Tagout: CLEARANCE ORDER Sectinn:.-SWB.-- 4324147 SW-STNR-B 03/10/2004.1

.Componenl to be Worked:

11 SW -STNR -B SERVICE WATERZURN STRAINER B IS-SWP RM

==

Description:==

DISASSEMBLE & CLEAN & REPAIR.

ADMIN OOS LIMIT.OF 10 DAYS.

Special Instructions MANUAL DRAIN (SW-V-15) NO-TAGGED TO ALLOW DRAINING AS NEEDED BEFORE OR DURING MAINTENANCE.

DRAIN FOR -10 MINUTES, THEN CLOSE DURING INITIAL TAGGING.

Worker Notes LCO ACTIONS REQUIRED FOR THIS.WORK. REMOVE STRAINER FROM SERVICE PER 2.2.71 PRIOR TO HANGING TAGOUT. Temporary Air is to be applied to SW-858AV.keep it closed.

Release Notes ENSURE TEMPORARY AIR SUPPLY HAS BEEN REMOVED.

RELEASE TAGS AND RESTART STRAINER IAW2.2.71.

Section Attributes:

Attribute Attribute Description Value MRRS Yes

.CO ACTION REQUIRED Yes IRE IMPAIRMENT REQUIRED Yes ONTAINMENT AFFECTED No EQUIRED PLANT CONDITIONS B ZURN STRAINER BYPASSED Work Order List:

'3:02

)

Number/ Equipment Ii 4324147

-Section Verification:

Status Description Name Verification Date Section Prepared Reed, Daniel W.

12/17/2003 09:28 Section Verified Weiss, Jamie R.

3110412004,22:23 Section Authorized Gilbert, William T.

1/21/2004 02:36

_quip.

Ready for Maintenance Cable, Brian E.

1/21/2004 05:54

__elease Prepared Cable, Brian E.

1/21/2004 05:59

__elease Verified Weiss, Jamie R.

1/21/2004 09:10

__elease Authorized Beger, Nathan L.

11/21/2004 15:53

_ection Complete eiss, Jamie'R.

1/21/2004 16:58 Temporary Safety Devices List:

Page I of I

Section Tag List Tagout: CLEARANCE ORDER Section: SWB 4324147 SWoSTNR-B 03/10/2004,13:0 Tag Tag Equipment Pla Placement Place;lst Place. 2nd Rest Restoration As Left ResL 1st Rest. 2nd Serial Type --------------------------

Seq Configuration Verif Verif Seq Configuration Configuratior Verif Venf No.

  • Equipment Description Date/Time Date/Time Date/Time Date/Time
  • Equipment Location Notes
  • _Noteso, 35256 Danger SW -SW -$192(PB1) 1 DO NOT OPERATE Hung-Hung -

7 PULL TAG PULLTAG

-Hayes, Unruh;.

Knowles, Carpenter, Martin nu, Kols apneMri
  • START SWITCH FOR B&D SW Michael J.; Timothy A.;
  • Restore per 2.2.71 Christophe "Marty" F.;

STRAINER 01/21/2004 01/21/2004 M.;

01/21/2004 SB SW ZURN STRAINER AREA 05:46 05:48 01/21/2004 16:36 1

16:36 3525 Danger EE -MCC-TX(1DL)

2. OFF Hung-Hung,-

6 ON ON-.

Hayes,
Unruh, Knowles, C..

carpenter, Martin

  • SW-STNR-B SW STRAINER B Michael J.;- Timothy A.;

Christophei "Marty" F.;

CONTROL PANEL FEEDER 01/21/2004 01/21/2004 M.;

01/21/2004

  • MCC-TX AUX RELAY ROOM 05:46 05:48 01121/2004 16:36 16:36 35258 Danger SW -V

-194 3 OPEN Hung-Hung-5 CLOSED CLOSEDý

- Hayes,

Unruh, Knowles, C rpenter, Martin SW sTRAINER B BYPASS Michael J.' Timothy A.;

Christophei "Marty" F.;

B & D SW PUMP AREA 01/21/2004 01/21/2004 M.,

01/21/2004 05:46 05:48 01/21/2004 16:36 16:36 35259 Danger SW -V

-17 4 CLOSED Hung-Hung-4 SEALED OPEN SEALED

- Hayes, Unruh,.

Knowles,..

OPEN Carpenter, Martin SSW STRAINER B OUTLET' Michael J.. TimothyA.;

Christopher"Marty" F.;

  • B & D SW PUMP AREA 0.1/21/2004 01/21/2004 M.;

01/21/2004 05:46 05:48 01/21/2004 16:36 16:36 35260 Danger SW -V

-192 5 CLOSED Hung-Hung 3 SEALED OPEN SEALED

- Hayes, Unruh,.

Knowles,-.---

OPEN Carpenter, Martin

  • SW STRAINER B INLET Michael J.; Timothy A.;

Christophei "Marty" F.;

  • B &DSWPUMPAREA 01/21/2004 01/21/2004 M.;

01/21/2004 05:46 05:48 01/21/2004 16:36

_16:36 35261 No Tag SW -V

-5i

'6 --------------

2 CLOSED CLOSED

- Hayes, VALVE SILTS IN, Carpenter, Martin

  • SWSTRAINER BBBACKWASH THROTTLE CLOSED1 Chdstophei "Marty" F.;
  • B & D SW PUMP AREA TILL FULL CLOSED M.;

01/21/2004 01/21/2004 16:36 16:36 35262 No Tag SW -V

-1378 7 ----------------

OPEN OPEN

- Hayes, Carpenter, Martin

  • SW-858AV ISOLATION Christophe "Marty" F.;

A & C SWPUMP AREA M.;.

01/21/200416 01/21/2004 16:36 1i6:36 Page 1 0

Section Tag List Tagout: CLEARANCE ORDER Section: SWB.1-4324147 SW-STNR-B 03/10/2004-13:0 Component Note Note No.

Text SW -SW. -S192(PB1) 3 MRRS EE -MCC -TX(IDL) 3 MRRS SW -V

-194 3

MRRS SW -V

-17 3

MRRS SW -V' -192 3

MRRS SW -V -15 3

MRRS SW -V

-1378 3

jMRRS Component Print Number EE -MCC -TX(1DL)

B5700*3006 EE -MCC -TX(IDL)

B5700*3253 EE -MCC -TX(IDL) 12020*85B-70008 SW -V

-194.

B5700*2006 SHT1 SW -V

-194 P3400*B-99 SW -V

-17 B5700*2006 SHT1 SW -V

-17 P3400*B-102 SW -V

-192 B5700*2006 SHT1 SW -V

-192 P3400*B-102 Sw -V

-15 A3950*856-3 SW -V -15 B5700"2006 SHT1 SW -V -1378 B5700"2006 SHT1 Paqe 2 of

Section Holder List Tagout: CLEARANCE ORDER Section: SWB -1.4324147 SW-STNR-B 03/10/20 Accepted By

-Accepted At Signed On By Released By Released At I eters, Marvin E.

01/2112004 06:00 Peters,; Marvin E.

Peters,.Marvin E.

01/21/2004 15:46 ason, Eric D.

F01/21/2004 06:24 Mason, Eric D.

Mason, Eric D.

01/21/2004 15:04 04 13:C Page 1 ol

Work Order Holder List Tagout: CLEARANCE ORDER Section: SWB 4324147 SW-STNR-B 03/10/2004 13:0 Number:

4324147 Statbý:

Percent Complete:

EXAMINE STRAINER SW-STNR-B Holder Signed On By Sign On Date Signed Off By Sign Off Date

-ewis, Dave lewis, Dave "

01/2112004 06:26

-ewis, Dave 3)1/21/2004 14:57 Sullwold, Kim D.

ullwold, Kim D.

01/21/2004 06:03 Sullwold, Kim D.

31/21/2004 12:31 Page 1 otf