ML062300028
| ML062300028 | |
| Person / Time | |
|---|---|
| Site: | Sequoyah |
| Issue date: | 08/15/2006 |
| From: | Howard S Tennessee Valley Authority |
| To: | Myers P Office of Nuclear Reactor Regulation, State of TN, Dept of Environment & Conservation, Div of Water Pollution Control |
| References | |
| Download: ML062300028 (12) | |
Text
Tennessee Valley Authority, Post Office Box 2000, Soddy-Daisy, Tennessee 37384-2000 August 15, 2006 Ms. Pamala Myers Permit Section Tennessee Department of Environment & Conservation Division of Water Pollution Control 6th Floor, L & C Annex 401 Church Street Nashville, Tennessee 37243-1534
Dear Ms. Myers:
SEQUOYAH NUCLEAR PLANT (SQN) - NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMIT NO. TN0026450 - MSW-101 UPDATED MSDS AND NALCO LETTER Enclosed is the updated MSDS for MSW-1 01 and a letter from Nalco with additional toxicity information. All other information regarding the use of MSW-101 was submitted in a previous letter dated March 27, 2006. Please contact Ann Hurt (423-843-6714) or myself (423-843-6700) if you need additional information or have comments or questions.
I certify under penalty of law that this document and all of its attachments were prepared under my direction or my supervisor in accordance with a system designed to assure qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.
Sincerely, Stephanie A. Howard Principal Environmental Engineer Signatory Authority for J. Randy Douet Site Vice President Sequoyah Nuclear Plant Ped Wo recycled paper
Enclosures cc (Enclosures):
Mr. Edward M. Polk, Jr., P.E.
Manager, Permit Section Tennessee Department of
.Environment & Conservation Division of Water Pollution Control 6th Floor, L & C Annex 401 Church Street Nashville, Tennessee 37243-1534 Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Chattanooga Environmental Assistance Center Division of Water Pollution Control State Office Building, Suite 550 540 McCallie Avenue Chattanooga, Tennessee 37402-2013
Ricky Stackhouse, Ph.D.
Staff Toxicologist Tel: 630-305-1398 Fax: 630-305-2945 e-mail: rstackhouse@nalco.com Jfth...w N A LC 0" August 3, 2006 Nalco Company Innovation Delivery Group 1601 West Diehl Road Naperville, IL 60563-1198 630 305 1000 www.nalco.com Rick M. Sherrard, Ph.D.
Environmental Scientist - Toxicologist Tennessee Valley Authority 1101 Market St, PSC 1X-C Chattanooga, TN 37402 Dr. Sherrad:
In addition to the aquatic toxicity information listed on the MSDS for MSW-1 01, the following information is also available for the product:
Species End Point Value Test Substance Fathead Minnow 7 day IC25 (growth) 2,735 mg/l pH Adjusted Product Fathead Minnow 7 day IC25 (growth) 1,294.6 mg/l Non-pH Adjusted Product (Results expressed as non-aqueous components)
Ceriodaphnia dubia 7 day IC25 133.3 mg/I pH Adjusted Product (reproduction)
Ceriodaphnia dubia 7 day IC25 20.1 mg/1 Non-pH Adjusted Product (Results (reproduction) expressed as non-aqueous components)
As a point of clarification, these studies were not run concurrently, but rather the pH adjusted product study Was conducted first followed by the non-pH adjusted product. In addition, the term "non-aqueous components" is equivalent to the term "active ingredients" as used to describe components of a product that serve a function in the end use application. However, it is not equivalent to the EPA FIFRA term that denotes a component with pesticidal activity.
From your communications to me, I understand that TVA 1) can not validate the pH adjusted test results,
- 2) does not concur with the non-pH-adjusted C. dubia chronic test results because of a large number of males in the test population and 3) however, does consider the results from the C. dubia test conservative and derived in a manner consistent with the EPA Methods manual.
Please contact your local Nalco sales representative or myself, if you have additional questions regarding this product.
- Regards, Ricky Stackhouse, Ph.D.
Staff Toxicologist
ýrn
NALCO MATERIAL SAFETY DATA SHEET PRODUCT MSW-101 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC
- 11.
1 CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME:
MSW-101 APPLICATION:
WATER TREATMENT COMPANY IDENTIFICATION:
Nalco Company 1601 W. Diehl Road Naperville, Illinois 60563-1198 EMERGENCY TELEPHONE NUMBER(S):
(800) 424-9300 (24 Hours)
CHEMTREC NFPA 704M/HMIS RATING HEALTH:
0/1 FLAMMABILITY:
0/0 INSTABILITY:
0/0 OTHER:
0 = Insignificant 1 = Slight 2 = Moderate 3 = High 4 = Extreme
- 12.
1 COMPOSITIONIINFORMATION ON INGREDIENTS Based on our hazard evaluation, none of the substances in this product are hazardous.
I 3.
1 HAZARDS IDENTIFICATION I.
- EMERGENCY OVERVIEW**
- EMERGENCY OVERVIEW**
CAUTION May cause irritation with prolonged contact.
Do not get in eyes, on skin, on clothing. Do not take internally. Use with adequate ventilation. In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. After contact with skin, wash immediately with plenty of water.
Wear suitable protective clothing.
May evolve oxides of phosphorus (POx) under fire conditions.
PRIMARY ROUTES OF EXPOSURE :
Eye, Skin HUMAN HEALTH HAZARDS -ACUTE:
EYE CONTACT:
No adverse effects expected.
SKIN CONTACT:
No adverse effects expected.
INGESTION:
Not a likely route of exposure. No adverse effects expected.
Nalco Company 1601 W. Diehl Road ° Naperville. Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access 1/9
MATERIAL SAFETY DATA SHEET NALCO PRODUCT NALC MSW-101 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC INHALATION:
Not a likely route of exposure. No adverse effects expected.
SYMPTOMS OF EXPOSURE:
Acute :
A review of available data does not identify any symptoms from exposure not previously mentioned.
Chronic :
A review of available data does not identify any symptoms from exposure not previously mentioned.
AGGRAVATION OF EXISTING CONDITIONS:
A review of available data does not identify any worsening of existing conditions.
- 14.
I FIRST AID MEASURES EYE CONTACT:
Flush affected area with water. If symptoms develop, seek medical advice.
SKIN CONTACT:
Flush affected area with water. If symptoms develop, seek medical advice.
INGESTION:
Do not induce vomiting without medical advice. If conscious, washout mouth and give water to drink. If symptoms develop, seek medical advice.
INHALATION:
Remove to fresh air, treat symptomatically. If symptoms develop, seek medical advice.
NOTE TO PHYSICIAN:
Based on the individual reactions of the patient, the physician's judgement should be used to control symptoms and clinical condition.
- 15.
FIRE FIGHTING MEASURES FLASH POINT:
None EXTINGUISHING MEDIA:
This product would not be expected to burn unless all the water is boiled away. The remaining organics may be ignitable. Keep containers cool by spraying with water. Use extinguishing media appropriate for surrounding fire.
FIRE AND EXPLOSION HAZARD:
May evolve oxides of phosphorus (POx) under fire conditions.
SPECIAL PROTECTIVE EQUIPMENT FOR FIRE FIGHTING:
In case of fire, wear a full face positive-pressure self contained breathing apparatus and protective suit.
Nalco Company 1601 W. Diehl Road - Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access 2/9
MATERIAL SAFETY DATA SHEET PRODUCT MSW-101 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC
- 6.
ACCIDENTAL RELEASE MEASURES PERSONAL PRECAUTIONS:
Restrict access to area as appropriate until clean-up operations are complete. Ensure clean-up is conducted by trained personnel only. Ventilate spill area if possible. Do not touch spilled material. Stop or reduce any leaks if it is safe to do so. Use personal protective equipment recommended in Section 8 (Exposure Controls/Personal Protection). Notify appropriate government, occupational health and safety and environmental authorities.
METHODS FOR CLEANING UP:
SMALL SPILLS: Soak up spill with absorbent material. Place residues in a suitable, covered, properly labeled container. Wash affected area. LARGE SPILLS: Contain liquid using absorbent material, by digging trenches or by diking. Reclaim into recovery or salvage drums or tank truck for proper disposal. Wash site of spillage thoroughly with water. Contact an approved waste hauler for disposal of contaminated recovered material. Dispose of material in compliance with regulations indicated in Section 13 (Disposal Considerations).
ENVIRONMENTAL PRECAUTIONS:
Do not contaminate surface water.
- 17.
1 HANDLING AND STORAGE HANDLING:
Do not take internally. Do not get in eyes, on skin, on clothing. Have emergency equipment (for fires, spills, leaks, etc.) readily available. Ensure all containers are labeled. Keep the containers closed when not in use. Use with adequate ventilation.
STORAGE CONDITIONS:
Store the containers tightly closed. Store in suitable labeled containers.
SUITABLE CONSTRUCTION MATERIAL:
HDPE (high density polyethylene), Stainless Steel 304, Compatibility with Plastic Materials can vary; we therefore recommend that compatibility is tested prior to use.
- 18.
1 EXPOSURE CONTROLS/PERSONAL PROTECTION OCCUPATIONAL EXPOSURE LIMITS:
This product does not contain any substance that has an established exposure limit.
ENGINEERING MEASURES:
General ventilation is recommended. Local exhaust ventilation may be necessary when dusts or mists are generated.
RESPIRATORY PROTECTION:
Respiratory protection is not normally needed. Respiratory protection is not normally needed. FULL-FACE MASK WITH WHITE CARTRIDGE HAND PROTECTION:
Neoprene gloves, Nitrile gloves, Butyl gloves, PVC gloves Nalco Company 1601 W. Diehl Road
- Naperville. Illinois 60563-1198 ; (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access 3/9
NALCO MATERIAL SAFETY DATA SHEET EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC SKIN PROTECTION:
Wear standard protective clothing; EYE PROTECTION:
Wear chemical splash goggles.
HYGIENE RECOMMENDATIONS:
If clothing is contaminated, remove clothing and thoroughly wash the affected area. Launder contaminated clothing before reuse. Keep an eye wash fountain available. Keep a safety shower available.
- 19.
1 PHYSICAL AND CHEMICAL PROPERTIES PHYSICAL STATE Liquid APPEARANCE Colorless Clear ODOR None SPECIFIC GRAVITY 1.35 @ 77 -F /25 -C DENSITY 11.2 lb/gal SOLUBILITY IN WATER Complete pH (100 %)
4.7 - 5.3 BOILING POINT 212 °F / 100 °C Minimum VAPOR PRESSURE Same as water VOC CONTENT 0 % Calculated Note: These physical properties are typical values for this product and are subject to change.
110.
1 STABILITY AND REACTIVITY STABILITY:
Stable under normal conditions.
HAZARDOUS POLYMERIZATION:
Hazardous polymerization will not occur.
CONDITIONS TO AVOID:
Freezing temperatures.
MATERIALS TO AVOID:
Contact with strong alkalies (e.g. ammonia and its solutions, carbonates, sodium hydroxide (caustic), potassium hydroxide, calcium hydroxide (lime), cyanide, sulfide, hypochlorites,'chlorites) may generate heat, splattering or boiling and toxic vapors.
HAZARDOUS DECOMPOSITION PRODUCTS:
Under fire conditions:
Oxides of phosphorus, Oxides of sodium Nalco Company 1601 W. Diehl Road
- Naperville, Illinois 60563-1198 ° (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access 4/9
NALCO MATERIAL SAFETY DATA SHEET PRODUCT MSW-101 EMERGENCY TELEPHONE NUMBER(S)
(800) 424.9300 (24 Hours)
CHEMTREC 111.
- TOXICOLOGICAL INFORMATION I
No toxicity studies have been conducted on this product.
SENSITIZATION:
This product is not expected to be a sensitizer.
CARCINOGENICITY:
None of the substances in this product are listed as carcinogens by the International Agency for Research on Cancer (IARC), the National Toxicology Program (NTP) or the American Conference of Governmental Industrial Hygienists (ACGIH).
- 12.
ECOLOGICAL INFORMATION ECOTOXICOLOGICAL EFFECTS:
The following results are for the product.
ACUTE FISH RESULTS:
Species Exposure LC50 Test Descriptor Fathead Minnow 96 hrs 3,661 mg/I pH Adjusted Product Fathead Minnow 96 hrs 1,352 mg/I Non-pH Adjusted Product (Results expressed as non-aqueous components)
ACUTE INVERTEBRATE RESULTS:
Species Exposure LC50 EC50 Test Descriptor Ceriodaphnia dubia 48 hrs 1,806 mg/I pH Adjusted Product Ceriodaphnia dubia 48 hrs 1,189 mg/I Non-pH Adjusted Product (Results expressed as non-aqueous components)
CHRONIC FISH RESULTS:
Species Exposure NOEC / LOEC End Point Test Descriptor Fathead Minnow 7 Days 2,500 mg/I / 5,000 Growth pH Adjusted Product mg/I Fathead Minnow 7 Days 932.5 mg/I / 1,865.0 Growth Non-pH Adjusted mg/I Product (Results expressed as non-aqueous components)
CHRONIC INVERTEBRATE RESULTS:
Species Test Type NOEC / LOEC End Point Test Descriptor Ceriodaphnia dubia 3 Brood 125 mg/I / 250 mg/I Reproduction pH Adjusted Product Ceriodaphnia dubia 3 Brood 11.7 mg/I / 23.3 Reproduction Non-pH Adjusted mg/I Product (Results expressed as non-aqueous components)
Nalco Company 1601 W. Diehl Road
- Naperville, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access 5/9
NALCO MATERIAL SAFETY DATA SHEET PRODUCT MSW-101
=MCKICRU IrLt~r1nu1V=VUMtJI%4.Z)
(800) 424-9300 (24 Hours)
CHEMTREC MOBILITY:
High phosphate levels in surface water can cause eutrophication with subsequent algal blooms and oxygen depletion.
BIOACCUMULATION POTENTIAL This preparation or material is notexpected to bioaccumulate.
If released into the environment, see CERCLA/SUPERFUND in Section 15.
113.
I DISPOSAL CONSIDERATIONS I
If this product becomes a waste, it is not a hazardous waste as defined by the Resource Conservation and Recovery Act (RCRA) 40 CFR 261, since it does not have the characteristics of Subpart C, nor is it listed under Subpart D.
As a non-hazardous waste, it is not subject to federal regulation. Consult state or local regulation for any additional handling, treatment or disposal requirements. For disposal, contact a properly licensed waste treatment, storage, disposal or recycling facility.
114.
I TRANSPORT INFORMATION I
- The information in this section is for reference only and should not take the place of a shipping paper (bill of lading) specific to an order. Please note that the proper Shipping Name / Hazard Class may vary by packaging, properties, and mode of transportation. Typical Proper Shipping Names for this product are as follows.
LAND TRANSPORT:
Proper Shipping Name:
AIR TRANSPORT (ICAO/IATA):
Proper Shipping Name:
PRODUCT IS NOT REGULATED DURING TRANSPORTATION PRODUCT IS NOT REGULATED DURING TRANSPORTATION PRODUCT IS NOT REGULATED DURING TRANSPORTATION MARINE TRANSPORT (IMDG/IMO):
Proper Shipping Name :
115.
1 REGULATORY INFORMATION NATIONAL REGULATIONS, USA:
OSHA HAZARD COMMUNICATION RULE, 29 CFR 1910.1200:
Based on our hazard evaluation, none of the substances in this product are hazardous.
Nalco Company 1601 W. Diehl Road
- Naperville, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access 619
NALCO CERCLANSUPERFUND, 40 CFR 117,302:
Notification of spills of this product is not required.
MATERIAL SAFETY DATA SHEET PRODUCT MSW-101 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC SARA/SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (TITLE III) - SECTIONS 302,311, 312, AND 313:
SECTION 302 - EXTREMELY HAZARDOUS SUBSTANCES (40 CFR 355):
This product does not contain substances listed in Appendix A and B as an Extremely Hazardous Substance.
SECTIONS 311 AND 312 - MATERIAL SAFETY DATA SHEET REQUIREMENTS (40 CFR 370):
Our hazard evaluation has found that this product is not hazardous under 29 CFR 1910.1200.
Immediate (Acute) Health Hazard Delayed (Chronic) Health Hazard Fire Hazard Sudden Release of Pressure Hazard Reactive Hazard Under SARA 311 and 312, the EPA has established threshold quantities for the reporting of hazardous chemicals.
The current thresholds are: 500 pounds or the threshold planning quantity (TPQ), whichever is lower, for extremely hazardous substances and 10,000 pounds for all other hazardous chemicals.
SECTION 313 - LIST OF TOXIC CHEMICALS (40 CFR 372):
This product does not contain substances on the List of Toxic Chemicals.
TOXIC SUBSTANCES CONTROL ACT (TSCA):
The substances in this preparation are included on or exempted from the TSCA 8(b) Inventory (40 CFR 710)
NSF INTERNATIONAL:
This product has received NSF/International certification under NSF/ANSI Standard 60 in the corrosion and scale control and sequestering categories. The official name is "Blended Corrosion Inhibitor." Maximum product application dosage is : 34 mg/I.
FEDERAL WATER POLLUTION CONTROL ACT, CLEAN WATER ACT, 40 CFR 401.15 / formerly Sec. 307,40 CFR 116.4 / formerly Sec. 311 :
This product contains the following substances listed in the regulation:
Substance(s)
Citations Sodium Phosphate, Tribasic Sec. 311 CLEAN AIR ACT, Sec. 112 (40 CFR 61, Hazardous Air Pollutants), Sec. 602 (40 CFR 82, Class I and II Ozone Depleting Substances) :
None of the substances are specifically listed in the regulation.
CALIFORNIA PROPOSITION 65:
This product does not contain substances which require warning under California Proposition 65.
Nalco Company 1601 W. Diehl Road, Naperville, Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access 7/9
rNALC4 MATERIAL SAFETY DATA SHEET PRODUCT MSW-101 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC MICHIGAN CRITICAL MATERIALS:
None of the substances are specifically listed in the regulation.
STATE RIGHT TO KNOW LAWS:
The following substances are disclosed for compliance with State Right to Know Laws:
Sodium Phosphate, Tribasic 7601-54-9 NATIONAL REGULATIONS, CANADA:
WORKPLACE HAZARDOUS MATERIALS INFORMATION SYSTEM (WHMIS):
This product has been classified in accordance with the hazard criteria of the Controlled Products Regulations (CPR) and the MSDS contains all the information required by the CPR.
WHMIS CLASSIFICATION:
Not considered a WHMIS controlled product.
CANADIAN ENVIRONMENTAL PROTECTION ACT (CEPA):
The substances in this preparation are listed on the Domestic Substances List (DSL), are exempt, or have been reported in accordance with the New Substances Notification Regulations.
INTERNATIONAL CHEMICAL CONTROL LAWS EUROPE The substances in this preparation have been reviewed for compliance with the EINECS or ELINCS inventories.
- 16.
OTHER INFORMATION This product material safety data sheet provides health and safety information. The product is to be used in applications consistent with our product literature. Individuals handling this product should be informed of the recommended safety precautions and should have access to this information. For any other uses, exposures should be evaluated so that appropriate handling practices and training programs can be established to insure safe workplace operations. Please consult your local sales representative for any further information.
REFERENCES Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices, American Conference of Governmental Industrial Hygienists, OH., (Ariel Insight# CD-ROM Version), Ariel Research Corp.,
Bethesda, MD.
Hazardous Substances Data Bank, National Library of Medicine; Bethesda, Maryland (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO.
IARC Monographs on the Evaluation of the Carcinogenic Risk of Chemicals to Man, Geneva: World Health Organization, International Agency for Research on Cancer.
Integrated Risk Information System, U.S. Environmental Protection Agency, Washington, D.C. (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO.
Nalco Company 1601 W. Diehl Road
- Naperville, Illinois 60563-1198 - (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access 8/9
SNALCO.
MATERIAL SAFETY DATA SHEET PRODUCT MSW-101 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC Annual Report on Carcinogens, National Toxicology Program, U.S. Department of Health and Human Services, Public Health Service.
Title 29 Code of Federal Regulations, Part 1910, Subpart Z, Toxic and Hazardous Substances, Occupational Safety and Health Administration (OSHA), (Ariel Insight# CD-ROM Version), Ariel Research Corp., Bethesda, MD.
Registry of Toxic Effects of Chemical Substances, National Institute for Occupational Safety and Health, Cincinnati, OH, (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO.
Ariel Insight# (An integrated guide to industrial chemicals covered under major regulatory and advisory programs),
North American Module, Western European Module, Chemical Inventories Module and the Generics Module (Ariel Insight# CD-ROM Version), Ariel Research Corp., Bethesda, MD.
The Teratogen Information System, University of Washington, Seattle, WA (TOMES CPS# CD-ROM Version),
Micromedex, Inc., Englewood, CO.
Prepared By: Product Safety Department Date issued : 08/02/2006 Version Number: 1.8 Nalco Company 1601 W. Diehl Road, Naperville. Illinois 60563-1198 * (630)305-1000 For additional copies of an MSDS visit www.nalco.com and request access 9/9