Nqoc Le - Fire Doors Page Ngoc Le - Fire Doors Page 11 From:
"Fallin, Michael" <Michael.Fallin @ constellation.com>
To:
"Ngoc Le" <NBL@nrc.gov>
Date:
5/15/06 5:07PM
Subject:
Fire Doors
- Tommy, Relative to our phone conversation, the paragraph we discussed from the "Discussion" Column in the item on ALRA P. 3.3-104 (Item 3.3.1..B-20) was meant to address only those buildings that are not specifically included in the GALL. As such, since the Aux. Bldg fire doors (VII.G.3-d), the DG Bldg fire doors (VII.G.4-d), the Screenwell Bldg fire doors (VII.G.1-d), and the Turbine Bldg fire doors (VII.G.2-d) are specifically addressed in the GALL, those bldgs should not have been included in that paragraph. Only the rated doors for the Reactor Bldg, Control Room Bldg, Essential Yard Structures, Radwaste Bldg, and Standby Gas Treatment Bldg should have been included in the paragraph. The fire doors for those Bldgs are not specifically addressed in the GALL; however, since the material, environment, AERMs, and AMP for those fire doors are the same as GALL Items VII. G.1-d, VII.G.2-d, VII.G.3-d, and VII.G.4-d, they are consistent with the GALL as well. That is what the paragraph was trying to convey.
Similarly, with Item 3.3.1.A-20, the Screen & Pump House and Turbine Bldgs should not have been included in that list of Bldgs in the 1st paragraph of the "Discussion" Column. They are addressed in GALL Items VII.G.1 -d and VII.G.2-d, respectively.
If you have any further questions, give me a call.
Michael R. Fallin Technical Consultant Constellation Generation Group 1997 Annapolis Exchange Parkway Suite 500 Annapolis, MD 21401 (410)897-5165 (ph.)
(315)349-7020 (NMP ph.)
(410)382-4399 (cell)
(410)897-5110 (fax) michael.fallin @constellation.com
>>> This e-mail and any attachments are confidential, may contain legal, professional or other privileged information, and are intended solely for the addressee. If you are not the intended recipient, do not use the information in this e-mail in any way, delete this e-mail and notify the sender. CEG-IP2 CC:
"Mazzaferro, Peter A" <Peter.Mazzaferro@constellation.com>
c:\\temp\\GWJ00001.TMP Page I t c:\\temp\\GW}00001.TMP PaQe ii Mail Envelope Properties (4468ED7A.BDF: 5: 48095)
Subject:
Creation Date:
From:
Created By:
Fire Doors 5/15/06 5:06PM "Fallin, Michael" <Michael.Fallin@constellation.com>
Michael.Fallin @constellation.com Recipients nrc.gov TWGWPOO1.HQGWDOOI NBL (Ngoc Le) constellation.com Peter.Mazzaferro CC (Peter A Mazzaferro)
Post Office TWGWPO01.HQGWDO01 Route nrc.gov constellation.com Date & Time 05/15/06 05:06PM Files MESSAGE TEXT.htm Mime.822 Options Expiration Date:
Priority:
Reply Requested:
Return Notification:
Concealed
Subject:
Security:
Size 1883 3055 6989 None Standard No None No Standard