OAK RIDQE INSTITUTE FOR SCIENCE AND EDUCATION August 2,2006 hk. Wfiam Snell US. Nuclear Regulatory Commission Region I11 2443 Warrenville Road Lisle, IL 60532-4351
SUBJECT:
FINAL LETTER REPORT FOR ANALYTICAL RESULTS FOR SEVEN WATER SAMPLES, BATCH SIX, FROM THE VICINITY OF THE DRESDEN GENERATING STATION, DRESDEN, ILLINOIS
[INSPECTION REPORT NO. 050-00237/2006-0101 (RFTA NO.06-001)
Dear Mr. Snell:
The Oak Ridge Institute for Science and Education (ORISE) received Batch Six, consisting of seven water samples, on July 17,2006 which were collected in the vicinity of the Dresden Generating Station in Dresden, Illinois. The samples were analyzed for tritium to a minimum detectable concentration of 180 pG/L using a liquid scintillation analyer. The chain-of-custody identified one water sample to be analyzed by gamma spectroscopy (GS). The sample identifications and collection data are presented in Table 1. The GS data are presented in Table 2. The tritium data are presented in Table 3. The pertinent procedure references are provided in the specific tables.
ORISEs Quality Control (Qc, requirements were met for these analyxs. The Qc files are avdable for
)Tour review upon request.
My contact information is listed below. You may also contact Wade Iveyat 865.576.9184 with any questions or comments.
Sincerely, Dale Condra, Manager Laboratory RDC:WI:ess Enclosures C:
B. Watson, NMSS/DWMEP/DD/SP 7-18 E. Abelquist, ORISE E. Knox-Davin, NRCNMSS/NVFN 8A23 G. Bonano, NRC Region 111 S. Kirk, ORISE File 1694 1
Distribution a roval and concurrence :
[-?kt Team Member -
I QalityManager I
cly I
Volce: 865.241.3242 Fax: 865.241.3248 E-mil: CondraD@orau.gov RECElVED AUlj 0 8
TABLE 1 ORISE Sample NRC Region 111 Collection ID Sample ID Date Collection Time Dresden Generating Sratlon projecrr/Z00608~OZ/Dan Tablrr/l694 Barch Six
TABLE 2 ORISE Sample ID 1694W0116 CONCENTRATIONS OF SELECTED GAMMA EMITTING RADIONUCLIDES IN ASELECTED WATER SAMPLE BY GAMMA SPECTROSCOPY CPl, REVISION 15 DRESDEN GENERATING STATION DRESDEN, ILLINOIS NRCRegionIII.
Radionuclide Concentrations' (pCi/L)
Sample ID co-58 Co-60 Cs-134 0-137 D-06-6-05
-1.9
_+ 2.6b 3 1 ? 3.1 2.9
- 3.5 -3.5 f 6.1 Dresden Genearlng Smrion
TABLE 3 ORISE Sample NRC Region 111 Tritium Concentrations, TPUs, ID Sample ID and MDCs" @Ci/L) 1694W0112 D-06-6-01 720 120b (1 80) 1694W0113 D-06-6-02 150 180 1694W0114 D-06-6-03 60 100 (1 80) 1694W0115 D-06-6-04 50 100 (180) 1694W0116 D-06-6-05 130 110 (180) 1694W0117 D-06-6-06 40
?r 100 (1 80) 1694W0118 D-06-6-07 80 100 (1 80)
--