GARYR. PETERSON m uke Vice President Pa'Energy. McGuire Nuclear Station Duke Energy Corporation MGO1 VP / 12700 Hagers Ferry Rd.
Huntersville, NC 28078 704 875 5333 704 875 4809 fax grpeters~duke-energy. corn May 12, 2006 U. S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555-0001
Subject:
Duke Power Company LLC d/b/a Duke Energy Carolinas, LLC (Duke)
McGuire Nuclear Station Unit 2 Docket No. 50-370 Relief Request (RR) 05-MN-003 Pursuant to 10 CFR 50.55a(a)(3), Duke requests approval to use alternatives to Section XI of the ASME Boiler and Pressure Vessel Code. Compliance with the specified requirements of this section would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety. However, the proposed alternatives will provide an acceptable level of quality and safety. Specific details are described in the attached relief request.
Questions on this matter should be directed to Norman T.
Simms, McGuire Regulatory Compliance, at (704) 875-4685.
Sincerely, G.R. Peterson Attachments www. duke-energy. corn
U.S. Nuclear Regulatory Commission May 12, 2006 Page 2 cc w/attachment:
Mr. W.D. Travers Regional Administrator, Region II U. S. Nuclear Regulatory Commission Atlanta Federal Center 61 Forsyth Street, SW, Suite 23T85 Atlanta, Georgia 30303 Mr. J.F. Stang Jr., Project Manager (addressee only)
Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission One White Flint North, Mail Stop 08-H4A 11555 Rockville Pike Rockville, MD 20852-2738 Mr. J.B. Brady Senior NRC Resident Inspector McGuire Nuclear Station
U.S. Nuclear Regulatory Commission May 12, 2006 Page 3 bxc w/o attachments:
N.T. Simms R. Branch (MGOIWC)
G.J. Underwood (EC05A)
R.K. Rhyne (EC05A)
J.J. Mc Ardle(EC05A)
J.F. Swan (MGO1WC) bxc w/attachments:
K.L. Crane NRIA File/ELL Master File # 1.3.2.13
ATTACHMENT Relief Request 05-MN-003
Request Relief 05-MN-003 Page 1 of 8 Proposed Relief in Accordance with 10 CFR 50.55a(g)(5)(iii),
Inservice Inspection Impracticality Duke Energy Corporation McGuire Nuclear Station - Unit 2 (EOC-16)
Second 10-Year Interval - Inservice Inspection Plan Interval Start Date= December 1, 2001 Interval End Date= December 1, 2011 ASME Section XI Code - 1989 Edition with No Addenda Code Case N460 is applicable Examination Dates October 6, 2003-April 14, 2005
- 1. IL IL. IV. & V. VL V VIIL Request inmited System / Code Requirement from Which Relief is Impracticality/ Proposed Implementation Justification for Number Area/Weld LD. Component for Which Relief is Requested: Burden Caused Alternate Schedule and Granting Relief Number Requested: 100% Exam Volume Coverage by Compliance Examinations or Duration Area or Weld to be Examined Exam Category Testing Item No.
Fig. No.
Limitation Percentage ___
- 1. 2RPV-W03 NC System Exam Category B-A See Paragraph See Paragraph "E" See Paragraph See Paragraph Reactor Vessel Lower Shell to Lower Item No. BO1.01 1.003 "A" "Ff""
Head Circumferential Weld Fig. IWB-2500-1 See Attachment I See Attachment I 72.76% Volume Coverage Pages 1-40 Pages 1-40 Attachment 6 Attachment 6 Page 1 Page l
- 2. 2RPV-WO1 NC System Exam Category B-A See Paragraph See Paragraph "E" See Paragraph See Paragraph Reactor Vessel Lower Head to Bottom Item No. BO1.021.002 "B" "F' "H" Head Circumferential Weld Fig. IWB-2500-3 See Attachment 2 See Attachment 2 87.19% Volume Coverage Pages 1-81 Pages 1-81 Attachment 6 Attachment 6 Page 2 Page 2
- 3. 2RPV-W15-SE NC System Exam Category B-F See Paragraph See Paragraph "E' See Paragraph See Paragraph -r' Reactor Vessel Outlet Nozzle to Safe Item No. B05.010.005 and B05.010.005A "C" "F" See Attachment 3 End Weld (22 degrees) Fig. IWB-2500-8 See Attachment 3 Pages 1-7 84.38% Volume Coverage Pages 1-7 Attachment 6 Attachment 6 Page 3 Page 3
- 4. 2RPV-W17-SE NC System Exam Category B-F See Paragraph See Paragraph "E" See Paragraph See Paragraph "1r Reactor Vessel Outlet Nozzle to Safe Item No. B05.010.007 and B05.010.007A "C" "F" See Attachment 4 End Weld (202 degrees) Fig. IWB-2500-8 See Attachment 4 Pages 1-7 80.24% Volume Coverage Pages 1-7 Attachment 6 Attachment 6 Page 3 Page 3
Request Relief 05-MN-003 Pa e2of8 L IL [IL IV. & V. VW. VIL VIIl.
Request ULmited System I Code Requirement from Which Relief is Impracticality Proposed Implementation Justification for Number Area/Weld LD. Component for Which Relief is Requested: 100% Exam Volume Burden Caused Alternate Schedule and Granting Relief Number Requested: Coverage by Compliance Examinations Duration Area or Weld to be Examined Exam Category or Testing Item No.
Fig. No.
Limitation Percentage
- 5. 2RPV-W18-SE NC System Exam Category B-F See Paragraph "C" See Paragraph See Paragraph See Paragraph -r, Reactor Vessel Outlet Nozzle to Safe Item No. B05.010.008 and B05.010.008A See Attachment 5 "F' "F' See Attachment 5 End Weld (338 degrees) Fig. 1WB-2500-8 Pages 1-7 Pages 1-7 83.34%/a Volume Coverage Attachment 6 Attachment 6 Page 3 Page 3
- 6. 2NC2F-I-1 NC System Exam Category B-F See Paragraph See Paragraph See Paragraph See Paragraph Reactor Vessel Outlet Nozzle to Safe Item No. B05.130.001 and B05.130.001A y"F' "F' Ifr End (22 degrees) Fig. IWB-2500-8 See Attachment 3 See Attachment 3 (Pipe Side Scan) 84.38% Volume Coverage Pages 1-7 Pages 1-7 Attachment 6 Attachment 6 Page 3 Page 3
- 7. 2NC2F-3-1 NC System Exam Category B-F See Paragraph See Paragraph See Paragraph See Paragraph Reactor Vessel Outlet Nozzle to Safe Item No. B05.130.009 and B05.130.009A " D" "f' "F' End (202 degrees) Fig. IWB-2500-8 See Attachment 4 See Attachment 4 (Pipe Side Scan) 80.24% Volume Coverage Pages 1-7 Pages 1-7 Attachment 6 Attachment 6 Page 3 Page 3
- 8. 2NC2F-4-1 NC System Exam Category B-F See Paragraph See Paragraph See Paragraph See Paragraph Reactor Vessel Outlet Nozzle to Safe Item No. B05.130.013 and B05.130.013A "D" "F' 'T' End (338 degrees) Fig. IWB-2500-8 See Attachment 5 See Attachment 5 (Pipe Side Scan) 83.34% Volume Coverage Pages 1-7 Pages 1-7 Attachment 6 Attachment 6 Page 3 Page 3
Request Relief 05-MN-003 Page 3 of 8 IV. & V. Impracticality/Burden caused by Code Compliance Paragraph A: (The Reactor Vessel Lower Shell to Lower Head Circumferential Weld is carbon steel. The thickness of this weld is 5.300 inches.)
During the ultrasonic examination of this weld, 100% coverage of the required examination volume could not be obtained. Coverage was limited due to the proximity of six Core Support Lugs. Scanning was conducted between and below the obstructing lugs with the scan boundaries maximized by visually assisted positioning of the exam head so that scan starts and stops were as close to the support lugs as tool configuration allowed. Beam angles dual element 45 degree refracted L-wave, single element 45 degree L-waves and single element 45 Shear Wave were used for this examination. This percentage represents the aggregate coverage of all scans performed on the weld and base material. In order to achieve more coverage, the six Core Support Lugs would have to be moved to allow greater access for scanning, this would be impractical. There were no recordable indications found during the inspection of this weld.
Paragraph B: (The Reactor Vessel Lower Head to Bottom Head Circumferential Weld is carbon steel. The thickness of this weld is 5.300 inches.)
During the ultrasonic examination of this weld, 100% coverage of the required examination volume could not be obtained. Coverage was limited due to the Lower Head to Bottom Head Weld being at approximately the same position as the peripheral bottom mounted instrumentation tubes (BMI). Scanning was conducted above and between the obstructing penetrations with scan boundaries maximized by visually assisted positioning of the exam head so that scan starts and stops were as close to the tubes as tool configuration allowed. The amount of coverage reported represents the aggregate coverage from all scans performed on the weld and base material. Beam angles, dual element 45-degree L-wave, single element 45 degree L-wave and single element 45 Shear Wave were used for this examination. This percentage represents the aggregate coverage of all scans for the weld. In order to achieve more coverage, the bottom mounted instrumentation tubes would have to be moved to allow greater access for scanning, this would be impractical. There were no recordable indications found during the inspection of this weld.
Paragraph C: (The Reactor Vessel Outlet Nozzle to Safe End Weld is stainless steel to carbon steel. The diameter of the weld is 29.00 inches with a wall thickness of 2.312 inches.)
During the ultrasonic examination of this weld, 100% coverage of the required examination volume could not be obtained. Coverage was limited due to the ID configuration which consists of counter-bore and weld root protrusion.
Ultrasonic scans were performed from the ID surface using 70 degree L wave transducers applied in four directions. This exam interrogated the inner 1/3 thickness volume. Eddy Current examination was also employed to examine inner surfaces of the dissimilar metal welds and the
Request Relief 05-MN-003 Page 4 of 8 adjacent examination volumes where ID geometry presented a limitation to the detection of axial flaws as defined in the PDQS for the qualified Appendix VIII techniques.
Paragraph D: The Reactor Vessel pipe to safe end weld is stainless steel. The diameter of the weld is 29.000 inches with a wall thickness of 2.300 inches.)
During the ultrasonic examination of this weld, 100% coverage of the required examination volume could not be obtained. Coverage was limited due to the ID configuration which consists of counter-bore and weld root protrusion.
Ultrasonic scans were performed from the ID surface using 70 degree L wave transducers applied in four directions. This exam interrogated the inner 1/3 thickness volume. Eddy Current examination was also employed to examine inner surfaces of the similar metal welds and the adjacent examination volumes where ID geometry presented a limitation to the detection of axial flaws as defined in the PDQS for the qualified Appendix VIII techniques.
VI. Proposed Alternate Examinations or Testing Paragraph E:
None. The scheduled 10-year code examination was performed on the referenced area/welds and it resulted in the noted limited coverage of the required ultrasonic volume. No additional examinations are planned for the area/weld during the current inspection interval.
VII. Implementation Schedule and Duration Paragraph F:.
None. The scheduled 10-year code examination was performed on the referenced area/welds and it resulted in the noted limited coverage of the required ultrasonic volume. No additional examinations are planned for the area/weld during the current inspection interval.
VIII. Justification for Granting Relief Paragraph G: Ultrasonic examination of this weld was conducted using personnel, equipment and procedures qualified in accordance with ASME Section XI, Appendix VIII, 1995 Edition with the 1996 Addenda as modified by 10 CFR 50.55a(b)(2)(xiv, xv and xvi). Although 100%
coverage of the examination volume could not be achieved, the amount of coverage obtained for this examination provides an acceptable level of quality and integrity.
Due to the design of the reactor vessel and location of the Core Guide Lugs it is not feasible to obtain the required examination coverage. This weld is not exposed to significant neutron fluence and is not prone to negative material property changes (i.e., embrittlement) associated with neutron bombardment. If a leak were to occur at the weld in question, there are methods by
Request Relief 05-MN-003 Page 5 of 8 which the leak could be identified for prompt Engineering evaluation. The plant is designed to detect the following:
a) Increased containment humidity. This parameter is indicated in the control room and is monitored periodically by Operations and also monitored by the Containment Ventilation System Engineer. Lower containment humidity, Ventilation Unit Condensate Drain Tank (VUCDT) level, are all recorded in Autolog at the start of each shift.
b) Increased temperatures in lower containment, Steam Generator compartment, Pressurizer compartment, or incore sump room. These temperatures are monitored continuously by the OAC alarms, and are periodically monitored by the System Engineer. The OAC alarm is set for immediate Operations notification when an alarm set point is exceeded.
c) Increased input into the VUCDT level. This parameter is monitored continuously by Operations via an OAC alarm and also periodically by the Liquid Radwaste System Engineer and Reactor Coolant System Engineer. The OAC alarm is set for immediate Operations notification when an alarm set point is exceeded.
d) Increase in unidentified reactor coolant leakage. This parameter would be exhibited during performance of reactor coolant leakage calculation, which is required by Technical Specifications to be performed every 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />. The unidentified leakage limit in Technical Specification 3.4.13.1 is 1 gpm.
e) Increased Containment Floor and Equipment Sump levels. These levels are monitored continuously by the OAC alarms for immediate Operations notification, and are periodically monitored by the System Engineer.
f) Change in the Volume Control Tank (VCT) level rate (a more negative rate is set to alarm to Operations at -1.0 gpm). This is closely monitored by the Chemical and Volume Control System Engineer.
Note: Although diverse means are available to identify a leak in containment, containment entry would be required to identify the exact source of the leakage.
In addition, a Mode 3 containment walkdown is performed each refueling outage at shutdown and startup to identify any leaks.
Paragraph H: Ultrasonic examination of this weld was conducted using personnel, equipment and procedures qualified in accordance with ASME Section XI, Appendix VIII, 1995 Edition with the 1996 Addenda as modified by 10 CFR 50.55a(b)(2)(xiv, xv and xvi). Although 100%
coverage of the examination volume could not be achieved, the amount of coverage obtained for this examination provides an acceptable level of quality and integrity.
Due to the design of the reactor vessel and location of the bottom mounted instrumentation (BMI) tubes it is not feasible to obtain the required examination coverage. This weld is not exposed to significant neutron fluence and is not prone to negative material property changes (i.e., embrittlement) associated with neutron bombardment. If a leak were to occur at the weld in
Request Relief 05-MN-003 Page 6 of 8 question, there are methods by which the leak could be identified for prompt Engineering evaluation. The plant is designed to detect the following:
- a. Increased containment humidity. This parameter is indicated in the control room and is monitored periodically by Operations and also monitored by the Containment Ventilation System Engineer. Lower containment humidity, Ventilation Unit Condensate Drain Tank (VUCDT) level are all recorded in Autolog at the start of each shift.
- b. Increased temperatures in lower containment, Steam Generator compartment, Pressurizer compartment, or incore sump room. These temperatures are monitored continuously by the OAC alarms, and are periodically monitored by the System Engineer. The OAC alarm is set for immediate Operations notification when an alarm set point is exceeded.
- c. Increased input into the VUCDT level. This parameter is monitored continuously by Operations via an OAC alarm and also periodically by the Liquid Radwaste System Engineer and Reactor Coolant System Engineer. The OAC alarm is set for immediate Operations notification when an alarm set point is exceeded.
- d. Increase in unidentified reactor coolant leakage. This parameter would be exhibited during performance of reactor coolant leakage calculation, which is required by Technical Specifications to be performed every 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />. The unidentified leakage limit in Technical Specification 3.4.13.1 is 1 gpm.
- e. Increased Containment Floor and Equipment Sump levels. These levels are monitored continuously by the OAC alarms for immediate Operations notification, and are periodically monitored by the System Engineer.
- f. Change in the Volume Control Tank (VCT) level rate (a more negative rate is set to alarm to Operations at 1.0 gpm). This is closely monitored by the Chemical and Volume Control System Engineer.
Note: Although diverse means are available to identify a leak in containment, containment entry would be required to identify the exact source of the leakage.
In addition, a Mode 3 containment walkdown is performed each refueling outage at shutdown and startup to identify any leaks.
Request Relief 05-MN-003 Page 7 of 8 Paragraph I:
Ultrasonic examination of this weld was conducted using personnel, equipment and procedures qualified in accordance with ASME Section XI, Appendix VIII, 1995 Edition with the 1996 Addenda as modified by 10 CFR 50.55a(b)(2)(xiv, xv and xvi). Although 100% coverage of the examination volume could not be achieved, the amount of coverage obtained for this examination provides an acceptable level of quality and integrity.
Due to the ID configuration counter-bore and weld root protrusion, it is not feasible to obtain the required examination coverage. This weld is not exposed to significant neutron fluence and is not prone to negative material property changes (i.e., embrittlement) associated with neutron bombardment. If a leak were to occur at the welds in question, there are methods by which the leak could be identified for prompt Engineering evaluation. The plant is designed to detect the following:
- a. Increased containment humidity. This parameter is indicated in the control room and is monitored periodically by Operations and also monitored by the Containment Ventilation System Engineer. Lower containment humidity, Ventilation Unit Condensate Drain Tank (VUCDT) level are all recorded in Autolog at the start of each shift.
- b. Increased temperatures in lower containment, Steam Generator compartment, Pressurizer compartment,'or incore sump room. These temperatures are monitored continuously by the OAC alarms, and are periodically monitored by the System Engineer. The OAC alarm is set for immediate Operations notification when an alarm set point is exceeded.
- c. Increased input into the VUCDT level. This parameter is monitored continuously by Operations via an OAC alarm and also periodically by the Liquid Radwaste System Engineer and Reactor Coolant System Engineer. The OAC alarm is set for immediate Operations notification when an alarm set point is exceeded.
- d. Increase in unidentified reactor coolant leakage. This parameter would be exhibited during performance of reactor coolant leakage calculation, which is required by Technical Specifications to be performed every 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />. The unidentified leakage limit in Technical Specification 3.4.13.1 is 1 gpm.
- e. Increased Containment Floor and Equipment Sump levels. These levels are monitored continuously by the OAC alarms for immediate Operations notification, and are periodically monitored by the System Engineer.
- f. Change in the Volume Control Tank (VCT) level rate (a more negative rate is set to alarm to Operations at 1.0 gpm). This is closely monitored by the Chemical and Volume Control System Engineer.
Note: Although diverse means are available to identify a leak in containment, containment entry would be required to identify the exact source of the leakage.
In addition, a Mode 3 containment walkdown is performed each refueling outage at shutdown and startup to identify any leaks.
Request Relief 05-MN-003 Page 8 of 8 IX. Other Information Jim McArdle (Principal UT NDE Level III Examiner) provided Sections III., IV., V. and part of Section VIII.
Robert W. Kirk (MNS Systems Engineer) provided part of Section VIII.
Gary Underwood (Sponsor) compiled the remaining sections of this relief request.
Sponsored By: 4o-_ Date 5s Lo - OM Approved By: :i I]1 -f-. Date 5//&#O Attachment 1, 6 UT Examination Data BO1.01 1.003 Attachment 2, 6 UT Examination Data BO1.021.002 Attachment 3, 6 UT Examination Data B05.010.005 and B05.010.005A Attachment 4, 6 UT Examination Data B05.010.007 and B05.010.007A Attachment 5, 6 UT Examination Data B05.010.008 and B05.010.008A Attachment 3, 6 UT, Examination Data B05.130.001 and B05.130.00IA Attachment 4, 6 UT, Examination Data B05.130.009 and B05.130.009A Attachment 5, 6 UT, Examination Data B05.130.013 and B05.130.013A
REQUEST RELIEF 05-MN-003 ATTACHMENT 1 PAGES 1-40
PActLj r I WesDyne International Reactor Vessel Weld Results Summary McGUIRE UNIT 2 WELD NO. 2RPV-W03 DESCRIPTION Lower Shell to Lower (B01.011.003) Head Circ LIMITATIONS NO - YES Wx COVERAGE = 72.76%
RESULTS NO. OF INDICATIONS 0 STATUS N/A EXAM DOCUMENTATION INDICATION DOCUMENTATION
[x] ANALYSIS LOG D- ASSESSMENT SHEET i ACQUISITION LOG FII PARAGON HARD COPY
[x] SCAN PRINTOUT -DOTHER ( specify )
[n COVERAGE BREAKDOWN WESDYNE ANALYST
McGuire Unit 2 DIRECTION / ORIENTATION RPV COVERAGE ESTIMATE BREAKDOWNS PARALLEL SCANS CCW/CW PERP. SCANS UP/DN WELD LOWER SHELL TO LOWER HEAD WELD NO. 2RPV-W03 DESCRIPTION CIRC WELD BEAM ANGLES BEAM 450 L Dual 450 L Single 450 Shear DIRECTION WELD VOLUME WELD VOLUME WELD VOLUME WELD VOLUME WELD VOLUME CCW 63.67 22.0 100 80.02 100 80.02 CW 63.67 22.0 100 80.02 100 80.02 UP 63.67 63.67 63.67 63.67 81.83 100 DOWN 63.67 63.67 63.67 63.67 63.67 100 Combined Average = 72.76% Limitation due to Core Support Lugs.
ANALYST <*4'
PLANT I UNIT McGUIRE 12 OPTICAL DISK #
S yn1 "W PROCEDURE: PD14SI-254 REVISION: 7 WELD # WELD TYPE:
2RPV-W03 LOWER SHELL TO LOWER HEAD CIRC ANALYSIS LOG Calibration Data Sheet No. LS1 - LS8 Acquisition Log Sheet No. W4-1 Analysis Log Sheet No. W4-1 W4&PAR-47-72 I 45L I CCW X CHL 3M18105 W4-PAR-47-72 2 45L I CW X CHL 3118105 W4&PAR 47-72 3 45L I CCW X CHL 3118105 W4-PAR.47-72 4 45L I CW X CHL 3118105 W4PAR-47-72 S 45S I CCW X CHL 3118105 W4&PAR-47-72 6 45S / CW X CHL 3/18105 W4PAR-47-72 7 45S I CW X CHL 3/18105 W4-PAR-47-72 8 45L I CCW X CHL 311805 W4&PAR-72-107 I 45L I CCW X CHL 3M18105 W4-PAR-72-107 2 451. I CW X CHL 3118105 W4&PAR-72-107 3 45L I CCW X CHL 3118105 W4-PAR-72-107 4 45L I CW X CHL 3/18105 W4-PAR-72-107 a 45S I CCW X CHL 3118105 W4-PAR-72-107 6 45S I CW X CHL 3118105 W4&PAR-72-107 7 45L I CW X CHL 3/18105 W4&PAR-72-107 8 45L I CCW X CHL 3/18105 EXAINR EVL lLDAE 3-~'O_
EXAMiNER LEVEL wL DATE 03 - Ig8-°t
PLANT I UNIT McOUIRE /2 OPTICAL DISK U N W ESDY nK PROCEDURE: PDI4IS-2S4 REVISION: 7 WELD# WELD TYPE:
2RPV-W03 LOWER SHELL TO LOWER HEAD CIRC ANALYSIS LOG Calon Data Sheet No. LSI - LS8 Acqulsition Log Shet No. W4-1
.Aalyis Log Sheet No. W4_2 W4-PAR-12-47 I 4SLD / CCW X LMM 3118105 W4-PAR-12-47 2 45LD/ CCW X LMM 3118105 W4-PAR-12-47 3 45LS I CCW X LMM 3118105 W4-PAR-12-47 4 45LS I CW X LMM 3118105 W4-PAR-12 47 5 45S/ CCW X LMM 3118/05 W4-PAR-12-47 6 45S I CW X LMM 3118105 W4-PAR-12-47 7 458/ CCW X LMM 3/18105 W4-PAR-12-47 8 45LD I CCW X LMM 3118105 W4-PAR-132-167 I 45LD I CCW X LMM 3118105 WWPAR-132-167 2 45LD I CW X LMM 3M8105 W4-PAR-132-167 3 45LS CCW X LMM 3M18105 W4PAR-132-167 4 451S/ CCW X LMM 3M18105 W4&PAR-132-167 5 45S/ CCW X LMM 3M8105 W4-PAR-132-167 6 45L / CW X LMM 3M8105 W4&PAR-132-167 7 45L I CW X LMM 3M8105 W4-PAR-132-197 8 45LD I CCW X LMM 3/18105 EXAMINER
-u6'.-I/Jk2AJAAAJ LEVEL DATE 3__-/8-os
PLANT I UNIT McGUIRE 12 OPTICAL DISK #
N yNE PROCEDURE: PDI-S254 REVISION: 7 WELD 1 WELD TYPE:
2RPV-W03 LOWER SHELL TO LOWER HEAD CIRC ANALYSIS LOG Calbmation Dta Sheet No. LSI - LS8 Acquisition Log Sheet No. W4-1
__ ___ __ __ __ __ __ Analysis Log Sheet No. W4-3 W4-PAR-167-192 I 45LD I CCW X LMM 3118105 W4-PAR-1674192 2 45LD I CW X LMM 3M18105 W4PAR-167-192 3 45W I CCW X .LMM 3M8105 W4-PAR-167-192 4 45LS / CW X LMM 3M8105 W4-PAR-167-192 5 45S / CCW X LMM 3118/05 W4-PAR-167-192 46S I CW X LMM 3/18/05 W4-PAR-167-192 7 45S I CW X LMM 318105 W4-PAR-167-192 8 45LD I CCW X LMM 3/1810S W4&PAR-347-12 I 45LD I COW X LMM 3118/05 W4-PAR-347-12 2 45LD I CW X LMM 3M8105 W4-PAR-347-12 3 45WS I COW X LMM 3118105 W4-PAR-347-12 4 45LS I COW X LMM 3118105 W4&PAR-347-12 45SI CCW X LMM 3118105 W4-PAR-347-12 6 45S OCW X LMM 3118/05 W4-PAR-347-12 7 45L I CW X LMM 3118105 W4-PAR-347-12 8 45LD I CCW X LMM 311805 a a a - a EXAMINER l4<4Alj-A'~.ZI"AAd'gA#
- LEVEL .
DATE 3 -/0-os (i 61
PLANT I UNIT McGUIRE 12 OPTICAL DISK 0 N
so WI NWAT~I m* AL PROCEDURE: PDI4SI-254 REVISION: 7 WELD# WELD TYPE:
2RPV-W03 LOWER SHELL TO LOWER HEAD CIRC ANALYSIS LOG Callbration Data Sheet No. LS1 - LS8 Acquisfilon Log Sheet No. W4-1 Analysis Log Sheet No. W4-4 W4-PAR.107-132 I 45L I CCW X CHL 3118105 W4-PAR-107-132 2 45L/ CW X CHL 3118105 W4-PAR-107-132 3 46LICCW X CHL 3/18/05 W4-PAR-107-132 4 45LICW X CHL 3118105 W4-PAR-107-132 5 45S / CCW X CHL 3M8105 W4-PAR-107-132 6 45/ CW X CHL 3118105 W4-PAR-107-132 7 45SI CW X CHL 3118105 W4-PAR-107-132 8 45L I CCW X CHL 3118105 W4-PAR-227-252 I 45L I CCW X CHL 3118105 W4-PAR-227-252 2 45L1 CW X CHL 3118105 W4&PAR-227-252 3 45L/ CCW X CHL 3118105 W4-PAR-227-252 4 45L/ CW X CHL 3118105 W4&PAR-227-252 5 45S! CCW X CHL 3118105 W4-PAR-227-252 6 45SI CW X CHL 3118105 W4-PAR-227-252 7 45S/ CW X CHL 3118105 W4-PAR-227-252 8 46LICCW X CHL 3118105 a -
EXAMINER 11and 014um
, -, -,. LIM LEVEL - DATE /4-4Or
PLANT I UNIT McGUIRE 12 OPTICAL DISK #
PROCEDURE: PDI451-254 REVISION: 7 WLD # WELD TYPE:
2RPV-W03 LOWER SHELL TO LOWER HEAD CIRC ANALYSIS LOG Calibration Data Sheet No. LSI - LS8 Acquisiton Log Sheet No. W4-1 Analyis Log Sheet No. W4-5 W4-PAR-197-227 1 45L I GUW x CHL 318105 W4-PAR-197-227 2 4.L I CW X CHL 3118105 W4&PAR-197-227 3 45L I CCW X CHL 3118105 W4-PAR-197-227 4 45L I CW X CHL 3M8105 W4-PAR-197-227 5 45 I CCW X CHL 3118105 W4-PAR-197-W227 6 45 I CW X CHL 3118105 W4-PAR-197-227 7 45S I CW X CHL 311815 W4-PAR-197-27 8 45L I CCW X CHL 3/18105 W4-PAR-252227 I 45L I CCW X CHL 311805 W4-PAR-252-7 2 45LI CW X CHL 3118105 W4-PAR-252-287 3 45L I CCW X CHL 3/18105 W4-PAR-252-287 4 45L I CW X CHL 3M18105 W4-PAR-252-287 5 45 I CCW X CHL 3/18105 W4-PAR-252-287 6 45S I CW X CHL 3118105 W4-PAR-252-287 7 45S I CW X CHL 3M8105 W4-PAR-252-287 8 45L I CCW X CHL 3118105
- I t I U.
9 9 I t 9 5.
a a I- a a DATE 5.
EXAMINER jIEXAMINER rhalla. i4lix Lee Lee LEVEL LEVEiL DATE 0 5-/,f-,O
-, - " T .-- - _
PLANT I UNIT MCGUIRE /2 OPTICAL DISK #
PROCEDURE: PD14I31-24 REVISION: 7 WELD# WELD TYPE:
2RPV-W03 LOWER SHELL TO LOWER HEAD CIRC ANALYSIS LOG Calibration Data Sheet No. LS1 - LS8 Acquisition Log Shee No. W4-1
, Analysis Log Sheet No. W4-6 W4-PRP-2M0-289 I 46LD I ON X LMM 3118105 W4-PRP-250-289 2 46LD I UP X LMM 3118105 W4-PRP-250-289 3 45L I ON X LMM 3M8105 W4-PRP-250-289 4 45LS I UP X LMM 3118105 W4-PRP-250-289 6 45S /DN X LMM 3/1B105 W4-PRP-250-289 6 45SI UP X LMM 3118105 W4-PRP-250-289 7 45SI UP X LMM 3118105 W4-PRP-250-289 8 45LD I ON X LMM 3118105 W4-PRP-289-310 I 45LD I ON X LMM 3M8t05 W4-PRP-289"310 2 45LD I UP X LMM 3M18105 W4-PRP-289-310 3 45LS I ON X LMM 3/18105 W4-PRP-289-310 4 45L I UP X LMM 3M8105 W4-PRP-289-310 5 45SION X LMM 3M8105 W4-PRP-289-310 6 45S/ UP X LMM 3118105 W4-PRP-289"310 7 45S/UP X LMM 3M8105 W4-PRP-289-310 a 45LS I ON X LMM 3/18105 EXAMINER ,4gAl,J 9&-,j 0A&G~ LEVEL DATE _ . _
-61
PLANT I UNIT McGUIRE 12 OPTICAL DISK #
I Wl PROCEDURE: PDI41I254 REVISION: 7 WELD# WELD TYPE:
2RPV-W.3 LOWER SHELL TO LOWER HEAD CIRC ANALYSIS LOG Callbration Data Sheet No. LSI - LS8 Acquisition Log Sheet No. W4-1
. Analysis Log Sheet No. W4-7 W4-PAR-287-312 I 45L I CCW X CHL 3118105 W4-PAR-287-312 2 45L I CW X CHL 3M8105 W4-PAR-287-312 3 45L I CCW X CHL 3M8105 W4-PAR-287-312 4 45S I CW X CHL 3118105 W4-PAR-287-312 7 45S I CCW X CHL 3118105 W4-PAR-287-312 6 45L/ CCW X CHL 3118105 W4-PAR-M-312 7 45L I CW X CHL 3118105 W4-PAR-7-312 8 45L I CCW X CHL 3118105 W4-PAR-312-347 I 45L I CCW X CHL 3M8105 W4-PAR-312-347 2 45L I CW X CHL 3118105 W4-PAR-312-347 3 45S I CCW X CHL 3118105 W4&PAR-312-347 4 45L I CW X CHL 3118105 W4-PAR-312-347 5 45SI CCW X CHL 3M18105 W4-PAR-312-347 6 453 / CW X CHL 3118105 W4-PAR-312-347 7 45SI CW X CHL 3118105 W4-PAR-312-347 8 45L CCW X CHL 3118/05 EXAMINER L.-fiIA FIJ IU M -r LEVEL _ DATE
PLANT I UNIT McGUtRE 12 OPTICAL DISK 1 m PROCEDURE: PD14t1-254 REVISION: 7 WELD 8 WELD TYPE:
2RPV-W03 LOWER SHELL TO LOWER HEAD CIRC ANALYSIS LOG Calibration Data Sheet No. LS1 - LS8 Acquisition Log Sheet No. W4-1 Analysis Log Sheet No. W4-8 W4-PRP-190-229 I 45L I DN X CHL 3118105 W4-PRP-190-229 2 45L I UP X CHL 3118105 W4-PRP-190-229 3 45L I DN X CHL 3M8/05 W4-PRP-190-229 4 45L I UP X CHL 3M8105 W4-PRP-190-229 5 45S I DN X CHL 3M8105 W4-PRP-190-229 6 4531 UP X CHL 3M18/05 W4.PRP-190-229 7 45S I UP X CHL 3118105 W4-PRP-190-229 8 45L I DN X CHL 3118105 W4-PRP-229-250 I 45L I DN X CHL 3M8105 W4-PRP-229-250 2 45L / UP X CHL 3118105 W4-PRP-229-250 3 45L I ON X CHL 3118105 W4-PRP-229-250 4 45L I UP X CHL 3M8105 W4-PRP-229-250 6 45S I ON X CHL 3118105 W4-PRP-229-250 6 45S I UP X CHL 3118105 W4-PRP-229-250 7 45SI UP X CHL 3118105 W4-PRP-29-250 8 45L I DN X CHL 3118105 EXAINR EVL AT EXAMINER rIlwa Auln
= 'Ifj -
Lee LEVEL I- DATE 03 -/I -5
PLANT I UNIT McGUIRE 12 OPTICAL DISK #
N WKSDynE Imp.. NAYf. .. I PROCEDURE: PDI4SI-2S4 REVISION: 7 WELD # WELD TYPE:
2RPV-W03 LOWER SHELL TO LOWER HEAD C.RC ANALYSIS LOG Cabration Data Sheet No. LSI - LS8 Acquisition Log Sheet No. W4-1 Analysis Log Sheet No. W4-9 aa- -
W4-PRP-310-349 I 45LD I DN X LMM 3M9105 W4-PRP-310-349. 2 4LD I UP X LMM 319105 W4-PRP-310-349 3 45LD I ON X LMM 3119105 W4&PRP-310-349 4 45L I UP X LMM 3119105 W4-PRP-310-349 5 45S I DN X LMM 3119105 W4-PRP-310-349 6 45S I UP X LMM 3119105 W4-PRP-310-349 7 45S I UP X LMM 3119105 W4-PRP-310-349 8 45LD / N X LMM 3119105 W4-PRP-49-70 I 45LD I DN X LMM 3119105 W4-PRP-49-70 2 45LD I UP X LMM 3M9105 W4-PRP-49-70 3 45L I DN X LMM 3119105 W4-PRP-49-70 4 45LS I UP X LMM 3119105 W4-PRP.49-70 5 4LS I ON X LMM 3119105 W4-PRP-49-70 6 45S I UP X LMM 3M9105 W4-PRP-49-70 7 45S I UP X LMM 3M9105 W4-PRP-49-70 8 45LD I ON X LMM 3M19/05 EXAMINER fA&AA.- A a
0iZJ4AAA&AL0 -
LEVEL zz DATE S5I-s 6'
V C/
PLANT I UNIT MCGUiRE 12 OPTiCAL DISK #
N YEN PROCEDURE: PD 4 1-254 REVISION: 7 WELD # WELD TYPE:
2RPV-W03 LOWER SHELL TO LOWER HEAD CIRC ANALYSIS LOG Calibration Data Sheet No. LS1 - LS8 Acquisftlon Log Sheet No. W4-1 Analysis Log Sheet No. W4.10 W4&PRP-349-10 I 45L I DN X CHL 3119105 W4-PRP-349-10 2 45L I UP X CHL 3119O5 W4-PRP-349-10 3 45L I DN X CHL 3119/05 W4&PRP-349-10 4 45L I UP X CHL 3M9/05 W4-PRP-349-10 5 45S I DN X CHL 3M9105 W4-PRP-349-10 6 45S I UP X CHL 3119105 W4-PRP-349-10 7 45S I UP X CHL 3M9105 W4-PRP-349-10 8 45L I DN X CHL 3M19105 W4-PRP-10-49 I 45L I DN X CHL 3M19105 W4-PRP-10.49 2 45L I UP X CHL 3119105 W4-PRP-10-49 3 45L I DN X CHL 3M9105 W4-PRP-10-49 4 45L I UP X CHL 3119105 W4-PRP-10.49 5 45S I DN X CHL 3M9105 W4-PRP-10-49 6 45S I UP X CHL 3119105 W4.PRP-1049 7 45S I UP X CHL 3119105 W4-PRP-10-49 a 45L / DN X CHL 3M9105 EXAMINER t czhmg Am e LEVEL DATE Os_/_ __
PLANT I UNIT McOUIRE 12 OPTICAL DISK #
,.,O .ATI ONA L IWSfE PROCEDURE: PDI-1254 REVISION: 7 WELD # WELD TYPE:
2RPV-W03 LOWER SHELL TO LOWER HEAD CIRC ANALYSIS LOG Calibration Data Sheet No. LS1 - LS8 Acquisition Log Shee No. W4-1 Analysis Log Sheet No. W411 W4-PRP-70-109 I 45LD I ON X LMM 3119105 W4-PRP-70-109 2 45LD / UP X LMM 3M19/05 W4-PRP-70-109 3 45LS I ON X LMM 3119105 W4-PRP-70-109 4 45iS UP X LMM 3M9105 W4-PRP-70-109 5 45S / ON X LMM 3M19105 W4-PRP-70-109 6 45S / UP X LMM 3/19105 W4-PRP-70-109 7 45S/UP X LMM 3/19105 W4-PRP-70-109 8 45LD / ON X LMM 3/19105 W4-PRP-109-130 I 45LD/ DN X LMM 3/19/05 W4-PRP-109-130 2 45LD I UP X LMM 3M9105 W4-PRP-109-130 3 45LS I ON X LMM 3M9105 W4-PRP4109-130 4 45LS / UP X LMM 3/19105 W4-PRP-109-130 5 45S I DN X LMM 3/19105 W4-PRP-109-130 6 45S / UP X LMM 3/19105 W4-PRP-109-130 7 45S / UP X LMM 3M9105 W4-PRP-109-130 8 45LD f ON X LMM 3/19105 EXAMINER 9k LEVEL LVEL DATE3-9o DAATE
PLANT I UNIT McGUIRE 12 OPTICAL DISK#
N W S I PROCEDURE: PD14SI-254 REVISION: 7 WELD # WELD TYPE:
2RPV-W03 LOWER SHELL TO LOWER HEAD CIRC ANALYSIS LOG calibOtion Data Shee No. LSI1- LS8 AcquisItion Log Shee No. W4-l Analysis Log Sheet No. W4-12 W4-PRP-130-169 I 45LD I DN X LMM 3119105 W4-PRP-130-169 2 45LD I UP X LMM 3119105 W4-PRP-130-169 3 45LS / DN X LMM 3M9105 W4-PRP-130-169 4 45LS I UP X LMM 3119105 W4-PRP-130-169 a 45S I DN X LMM 3119105 W4-PRP-130-169 6 45S I UP X LMM 3119/05 W4-PRP-130-169 7 45S I UP X LMM 3M19105 W4-PRP-130-169 8 45LD I DN X LMM 3/19105 W4-PRP-19-190 I 45LD I DN X LMM 3M19105 W4-PRP-19-190 2 45LD I UP X LMM 3M19/05 W4-PRP.169-190 3 45S I DMN X LMM 3/19105 W4-PRP-169-190 4 45LS I UP X LMM 3119105 W4-PRP-16 9-190 5 453 DN X LMM 3M19105 W4-PRP-. 9190 6 45. IUP X LMM 319105 W4-PRP-169-190 7 45S / UP X LMM 3M9105 W4-PRP-169-190 8 45LD0 DN X LMM 3119105 EXAMINER j/p . L a tr
.Aih 6 li X LEVEL .2;? DATE 3 -/If- es-C/ 61
I UNIT INTERVAL: PERIOD: OUTAGE:
PLANT PLANT IUNIT INTERVAL: PERIOD: OUTAGE:
"M CWSN MA. mwYmA a McGUIREI 2 2 3 2EOC16 PROCEDURE: REVISION:
PDI4SI-254 7 W4-PAR-12-47 2RPV-W03 332.70 12A6 KRS IT 3118105 W4-PAR-47-72 2RPV-W03 342.34 47.54 KRS IT 3118105 W4-PAR-72-107 2RPV-W03 332.70 72.46 KRS IT 3118105 W4-PAR-107-132 2RPV-W03 342.34 107.54 KRS IT 3118105 W4-PAR-132-167 2RPV-W03 332.70 132A6 KRS IT 3M8105 W4-PAR-167492 2RPV-W03 342.34 167.54 KRS IT 31181M5 W4-PAR-347-12 2RPV-W03 342.34 347.54 KRS IT 3118105 W4-PAR-192-227 2RPV-W03 332.70 192.46 KRS IT 3118105 W4-PAR-227-252 2RPV-WO3 342.34 227.54 KRS IT 3M8105 W4-PAR-252-287 2RPV-W03 332.70 252A6 KRS IT 3118105 W4.PAR-287-312 2RPV-W03 342.34 287.54 KRS IT 3M8105 W4-PAR-312-347 2RPV-W03 332.70 312A6 KRS IT 3/18105 W4-PRP-190-229 2RPV-W03 190.80 329.20 KRS IT 3118105 W4-PRP-229-250 2RPV-W03 229.00 345.65 KRS IT 3118105 W4-PRP-250-289 2RPV-W03 250.80 329.20 KRS IT 3118/05 W4-PRP-289-310 2RPV-W03 289.00 345.65 KRS IT 3118105 W4-PRP-310-349 2RPV-W03 310.80 329.20 KRS IT 3/18105 W4-PRP-349-10 2RPV-W03 349.00 345.65 KRS IT 3118105 W4-PRP-10-49 2RPV-W03 10.80 329.20 KRS IT 3118105 W4-PRP-49-70 2RPV-W03 49.00 345.65 KRS IT 3/18/05 W4-PRP-70109 2RPV-W03 70.80 329.20 KRS IT 3119105 W4-PRP-109-130 2RPV-W03 109.00 345.65 KRS IT 3119105
I,-
INTER VAU PERIOD: OUTAGE:
PLANT I UNIT PiLANT INTERVAL' PERIOD: OUTAGE:
!JWESoyN
- UIEw EYI SE McGUIRE I 2 3 2EOC16 PROCEDURE: REVISION:
PDIfSI-254 7 DATA ACQUISION LOG Callbratfon Data Sheet No. LSI - LS8 Acquisition Los Sheet No. W41- W4-12 W4-PRP-130-169 I 2RPV-W03 130.80 329.20 KRS IT 3119/05 W4-PRP-169-190 2RPV-W03 169.00 345.65 KRS IT 3119105 I II II I IX II II- ---I I
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution j
CUSTOMER ............. DUJKE POWER SITE . ............McGUIRE UNIT #2 OUTAGE. . ............ 2EOC16 VESSEL TYPE ........... ..WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 Weld and Scan Type = HEAD-VESSEL CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W4-PAR-12-47 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION ELEVATION AZIMUTH (IN) (DEGREES)
TOP LEFT 332.70 12.46 TOP RIGHT .
332.70 47.54 BOTTOM LEFT 348.34 12.46 BOTTOM RIGHT 348.34 47.54 Index Size (in) = 0.50 Number of Indexes Specified = 33 Number of Indexes Completed = 33 Time Date Scan Started 20:41:00.448 03/18/05 Scan Completed 20:47:24.331 03/18/05 Robot Operator Signature PARAGON Operator Signature Comients
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE .............. 2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W4-PAR-47-72 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 79.00 47.54 TOP RIGHT 79.00 72.46 BOTTOM LEFT . 75.00 47.54 BOTTOM RIGHT 75.00 72.46 Index Size (in) = 0.50 Number of Indexes Specified = 14 Number of Indexes Completed = 14 Time Diate Scan Started 21:03:39.645 03/18/05 Scan Completed 21:05:38.743 03/18/05 Robot Operator Signature DATE__-_(8__
-II PARAGON Operator Signature DA TE R/mA. r Comments
WesDyne International Reactor Vessel Ingervice Examination Scan Parameter Execution j
CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 Weld and Scan Type = HEAD-VESSEL CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W4-PAR-72-107 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION ELEVATION AZIMUTH (IN) (DEGREES)
TOP LEFT 332.70 72.46 TOP RIGHT 332.70 107.54 BOTTOM LEFT 348.34 72.46 BOTTOM RIGHT 348.34 107.54 Index Size (in) = 0.50 Number of Indexes Specified = 33 Number of Indexes Completed = 33 Time Date Scan Started 21:10:20.881 03/18/05 Scan Completed 21:16:45.225 03/18/05 Robot Operator Signature DATE 3 -1iJv kUA JAi n w_ h _ -
PARAGON Operator Signature Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER ..............DUKE POWER SITE .............. McGUIRE UNIT #2 OUTAGE .............. 2EOC16 VESSEL TYPE .. ............ WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W4-PAR-107-132 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 79.00 107.54 TOP RIGHT 79.00 132.46 BOTTOM LEFT 75.00 107.54 BOTTOM RIGHT : 75.00 132.46 Index Size (in) = 0.50 Number of Indexes Specified = 14 Number of Indexes Completed = 14 Time Date Scan Started 21:22:31.663 03/18/05 Scan Completed 21:24:30.527 03/18/05 Robot Operator Signature ADATE 3 .- /8 0 PARAGON Operator Signature DATE32z .OT Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 Weld and Scan Type = HEAD-VESSEL CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W4-PAR-132-167 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION ELEVATION AZIMUTH (IN) (DEGREES)
TOP LEFT 332.70 132.46 TOP RIGHT 332.70 167.54 BOTTOM LEFT 348.34 132.46 BOTTOM RIGHT 348.34 167.54
! Index Size (in) = 0.50 Number of Indexes Specified = 33 Number of Indexes Completed = 33 Time Date Scan Started 21:27:37.742 03/18/05 Scan Completed 21:34:02.110 03/18/05 Robot Operator Signature .6, _DATE______
-DATE- 5-LIS -OS PARAGON Operator Signature Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ............. 2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W4-PAR-167-192 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERXDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 79.00 167.54 TOP RIGHT 79.00 192.46 BOTTOM LEFT 75.00 167.54 BOTTOM RIGHT : 75.00 192.46 Index Size (in) = 0.50 Number of Indexes Specified = 14 Number of Indexes Completed = 14 Time Date Stan Started 21:36:42.233 03/18/05 Scan Completed 21:38:40.590 03/18/05 Robot Operator Signature 7 Že k DATE 3-/I- r PARAGON Operator E1i+/-ntULr - A __DAT -/Z&P£f Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER ............. DUKE POWER SITE .............. McGUIRE UNIT #2 OUTAGE .............. 2EOC16 VESSEL TYPE .. ............ WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W4-PAR-347-12 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 79.00 347.54 TOP RIGHT 79.00 372.46 BOTTOM LEFT 75.00 347.54 BOTTOM RIGHT 75.00 372.46 Index Size (in) = 0.50 Number of Indexes Specified = 14 Number of Indexes Completed = 14 Time Date Scan Started 21:44:53.176 03/18/05 Scan Completed 21:46:51.674 03/18/05 Robot Operator Signature -DATE s-4 of PARAGON Operator Signature C _' DA DAT Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER ..............DUKE POWER SITE .............. McGUIRE UNIT #2 OUTAGE .............. 2EOC16 VESSEL TYPE .. ............ WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 Weld and Scan Type = HEAD-VESSEL CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W4-PAR-192-227 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION ELEVATION AZIMUTH (IN) (DEGREES)
TOP LEFT 332.70 192.46 TOP RIGHT 332.70 227.54 BOTTOM LEFT 348.34 192.46 BOTTOM RIGHT 348.34 227.54 Index Size (in) = 0.50 Number of Indexes Specified = 33 Number of Indexes Completed = 33 Time Date Scan Started 21:53:11.236 03/18/05 Scan Completed 21:59:35.472 03/18/05 Robot Operator Signature DATE 5-~i0-PARAGON Operator Signature Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W4-PAR-227-252 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 79.00 227.54 TOP RIGHT 79.00 252.46 BOTTOM LEFT 75.00 227.54 BOTTOM RIGHT 75.00 252.46 Index Size (in) = 0.50 Number of Indexes Specified = 14 Number of Indexes Completed = 14 Time Date Scan Started 22:02:05.212 03/18/05 Scan Completed 22:04:04.351 03/18/05 Robot Operator Signature 73JA4TDATE .-l s-PARAGON Operator Signature 4 ^ DATE .3 LRepos Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 Weld and Scan Type = HEAD-VESSEL CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W4-PAR-252-287 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION ELEVATION AZIMUTH (IN) (DEGREES)
TOP LEFT 332.70 252.46 TOP RIGHT 332.70 287.54 BOTTOM LEFT 348.34 252.46 BOTTOM RIGHT 348.34 287.54 Index Size (in) = 0.50 Number of Indexes Specified = 33 Number of Indexes Completed = 33 Time Date Scan Started 22:07:06.199 03/18/05 Scan Completed 22:13:30.918 03/18/05 Robot Operator Signature A -a DATE-0-.
PARAGON Operator Signature ~DATE.3-/n Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W4-PAR-287-312 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 79.00 287.54 TOP RIGHT 79.00 312.46 BOTTOM LEFT 75.00 287.54 BOTTOM RIGHT : 75.00 312.46 Index Size (in) = 0.50 Number of Indexes Specified = 14 Number of Indexes Completed = 14 Time Date Scan Started 22:15:59.624 03/18/05 Scan Completed 22:17:58.690 03/18/05 Robot Operator Signature aDATE-L-it -os-7*wL PARAGON Operator Signature vrs 1 c<< J t s as Comments k__
WesDyne International Reactor Vessel Inservicip Examination Scan Parameter Execution CUSTOMER ..............DUKE POWER SITE .............. McGUIRE UNIT #2 OUTAGE .............. 2EOC16 VESSEL TYPE .. ............ WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 I Weld and Scan Type = HEAD-VESSEL CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W4-PAR-312-347 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION ELEVATION AZIMUTH (IN) (DEGREES)
TOP LEFT 332.70 312.46 TOP RIGHT 332.70 347.54 BOTTOM LEFT 348.34 312.46 BOTTOM RIGHT 348.34 347.54
) Index Size (in)
Number of Indexes Specified
=
=
0.50 33 Number of Indexes Completed = 33 Time Date Scan Started 22:21:26.945 03/18/05 Scan Completed 22:27:55.765 03/18/05 Robot Operator Signature ..'A DATELLS§ PARAGON Operator Signature 7L DATE Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER ..............DUKE POWER SITE .............. McGUIRE UNIT #2 OUTAGE .............. 2EOC16 VESSEL TYPE .. ............ WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 Weld and Scan Type = HEAD-VESSEL CIRCUMFERENTIAL PERPENDICUAR SCA Scan Data File Name = W4-PRP-190-229 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH ELEVATION (DEGREES) (IN)
TOP LEFT 190.80 329.20 TOP RIGHT 229.00 329.20 BOTTOM LEFT : 190.80 347.59 BOTTOM RIGHT : 229.00 347.59 1 Index Size (in) = -0.50 Number of Indexes Specified = 117 Number of Indexes Completed = 117 Time Date Scan Started 22:37:46.473 03/18/05 Scan Completed 22:48:54.355 03/18/05 Robot Operator Signature PARAGON Operator Signature Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUT A GE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIPICATION - 2RPV-W03 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W4-PRP-229-250 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 229.00 76.80 TOP RIGHT 250.80 76.80 BOTTOM LEFT 229.00 75.50 BOTTOM RIGHT 250.80 75.50 Index Size (in) = 0.50 Number of Indexes Specified = 69 Number of Indexes Completed = 69 Time Date Scan Started 22:52:51.111 03/18/05 Scan Completed 22:55:59.791 03/18/05 Robot Operator Signature t / ,4 DATE §-'ivr PARAGON Operator Signature 741AAf2 E 4 'DATE 3-/8~-d4 Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 Weld and Scan Type = HEAD-VESSEL CIRCUMFERENTIAL PERPENDICUAR SCA Scan Data File Name = W4-PRP-250-289 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH ELEVATION (DEGREES) (IN)
TOP LEFT 250.80 329.20 TOP RIGHT 289.00 329.20 BOTTOM LEFT 250.80 347.59 BOTTOM RIGHT 289.00 347.59 Index Size (in) = 0.50 Number of Indexes Specified = 117 Number of Indexes Completed = 117 Time Date Scan Started 22:58:36.606 03/18/05 Scan Completed 23:09:28.188 03/18/05 Robot Operator Signature { at X DATE S -/i -6' PARAGON Operator Signature -
r FItr- 4 . A_
IDATE3~ r/,
tt t('
Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution I
CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W4-PRP-289-310 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 289.00 76.80 TOP RIGHT 310.80 76.80 BOTTOM LEFT 289.00 75.50 BOTTOM RIGHT : 310.80 75.50
) Index Size (in)
Number of Indexes Specified
=
=
0.50 69 Number of Indexes Completed = 69 Time Date Scan Started 23:12:54.527 03/18/05 Scan Completed 23:15:48.266 03/18/05 Robot Operator Signature M4 ~ & zATE d-( J PARAGON Operator Signature 4 / J A DATE 3 Y- VSO-Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............. .WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 Weld and Scan Type = HEAD-VESSEL CIRCUMFERENTIAL PERPENDICUAR SCA Scan Data File Name = W4-PRP-310-349 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH ELEVATION (DEGREES) (IN)
TOP LEFT 310.80 329.20 TOP RIGHT 349.00 329.20 BOTTOM LEFT 310.80 347.59 BOTTOM RIGHT 349.00 347.59 Index Size (in) = 0.50 Number of Indexes Specified = 117 Number of Indexes Completed = 117 Time Date Scan Started 23:19:06.147 03/18/05 Scan Completed 23:30:59.879 03/18/05 Robot Operator Signature J k DATE 3-/pg-PARAGON Operator Signature A'nL DATE rELI&f?
J4,,
Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2PPV-W03 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W4-PRP-349-10 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 349.00 76.80 TOP RIGHT 370.80 76.80 BOTTOM LEFT 349.00 75.50 BOTTOM RIGHT 370.80 75.50 Index Size (in) = 0.50 Number of Indexes Specified = 69 Number of Indexes Completed = 69 Time Date Scan Started 23:33:41.326 03/18/05 Scan Completed 23:36:39.740 03/18/05 Robot Operator Signature PARAGON Operator Signature X" .ate: DATE_____-/dr Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 Weld and Scan Type = HEAD-VESSEL CIRCUMFERENTIAL PERPENDICUAR SCA Scan Data File Name = W4-PRP-10-49 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH ELEVATION (DEGREES) (IN)
TOP LEFT 10.80 329.20 TOP RIGHT 49.00 329.20 BOTTOM LEFT 10.80 347.59 BOTTOM RIGHT 49.00 347.59 Index Size (in) = 0.50 Number of Indexes Specified = 117 Number of Indexes Completed = 117 Time Date Scan Started 23:38:28.330 03/18/05 Scan Completed 23:49:57.855 03/18/05 Robot Operator Signature .,.! DATE 7 -d -O6 PARAGON Operator Signature DATE
@vX,/ Ar Comments I
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W4-PRP-49-70 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 49.00 76.80 TOP RIGHT : 70.80 76.80 BOTTOM LEFT : 49.00 75.50 BOTTOM RIGHT : 70.80 75.50 Index Size (in) = 0.50 Number of Indexes Specified = 69 Number of Indexes Completed = 69 Time Date Scan Started 23:52:13.255 03/18/05 Scan Completed 23:55:12.276 03/18/05 Robot Operator Signature DATE 3- -S-PARAGON Operator Signature 1X v DATE cs 3,S- -
Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 Weld and Scan Type = HEAD-VESSEL CIRCUMFERENTIAL PERPENDICUAR SCA Scan Data File Name = W4-PRP-70-109 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH ELEVATION (DEGREES) (IN)
TOP LEFT 70.80 329.20 TOP RIGHT 109.00 329.20 BOTTOM LEFT 70.80 347.59 BOTTOM RIGHT 109.00 347.59 Index Size (in) = 0.50 Number of Indexes Specified = 117 Number of Indexes Completed = 117 Time Date Scan Started 23:58:02.673 03/18/05 Scan Completed 00:08:53.173 03/19/05 Robot Operator Signature ADATE 3 q -0o PARAGON Operator Signature Comments
Wesbine International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER ................. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W4-PRP-109-130 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 109.00 76.80 TOP RIGHT 130.80 76.80 BOTTOM LEFT 109.00 75.50 BOTTOM RIGHT 130.80 75.50 Index Size (in) = 0.50 Number of Indexes Specified = 69 Number of Indexes Completed = 69 Time Date Scan Started 00:11:26.413 03/19/05 Scan Completed 00:14:26.210 03/19/05 Robot Operator Signature SDATE 1-(S° PARAGON Operator Signature i4; &DATE Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 Weld and Scan Type = HEAD-VESSEL CIRCUMFERENTIAL PERPENDICUAR SCA Scan Data File Name = W4-PRP-130-169 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH ELEVATION (DEGREES) (IN)
TOP LEFT 130.80 329.20 TOP RIGHT 169.00 329.20 BOTTOM LEFT 130.80 347.59 BOTTOM RIGHT : 169.00 347.59 Index Size (in) = 0.50 Number of Indexes Specified = 117 Number of Indexes Completed = 117 Time Date Scan Started 00:16:32.700 03/19/05 Scan Completed 00:27:23.199 03/19/05 Robot Operator Signature PARAGON Operator Signature Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W03 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W4-PRP-169-190 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 169.00 76.80 TOP RIGHT 190.80 76.80 BOTTOM LEFT 169.00 75.50 BOTTOM RIGHT 190.80 75.50 Index Size (in) = 0.50 Number of Indexes Specified = 69 Number of Indexes Completed = 69 Time Date Scan Started 00:29:27.875 03/19/05 Scan Completed 00:32:26.587 03/19/05 Robot Operator Signature PARAGON Operator Signature Comments
REQUEST RELIEF 05-MN-003 ATTACHMENT 2 PAGES 1-81
A AAci~KERN 2-WesDyne International Reactor Vessel Weld Results Summary McGUIRE UNIT 2 WELD NO. 2RPV-W01 DESCRIPTION Lower Head to Bottom (B01.021.002) Head Circ LIMITATIONS NO D YES i COVERAGE = 87.19%
Limitation due to proximity of Peripheral BMI Tubes.
RESULTS NO. OF INDICATIONS 9 STATUS CODE ALLOWABLE EXAM DOCUMENTATION INDICATION DOCUMENTATION WANALYSIS LOG W1 ASSESSMENT SHEET W ACQUISITION LOG WI PARAGON HARD COPY RX SCAN PRINTOUT K] OTHER (specify)
[X] COVERAGE BREAKDOWN WESDYNE ANALYST <: 1
McGuire Unit 2 DIRECTION / ORIENTATION RPV COVERAGE ESTIMATE BREAKDOWNS PARALLEL SCANS CCW/CW PERP. SCANS UP/DN WELD LOWER SHELL TO BOTTOM HEAD WELD NO. 2RPV-W01 DESCRIPTION CIRC WELD BEAM ANGLES BEAM 450 L Dual 450 L Single 450 Shear DIRECTION WELD VOLUME WELD VOLUME WELD VOLUME WELD VOLUME WELD VOLUME Ccw 86.6 87.5 100 93 100 93 Cw 86.6 87.5 100 93 100 93 UP 85.97 81.65 81.29 78.43 78.77 79.07 DOWN 85.97 77.93 81.29 80.95 78.77 82.37 Combined Average = 87.19% Limitation due to proximity of peripheral BMI Tubes.
ANALYST___ _
PLANT I UNIT McGUIRE 12 OPTICAL DISK #
I!.. ynn PROCEDURE: PDI4ISI-254 REVISION: 7 WELD # WELD TYPE:
2RPV-W0OI LOWER HEAD TO BOTTOM HEAD CIRC ANALYSIS LOG Calfbratlon Data Sheet No. LSI - LS8 Acquisition Log Sheet No. W51, W5-2, W5-3 Analysis Log Sheet No. W5-1
_4 W5-PRP-188-175 1 l_45L I DN X LMM 3M9105 WW-PRP-168-175 2 45L / UP X LMM 311915 W5-PRP-168-175 3 45L I DN X LMM 3M19M5 W5-PRP-168-175 4 45L/ UP X LMM 3119105 W5-PRP-168-175 5 45S/ DN X LMM 319105 W5-PRP-168175 6 45S! UP X LMM 319105 W5-PRP-168-15 7 45S/ UP X LMM 3M1915 W5-PRP-168-175 8 45L/ DN X LMM 311915 W5-PRP-145-168 I 45L ION X LMM 311915 WS-PRP-145-168 2 45L/ UP X LMM 3M9105 W5-PRP-145-168 3 45 I/DN X LMM 3/1915 W5-PRP-145-168 4 45L I UP X LMM 311915 W5-PRP-145-188 5 45S/ DN X LMM 3119105 W5-PRP-145-168 6 45S/UP X LMM 31191S WS-PRP-145-188 7 45SI UP X LMM 3119105 W5-PRP-145168 8 45L! ON X LMM 3119105 EXAMINER LEVEL DATE _S-I I -05 tA tl 6' cr
PLANT I UNIT McGUIRE 12 OPTICAL DISK N WI PROCEDURE: PD14S1-254 REVISION: 7 WELD # WELD TYPE:
2RPV-WO1 LOWER HEAD TO BOTTOM HEAD CIRC ANALYSIS LOG Callbration Data Sheet No. LS1.-LS8 Acquisition Log Sheet No. W5-1, WS-2, WS-3 Analysis Log Sheet No. WS-2 WS-PRP-135-145 1 45L I ON X MISNAMED - WS-PRP-35-14 Is actual name. LMM 3119105 WS-PRP-135M145 2 45L I UP X LMM 3119105 WS-PRP-135-145 3 45L I ON X LMM 3M9/05 W5SPRP-135-145 4 45L I UP X LMM 3119105 WSPRP-135-145 5 45S O ON X LMM 3119105 WSPRP-135-145 6 45 IUP X LMM 3119105 WS-PRP413545 7 45_/UP X 1MM 3119m0 WS-PRP-135-145 8 451 I DN X LMM 3119105 WSPRP-127-135 I 45L I DN X LMM 3M19105 W5S12111-127-135 2 45L I UP X LMM 3119105 WS-PRP-127-135 3 45L ON X LMM 3119105 W5 PRP-127-135 4 45L I UP X LMM 3119105 W&PRP-127-135 5 45S I ON X LMM 3119105 WSPRP-127-135 6 45S 1 UP X LMM 3119105 WS-PRP-127-135 7 453 1 UP X LMM 3119105 W5-PRP-127-135 8 45L / ON X LMM 3119105
- 4 'I ________ I 4 4 I.? I.
a .i .i - I. -. 6.
a i - I. A I.
EXAMINER 4 -a~mgmi LEVEL 222 DATE __e U CJ
PLANT I UNIT MCGUIRE /2 OPTICAL DISK #
N W KD y EPROCEDURE: PD14SI-254 REVISION: 7 WELD 1 WELD TYPE:
2RPV-WQ1 LOWER HEAD TO BOTTOM HEAD CIRC ANALYSIS LOG Calibration Date Sheet No. LSI - LS8 Acquisition Log Sheet No. WS-I, WS-2, W5-3 Analysis Log Sheet No. W5-3 WS&PAR-236-287. 45L I CW X LMM 3119105 WS-PAR-236-287 2 45L I CCW X LMM 3119105 W-PAR-23-287 3 45LI CW X LMM 3119/05 W6-PAR-236-287 4 45L I CCW X LMM 3119/05 W8-PAR-236-287 5 45L I CW X LMM 3M19/05 WS-PAR-236-287 5 45S I CCW X LMM 3/19/05 WS-PAR-236-287 7 46S ICCW X LMM 3119105 WS-PAR-236-287 8 45L I CW X LMM 3/19/05 W5-PRP-20427 1 45L I ON X LMM 3/19/05 WS-PRP-120-127 2 46L1/ UP X LMM 3119/05 W5-PRP-120-127 3 45L I ON X LMM 3119/05 W5-PRP-120-127 4 45L I UP X LMM 3/19/05 WS-PRP-1204127 5 453/ DN X LMM 3/19/05 WS-PRP-120-127 6 456/UP X LMM 3/19105 WS-PRP-120-127 7 45S / UP X LMM 3/19/05 WS-PRP-120-127 8 45L / DN X LMM 3/19/05
-J -- ______________________________________.
EXAMINER £sAAAkA .'*,AhAflJA LEVEL r DATE 3- l -aDS (I 61
PLANT I UNIT MeGUWRE 12 OPTICAL DISK #
N PROCEDURE: PD1431-254 REVISION: 7 WELD WELD TYPE:
2RPV-WOI LOWER HEAD TO BOTTOM HEAD C!RC ANALYSIS LOG Calibuatlon Dat Sheet No. LSI - 198 Acquiston Log Sheet No. W5-1,W5W54
______ _____Analysis Log Sheet No. W&4 WS-PRP-109-120 I 45LIDN X indctton#I FOD 3119105 WS-PRP-109-120 2 45L/ UP X Idftaion #I1Code Aloamble FOD 3119105 W5-PRP-109-120 3 45L ON X FOD 3M9105 W5-PRP-109-120 4 45L UP X FOD 319105 WS-PRP-109-120 5 45SI ON X FGD 319105 W5-PRP-109-120 6 45S1 UP X FOD 3119X5 W5-PRP-109-120 7 45Sf UP X FOD 319105 W5-PRP-109-120 45L ON _ FGD 3119105 E.M.E _EE DAT EXAMINER LEVEL DATE 0 11/1%k
PLANT I UNIT Mc0UIRE /2 OPTICAL DISK #
1 W ESDyI1E its 001ATI*Uh.
PROCEDURE: PD14S1-254 REVISION: 7 WELD #WELD TYPE:
2RPV-WOI LOWER HEAD TO BOTTOM HEAD CIRC ANALYSIS LOG Clbatlon Data Sheet No. LS1 - LSB Acquisition Log Sheet No. WS-I, WS-2, W&3
__ ___ __ __ __Analysis Log Sheet No. W5-5 WPRP-62 71 1 Il 4SL O X DN 5 FOD 3M91 W5-PRP-62-71 2 45L I UP X FGD 3119105 WS-PRP42-71 3 45L I DN X FOD 3M9105 WS-PRP462-71 4 45L I UP X FGD 3M9105 WS-PRP462-71 5 45S / ON X FOD 3119105 W5-PRP-42-71 6 45S / UP X FGD 3M9105 WS-PRP-62-71 7 45S/ UP X FOD 3119105 WS-PRP-62-71 8 45L I ON _ FOD 3119105 W5-PRP-44-62 1 45L / ON X FOD 3119/05 W5-PRP-4462 2 45L I UP X FGD 3119105 W5-PRP-4462 3 45L I ON X FOD 3M9105 W5-PRP-4462 4 45L / UP X FGD 3119105 WS-PRP4442 5 453/ DN X FGD 3119/05 WS-PRP462 6 45S I UP X FGD 3119105 W5-PRP462 7 45S / UP X FGD 3/19105 W5-PRP-4462 8 45L I ON FGD 3119/05
_ =- -
EXAMINER LEVEL DATE I f
PLANT I UNIT McGUIRE /2 OPTiCAL DISK #
IM Dl PROCEDURE: PDI4SI-254 REVISION: 7 WELD # WELD TYPE:
2RPV-WOI LOWER HEAD TO BOTtOM HEAD CIRC ANALYSIS LOG Calibration Data Sheet No. LS1 - LS8 Acquisition Log Sheet No. WS-1, W5-2, W53 Analysis Log Sheet No. W54 --
W5-PRP-35-44 1 45L / DN % FGD 3119105 WS-PRP-35-44 2451.! UP X .lFGD 3119/05 W5S-PRP-35-44 W5-PRP-35.44 63 45LSI 45S.1 UP DN XFGD X .___ FQD 3119105 3/19105 WS-PRP-35-44 I 45L I ON X FGD 3M9105 W5-PRP-35-44 7 45L / UP X FOD 3M9105 W5-PRP-35-44 8 45L /IDN U FOD 3/19105 WS-PRP-235 1 451 I DN X FOD 3119105 W5-PRP-3435 2 451 I UP X FGD 3M9105 W5-PRP-28-35 3 45L I PD X FGD 3119/05 WS-PRP-28-35 4 46LI UP X FOD 3/19/05 W5-PRP-28435 -45LIDN X l FOD 3119105 WS-PRP-28435 6 45L I UP X FGD 3/19105 W5-PRP-2835 7 45S /UP X FGD 3/19105 W5-PRP-28-35 8 45S/ DN _ _ FOD 3/19105 EXAMiNER , -
LEVEL DATE as h
PLANT I UN1T McGUIRE 12 OPTICAL DISK #
N wD PROCEDURE: PD14SI-254 REVISION: 7 WELD # WELD TYPE:
2RPV-W0I LOWER HEAD TO BOTTOM HEAD CIRC ANALYSIS LOG Calibration Data Sheet No. LSI - LS8 Acquisition Log Shee No. W5-I, WS-2, W5-
__ __ _ __ __ _ _ __ __ _Analysis Log Sheet No. W 5-7 WS-PRP-18-28 I 451.I ON X FD 319105 W5-PRP-18-28 2 45L I UP X FOD 3119105 WS-PRP-18-28 3 45L I DN X FOD 3119105 WS-PRP-18-28 4 45L I UP X FOD 3119105 W5-PRP-18-28 5 45S I ON X FOD 3119105 WS-PRP-18-28 6 451IUP X FGD 3119105 W5-PRP-18-28 7 45S IUP X FGD 3119/05 W5-PRP-18-28 8 4531 ON . _ FGD 3119105 W5-PRP-329-18 45L I DN X IndiatIon # 2 FOD 3119105 WS-PRP-329-18 2 45L I UP X IndWcation # 2 Code Allowable FGD 3119105 WS-PRP-329-18 3 45L I DN X Indhation # 4 Code Allowable FGD 3119105 W5-PRP-329-18 4 45L I UP X IndIcation # 4 FOD 3119105 WS-PRP-329-18 5 45S I ON X Indicaton # 4 FOD 3119105 W5-PRP-329-18 6 45S IUP X Indlcaton # 4 FOD 3119105 W5-PRP-329-18 7 45S IUP X FOD 3M19105 WS-PRP-329-18 8 45L I DN _ _ FGD 3119105
==-_.
EXAMINER LEVEL _ , j77
_ DATE
PLANT I UNIT MeGUIRE 12 OPTICAL DISK#
PM WSAFE=I MPRONAT*S ONAL PROCEDURE: PDI4SI-254RESONT WELD# WELD TYPE:
2RPV-WOI LOWER HEAD TO BOTTOM HEAD CIRC ANALYSIS LOG Calibration Data Sheet No. S1.1- LS8 Acquisition Log Sheet No. W5-1, W5-2, W5-3
._ Analysis Log Sheet No, W8 Wo-PRP-322-329 1 45L/ DN X FGD 3119105 W5-PRP-322-329 2 45LIUP X FOD 3119105 W5-PRP-322-329 3 451./DN X FGD 31191S WS-PRP-322-329 4 45L I UP X FGD 31191S W5-PRP-322-329 5 45S3IDN X FOD 3119105 W5-PRP-322-329 6 453 IUP X FOD 311915 W5-PRP-322-329 7 45S/UP X FOD 311915 W5-PRP-22-329 8 45L/IDN _ _ FOD 3119105 W5-PRP-314-322 1 45L/DN X ftdkcaton #5 Code Aflwable FOD 3119105 W5PRP-314-322 2 45L IUP X FOD 3119105 W5-PRP-314-322 3 45L ION X FOD 3119105 W5-PRP-314-322 4 45LI UP X FOD 3M9105 W5-PRP-314-322 5 45SIDN X FGD 3/19/05 WS-PRP-314-322 6 45S/ UP X FOD 3119105 W5-PRP-314-322 7 45S I UP X FOD 3119105 W5-PRP-314-322 8 45L/I ON X FOD 3119105 EXAMINER - I- v_
LEVEL -r - - DATE _ 2/J /o,
PLANT I UNIT MoGUIRE 12 OPTICAL DISK#
ynES~IE PROCEDURE: PDI-4Sl-254 REVISION: 7 WELD# WELD TYPE:
2RPV-WOI LOWER HEAD TO BOTTOM HEAD CIRC ANALYSIS LOG Calibaton Data Sheet No. _S1 - LS8 Acquisition Log Sheet No. W5_1, W5-2, W5-3
_______________Analysis Log Sheet No. WS$9 W5 PRP-305-314 1 45L/I1DN X FOD 3M19/05 W5"PRP-305-314 2 45L/UP X FOD 3M9105 WSPRP-3054314 3 451.1ON X FOD 3119105 W5-PRP405-314 4 45L/UP X FOD 3119105 W5PRP-305-314 5 45SDON X FGD 3119105 W5-PRP-305-314 6 45SI UP X FOD 3119105 W5 PRP-305-314 7 45S/ UP X FOD 3M9/05 WS-PRP-305-314 8 45L I DN FOD 3119105 WS"PRP-298-305 1 45.I ON X Indication #6 Code Allowable FGD 3119105 W5-PRP-2984305 2 451.!UP X Indication =6 FOD 311910S5 W5-PRP-298305 3 45L. DN X FOD 3119105 WS-PRP-298-305 4 45L.I UP X FGD 3119105 WS-PRP-298W05 5 455/DN X FGD 3119105 WS-PRP-298-305 6 45S f UP X FOD 3/19105 W5-PRP-298-305 7 45S! UP X FOD 3119105 W5-PRP-298-305 8 45L I DN FOD 3119/05 EXAMNER EVELDATEas h?_.
EXAMINER LEVEL .
DATE .n3 /h iO
PLANT I UNIT MCGUIRE 12 OPTICAL DISK #
.*,E w .VES M*Y 3M&
yna PROCEDURE: PD14SI-254 REVISION:
7 WELD # WELD TYPE:
2RPV.WOI LOWER HEAD TO BOTTOM HEAD CIRC ANALYSIS LOG Calibrtion Daft Sheet No. LSI - LS8 Acquisition Log Shee No. WS-1, WS-2, W54 Analysis Log Sheet No. W5-1o
~- -
W5-PRP-288-298 I 45LIDN X FGD 3119105 W5&PRP-288-298 2 45LIUP X FOD 3/19105 W5-PRP-288-298 3 45LI ON X FGD 3M9105 W5-PRP-288-298 4 45L I UP X FGD 3119105 W5-PRP-288-298 5 45SI ON X FGD 3119105 W5-PRP-288-298 6 45SI UP X FPD 3M9105 WS-PRP-288-298 7 45SI UP X FOD 3M9105 W5-PRP-288298 8 45L I DN _ FGD 3/19105 W5-PRP-281-288 I 45L I DN X Indleaton # 7, 8 Code Alowable FGD 3119105 W5-PRP-281288 2 45LI UP X Indicatlon #7,8 Code Allowable FOD 3119105 WS-PRP-281-288 3 45L ION X FGD 3M19/05 W5"PRP-281-288 4 45LI UP X FOD 3119105 W5-PRP-281-288 5 46SI ON X FOD 3119105 W5-PRP-281-288 6 45Sf UP X FGD 3/19/05 W5-PRP-281-288 7 45S/ UP X FGD 3119105 W5-PRP-281-288 8 45L I DN _ _ FGD 3119/05 EXAMINER 7-7A-V elp~~ LEVEL -
DATE I I
PLANT I UNIT McOUIRE 12 OPTICAL DISK #
N WESD ynE PROCEDURE: PDIISI-254 REVISION: 7 WELD # WELD TYPE:
2TPV-W01 LOWER HEAD TO BOTTOM HEAD CIRC ANALYSIS LOG Calibration Data Sheet No. LS1 - L.8 Acquisition Log Sheet No. WS-I, WS-2, W5-3 Analysis Log Sheet No. WS-11 W6 PRP-274-281 I 45L I DN X Indfwlfn # 9 Code Alftowabte FGD 3/19t05 W5"PRP-274-281 2 45L I UP X Indatkon # 9 FOD 3119105 W5 PRP-274-281 3 45L I ON X FOD 3119105 W5-PRP-274-281 4 45L I UP X FOD 3119106 WS-PRP-274-81 5 45S/ DN X FOD 3119105 W5-PRP-274-281 6 45S IUP X FOD 3119/05 W5"PRP-274-281 7 45S I UP X FOD 3119105 WS PRP-274-281 8 45L I ON _ _ FGD 3119/05 W5-PRP-235-274 1 46L I DN X FOD 3120/05 WW-PRP-235-274 2 45L I UP X FOD 312010/
W5-PRP-235-274 3 45L I DN X FGOD 3120/05 WC-PRP-235-274 4 45L / UP X FGD 3/20/05 W5-PRP-235-274 5 45S I DN X FGD 3120105 W5-PRP-235-274 6 45S IUP X FGD 3/20105 WS-PRP-235-274 7 45S / UP X FOD 3/20/05 W5-PRP-235-274 8 45L I ON _ _ FOD 3120105 E..IE =77DT LEE ~ kh EXAMINER LEVIEL 77 DATE o/oo
PLANT I UNIT McGUIRE 12 OPTICAL DISK #
r WE l-VW WROD"m PROCEDURE: PDJ4SI-254 REVISION: 7 WELD # WELD TYPE:
2RPV-WOI LOWER HEAD TO BOTTOM HEAD CIRC ANALYSIS LOG Callbratlon Data Sheet No. LS1 - LS8 Acqulsition Log Sheet No. W5-1, WS-2, W5-3
. Analysis Log Sheet No. WS-12 t Si WS-PRP-225-235 I 45L I DN X FOD 3120105 W5-PRP-225-235 2 45L / UP X FGD 3120105 WS-PRP-225-235 3 45L I DN X FGD 3/20JD5 W5.PRP-225-235 4 45L / UP X FGD 3120105 W5-PRP-225-235 5 45S /DN X FGD 3120105 W5-PRP-225-235 6 45Sf UP X FGD 3120105 W5-PRP-225-235 7 45S I UP X FOD 3120105 W5-PRP-225-235 8 45L/ DN _ _ FGD 3120105 W5-PRP-199-225 I 45L/ DN X FGD 3120105 W5-PRP-199.225 2 45L/ UP X FGD 3120105 WS-PRP-199-225 3 45L/ DN X FGD 310105 WS-PRP-199225 4 45L/UP X FGD 3120105 W5-PRP-199-225 5 45S/ DN X FGD 3/2015 W5-PRP-199-225 6 45S I UP X FGD 3120105 W5-PRP4199-225 7 45SIUP X FOD 3/20105 W5-PRP-199-225 8 45L /DN _ FOD 3/20/05 E.MIE L.. ~ 2 .DT EXAMINER LEVEL DATE as /Zzo /r
PLANT I UNiT MCGUIRE 12 OPlICAL DISK #
-mtg"j I
PROCEDURE: PDI-ISI-254 REVISION: 7 WELD # WELD TYPE:
2RPV-WOI LOWER HEAD TO BOTTOM HEAD CIRC ANALYSIS LOG CalIbmrton Data Sheet No. LSI - LSB AcquIsItIon Log Sheet No. WS-1, W5-2, W5-3 Answfvds Lno Aiwwit No. W5-13 W5-PRP-191-199 I 45L I DN X FUD 3120/05 WS-PRP-191-199 2 45L I UP X FGD 3120/05 WS-PRP-191-199 3 45L/DN X FGD 3120105 W5-PRP-191-199 4 45L I UP X FGD 3120105 WS-PRP-191-199 5 45S / DN X FOD 312;005 W5-PRP-191-199 6 45S I UP X FGD 3120105 WS-PRP-191-199 7 45S I UP X FGD 3/20105 WS-PRP-191-199 8 45L I DN _ _ FGD 3120105 W5-PAR-180-224 I 45L I CW X CHL 3119105 WS-PAR.180-224 2 45L I CCW X CHL 3/19105 WSPAR4180-224 3 45L I CW X CHL 31910S W5.PAR-180"224 4 45L I CCW X CHL 3/1915 WS-PAR-180-224 5 45S I CW X CHL 3/19105 W5 PAR-180-224 6 45S I CCW X CHL 3/19105 WS-PAR-180-224 7 45S / CCW X CHL 3/19105 WS-PAR-180-224 8 45L I CW X CHL 3/1910S EXAMINER Ch4M //L4i t-,e LEVEL Z7 DATE _ _ _ _ _ _ _
PLANT I UNIT McoGUIRE 12 OPTICAL DISK #
rW muIVs.
ONe SD nE A* SAL PROCEDURE: PDi-254 REVION: 7 WELD # WELD TYPE:
2RPV-WOI LOWER HEAD TO BOTTOM HEAD CIRC ANALYSIS LOG Calibration Data Sheet No. LS1 - LS8 Acquisition Log Sheet No. W561, W5-2, W5-3 Analysis Log Sheet No. WS-14
_ __ 1 -r W5&PAR-316-17 W__ PAR_31_47 I
2_4_LI I45L I CW CC_
X X
CHL C
3119105 3M9105__.
W5-PAR-316-17 2 45L I CCW X CHL 3119105 W5-PAR-316-17 3 45L I CW X CHL 3119/05 W5-PAR-316-17 4 45L ICCW X CHL 3M9105 WS-PAR-316-17 5 45S I CW X CHL 3119105 W5-PAR-316-17 6 45! CCW X CHL 3119105 WS-PAR-316-17 7 45 ICCW X CHL 3119/05 W5-PAR4316817 8 45L I CW X CHL 3119105 WS-PAR.146-180 2 45L I CW X CHL 3119105 W5-PAR-146-180 2 46L ICCW X CHL 3119105 W5-PAR-146-180 3 45L CW X CHL 3119105 W5-PAR-146-180 4 45L ICCW X .CHL 3/19105 WS-PAR-146-180 5 45S3 CW X CHL 3119105 W5-PAR-146-180 6 45S I CCW X CHL 3119105 WS-PAR-146-180 7 45S I CCW X CHL 3M19105 W5-PAR-146-180 8 46L5I CW X CHL 3119105 I I I.
4 4 4 4 4 4 4 4 4 4
____________________________ i .a fee
&z 5 LVEL DATE 4
03-Ig -o EXAMINER EXAMINlER (Aaij 1^Gkm Hun flux L-ee LEVEL DATE 03 -lq t
-"-- V , -- -
PLANT I UNIT McOUIRE 12 OPTICAL DISK
- N W D E PROCEDURE: PDH4SI-254 REVISION: 7 WELD # WELD TYPE:
2RPV-WOI LOWER HEAD TO BOTTOM HEAD CfRC ANALYSIS LOG Calfbratlon Dat Shee No. L91 -1.98 Acquisiton Log She No. WS-I, W5-2, WS.3 Analysis Log Sheet No. W-15
~ I ~ -O- N WS-PRP-175-191 I 45L I DN X CHL 3/19105 WSPRP-175-191 2 46L I UP X CHL 3119105 WS-PRP-175-191 3 45L I DN X CHL 3119105 W5-PRP-175-191 4 45L I UP X CHL 3M19105 WS-PRP-175-191 5 45S I DN X CHL 3119105 WS-PRP-175-191 6 45S/ UP X CHL 3119105 WS-PRP-175-191 7 45S I UP X CHL 3119105 WS-PRP-175-191 8 45I DN X CHL 3M19105 WS-PAR-46-61 I 45L I CW X LMM 3119105 W5-PAR-4861 2 45L I CCW X LMM 3M9105 W5-PAR-46-61 3 45L I CW X LMM 3119105 WS-PAR46461 4 45L I CCW X LMM 3M19105 W5-PAR-4616 5 45S I CW X LMM 3M9105 W5-PAR-46461 6 45S I CCW X LMM 3119105 W5-PAR-4661 7 45S I CCW X LMM 3119105 WS-PAR-46461 8 45L / CW X LMM 3M19105 EXAMINER -
IL)1~7~f7Me.64am~ ItUN V
Iee LEVEL -
T / L e _
DATE 4-rq V
PLANT / UNIT McGUIRE /2 OPTICAL DISK #
N g
W IA..TIO..
D IE
£AL PROCEDURE: PD14S1-254 REVISION: 7 WELD # WELD TYPE:
2RPV-WOI LOWER HEAD TO BOTTOM HEAD CIRC ANALYSIS LOG Calibration Data Sheet No. LS1 - LS8 Acquisition Log Sheet No. W5-1, WS-2, W5&3
. Analysis Log Sheet No. W5-16 W5-PAR-72-134 I 45L I CW X SAS 3119105 WS-PAR-72-134 2 45L I CCW X SAS 3119/05 WS-PAR-72-134 3 45L / CW X SAS 3119/05 WW-PAR-72-134 4 45L / CCW X SAS 3119/05 W5-PAR-72-134 5 45S / CW X SAS 3119/05 W5-PAR-72-134 6 45S / CCW X tndlcation # 3 Code Anowable SAS 3/19105 WS-PAR-72-134 7 45S / CCW X SAS 3/19/05 W5-PAR-72-134 8 45L/ CW X SAS 3/19/05 E.ME LEE DAT EXAMiNER LEVEL DATE
PLANT I UNIT McGUIRE 12 OPTICAL DISK 1 PROCEDURE: PDI-4S1-254 REVISION: 7 "I... *.*. m*.
WELD # WELD TYPE:
2RPV-WO1 LOWER HEAD TO BOTTOM HEAD CIRC ANALYSIS LOG Caibration Data Shee No. LSI - LS8 Acqulsftlon Log Sheet No. W5-1, WS-2, W5-3 Analysis Log Sheet No. W5-17 W5-PAR41-72a I 45L I CW X SAS 3119105 WS-PAR-61-72a 2 46L I CCW X SAS 3119105 W5"PAR-61-72a 3 45L I CW X SAS 3/19105 W6-PAR-61-72a 4 46L I CCW X SAS 3119105 WS-PAR-61-72a 5 45S / CW X SAS 3119105 WS-PAR-61-72a 6 45S I CCW X SAS 3119105 WS-PAR-61-72a 7 45S I CCW X SAS 3/19t05 WS-PAR-61-72a 8 45L I CW _ _ SAS 3119105 W6-PAR44-46a I 46L I CW X SAS 3119105 WS&PAR-34-46a 2 45L I CCW X SAS 3/19105 WS-PAR-34-46a 3 4SL I CW X SAS 3119105 WS-PAR-34-46a 4 45L I CCW X SAS 3119105 WS-PAR-34-46a 5 45S I CW X SAS 3/19105 WS-PAR-34-46a 6 45S I CCW X SAS 3119105 W5-PAR-34-46a 7 45S I CCW X SAS 3119105 WS-PAR-34-46a 8 46L I CW _ _ SAS 3/19105 E R L.
EXAMINER LEVEL DATE
^ r {< _
PLANT I UNIT McGOURE 12 OPTICAL DISK #
UP3 UA YS Y PROCEDURE: PDI4SI-254 REVISION: 7 WELD # WELD TYPE:
.RPV-W01 LOWER HEAD TO BOTTOM HEAD CIRC ANALYSIS LOG Calibration Data Sheet No. LSI - LS8 Acquisition Log Sheet No. W5-I, WS-2, W5-3 Analysis Log Sheet No. WS-18 W5-PAR417-34a I 45L I CW X SAS 3M19105 W5-PAR-17-34a 2 45L I CCW X SAS 3119/05 W5-PAR-17-34a 3 45L I CW X SAS 3119105 W5-PAR-17-34a 4 45L I CCW X SAS 3M19105 WS-PAR-17-34a 5 45S I CW X SAS 3119105 W5-PAR-17-34a 6 45S I CCW X SAS 3119105 W5-PAR-17-34a 7 45S9 CCW X SAS 3119105 WS-PAR-17-34a 8 45L 1CW _ _ SAS 3119105 W5-PAR-287-304a 1 45L I CW X SAS 3M19/05 W5-PAR-287-304a 2 45L I CCW X SAS 3119105 W5-PAR-287-304a 3 45L / CW X SAS 3119/05 W5-PAR-287-304a 4 45L I CCW X SAS 3M19105 W5-PAR-287-304a 5 45S3 CW X SAS 3/19105 WS-PAR-287-304a 6 45S9/ CCW X SAS 3119105 W5&PAR-287-304a 7 45S / CCW X SAS 3/19/05 WS-PAR-287-304a 8 45L I CW SAS 3119/05
__ __ __ __ __ __ __ __ __ __ __ ___I_
.z LEE DT XAINE EXAMINER LEVEL 22z: DATE
-- Jr
PLANT I UNIT McOUIRE 12 OPTICAL DISK #
N I11 11i.PYNE PROCEDURE: PDII-254 REVISION: 7 WELD # WELD TYPE:
2RPV-WO1 LOWER HEAD TO BOTTOM HEAD CIRC ANALYSIS LOG Calibration Data Sheet No. LSI - LS8 Acquisition Log Sheet No. W5-1, W5-2, W5-3 Analysis Log Shee No. W6-19 W5-PAR-304-316a I 45L I CW X SAS 3119105 W-PAR-304-316a 2 45L ICCW X SAS 3/1905 W5-PAR-304-316a 3 45L I CW X SAS 3119105 W5-PAR-304-316a 4 45LICCW X SAS 3119105 W5-PAR-304-316a 8 45 I CW X SAS 3119105 W5-PAR-304-316a 5 45S I CCW X SAS 3119105 W5-PAR-304-316a 7 45S3 CCW X SAS 3M9105 W"-AR-304-316a a 45L/ICW -- SAS 3/19105 W5-PAR-224-231a I 45L/ CW X SAS 3119/05 W5-PAR-224-236a 2 45L I CCW X SAS 3M19105 W5-PAR-224-23a 3 45L I CW X SAS 3119105 W5-PAR-224-236a 4 45L I CCW X SAS 3119105 W5-PAR-224-236a a 453 I CW X SAS 3M19105 WS-PAR-224-236a a 453ICCW X SAS 3/19105 W,-PAR-224-236a 7 45S, CCW X SAS 3119105 W5-PAR-224-236a a 45L I CW X SAS 3119105
. XMI LEE.DT
-A243 r45S C -
EXAMINER LEVEL DATE
- Xrsfr--
PLANT I UNIT Mc0UIRE /2 OPTICAL DISK
- Dm PROCEDURE: PDI-Io-254 REVISION: 7 WELD # WELD TYPE:
2RPV-WOI LOWER HEAD TO BOTTOM HEAD CIRC ANALYSIS LOG Calbmtlon Data Sheet No. LS1 - LS8 Acquisition Log Sheet No. WS-1, WS-2, W6-3
_____ __ __ __ _ __ __ __ __ __ __Analysis Log Sheet No. WS-20 W6 PAR.134.146b I 45L/CW X ll SAS 3118105 W6-PAR-134-146b 2 46L/ICCW` X lSAS 3/91905 W6-PAR-134-146b 3 46L5/CW X SAS 3M9105 W6-PAR-134-146b 4 45L / CCW X SAS 3119105 WS-PAR-134-146b 3 45S/ CW X SAS 3119105 W6-PAR-134-146b 6 46S I CCW X SAS 3119105 WS-PAR-134-146b 7 45SI CCW X SAS 3119105 W5-PAR-134-146b 6 46L5/CW X SAS 3/19105 W6-PRP-102-109 7 45L I DN X CHL 3119105 WS-PRP-102-109 2 45L I UP X CHL 3119105 W5-PRP-102-109 3 46L/ DN X CHL 3119105 WS-PRP-1024109 3 45S I DN, X CHL 3M19105 WS-PRP41024109 4 45L I UP X CHL 3119105 W5-PRP-102-109 6 46S/ UP X CHL 3119/05 W5-PRP-102-109 7 45SI UP X CHL 3/19/05 W5-PRP-102-109 8 4511/DN X CHL 3/19105 EXAI=E '~_b ee LVLDT EXAMINER _z=
Cm A~n v kee LEVEL DATE 3//7 g/. DI
PLANT I UNIT McGLUIRE 12 OPTICAL DISK 0 N WI PROCEDURE: PDI.14-24 REVfSION: 7 WELD # WELD TYPE:
2RPV-W01 LOWER HEAD TO BOTTOM HEAD CIRC ANALYSIS LOG Calibration Data Sheet No. LS1 - LS8 Acquisition Log Sheet No. W5-1, W5-2, W-3
_ Analysis Log Sheet No. WS-21 m f- -
W5-PRP-71-102 I 45L I ON X CHL 3M9105 WSPRP-71-102 2 45L I UP X CHL 3M19105 W5-PRP-71-102 3 45L I DN X CHL 3M19105 W5-PRP-71-102 4 45L I UP X CHL 3119105 W5-PRP-714102 5 453 1DN X CHL 3M19M5 WS-PRP-714-02 6 4531 UP X CHL 3119105 W5-PRP-71-102 7 45S I UP X CHL 3M9105 W5-PRP-71-102 8 45L I DN X CHL 3M9105 EXAMNER /un e~ LVEL ATE.
EXAMINER Chana Nluo te,- LEVEL DATE Oa -m - °t
_ PLANT MCOURE Ufa 2 PROCEDURE Po -254 REV. 7 INDICATION ASSESSMENT ANALYST -LEVEL M DATIE 91 0 P t A K 33S 1202 WA 2RP 1 45 UIP P 5.59 1.3811.50 1.1 MMB 1.21 1.0 01410.07 064 1.25 2.28 32 11-S' 54.5' 1.28 (1) 182 WA 2RPV- 2 45 UP P 5N9 1.3211.60 0. SUB 1.17 1.0 0281014 .233 Z5 &63 49 349.4* 54.? 1.46 (1) 134-2 WA 2RPV-WOI 3 45 Cow P 5.9 0.4310.5 1.0 SWB 043 1.0 .125/0Q6 .063 1.12 2.28 6 57.3* 128W 5.20 (1)
W5RP-329. WA 2RPV-I 4 45 N P 559 3.3/3.46 .75 m 3.18 1.0 0.12510.063 .083 1.12 2.40 99 351.0 54.r 39 (1)
W22-1 WA 2RNPWO 5 45 OM P 5lg 0Q45/017 1.1 SU 0.3 1.0 0.125/0.063 .057 1.12 2.24 62 322.6' 54.9 0.5 WW*& A 2RW 6 45 _ P 559 144/1.58 1.1 SUB 1.29 1.0 Q125/083 .057 1.12 2.24 98 30.19' 55M 1.5 (1)
W WA 2R .M1 7 45 UP P 5.59 1.08/1.19 3. SU 0.91 1.0 0.125/0.063 0.17 1.12 2.00 70 283.6' 54. 1.12 (1) 2M WA 2RP.M1 8 45 ON P 5.59 1.3411.54 1. SUB 1.19 1.0 Q20/Q10 .083 1.79 228 65 28.r 5+- . 1.44 (1) 281 2854 WA 2RPV.4 9 45 _N P 5.59 1.32/1.52 1.6 S 1.17 1.0 0.20/0.10 .083 1.79 2.28 100 281.2' 54.r2' 142 (1)
=- - -__--- __ __ - -_ =- -_ -_
NOTES (1) COD ALLOWABLE PERASME! 1989, WB-35101 eombas out Sheet hed-No L .
Aeq*ubofn Log Sheet No. W541m Anflyds Log Sheet No W57.AI0.11.1
.edcaen A..n .at Pag 1I t1
WesDyne International 2005 WesDyne International 2005 1 £( t 01o2. . an $?9'I SWE -o*
WesDyne International 2005
WesDyne Intemationel 2005 i
)
WesDyne International 2005
WesDyne International 2005 WesOyne Intemntional 2005 I WAIN Wesoyne International 2005
4d'/ t(ozfO7.z 95-r-4 NesDyne International 2005
Y OUTAGE:
PLANT I UNIT INTERVAL:
INTERVAL: PERIOD: OUTAGE:
[fa INVON ms~pynE 006A McGUIRE /2 2 3 2EQC16 PROCEDURE: REVISION:
PD14St-254 7 W!-PAR-224-236 2RPV-W01 58.30 224.00 KRS IT 3119105 WS-PAR-236-287 2RPV-W01 58.30 236.25 KRS IT 3119105 WS-PAR-287-304 2RPV-W01 58.30 287.50 KRS IT 3119105 W5-PAR-304-316 2RPV-W0I 58.30 304.25 KRS IT 319105 W5-PAR-316-17 2RPV-W01 58.30 316.00 KRS IT 3119105 WS-PAR-17-34 2RPV-W0I 58.30 17.60 KRS IT 3119105 W5-PAR-34-46 2RPV-W01 58.30 34A0 KRS IT 3119105 W5-PAR-46-61 2RPV-WOt 58.30 46.00 KRS IT 3M9105 W5-PAR-61-72 2RPV-WOt 58.30 61.00 KRS IT 3119105 WS-PAR-72-134 2RPV-W0l 58.30 72.50 KRS IT 3M9105 W5-PAR-146.180 2RPV-W01 58.30 146.30 KRS IT 3119105 W5-PRP-175-191 2RPV-W01 175.00 58.30 KRS IT 3119105 WS-PRP-168-175 2RPV-W01 168.25 58.30 KRS IT 3119105 W5-PRP-145-168 2RPV-W01 145.00 58.30 KRS IT 3119105 W5-PRP-135-145 2RPV-W01 135.50 58.30 KRS IT 3119105 W5-PRP-127-135 2RPV-WQ1 127.00 58.30 KRS IT 3119105 W5-PRP-120-127 2RPV-WOI 120.00 58.30 KRS IT 3119105 W5-PRP-109-120 2RPV-W01 109.25 58.30 KRS IT 3M19105 W5-PRP-102-109 2RPV-WOI 102.00 58.30 KRS IT 3M19105 W5-PRP-71-102 2RPV-W01 71.50 58.30 KRS IT 319105 U U U a - a
INTERVAL PERIOD: OUTAGE:
PLANT II UNIT PLANT UNIT INTERVAL: PERIOD: OUTAGE:
McGUIRE /2 2 3 2EOC16 m Iw U UnE PROCEDURE: REVISION:
PD1181-254 7 DATA ACQUISMON LOG W5-PRP-62-71 l 2RPV-WOI 62.00 58.30 KRS IT 3119105 WS-PRP44-62 2RPV-WO1 44.50 58.30 KRS IT 3M19105 W5-PRP-35-44 2RPV-W01 35.00 58.30 KRS IT 3119105 W5-PRP-28-35 2RPV-W01 28.00 58.30 KRS IT 3119105 W5-PRP-18-28 2RPV-W01 18.50 58.30 KRS IT 3119105 W5-PRP-329-18 2RPV-WOI 329.75 58.30 KRS IT 3119105 W5-PRP-322-329 2RPV-WOI 322.50 58.30 KRS IT 3119105 W5-PRP-314-322 2RPV-WOI 314.50 58.30 KRS IT 3119105 W5-PRP-305-314 2RPV-WOI 305.00 58.30 KRS IT 3119105 W5-PRP-298-305 2RPV-W01 298.00 58.30 KRS IT 3119105 W5-PRP-288-298 2RPV-WOI 288.50 58.30 KRS IT 3119105 W5-PRP-281-288 2RPV-W40 281.50 58.30 KRS IT 3119105 W5-PRP-274-281 2RPV-W01 274.50 58.30 KRS IT 3119105 WS-PRP-235-274 2RPV-W0I 235.00 58.30 KRS IT 3119105 W5-PRP-225-235 2RPV-W01 225.50 58.30 KRS IT 3119105 W5-PRP-199-225 2RPV-W01 199.25 58.30 KRS IT 3119105 W5-PRP-191-199 2RPV-W01 191.25 58.30 KRS IT 3119105 W5-PAR61-72a 2RPV-W01 58.30 61.00 JCAS n 3119105 WS-PAR34-46a 2RPV-W01 58.30 164.55 JCAS n 3119105 W5-PAR17-34a 2RPV-WN0 58.30 17.60 JCAS n 3119105 W5-PAR-287-304a 2RPV-W0I 58.30 287.50 JCAS 11 3119105
PLANT / UNIT INTERVAL: PERIOD: OUTAGE:
Is ynE McGUIREI2 2 3 2EOCIG 1MWM*W*Mft... PROCEDURE: REVISION:
PDI4SI-254 7 DATA ACQUISION LOG W54PAR-304-315a ZRPV-VVU1 58.u JGAS n 3119105 W5"PAR-224-236a 2RPV-W01 58.30 224.00 JCAS II 311 9/05 WS-PAR-134-146b 2RPV-W0 1 5830 134.00 JCAS II 3/19/05 1IIII I I_
I I l I I t I_
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. bUKE POWER SITE .............. McGUIRE UNIT #2 OUTAGE ............... 2EOC16 VESSEL TYPE .- ............. WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W5-PAR-180-224 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 58.30 180.00 TOP RIGHT 58.30 224.00 BOTTOM LEFT 50.70 180.00 BOTTOM RIGHT : 50.70 224.00 Index Size (in) = 0.50 Number of Indexes Specified = 25 Number of Indexes Completed = 25 Time Date Scan Started 02:47:46.675 03/19/05 Scan Completed 03:02:47.987 03/19/05 Robot Operator Signature 4 K DATE 3-f -a-PARAGON Operator Signature 4 4
& ,f7 s DATE
, eW Comments t. AX D' -
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER . DUKE POWER SITE . MCGUIRE UNIT #2 OUTAGE . 2EOC16 VESSEL TYPE . WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W5-PAR-224-236 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 58.30 224.00 TOP RIGHT 58.30 236.25 BOTTOM LEFT 54.30 224.00 BOTTOM RIGHT 54.30 236.25 Index Size (in) = 0.50 Number of Indexes Specified = 14 Number of Indexes Completed = 14 Time Date Scan Started 10:19:19.611 03/19/05 Scan Completed 10:20:52.765 03/19/05 Robot Operator Signature , DATE2L/~f' PARAGON Operator Signature k~fe DATE 2e/ 2464 Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W5-PAR-236-287 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 58.30 236.25 TOP RIGHT 58.30 287.50 BOTTOM LEFT 50.70 236.25 BOTTOM RIGHT 50.70 287.50 Index Size (in) = 0.50 Number of Indexes Specified = 25 Number of Indexes Completed = 25 Time Date Scan Started 03:10:01.806 03/19/05 Scan Completed 03:18:49.965 03/19/05 Robot Operator Signature LJDATE 3-4I1O PARAGON Operator Signature -,X". A6 Y, DATE 3iy -;. . . ...I-
..a, Comments I
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER . DUKE POWER SITE . McGUIRE UNIT #2 OUTAGE . 2EOC16 VESSEL TYPE . WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W5-PAR-287-304 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 58.30 287.50 TOP RIGHT 58.30 304.25 BOTTOM LEFT : 52.70 287.50 BOTTOM RIGHT 52.70 304.25 Index Size (in) = 0.50 Number of Indexes Specified = 19 Number of Indexes Completed = 19 Time Date Scan Started 09:56:20.263 03/19/05 Scan Completed 09:59:06.144 03/19/05 Robot Operator Signature t,,, - DATE IZ fL&
PARAGON Operator Signature /Ii SDATE_//V/o)
Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W5-PAR-304-316 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 58.30 304.25 TOP RIGHT 58.30 316.00 BOTTOM LEFT 55.00 304.25 BOTTOM RIGHT 55.00 316.00 Index Size (in) = 0.50 Number of Indexes Specified = 12 Number of Indexes Completed = 12 Time Date Scan Started 09:49:45.735 03/19/05 Scan Completed 09:51:03.814 03/19/05 Robot Operator Signature 9-; , . l DA_ - DATEIZ/ie!&*i PARAGON Operator Signature &k~- DATEg*~Vkr Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .............. DUKE POWER SITE .............. McGUIRE UNIT #2 OUTAGE .............. 2EOC16 VESSEL TYPE . ............ WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WOI Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W5-PAR-316-17 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT : 58.30 316.00 TOP RIGHT 58.30 377.60 BOTTOM LEFT : 50.70 316.00 BOTTOM RIGHT 50.70 377.60 Index Size (in) = 0.50 Number of Indexes Specified = 25 Number of Indexes Completed = 25 Time Date Scan Started 03:28:07.516 03/19/05 Scan Completed 03:35:46.559 03/19/05 Robot Operator Signature PARAGON Operator Signature Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER . DUKE POWER SITE . McGUIRE UNIT #2 OUTAGE . 2EOC16 VESSEL TYPE . WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W01 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W5-PAR-17-34 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 58.30 17.60 TOP RIGHT 58.30 34.40 BOTTOM LEFT 52.00 17.60 BOTTOM RIGHT 52.00 34.40 Index Size (in) = 0.50 Number of Indexes Specified = 21 Number of Indexes Completed = 21 Time Date Scan Started 09:35:15.029 03/19/05 Scan Completed 09:38:24.061 03/19/05 Robot Operator Signature &i=2-7 h/i1- DATEV/va.° PARAGON Operator Signature {/z DATEA3/Ž4
-/
Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W01 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W5-PAR-34-46 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 58.30 34.40 TOP RIGHT 58.30 46.00 BOTTOM LEFT 54.30 34.40 BOTTOM RIGHT 54.30 46.00 Index Size (in) = 0.50 Number of Indexes Specified = 14 Number of Indexes Completed = 14 Time Date Scan Started 09:26:52.303 03/19/05 Scan Completed 09:28:25.210 03/19/05 Robot Operator Signature
/O-- -DATE Z k/2&l &N PARAGON Operator Signature I- ;-
~;,O,
__DATE4 &Z 4
- Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W01 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W5-PAR-46-61 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 58.30 46.00 TOP RIGHT 58.30 61.00 BOTTOM LEFT 50.70 46.00 BOTTOM RIGHT : 50.70 61.00 Index Size (in) = 0.50 Number of Indexes Specified = 25 Number of Indexes Completed = 25 Time Date Scan Started 03:43:49.886 03/19/05 Scan Completed 03:46:23.581 03/19/05 Robot Operator Signature J/c r%1A TEL "-( -0 .
PARAGON Operator Signature Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER . DUKE POWER SITE . McGUIRE UNIT #2 OUTAGE . 2EOC16 VESSEL TYPE . WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W01 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = WS-PAR-61-72 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 58.30 61.00 TOP RIGHT 58.30 72.50 BOTTOM LEFT 53.10 61.00 BOTTOM RIGHT 53.10 72.50 Index Size (in) = 0.50 Number of Indexes Specified = 18 Number of Indexes Completed = 18 Time Date Scan Started 09:15:48.429 03/19/05 Scan Completed 09:17:41.452 03/19/05 Robot Operator Signature
- Ac aPATE YZV/ e PARAGON Operator Signature .I qO., &- JDATE-2L~4 Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W5-PAR-72-134 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT : 58.30 72.50 TOP RIGHT : 58.30 134.00 BOTTOM LEPT . 50.70 72.50 BOTTOM RIGHT 50.70 134.00 Index Size (in) = 0.50 Number of Indexes Specified = 25 Number of Indexes Completed = 21 Time Date Scan Started 03:50:41.414 03/19/05 Scan Completed 04:05:35.710 03/19/05 Robot Operator Signature 7Vt At x DATE 43 de So PARAGON Operator Signature Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER ..............DUKE POWER SITE .............. McGUIRE UNIT #2 OUTAGE .............. 2EOC16 VESSEL TYPE .. ............ WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W5-PAR-146-180 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 58.30 146.30 TOP RIGHT 58.30 180.00 BOTTOM LEFT 50.70 146.30 BOTTOM RIGHT : 50.70 180.00 Index Size (in) = 0.50 Number of Indexes Specified = 25 Number of Indexes Completed = 23 Time Date Scan Started 04:11:04.564 03/19/05 Scan Completed 04:18:46.266 03/19/05 Robot Operator Signature /A ,JA DATE 3 -O-7 PARAGON Operator Signature . ^-l twill -DATE ____
Comments _5764_, zq-?- 25 -k>W - -ej+<o
-7 f~aun coo - -I
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W5-PRP-175-191 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 175.00 58.30 TOP RIGHT 191.25 58.30 BOTTOM LEFT 175.00 50.70 BOTTOM RIGHT 191.25 50.70 Index Size (in) = 0.50 Number of Indexes Specified = 52 Number of Indexes Completed = 52 Time Date Scan Started 04:27:59.150 03/19/05 Scan Completed 04:35:34.794 03/19/05 Robot Operator Signature PARAGON Operator Signature Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W5-PRP-168-175 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 168.25 58.30 TOP RIGHT 175.00 58.30 BOTTOM LEFT 168.25 50.90 BOTTOM RIGHT : 175.00 50.90 Index Size (in) = 0.50 Number of Indexes Specified = 22 Number of Indexes Completed = 22 Time Date Scan Started 04:39:08.049 03/19/05 Scan Completed 04:40:47.314 03/19/05 Robot Operator Signature j /4 DATE 3-LL-<
PARAGON Operator Signature 4IV Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE .............. McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W5-PRP-145-168 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 145.00 58.30 TOP RIGHT 168.25 58.30 BOTTOM LEFT 145.00 50.70 BOTTOM RIGHT : 168.25 50.70 Index Size (in) = 0.50 Number of Indexes Specified = 73 Number of Indexes Completed = 73 Time .Date Scan Started 04:42:36.755 03/19/05 Scan Completed 04:48:21.466 03/19/05 Robot Operator Signature LDATE 311-(0<
PARAGON Operator Signature 1Afll' /, " flTM31 f/' Lr-Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W5-PRP-135-145 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 135.50 58.30 TOP RIGHT 145.00 58.30 BOTTOM LEFT 135.50 57.30 BOTTOM RIGHT 145.00 57.30 Index Size (in) = 0.50 Number of Indexes Specified = 31 Number of Indexes Completed = 31 Time Date Scan Started 04;51:34.764 03/19/05 Scan Completed 04:52:50.746 03/19/05 Robot Operator Signature nwu~a 4DATE 39--0F PARAGON Operator Signature Comments
WeoDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W5-PRP-127-135 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 127.00 58.30 TOP RIGHT 135.50 58.30 BOTTOM LEFT 127.00 50.70 BOTTOM RIGHT 135.50 50.70.
Index Size (in) = 0.50 Number of Indexes Specified = 28 Number of Indexes Completed = 28 Time Date Scan Started 04:54:28.286 03/19/05 Scan Completed 04:56:38.327 03/19/05 Robot Operator Signature DATE 3L-(.1'-
,n4~k4 iA, PARAGON Operator Signature 0 An.,
- - P-or DATPR1-'~
S _ o Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W01 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W5-PRP-120-127 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 120.00 58.30 TOP RIGHT 127.00 58.30 BOTTOM LEFT 120.00 52.10 BOTTOM RIGHT 127.00 52.10 Index Size (in) = 0.50 Number of Indexes Specified = 23 Number of Indexes Completed = 23 Time Date Stan Started 04:58:12.375 03/19/05 Scan Completed 04:59:41.882 03/19/05 Robot Operator Signature , Jo DATE 3______
PARAGON Operator Signature ADATE3-.-
Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ...............WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W5-PRP-109-120 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 109.25 58.30 TOP RIGHT 120.00 58.30 BOTTOM LEFT 109.25 50.70 BOTTOM RIGHT 120.00 50.70 Index Size (in) = 0.50 Number of Indexes Specified = 35 Number of Indexes Completed = 35 Time Date Scan Started 05:01:00.722 03/19/05 Scan Completed 05:03:42.179 03/19/05 Robot Operator Signature 174, DATE.. -jf-° PARAGON Operator Signature ~ zeC DATE S21.T Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER ............. DUKE POWER SITE . McGUIRE UNIT #2 OUTAGE .............. 2EOC16 VESSEL TYPE . WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W5-PRP-102-109 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 102.00 58.30 TOP RIGHT 109.25 58.30 BOTTOM LEFT 102.00 52.70 BOTTOM RIGHT 109.25 52.70 Index Size (in) = 0.50 Number of Indexes Specified = 24 Number of Indexes Completed = 24 Time Date Scan Started 05:05:07.361 03/19/05 Scan Completed 05:06:41.001 03/19/05 Robot Operator Signature JR DATE 3 -[-0s PARAGON Operator Signature &4< DATE Xd/*° Comments
WesDyne International Reactor Vessel InserVice Examination Scan Parameter Execution
)
CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = WS-PRP-71-102 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 71.50 58.30 TOP RIGHT 102.00 58.30 BOTTOM LEFT 71.50 50.70 BOTTOM RIGHT : 102.00 50.70 Index Size (in) = 0.50 Number of Indexes Specified = 95 Number of Indexes Completed = 95 Time Date Scan Started 05:08:26.513 03/19/05 Scan Completed 05:15:50.793 03/19/05 Robot Operator Signature qJA DATE 3jfO6 PARAGON Operator Signature I A L4 DATE.3L-Y Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER ............... DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE .. ............. WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W5-PRP-62-71 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 62.00 58.30 TOP RIGHT 71.50 58.30 BOTTOM LEFT 62.00 55.60 BOTTOM RIGHT : 71.50 55.60 Index Size (in) = 0.50 Number of Indexes Specified = 31 Number of Indexes Completed = 31 Time Date Scan Started 05:18:02.908 03/19/05 Scan Completed 05:19:34.540 03/19/05 Robot Operator Signature -DATE 3d4-ol PARAGON Operator Signature i4/A Z A- DATE3$ L2 Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W5-PRP-44-62 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 44.50 58.30 TOP RIGHT 62.00 58.30 BOTTOM LEFT 44.50 50.70 BOTTOM RIGHT : 62.00 50.70 Index Size (in) = 0.50 Number of Indexes Specified = 55 Number of Indexes Completed = 55 Time Date Scan Started 05:20:56.997 03/19/05 Scan Completed 05:25:11.919 03/19/05 Robot Operator Signature DATE ______
PARAGON Operator Signature -. 4 ) DATE 5-/-
L Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE . McGUIRE UNIT #2 OUTAGE . 2EOC16 VESSEL TYPE . WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W5-PRP-35-44 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITIO14 AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 35.00 58.30 TOP RIGHT 44.50 58.30 BOTTOM LEFT : 35.00 57.30 BOTTOM RIGHT : 44.50 57.30 Index Size (in) = 0.50 Number of Indexes Specified = 31 Number of Indexes:Completed = 31 Time Date Scan Started 05:26:54.434 03/19/05 Scan Completed 05:28:10.725 03/19/05 Robot Operator Signature DA E 3-II 0 PARAGON Operator Signature Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. .............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W5-PRP-28-35 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 28.00 58.30 TOP RIGHT 35.00 58.30 BOTTOM LEFT : 28.00 50.70 BOTTOM RIGHT 35.00 50.70 I Index Size (in) = 0.50 Number of Indexes Specified = 23 Number of Indexes Completed = 23 Time D;ate Scan Started 05:29:19.349 03/19/05 Scan Completed 05:31:03.222 03/19/05 Robot Operator Signature v I DATR 3-flor PARAGON Operator Signature .l~ 4SL'1 DATE 2/ DATE.L2 ire Comments =L/Ixn iT4-O Al, -f C- A., --- Zle
, v
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution
)
CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ...............WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W5-PRP-281-288 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 281.25 58.30 TOP RIGHT 288.50 58.30 BOTTOM LEFT 281.25 50.70 BOTTOM RIGHT 288.50 50.70 Index Size (in) = 0.50 Number of Indexes Specified = 24 Number of Indexes Completed = 24 Time Date Scan Started 06:13:22.260 03/19/05 Scan Completed 06:16:22.935 03/19/05 Robot Operator Signature PARAGON Operator Signature Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE . McGUIRE UNIT #2 OUTAGE . 2EOC16 VESSEL TYPE . WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W01 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W5-PRP-274-281 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 274.50 58.30 TOP RIGHT 281.25 58.30 BOTTOM LEFT 274.50 50.90 BOTTOM RIGHT 281.25 50.90 Index Size (in) = 0.50 Number of Indexes Specified = 22 Number of Indexes Completed = 22 Time Date Scan Started 06:17:39.667 03/19/05 Scan Completed 06:19:18.808 03/19/05 Robot Operator Signature J DATE___3__-_
PARAGON Operator Signature L DA g^ T E 3 t< F Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER ..............DUKE POWER SITE .............. MCGUIRE UNIT #2 OUTAGE .............. 2EOC16 VESSEL TYPE .. ............ WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W5-PRP-235-274 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 235.00 58.30 TOP RIGHT 274.50 58.30 BOTTOM LEFT 235.00 50.70 BOTTOM RIGHT 274.50 50.70 I Index Size (in) = 0.50 Number of Indexes Specified = 123 Number of Indexes Completed = 123 Time Date Scan Started 06:20:58.023 03/19/05 Scan Completed 06:31:52.890 03/19/05 Robot Operator Signature 2
i~i4
/L Lf
-DATE 3L/ -W PARAGON Operator Signature nATE 3-/9-or Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution I
CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WOI Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W5-PRP-225-235 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 225.50 58.30 TOP RIGHT 235.00 58.30 BOTTOM LEFT 225.50 57.30 BOTTOM RIGHT 235.00 57.30 Index Size (in) = 0.50 Number of Indexes Specified = 31 Number of Indexes Completed = 31 Time Date Scan Started 06:34:36.571 03/19/05 Scan Completed 06:35:52.861 03/19/05 Robot Operator Signature PARAGON Operator Signature Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... MCGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTIN4GHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W01 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W5-PRP-199-225 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 199.25 58.30 TOP RIGHT 225.50 58.30 BOTTOM LEFT 199.25 50.70 BOTTOM RIGHT 225.50 50.70 Index Size (in) = 0.50 Number of Indexes Specified = 82 Number of Indexes Completed = 82 Time Date Scan Started 06:37:59.835 03/19/05 Scan Completed 06:44:32.380 03/19/05 Robot Operator Signature DATE3 -
PARAGON Operator Signature A & D -
Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution J
CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W01 Weld and Scan Type = HEAD CIRCUMFERENTIAL PERPENDICULAR SCAN Scan Data File Name = W5-PRP-191-199 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH MERIDINAL (DEGREES) (DEGREES)
TOP LEFT 191.25 58.30 TOP RIGHT 199.25 58.30 BOTTOM LEFT 191.25 52.70 BOTTOM RIGHT 199.25 52.70 Index Size (in) = 0.50 Number of Indexes Specified = 26 Number of Indexes Completed = 26 Time Date Scan Started 06:49:08.943 03/19/05 Scan Completed 06:50:50.731 03/19/05 Robot Operator Signature WA7&AW v J DATE 1d-05 PARAGON Operator Signature rTI-Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELDIDENTIFICATION - 2RPV-W01 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W5-PAR-61-72 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT : 58.30 61.00 TOP RIGHT 58.30 72.50 BOTTOM LEFT : 53.10 61.00 BOTTOM RIGHT : 53.10 72.50 Index Size (in) = 0.50 Number of Indexes Specified = 18 Number of Indexes Completed = 18 Time Date Scan Started 09:15:48.429 03/19/05 Scan Completed 09:17:41.452 03/19/05 Robot Operator Signature / DATES'I0f PARAGON Operator Signature i S DATE'97 f Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W5-PAR-34-46 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 58.30 34.40 TOP RIGHT 58.30 46.00 BOTTOM LEFT 54.30 34.40 BOTTOM RIGHT 54.30 46.00 Index Size (in) = 0.50 Number of Indexes Specified = 14 Number of Indexes Completed = 14 Time Date Scan Started 09:26:52.303 03/19/05 Scan Completed 09:28:25.210 03/19/05 Robot Operator Signature PARAGON Operator Signature Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W01 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = WS-PAR-17-34 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 58.30 17.60 TOP RIGHT 58.30 34.40 BOTTOM LEFT 52.00 17.60 BOTTOM RIGHT 52.00 34.40 Index Size (in) = 0.50 Number of Indexes Specified = 21 Number of Indexes Completed = 21 Time Date Scan Started 09:35:15.029 03/19/05 Scan Completed 09:38:24.061 03/19/05 Robot Operator Signature DATE __4_-__
,of Jo.
PARAGON Operator Signature KaA rdA- DATE 7q -OJ Comments
WesPyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ............... 2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W01 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W5-PAR-287-304 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 58.30 287.50 TOP RIGHT 58.30 304.25 BOTTOM LEFT 52.70 287.50 BOTTOM RIGHT : 52.70 304.25 Index Size (in) = 0.50 Number of Indexes Specified = 19 Number of Indexes Completed = 19 Time Date Scan Started 09:56:20.263 03/19/05 Scan Completed 09:59:06.144 03/19/05 Robot Operator Signature 7!1 .o$,JDATE S-MS5 PARAGON Operator Signature ^ _DATE 3_5 '1t Comments
WesDyne International Reactor Vessel Inservice Examinatibn Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W01 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W5-PAR-304-316 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 58.30 304.25 TOP RIGHT 58.30 316.00 BOTTOM LEFT 55.00 304.25 BOTTOM RIGHT 55.00 316.00
) Index Size (in) = 0.50 Number of Indexes Specified = 12 Number of Indexes Completed = 12' Time Date Scan Started 09:49:45.735 03/19/05 Scan Completed 09:51:03.814 03/19/05 Robot Operator Signature PARAGON Operator Signature Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .. ............. DUKE POWER SITE ............... McGUIRE UNIT #2 OUTAGE ...............2EOC16 VESSEL TYPE ............... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W01 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = WS-PAR-224-236 SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 58.30 224.00 TOP RIGHT 58.30 236.25 BOTTOM LEFT 54.30 224.00 BOTTOM RIGHT : 54.30 236.25 Index Size (in) = 0.50 Number of Indexes Specified = 14 Number of Indexes Completed = 14 Time Date Scan Started 10:19:19.611 03/19/05 Scan Completed 10:20:52.765 03/19/05 Robot Operator Signature JA DATE 3 '
I PARAGON Operator Signature - 2DATE2Y-S5' Comments
WesDyne International Reactor Vessel Intervice Examination Scan Parameter Execution
)
CUSTOMER .. . DUKE POWER SITE .. McGUIRE UNIT #2 OUTAGE .. 2EOC16 VESSEL TYPE . .WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-WO1 Weld and Scan Type = HEAD CIRCUMFERENTIAL PARALLEL SCAN Scan Data File Name = W5-PAR-134-146a SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION MERIDINAL AZIMUTH (DEGREES) (DEGREES)
TOP LEFT 58.30 134.00 TOP RIGHT 58.30 146.30 BOTTOM LEFT . 53.40 134.00 BOTTFOM RIGHT 53.40 146.30 Index Size (in) = 0.50 Number of Indexes Specified = 17 Number of Indexes Completed 17 Time Date Scan Started .
11:09:02.186 03/19/05 Scan Completed 11:11:24.575 03/19/05 Robot O erator Signature I h- DA TETE PARAGON Operator Signature <
Comments 3 O5i9AV- .
REQUEST RELIEF 05-MN-003 ATTACHMENT 3 PAGES 1-7
WesDyne International Reactor Vessel Weld Results Summary McGUIRE UNIT 2 WELD NO. 2RPV-W15-SE DESCRIPTION Outlet Nozzle DM Weld (B05.010.005-5A) @ 220 2NC2F-1-1 (B05.130-001-1A)
LIMITATIONS NO D YES X COVERAGE = 84.38%
RESULTS NI RI NO. OF INDICATIONS 0 STATUS N/A EXAM DOCUMENTATION INDICATION DOCUMENTATION Wx ANALYSIS LOG DASSESSMENT SHEET
[i] ACQUISITION LOG [Z PARAGON HARD COPY
[X] SCAN PRINTOUT DOTHER ( specify)
[g COVERAGE BREAKDOWN
[-XI WESDYNE ANALYST
MoGUIRE UNIT 2 DIRECTION / ORIENTATION RPV COVERAGE ESTIMATE BREAKDOWNS PARALLEL SCANS CCW/CW PERP. SCANS UP/DN WELD OUTLET NOZZLE TO SHELL WELD WELD NO. 2RPV-WI5-SE & 2NC2F-1-1 DESCRIPTION @Ž220 BEAM ANGLES BEAM 450 L Dual 450 L Single 45°Shear DIRECTION VOLUME WELD VOLUME WELD VOLUME WELD VOLUME WEL VOLUME CCw
- 68.75
- 68.75
- 100 *100 Cw
- 68.75
- 68.75 IN 100 100 OUT 100 100 UT Coverage = 84.38%
= 100% and 122.95" to 124.38" from 70° to 248° and 2850 to 3600. ET used to supplement exam for full coverage.
ANALYST
WESDyne
.N"E.ATIS...^
Page I of I ANALYSIS LOG # W15-1 I Disk No: I N/A Utility: DUKE POWER Plant: McGUIRE Unit: 2 l Outage: 2EOC16 Procedure No: I PDI-41-254-SE i Procedure Rev. No.: 2 Weld No: 2RPV-W15,SE, 2NC2F-1-1 Weld Type: I DM Exam. Surface: ID Applicable Senstv Calibration Data Sheet No: l SE-01 Acquisition Log No: W15-1 PARAGON Anal. Release: 6.1.3 UT Examiner Svgnature: Levl: _ Date 03/18/05 Data File Name UT Beam Angle I NM RI RI Examiner ID / Date Channel Beam Direction Resolution I Comments / Limiations No.
1er70LCwfaCoW0 WN22-SE-PAR-DET-ON I 70L CCW X DN / 03/18/05 WN22-SE-PAR-DET-ON 2 70L CW X _________________ DN /03/18/05 WN22-SE-PRP-DET-ON I 70L IN X _DN 03/1805 WN22-SE-PRP-DET-ON 2 70L OUT X DN I 03/18/05 Form 125 PD1I4S-254-SE, Rev. 2
M VES14-D~fE
- M II EU NAT I* BOA LAg Form 12.5: ET Analysis Log Utillty: Duke Power Procedure No WDI-STD146 Plant McGuire Unit 2 Procedure Rev. No.: 3 rn Outage: 2EOC16 Weld Now 2RPV.W15-SEI 2NC2F1-1l Weld Type: Safe End Applicable SensltM"t Calibration Data Sheet No: ET-l Acquisition Log No: W-15W1 ET Examiner Snauhne: (AJ eQ zoJ,/ Level Ill Daft: 3-190S Data ET ET Probe Scan NI RI RI Examiner ID I Date Fle Name Probe Diction Resolution I Comments I Umitatlons No. 1IRCC 31 Wffl=EPARDETON 4 CIRC X CSW I 3.19"S
IWi M WmD ws suatAI ,YnE Page of DATA ACQUISITION LOG # W15-1 Uility: I DUKE P R Plait: McGUIRE Unit 2 Outage: I 2EQC16 Procedure No: I PDI4IS-254-SE Procedure Rev. No.: 2 Applicable Sensivity Calibration Dat Sheet No: SE-01 UT Examiner Slgnature: __Level: __ Dat:e 03118105 Data File Name Weld No. Index Scan Total # 'AVE9 Gain Date Time Comments start Start of Signal AdJ.
Sweeps Amplitude (dB) $'
WN22-SE-PAR-DET-ON 2RPV-W15SE 122 0° 69 7 0 RAB 03/18105 1805 2N C2F-1-1_ _ _ _ _
WN22-SE-PAR-DET-ON 2RPV-WN21SE 122 0 6 9 7 0 RAB 03/18105 1805 2NC 2F 1 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _
WN22-SE-PRP-DET-ON 2RPV-W15.SE 0, 109.98 373 10 0 RAB 03/18/05 1936 2NC2F-1-1 WN22-SE-PRP-DET-ON 2RPV-W15&SE 0 109.98 373 10 0 RAB 03/18/05 1936 2NC2F 1-1 Form 124 PDIISI-254-SE, Rev. 2
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER ... ....... DUKE POWER SITE .......... McGUIRE UNIT #2 OUTAGE ... ....... 2EOC16 VESSEL TYPE .......... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W15-SE Weld and Scan Type = NOZZLE SAFE END PARALLEL SCAN S.can Data File Name = WN22-SE-PAR-DET-ON SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION DEPTH AZIMUTH (IN) (DEGREES)
START CW 122.00 179.90 END CCW 122.00 -179.90 START CW 127.50 179.90 END CCW 127.50 -179.90 Index Size (in) = 0.08 Number of Indexes Specified = 70 Number of Indexes Completed = 70 Time Date Scan Started 18:05:09.685 03/18/05 Scan Completed
^ 19:22:27.207 03/18/05 Robot Operator Signature PARAGON Operator Signature Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .... ....... DUKE POWER SITE ... ........ McGUIRE UNIT #2 OUTAGE ... ........ 2EOC16 VESSEL TYPE ........... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W15-SE Weld and Scan Type = NOZZLE SAFE END PERPENDICULAR SCAN Scan Data File Name = WN22-SE-PRP-DET-ON SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH DEPTH (DEGREES) (IN)
START CW 179.90 109.98 END CCW -179.90 109.98 START CW 179.90 125.50 END CCW -179.90 125.50 Index Size (in) = 0.24 Number of Indexes Specified = 373 Number of Indexes Completed = 373 Time 1Date Scan Started 19:37:05.063 03/18/05 Scan Completed 20:17:38.425 03/18/05 Robot Operator Signature DOW m ...Q~a files;-as- -
PARAGON Operator Signature nA-P-P,-5-1Q I
0 Comments
REQUEST RELIEF 05-MN-003 ATTACHMENT 4 PAGES 1-7
A7M(6*HEIuT7'f WesDyne International Reactor Vessel Weld Results Summary McGUIRE UNIT 2 WELD NO. 2RPV-W17-SE DESCRIPTION Outlet Nozzle DM Weld (B05.010.007-7A) @ 2020 2NC2F-3-1 (B05.130-009-9A) @ 2020 LIMITATIONS NO D YES I COVERAGE = 80.24%
RESULTS NO. OF INDICATIONS 0 STATUS N/A EXAM DOCUMENTATION INDICATION DOCUMENTATION
[g ANALYSIS LOG D-ASSESSMENT SHEET i- ACQUISITION LOG D-PARAGON HARD COPY
[X] SCAN PRINTOUT D]OTHER (specify))
W COVERAGE BREAKDOWN WESDYNE ANALYST
McGuire Unit 2 DIRECTION / ORIENTATION RPV COVERAGE ESTIMATE BREAKDOWNS PARALLEL SCANS CCW/CW PERP. SCANS IN/OUT WELD OUTLET NOZZLE DM WELDS @ WELD NO. 2RPV-W17-SE & 2NC2F-3-1 DESCRIPTION 2020 BEAM ANGLES BEAM 450 L Dual 450 L Single 450 Shear DIRECTION WELD VOLUME WELD VOLUME WELD VOLUME WELD VOLUME WELD VOLUME CCW 60.48 60.48 100 100 CW 60.48 60.48 IN 100 100 OUT 100 100 UT Coverage = 80.24%
ANALYST_ __
@I vw=su~
Page I of I ANALYSIS LOG # W17-1 I Disk No: I N/A Utility: DUKE POWER Plant: McGUlIRE Unit: 2 [ Outage: 2EOC16 Procedure No: PDI-ISI-254SE I Procedure Rev. No.: 2 Weld No: 2RPV-W17-SE, 2NC2F-3-1 Weld Type: DM Exam. Surface: ID Applicable Sensitivity Calibration Data Sheet No: SE I Acquisition Log No: W17-1 PARAGON Anal. Release: 6.1.3 UT Examiner Signature: / J _ _ _ Level: It Dte: 03M8/(05 Data File Name UT Beam Angle I NI RI RI Examiner ID / Date Channel Beam DirKetion Resolution I Comments / Umitations WN202-SE-PAR-DET-ON l 70 CCW X CSWI 03/18/05 WN202-SE-PAR-DET-ON 2 70 CW X CSW/ 03/18/05 WN202-SE-PRP-DET-ON 1 70 IN X _ CSW 103/18/05 WN202-SE-PRP-DET-ON 2 70 OUT X CSW/ 03/18/05 Form 12.5 PD1481-254-SE, Rev. 2
MWESDyN NiRN?
w .. ynE Fonn 12.5: ET Analysis Log W17-1 lDls No' r I WIA UfLmy DUKE POWER Plant: McGUIRE Unift 2 Outage: 2EOC16 Procedure No WDISTD148 l Procedure Rev. No.: 3 Weld No. 2RPV.W17-SE, 2NC2FP3-1 Weld Type: SAFE END Applicable SensItIvIty Callbraflon Data Sheet No ET-1 Acqulsitlon Log No: W174-ET Exanlner S3"abtJue: L Level II Date: 03119M Data ET ET Probe Sean Nl RI RI Examiner IDI Date Flle Name Probe DlMetlon Resolutlon / Comments I Llmiftatons WN202-SE-PAR-DON 4 CIRC X CSWI 03MI9W
m wusDyn I "to a HAT a A.,.
Page I of I DATA ACQUISITION LOG # W17-1 UtflltyI DUKE POWER Plant: I McGUIRE Unit: 2 Outage: 2EOC16 Procedure No: I PDI-ISI-254"SE Procedure Rev. No.: T 2 Applicable Sensitivity Calibration Data Sheet No: I SE-01 UT Examiner Signature: I =. l e I 1= j 0318105 Data Fife Name Weld No. Index Scan Total # 'AVE' Gain Date Time Comments Start Start of Signal Adj. ' .
Sweeps Amplitude (dB) ° 0
WN202-SE-PRP-DET-ON 2RPV-W¶7-SE 0 109.98e 373 9 0 DS 03/18105 0958 2NC2F-3-1 _ _ __ _ _ _ _ _
WN202-SE-PRP-DET-ON 2RPV-W17-SE 0 109.98e 373 10 0 DS 03118/05 0956 2NC2F-3-1 WN202-SE-PAR-DET-ON 2RPV-W17.SE 122 0 70 7 0 DS 03/18/05 1251 2NC2F-31 WN202-SE-PAR-DET-ON 2RPV-W17-$8- 122 0 70 8 0 DS 03118/05 1251
_2NC2F4.1 Form 124 PDI4SI-254-SE, Rev. 2
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .... ....... DUKE POWER SITE ........... McGUIRE UNIT #2 OUTAGE ........... 2EOC16 VESSEL TYPE ...... ..... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W17-SE Weld and Scan Type = NOZZLE SAFE END PERPENDICULAR SCAN Scan Data File Name = WN202-SE-PRP-DET-ON SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH DEPTH (DEGREES) (IN)
START CW : 179.90 109.98 END CCW -179.90 109.98 START CW 179.90 125.50 END CCW : -179.90 125.50 Index Size (in) = 0.24 Number of Indexes Specified = 373 Number of Indexes Completed = 373 Time Date Scan Started 09:16:04.009 03/18/05 Scan Completed 09:56:52.425 03/18/05 Robot Operator Signature 0 DATE 3-/8 6 PARAGON Operator Signatur DATE-,-
Comments
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .,. .......... DUKE POWER SITE .......... McGUIRE UNIT #2 OUTAGE ... ....... 2EOC16 VESSEL TYPE ..... ..... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W17-SE Weld and Scan Type = NOZZLE SAFE END PARALLEL SCAN Scan Data File Name = WN202-SE-PAR-DET-ON SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION DEPTH AZIMUTH (IN) (DEGREES)
START CW . 122.00 179.90 END CCW : 122.00 -179.90 START CW : 127.50 179.90 END CCW 127.50 -179.90 Index Size (in) = 0.08 Number of Indexes Specified = 70 Number of Indexes Completed = 70 Time Date Scan Started 11:33:48.077 03/18/05 Scan Completed 12:51:05.710 03/18/05 Robot Operator Signature PARAGON Operator Signature Comments
REQUEST RELIEF 05-MN-003 ATTACHMENT 5 PAGES 1-7
WesDyne International 4611gro.63 Reactor Vessel Weld Results Summary McGUIRE UNIT 2 WELD NO. 2RPV-W18-SE DESCRIPTION Outlet Nozzle DM Weld (B05.010.008-8A) @ 3380 2NC2F-4-1 (B05.130-013-13A)
LIMITATIONS NO D YES F COVERAGE = 83.34%
RESULTS NO. OF INDICATIONS 0 STATUS N/A EXAM DOCUMENTATION INDICATION DOCUMENTATION EX ANALYSIS LOG D-ASSESSMENT SHEET FX ACQUISITION LOG DPARAGON HARD COPY F1 SCAN PRINTOUT D-OTHER (specify)
Wx COVERAGE BREAKDOWN WESDYNE ANALYST C47 P/,-
McGuire Unit 2 DIRECTION / ORIENTATION RPV COVERAGE ESTIMATE BREAKDOWNS PARALLEL SCANS CCW/CW PERP. SCANS IN / OUT WELD WELD NO. 2RPV-W1 8-SE & 2NC2F-4-1 DESCRIPTION OUTLET NOZZLE DM WELDS @
3380 BEAM ANGLES BEAM 450 L Dual 450 L Single 450 Shear DIRECTION WELD VOLUME WELD VOLUME WELD VOLUME WELD VOLUME WELD VOLUME CCW 66.67 66.67 100 100 GW 66.67 66.67 UP 100 100 DOWN 100 100
- Circ scans limited as per procedure PDQs due to ID Counterbore and Root Combined Average = 83.34% configuration. Limitation area from 123.0" to 124.6" from 0° to 2700. ET used to supplement exam for full coverage.
ANALYSTLT
INTORNATI.."Vn.
Page j of l ANALYSIS LOG # W18-1 I Disk No: I NIA Utility: DUKE POWER Plant: I McGUIRE Unt: 2 l Outage: 12EOC16 Procedure No: PDI-ISi-254"SE Procedure Rev. No.: 2 Weld No: 2RPV-W18-SE, 2NC2F4-1 Weld Type: I DM Exam. Surface: =D Applicable Sensiltity Calibration Data Sheet No: l SE-i01 l Acquisition Log No: W18-4 PARAGON Anal. Release: 6.1.3 UT Examiner Signature: Level: 11 l Date: 03 18/05 Data File Name UT Beam Angle Ni RI RI Examiner IDI Date Channel Beam Direction Resolution I Comments I Limitations No.
Sn of IN X D 0 5 WN338-SE-PRP-DET-ON 1 70 IN X N I 03/1 8/05 D_______________
WN338-SE-PRP-DET-ON 2 70 OUT X DN 103/18/05 WN338-SE-PAR-DET-ON 1 70 CCW X _ CSW/03/18/05 WN338-SE-PAR-DET-ON 2 70 CW X CSW 03/18/05 Form 125 PD0181-254-SE, Rev. 2
N1 EVyaaNAO0 y..
Form 12.5: ET Analysis Log I NIA~
Utmy DU_ POWER Plant: McGUIRE Unit: 2 Outage: 2EOC16 Procedure No: WDI-STD-146 Procedure Rev. No.: 3 Weld No. 2RPV-WII.SE, 2NC2F4-1 Weld Type- SAFE END Appifcable Sensmtty Cal Dat Sheet No: E-1 Pon AcquisItion Log No: W1iI ET Examiner Sign Level II Date: 03M11106 Dat ET ET Probe Sean M RI RI Examiner IDI Date FiMe Name Probe Dtrection Resofilon I Comments I Li.Itations WNMS-SE.PAR4DON 4 CIRC X FSV / 0311810
_ __ _ _ _ _ _ _ _ _ _ _ I _ _ _ _ _ _ _ _ _ _ -- _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __.
.1 4 4-4-4 4-4 4-4-9 I
.9 I* *t'tt I
j -
m wnmDyfl INT§RNATA? SUynE Page I of I DATA ACQUISmON LOG # W18-1 Utility: I DUKE POWER Plant: MCGUIRE Unit: 2 Outage: 2EOC16 Procedure No: I PDI-4lS-254-SE Procedure Rev. No.: 2 Applicable Sensitivity Calibration Data Sheet No: fSE-01 UT Examiner Signature: tevel: I Date: 03/18105 Data File Name Weld-o. Index Scan Total# 'AVE' Gain Date rime Comments Start Start of Signal AdJ. V o Sweeps Amplitude (dB) &M 0
PRE-SE-PRP-DET-ON 2RPV-WIO-E 109.98 0 6 8 0 RSB 03/18/05 0318
_ __ _ _ __ _ __ _ __ __ _ _ _ _ _ _ 2N C 2F 1 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ __ _ _ _ __ _ _ _ _ _ _ _ _ _ _
PRE-SE-PRP-DET-ON 2RPV-W18-E 109.98 0 6 7 0 RSB 03/18/05 0318
_ __ _ _ _ _ _ _ _ _ ~~2NC2F-4-1 _ _ _ _ _ _ _ _ _ _ _ __ _ _
VVN338-SE-PRP-DET-ON 2RPV-W1-E 109.98 0° 372 9 0 RSB 03/18/05 0327 2NC2F-4-1__ _ _ _ _ __ _ _ _ __ _ _ _ _ __ _ _ _ _
VN338-SE-PRP-DET-ON 2RPV-W1SE 109.98 00 372 8 0 RSB 03/18/05 0327
___ ______ ___ ___ ___ 2NC2F-4 -1 _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ __ _ _ _ _
WN338-SE-PAR-DET-ON 2RPV-WIB-SE 122 00 70 8 0 DS 03/18/05 1718 2NC2F-4-1 ___ __
VN338-SE-PAR-DET-ON 2RPV-W18SE 122 00 70 9 0 DS 03/18/05 1718 2NC2FF4-1 _._________
Form 124 PD14ISI-254-SF, Rev. 2
WesDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER . .......... DUKE POWER SITE ... ........ McGUIRE UNIT #2 OUTAGE ... ........ 2EOC16 VESSEL TYPE ........... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W18-SE Weld and Scan Type = NOZZLE SAFE END PERPENDICULAR SCAN Scan Data File Name = WN338-SE-PRP-DET-ON SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION AZIMUTH DEPTH (DEGREES) (IN)
START CW 179.90 3.09.9.8 END CCW : -179.90 109.98 START CW 179.90 125.50 END CCW : -179.90 125.50 Index Size (in) = 0.24 Number of Indexes Specified = 373 Number of Indexes Completed = 373 Time Date Scan Started 03:28:13.495 03/18/05 Scan Completed 04:09:32.872 03/18/05 Robot Operator Signature Ja - m , )OY.&-DATE XA ~~DATE l-A3X-PARAGON Operator Signature ATE.JSZ Comments
WeaDyne International Reactor Vessel Inservice Examination Scan Parameter Execution CUSTOMER .... ....... DUKE POWER SITE ........... McGUIRE UNIT #2 OUTAGE ........... 2EOC16 VESSEL TYPE ...... ..... WESTINGHOUSE 4-LOOP WELD IDENTIFICATION - 2RPV-W18-SE Weld and Scan Type = NOZZLE SAFE END PARALLEL SCAN Scan Data File Name = WN338-SE-PAR-DET-ON SCAN AREA PER THE ORIGINAL TECHNIQUES UDRPS SCAN AREA DEFINITION DEPTH AZIMUTH (IN) (DEGREES)
START CW 122.00 179.90 END CCW 122.00 -179.90 START CW 127.50 179.90 END CCW 127.50 -179.90 Index Size (in) = 0.08 Number of Indexes Specified = 70 Number of Indexes Completed = 70 Time Date Scan Started 16:00:53.375 03/18/05 Scan Completed 17:18:10.654 03/18/05 Robot Operator Signature _ 2 ATE 03-PARAGON Operator Signature ATE_______