D. Pursuant to the Act and 10 CFR Parts 30, 40 and 70, NMC to receive, possess and use in amounts as required any byproduct, source or special nuclear material without restriction to chemical or physical form, for sample analysis or instrument calibration or associated with radioactive apparatus or components; and E. Pursuant to the Act and 10 CFR Parts 30 and 70, NMC to possess such byproduct and special nuclear materials as may be produced by the operation of the facility, but not to separate such materials retained within the fuel cladding.
- 4.
This renewed operating license shall be deemed to contain and is subject to the conditions specified in the following Commission regulations: 10 CFR Part 20, Section 30.34 of 10 CFR Part 30, Section 40.41 of 10 CFR Part 40, Sections 50.54 and 50.59 of 10 CFR Part 50, and Section 70.32 of 10 CFR Part 70; and is subject to all applicable provisions of the Act and to the rules, regulations, and orders of the Commission now or hereafter in effect; and is subject to the additional conditions specified below:
A. Maximum Power Levels NMC is authorized to operate the facility at reactor core power levels not in excess of 1540 megawatts thermal.
B. Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 222, are hereby incorporated in the renewed operating license.
NMC shall operate the facility in accordance with Technical Specifications.
C. Spent Fuel Pool Modification The licensee' is authorized to modify the spent fuel storage pool to increase its storage capacity from 351 to 1502 assemblies as described in licensee's application dated March 21, 1978, as supplemented and amended. In the event that the on-site verification check for poison material in the poison assemblies discloses any missing boron plates, the NRC shall be notified and an on-site test on every poison assembly shall be performed.
Reference to the licensee in License Conditions 4.C, 4.E and 4.H refers to Wisconsin Electric Power Company and is maintained for historical purposes.
Renewed License No. DPR-24 Admendment No. 222 C. Pursuant to the Act and 10 CFR Parts 30, 40 and 70, NMC to receive, possess and use at any time any byproduct, source, and special nuclear material as sealed neutron sources for reactor startup, sealed source for reactor instrumentation and radiation monitoring equipment calibration, and as fission detectors in amounts as required; D. Pursuant to the Act and 10 CFR Parts 30, 40 and 70, NMC to receive, possess and use in amounts as required any byproduct, source of special nuclear material without restriction to chemical or physical form, for sample analysis or instrument calibration or associated with radioactive apparatus or components; and E. Pursuant to the Act and 10 CFR Parts 30 and 70, NMC to possess such byproduct and special nuclear materials as may be produced by the operation of the facility, but not to separate such materials retained within the fuel cladding.
- 4.
This renewed operating license shall be deemed to contain and is subject to the conditions specified in the following Commission regulations: 10 CFR Part 20, Section 30.34 of 10 CFR Part 30, Section 40.41 of 10 CFR Part 40, Sections 50.54 and 50.59 of 10 CFR Part 50, and Section 70.32 of 10 CFR Part 70; and is subject to all applicable provisions of the Act and to the rules, regulations, and orders of the Commission now or hereafter in effect; and is subject to the additional conditions specified below:
A. Maximum Power Levels NMC is authorized to operate the facility at reactor core power levels not in excess of 1540 megawatts thermal.
B. Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.228, are hereby incorporated in the renewed operating license.
NMC shall operate the facility in accordance with Technical Specifications.
C. Spent Fuel Pool Modification The licensee' is authorized to modify the spent fuel storage pool to increase its storage capacity from 351 to 1502 assemblies as described in licensee's application dated March 21, 1978, as supplemented and amended. In the event that the on-site verification check for poison material in the poison assemblies discloses any missing boron plates, the NRC shall be notified and an on-site test on every poison assembly shall be performed.
Reference to the licensee in License Conditions 4.C and 4.E refers to Wisconsin Electric Power Company and is maintained for historical purposes.
Renewed License No. DPR-27 Admendment No. 228
Programs and Manuals 5.5 5.5 Programs and Manuals 5.5.7 Inservice Testing Program This program provides controls for inservice testing of ASME Code Class 1, 2, and 3 pumps and valves. The program shall include the following:
- a.
Testing frequencies specified in the ASME Code for Operation and Maintenance of Nuclear Power Plants (OM Code) and applicable Addenda are as follows:
ASME OM Code and applicable Addenda terminology for inservice testing activities Semiquarterly Quarterly or every 3 months Yearly or annually Biennially or every 2 years Required Frequencies for performing inservice testing activities At least once per 46 days At least once per 92 days At least once per 366 days At least once per 24 months
- b.
The provisions of SR 3.0.2 are applicable to the above required Frequencies and other normal and accelerated Frequencies, that do not exceed two years, specified in the Inservice Testing Program for performing inservice testing activities;
- c.
The provisions of SR 3.0.3 are applicable to inservice testing activities; and
- d.
Nothing in the ASME OM Code shall be construed to supersede the requirements of any TS.
I Point Beach 5.5-6 Unit I - Amendment No. 222 Unit 2 - Amendment No.