DG-1145, Page C.IV.5-1 C.IV.5. General and Financial Information An application for a combined construction and conditional operating license (COL) for a nuclear power plant should provide the information specified by Title 10, Section 52.77, of the Code of Federal Regulations (10 CFR 52.77), Content of applications; general information. More precisely, for construction permits and operating license applications, the application should address the general and financial information requirements, specified in 10 CFR 50.33, Content of applications; general information.
As discussed in Section C.IV.9, Applicability of Industry Guidance, the Nuclear Energy Institute (NEI) developed Draft Revision E of NEI 04-01, Industry Guideline for Combined License Applicants Under 10 CFR Part 52, which summarizes, in part, the basic information requirements for a COL application. This section provides guidance drawn from NEI 04-01 and augmented by staff input and comments.
C.IV.5.1 General Information The COL application should provide the following general information:
name and address of the applicant description of the business or occupation of the applicant type of license applied for use to which the facility would be put period of time for which the license is sought list of other licenses issued or applied for in connection with the facility information sufficient to demonstrate the applicants financial qualifications to carry out the activities for which the license is sought, including the following:
estimates of the total construction costs and related fuel cycle costs, and sources of funds to cover those costs information showing that the applicant possesses or has reasonable assurance of obtaining the funds necessary to cover estimated construction and related fuel cycle costs information showing that the applicant possesses or has reasonable assurance of obtaining the funds necessary to cover the estimated operating costs for the period of the license estimates of the total annual operating costs for each of the first 5 years of operation, and sources of funds to cover those costs In addition, if the applicant is an individual, the application should contain the citizenship of the applicant.
Alternatively, if the applicant is a partnership, the application should contain the following:
name, address, and citizenship of each partner principal location of the partnership business
DG-1145, Page C.IV.5-2 Similarly, if the applicant is a corporation or unincorporated association, the application should contain the following:
the State where the corporation is organized principal location of the business name, address, and citizenship of each director and principal officer of the corporation or association whether the corporation or unincorporated association is owned, controlled, or dominated by an alien, foreign corporation, or foreign government (if so, the application should provide details)
If the applicant is acting as an agent or representative of another person in filing the application, the applicant should identify the principal and furnish the information described above, as applicable to the individual, partnership, corporation, or unincorporated association.
Applications filed by a newly formed entity organized for the primary purpose of constructing or operating the facility must include the following information:
legal and financial relationships the entity has or proposes to have with its stockholders or owners stockholders or owners financial ability to meet any contractual obligation to the entity that they have incurred or proposed to incur any other information that the Commission considers necessary to enable it to determine the applicants financial qualifications If the applicant proposes to construct the facility, the applicant should state the earliest and latest dates for completion of construction. The applicant should also provide the names and addresses of regulatory agencies that may have jurisdiction over rates and services incident to the proposed activity, as well as a list of trade and news publications that would be appropriate to provide reasonable notice of the application to those municipalities, private utilities, public bodies, and cooperatives that might have a potential interest in the facility.
All restricted and/or defense data developed as part of the application should be separated from the unclassified information.
C.IV.5.2 Commission Activities The Commission will make the following information available on the NRCs public Web site:
a copy of the application copies of subsequent amendments records pertinent to the facility The Commission may request an established utility or newly formed entity to submit additional or more detailed information regarding financial arrangements, and the status of funds, if the Commission considers the information appropriate. This may include information regarding the licensees ability to conduct activities authorized by the license and to complete decommissioning.
1A newly formed entity is a company that has been formed or organized for the primary purpose of constructing, operating, owning, or decommissioning a nuclear power plant, and does not have an established 5-year financial record, or a demonstrated financial capability for raising and managing capital similar to the level required to fund a nuclear power plants construction, capital additions, and operating and decommissioning expenses, as appropriate, or the licensees stipulated share of those operating expenses. A nuclear operating company formed from an existing power reactor licensee or licensees is a newly formed entity.
DG-1145, Page C.IV.5-3 C.IV.5.3 Financial Qualifications The Commissions regulations in 10 CFR 50.33, Contents of applications; general information, require COL applicants to submit financial qualification information to the NRC as part of the COL application. Additional guidance is provided in NUREG-1577,Standard Review Plan on Power Reactor Licensee Financial Qualifications and Decommissioning Funding Assurance, Revision 1.
The COL application should provide information to demonstrate that the applicant either possesses or has reasonable assurance of obtaining the funds necessary to cover estimated construction costs, related fuel cycle costs, and the costs of operation for the period of the license. Appendix C to 10 CFR Part 50 provides more specific information on what is to be provided to support the NRCs financial qualification determination for construction permits.
If one or more of the applicant(s) is a newly-formed entity1, as described in NUREG-1577, Revision 1, the COL application must contain additional information regarding the financial status of each newly formed entity. The additional information required of newly formed entities is prescribed in 10 CFR 50.33, Appendix C to 10 CFR Part 50, and Revision 1 of NUREG-1577.
C.IV.5.4 Decommissioning Funding Assurance Each COL applicant for a power reactor is required to describe in its application how it will provide reasonable assurance that funds will be available to decommission the plant, when required.
10 CFR 50.75 describes the NRCs requirements for decommissioning funding assurance, which differ depending on whether the plant will be operated as a regulated entity in a cost-of-service environment, or as a merchant plant in a competitive market. For example, a merchant plant may not rely exclusively on an external sinking fund to provide decommissioning funding assurance.
C.IV.5.4.1 Estimates of Funding Requirements The COL application must include a report that provides an estimate of total decommissioning costs and applicants funding proposals to cover those costs, as provided in 10 CFR 50.75, Reporting and recordkeeping for decommissioning planning. Each report must contain a certification that financial assurance for decommissioning will be provided in an amount no less than that calculated from the formula given in 10 CFR 50.75. Certification of a higher amount, based on a detailed site-specific analysis, may be made.
The formula amount must be adjusted using escalation factors for energy, labor, and waste burial costs. Decommissioning costs for which funding assurance must be provided do not include the costs of dismantling or demolishing non-radiological systems and structures. Funding assurance need only cover the removal of radiologically contaminated systems and structures, and reduction of residual radioactivity to a level that permits (1) release of the property for unrestricted use and termination of the license, or (2) release of the property under restricted conditions and termination of the license. Also, the costs of managing and storing spent fuel on site until transfer to the U.S. Department of Energy for permanent
DG-1145, Page C.IV.5-4 disposal are not included in decommissioning costs for which there must be funding assurance under 10 CFR 50.75.
Holders of a COL shall annually adjust the minimum amount of decommissioning funding assurance that must be provided using the formula (as required by Section 50.75); however, the actual financial instruments need not be tendered until the Commission has authorized fuel load.
C.IV.5.4.2 Methods for Providing Assurance of Decommission Funding 10 CFR 50.75 allows the following methods for providing financial assurance that decommissioning funding will be available when required.
prepayment deposits into an external sinking fund, escrow account, or government fund that is segregated from the future licensees administrative control, provided that either of the following conditions are met:
The licensee establishes its own rates and thereby recovers all of its decommissioning costs, or is regulated by an external ratemaking authority, such as a public service commission, and recovers all decommissioning costs through traditional cost-of-service ratemaking regulation The licensee receives a Federal or State government-mandated non-bypassable wires charge that will cover all decommissioning costs.
a surety method insurance a parent company guarantee for a Federal licensee, a statement of intent containing a cost estimate for decommissioning and indicating that funds will be available for decommissioning when necessary certain acceptable contractual obligations any other method proposed by the licensee and approved by the NRC, that provides assurance of decommissioning funding equivalent to that provided by the above methods Any of the above methods (or combination thereof ) may be used to provide decommissioning funding assurance, with the exception that, as stated in 10 CFR 50.75(e)(1)(ii)(A) and (B), licensees that are not self-regulated or regulated by a cost-of-service ratemaking authority or whose decommissioning funds are not entirely provided through a non-bypassable wires charge are precluded from relying solely on an external sinking fund.
The estimate of funding provided for in the application may take limited credit for earnings on the decommissioning funds as provided by 10 CFR 50.75. More detailed guidance is provided in Revision 1 of NUREG 1577 and Revision 1 of Regulatory Guide 1.159, Assuring the Availability of Funds for Decommissioning Nuclear Reactors.
C.IV.5.5 Antitrust Requirements
DG-1145, Page C.IV.5-5 The Energy Policy Act of 2005 amended the Atomic Energy Act to eliminate the previous statutory requirement that the NRC must conduct an antitrust review for new applicants to construct or operate utilization or production facilities.
C.IV.5.6 Foreign Ownership Restrictions Foreign ownership, control, or domination of a power reactor licensee is prohibited by Sections 103d and 104d of the Atomic Energy Act and 10 CFR 50.38. The Commission will not issue a license to an applicant if the Commission knows or has reason to believe that the applicant is an alien or is owned, controlled, or dominated by an alien, or by a foreign corporation or foreign government. The Commission must be able to conclude that issuance of a license to an entity (whether or not a foreign ownership or control issue is raised) would not be inimical to the common defense and security or the health and safety of the public.
Some degree of foreign ownership may be allowed under certain circumstances. The principal guidance document is the NRCs Final Standard Review Plan on Foreign Ownership, Control, or Domination (64 FR 52355 et seq., September 28, 1999).
C.IV.5.7 References Nuclear Energy Institute, Industry Guideline for Combined License Applicants Under 10 CFR Part 52, NEI 04-01, Revision E, Draft, October 5, 2005.