ML061810274

From kanterella
Jump to navigation Jump to search
Oak Ridge Institute for Science and Education Analytical Results for Twenty- Five Water Samples, Batch Two, from the Vicinity of the Quad Cities Station, Cordova, Illinois (Inspection Report No. 050-00254/2006-005)
ML061810274
Person / Time
Site: Quad Cities 
Issue date: 06/23/2006
From: Condra D
Oak Ridge Institute for Science & Education
To: Snell W
Division of Nuclear Materials Safety III
References
FOIA/PA-2010-0209, IR-06-005
Download: ML061810274 (4)


Text

OAK RlDQE INSTITUTE FOR SCIENCE AND EDUCATION Tune 23,2006 Mr. William Snell US. Nuclear Regulatory Commission Region 111 2443 WarrenviUe Road Lisle, IL 60532-4351

SUBJECT:

ANALYTICAL RESULTS FOR TWENTY-FIVE WATER SAMPLES, BATCH TWO, FROM THE VICINITY OF THE QUAD CITIES STATION, CORDOVA, ILLINOIS [INSPECTION REPORT NO. 050-00254/2006-0051 (RFTA NO.06-001)

Dear Mr. Snek The Oak Ridge Institute for Science and Education (ORISE) received 25 water samples, Batch two, on June 7,2006 which were collected in the vicinity of the Quad Cities Station in Cordova, Illinois. The 25 water samples were analyzed for tritium using a liquid scindlation analyzer.

The chain of custody identified three water samples to be analyzed by gamma spectroscopy (GS). The sample identifications and collection data are presented in Table 1. The GS data are presented in Table 2. The tritium data are presented in Table 3. The pertinent procedure references are provided in the specific tables.

ORISE's Quality Control (QC) requirements were met for these analyses. The QC fdes are available for your review upon request.

My contact information is listed below. You may also contact Wade Ivey at 865.576.9184 with any questions or comments.

Sincerely, D ?

l2-L-Dale Condra, Manager Laboratory RDC:WPI:db Enclosures C:

B. Watson, NMSS/DWMEP/DD/SP 7E18 E. Abelqlust, ORISE E. Knox-Davin, NRC/NMSS/TWFN 8A23 G. Bonano, NRC Region I11 S. Kirk, ORISE Flle 1703 Distribution appoval and concurrence :

Technical Management Team Member I4KE Quality Manager 1 Initial3 Voice: 865.241.3242 Fax: 865.241.3248 E-mail: CondraD@orau.gov RECEIVED JUN 3 02006

TABLE 1 SAMPLE IDENTIFICATIONS AND COLLECTION DATA QUAD CITIES STATION CORDOVA, ILLINOIS 1703W0028 1703W0029 Collection Date Q - 0 6 - 0 2 - 2 4 611 12006 2:lO PM 4-06-02-25 6/1/2006 2:20 PM 9:20 AM 2:50 PM 8:OO AM 8:20 AM 8:50 AM 9:lO AM 910 AM 9:40 AM 10:30 AM 2:37 PM 2:45 PM 4:OO PM 415 PM 7:48 AM 9:15 AM Quad Cities Staoon projects11 703lData TabIesl2006-06-23 Dala Tables Batch Tu.0

TABLE 2 ORISE Sample ID 1703W0006 1703W0016 CONCENTRATIONS OF SELECTED GAMMA EMITTING RADIONUCLIDES IN SELECTED WATER SAMPLES BY GAMMA SPECTROSCOPY CP1, REVISION 15 QUAD CITIES STATION CORDOVA, ILLINOIS NRC Region 111.

Radionuclide Concentrations" (pCi/L)

Sample ID co-58 Co-60 cs-l34 cs-w7 Q-06-02-02

-1.4 2 2.2b -0.5 I 2.3 -1.6 f 2.7 -0.1 2 2.1 0-06.02-12

-1.4 k 2.9 2.3 ? 2.9 2.1 i-2.8 0.8 ? 6.2 1 1703W0026 I Q-06-02-22 1 2.5 f 3.1 1 0.7 t 2.9 1 0.4 I 3.21 0.5 i 2.8)

%ne range of MDCs for the selected racbonuclidcs 1s 3.6 pCi/L to 5.4 pCi/L.

bUnccrrainues represent the 95% confidencc Icvel, based on total propugsted uncertaintic$

Quad Ctties Station projects11 703lDala TablcslZ006-06-23 Data Tables Batch Two

TABLE 3 CONCENTRATIONS OF TRITIUM IN WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS AP2, REVISION 15; CP4, REVISION 3 QUAD CITIES STATION CORDOVA, ILLINOIS MDCs are in parenthesis.

bUncertGnes icprerenr the 95% conSdence led, based on total propaptcd uncertwnbes.

Zero YIIUCS BTC due to roudng.

Quad Cities Station prajecull703iData Tablcsl2006-06-23 Data Tables Batch Two