced on September 2, 2006, do not contain the documents produced to you on July 11, 2006. Those documents were removed from the five boxes because they were potentially responsive to prior NRC subpoenas, converted to pdf files, and produced to you on a CD that contained two folders -

one containing 62 non-proprietary documents, the other containing 11 proprietary documents. In sum, the documents in the July 11 production and those in the September 2 production constitute the entire population of the five boxes of newly discovered documents.

Morgan Lewis COUNSELORS AT LAW Sara E. Brock September 11, 2006 Page 2 Please feel free to call me if you have any questions or would like to discuss these matters further.

Sincerely, Donald P. Ferraro Attachment cc:

D. Jenkins

Proprietary Documents in Five Boxes of "R. Cook" Documents Discovered at Davis-Besse in June 2006 for which FENOC Requests Withholding from Public Disclosure Under 10 CFR § 2.390(a)(4)

No.

File Name

-Page(s)'

Owner I

Description Box 1

1.

00094.pdf 286 Framatome Process Traveler - ID Temper Bead Repair

2.

00526.pdf 2-3 INPO OE 13398, "Control Rod Drive Mechanism Nozzle Circumferential Flaws and Material Void at Davis-Besse"

3.

00526.pdf 8

Framatome Service Structure Map - CRDM/Core Locations

4.

00926.pdf 8-38 Framatome Serial 2761, "Reactor Pressure Vessel Head Penetration Examination Plans for the Davis-Besse Nuclear Power Station," Attachment 2, "Framatome UT Inspection Approach"

5.

01952.pdf 2-5 EPRI "Key Plant Parameters for PWR Reactor Vessel Head Nozzle PWSCC Assessments (July 2001)"

6.

01961.pdf All Framatome Engineering Information Record No. 5013435-02, "CRDM Nozzle/Bore Dimensional Analysis" Box 2

7.

02612.pdf 158-165 EPRI "Key Plant Parameters for PWR Reactor Vessel Head Nozzle PWSCC Assessments (July 2001)"

8.

02612.pdf 335-348 Framatome Engineering Information Record No. 5013435-02, "CRDM Nozzle/Bore Dimensional Analysis" Page numbers correspond to the total pdf pages in the file, not the numbers on each page of the document.

I1 Proprietary Documents in Five Boxes of "R. Cook" Documents Discovered at Davis-Besse in June 2006 for which FENOC Requests Withholding from Public Disclosure Under 10 CFR § 2.390(a)(4)

No.

File Name Page(s)'

Owner Description

9.

04229.pdf All EPRI Draft MRP-55, "Materials Reliability Program (MRP) Recommended Crack Growth Rates for Evaluating Primary Water Stress Corrosion Cracking (PWSCC) of Alloy 600 CRDM Nozzle Material" Box 3

10.

05620.pdf 29-31 EPRI Three pages from EPRI "Handbook of Nuclear Materials," dated December 1997

11.

06585.pdf All Framatome

& Welding Procedure Specification WP8/8/F5AW2-03

  • Procedure Qualification Record PQ4364-00 a

Procedure Qualification Record PQ4379-00

  • Procedure Qualification Record PQ7037-02 Procedure Qualification Record PQ7038-03
  • Procedure Qualification Record PQ7114-02
12.

06616.pdf All Framatome Welding Procedure Specification WP43/43/F43AW3-04 Procedure Qualification Record PQ7060-01 Procedure Qualification Record PQ5394-01

13.

06633.pdf All Framatome Welding Procedure Specification WP3/43/F43TBSCa3-00

& Procedure Qualification Record PQ7164-02 a

Procedure Qualification Record PQ7183-01 Proprietary Documents in Five Boxes of "R. Cook" Documents Discovered at Davis-Besse in June 2006 for which FENOC Requests Withholding from Public Disclosure Under 10 CFR § 2.390(a)(4)

No.

File Name Page(s)'

Owner Description

14.

06652.pdf All Framatome

  • Welding Procedure Specification WP3/F5CLTB2-00
  • Procedure Supplement 55-PS0037-01
  • Procedure Qualification Record PQ7075-01
15.

06669.pdf All Framatome 0 Engineering Information Record 51-5017815-00, "Davis-Besse RVCH Erosion Mockup Requirements @CRDM Penetration #3"

  • Nozzle #3 Penetration Process Traveler, "Demonstration Mockup, Part A, RVCH Repair"
16.

06707.pdf All Framatome Framatome ANP Nondestructive Examination Procedure, "Ultrasonic Examination of Temper Bead Weld Repairs"

17.

06723.pdf All Framatome Framatome ANP Nondestructive Examination Procedure, "Visible Solvent Removable Liquid Penetrant Examination Procedure"

18.

06735.pdf All SPEC Nondestructive Examination Procedure, "Radiographic Testing" American Technical Services

19.

06778.pdf All Framatome Drawing, "Demonstration Mockup RVH Repair"

20.

06779.pdf All Framatome 0 Special Process Procedure - 5 (SPP-5), "Temper Bead Weld Repair"

  • Procedure Supplement 55-PS0035-00 Proprietary Documents in Five Boxes of "R. Cook" Documents Discovered at Davis-Besse in June 2006 for which FENOC Requests Withholding from Public Disclosure Under 10 CFR § 2.390(a)(4)

No.

File Name Page(s)l Owner Description

21.

06797.pdf All Framatome

  • Welding Procedure Specification WP3/8/F5HT2-00
  • Procedure Supplement 55-PS0036-00

" Procedure Qualification Record 55-PQ3840-00

22.

06827.pdf All INPO SER 11-94, Supplement 1, "Feedflow Input Error to Secondary Calorimetric Results in Reactor Operation Above Thermal Power Limit"

23.

06972.pdf All INPO OEI 1658, "RCS Instrument Valve Stem Failure" (page 1)

24.

06973.pdf All INPO OE1 1658, "RCS Instrument Valve Stem Failure" (page 2)

25.

06974.pdf All INPO OE 11658, "RCS Instrument Valve Stem Failure" (page 3)

26.

06975.pdf All INPO OE1 1658, "RCS Instrument Valve Stem Failure" (page 4)

27.

06985.pdf All EPRI One page from EPRI "Handbook of Nuclear Materials," dated December 1997

28.

06986.pdf All EPRI One page from EPRI "Handbook of Nuclear Materials," dated December 1997

29.

06987.pdf All EPRI One page from EPRI "Handbook of Nuclear Materials," dated December 1997

30.

06991.pdf All INPO OE2422, "Improper Heat Treatment of Valve Stem"

31.

07001.pdf All INPO OE9094, "RCS Bypass Loop Valve Failure" (page 1)

32.

07002.pdf All INPO OE9094, "RCS Bypass Loop Valve Failure" (page 2)

33.

07003.pdf All INPO OE7290, "Stem-disc Separation of Manual Valves" (page 1)

Proprietary Documents in Five Boxes of "R. Cook" Documents Discovered at Davis-Besse in June 2006 for which FENOC Requests Withholding from Public Disclosure Under 10 CFR § 2.390(a)(4)

No.

File Name Page(s)'

Owner Description

34.

07004.pdf All INPO OE7290, "Stem-disc Separation of Manual Valves" (page 2)

35.

07005.pdf All INPO OE7290, "Stem-disc Separation of Manual Valves" (page 3)

36.

07006.pdf All INPO OE7290, "Stem-disc Separation of Manual Valves" (page 4)

37.

07007.pdf All INPO OE7290, "Stem-disc Separation of Manual Valves" (page 5)

38.

07008.pdf All INPO OE7290, "Stem-disc Separation of Manual Valves" (page 6)

39.

07009.pdf All INPO OE7290, "Stem-disc Separation of Manual Valves" (page 7)

40.

07010.pdf All INPO OE7290, "Stem-disc Separation of Manual Valves" (page 8)

41.

0701 l.pdf All INPO OE7290, "Stem-disc Separation of Manual Valves" (page 9)

42.

07795.pdf 4-26 Framatome SIA Calculation Package, "Operability and Root Cause Evaluation of the Damage of the Reactor Pressure Vessel Head Wastage Cavity"

43.

07897.pdf 24-87 Framatome Draft Calculation Package," Stress Profile and K-Solution dor DB Monte Carlo Analysis" (8 copies of 8-page calculation)

44.

07984.pdf All Framatome Engineering Information Record No. 51-5015818-00, "Davis-Besse CRDM Nozzle Heat Information" (first 2 pages of 4-page document)

45.

07986.pdf 1-30 Framatome Engineering Information Record No. 51-5015818-00, "Davis-Besse CRDM Nozzle Heat Information" (last 2 pages of 4-page document, 7 copies of 4-page document)

Proprietary Documents in Five Boxes of "R. Cook" Documents Discovered at Davis-Besse in June 2006 for which FENOC Requests Withholding from Public Disclosure Under 10 CFR § 2.390(a)(4)

No.

File Name Page(s)l Owner Description

46.

08075.pdf 14-49 Framatome Calculation Summary Sheet No. 32-5015453-00, "DB CRDM Nozzle IDTB Weld Anomaly Flaw Evaluations" 51-59 Framatome Calculation Summary Sheet No. 32-5015453-0 1, "DB CRDM Nozzle IDTB Weld Anomaly Flaw Evaluations" (9 pages of 36-page document)

Box 4

47.

0845 l.pdf 9-46 Framatome In proprietary version of Serial 2743, SIA Calculation Package W-ENTP-1 Q-306, "Davis-Besse Technical Response to NRC Bulletin 2001-01"

48.

08919.pdf 4-5 Framatome "Davis-Besse Repair Plan for Nozzle 2"

49.

08984.pdf 24 Framatome "DB-I reactor Vessel Head Lifting Pressure Calculation (Preliminary)"

50.

09176.pdf 27 Framatome Engineering Input to No. 3 Repair Plan

51.

09382.pdf 1

EPRI Plant PWSCC Ranking and Supporting Information 28-32 Framatome SIA Calculation Package W-ENTP-1 1Q-314, "Davis-Besse Technical Response to NRC Bulletin 2001-01"

52.

10922.pdf 41-71 Framatome SIA Calculation Package W-DB-O1Q-301, "Operability and Root Cause Evaluation of the Damage of the Reactor Pressure Vessel Head at Davis-Besse"

53.

11248.pdf 2-5 EPRI Attachment to July 31, 2001 letter from A. Marion, NEI, to B. Sheron, NRC: "Key Plant Parameters for PWR Reactor Vessel Head Nozzle PWSCC Assessments (July 2001)"

54.

11415.pdf All Framatome Engineering Information Record 51-5015818-00, "Davis-Besse CRDM Nozzle Heat Information" Proprietary Documents in Five Boxes of "R. Cook" Documents Discovered at Davis-Besse in June 2006 for which FENOC Requests Withholding from Public Disclosure Under 10 CFR § 2.390(a)(4)

No.

File Name Page(s)'

Owner Description

55.

11419.pdf All Framatome Engineering Information Record 51-5015816-00, "Stress Profile and K-Solution for DB Monte Carlo Analysis"

56.

11427.pdf 6-72 Framatome Report BAW-2409P, "CRDM Nozzle ID Temper Bead Weld Repair Process Qualification" 78-79 INPO Event Description No. 38435, "Discovery of Apparent Through-Wall Indications on Control Rod Drive Mechanism Penetrations"

57.

11514.pdf All INPO Event Descriptions Box 5 None