MPR Associates, Inc.

UXMPR 320 King Street Alexandria, VA 22314 CALCULATION TITLE PAGE Client:

Quad Cities I & 2 Page I of 8 Project:

Task No.

QC 2 ERV Root Cause Emergent Support 1101-0604-0009-01

Title:

Calculation No.

ASME Code Evaluation for Vibration Testing of ASBs 11-0009HDG-01 Preparer I Date Checker / Date Reviewer & Approver / Date Rev. No.

/41LW :>

L-t13-200ot Li --

200ooC H. Giesecke A. Limaye R. Coward 0

QUALITY ASSURANCE DOCUMENT This document has been prepared, checked, and reviewed/approved in accordance with the Quality Assurance requirements of 1 OCFR50 Appendix B, as specified in the MPR Quality Assurance Manual.

MPR-QA Form QA-3.1-1, Rev. 0

MPR Associates, Inc.

320 King Street Alexandria, VA 22314 RECORD OF REVISIONS Calculation No.

Prepared By Checked By Page: 2 1101-0009-HDG-01 aw muLL4aJ4 Revision Affected Pages Description 0

All Initial Issue Note:

The revision number found on each individual page of the calculation carries the revision level of the calculation in effect at the time that page was last revised.

MPR QA Form QA-3.1-2, Rev. 0

MPR Associates, Inc.

320 King Street Alexandria, VA 22314 Calculation No.

Prepared By Checked By Page: 3 1101 -0009-HDG-01

) 40-i) r Revision: 0 Table of Contents Table of Contents..................

3 1.0 Background.............................................................................................................4 2.0 Purpose 4

3.0 Summary of Results.

4......,

4.0 Analysis Approach...................

.5 5.0 References..................

7 MPR QA Form: QA-3. 1-2. Rcv. U MPR QA Form; QA-3.t-3, Rev. 0 MPR QA Form: QA-3. 1-2. Rev. 0 MPR OA Form: QA-3.1t-3, Rev. 0

MPR Associates, Inc.

kiMPiR 320 King Street Alexandria, VA 22314 Calculation No.

Prepared By Checked By Page: 4 1101-0009-HDG-01

)

Revision: 0

1.0 BACKGROUND

At the Quad Cities nuclear power plant, acoustic modes are causing the branch lines (standpipes) that run from each main steam line to the Electromatic Relief Valves (ERV) and the Safety Relief Valves (SRV) to vibrate. The level of vibration increases significantly at high power levels associated with Extended Power Uprate (EPU) operating conditions. An Acoustic Side Branch (ASB) is being installed on each standpipe in an attempt to mitigate the vibration by suppressing the acoustic mode. The ASB is a 6" diameter pipe that is either 24" long or 30" long depending on the valve, closed off by a blind flange at the free end, and would branch off the vertical standpipe to the valve. The ASB contains a steel canister that is packed with circular stainless steel screens to provide resistance to steam flow. The purpose of the ASB is to mitigate the acoustic mode that exists in the particular SRV or ERV branch line when the flow rate in the main steam line is high.

2.0 PURPOSE This purpose of this calculation is to determine the magnitude of vibration that would be considered acceptable during power operation in the plant based on the magnitude and duration of vibration testing conducted on the ASB at the Quanta Laboratories in Santa Clara, California.

The calculation method is based on the test requirements provided in Reference 1, and the test vibration levels are provided in Reference 2.

3.0

SUMMARY

OF RESULTS The acceptance criteria for vibration are based on the guidance provided in Reference I and can be summarized as follows:

  • The vibration acceleration amplitude in the axial direction of the ASB should be limited to 1.6 g RMS if it is measured on the blind flange end of the ASB or 1.5 g RMS if it is measured on the pipe end of the ASB.
  • The vibration acceleration amplitude in the transverse direction should be limited to 2.3 g RMS if measured on the pipe end of the ASB. The acceleration in the axes transverse to the ASB should be combined as the square root of the sum of the squares (SRSS) and the resultant should be less than 2.3 g RMS.
  • The ASBs can be operated at the above limits for at least an operating cycle (24 months).

Based on the fatigue calculations, there is very little difference with respect to operating 2 years and 20 years.

MPR QA Form: QA-3. 1-2. Rev. 0 MPR GA Form: QA-3.1-3. Rev. 0 MPR QA Form: OA-3. 1-2. Rev. 0 MPR CA Form: CIA-3.1-3, Rev. 0

MPR Associates, Inc.

M P

R 320 King Street -

,&I am P RAlexandria, VA 22314 Calculation No.

Prepared By Checked By Page: 5 1101-0009-HDG-Ol 01 i)

Revision: 0 4.0 ANALYSIS APPROACH The ASBs were tested on vibration tables at the Quanta Laboratories in Santa Clara, California.

Two separate test tables were used; one for vertical vibration and one for horizontal vibration.

The ASBs were mounted in a vertical orientation so the vertical table provided an axial excitation whereas the horizontal table provided a transverse excitation. Since the ASB is symmetric about its axis, only one horizontal direction was tested.

The tests in Reference 2 included separate vibration tests in the transverse direction and in the axial direction for an ASB identical to those that will be installed in the plant. The prototype that is to be installedin the plant was tested in each of these directions for a total of 80 hours9.259259e-4 days <br />0.0222 hours <br />1.322751e-4 weeks <br />3.044e-5 months <br /> (Reference 2) and the magnitude of the vibration for the screens at the point of highest vibration was 4.26 g RMS at the base of the ASB for the horizontal test and 3.0 g RMS at the flanged end of the ASB for the vertical test (Reference 2). The screen meshes inside the ASB canisters are constructed of stainless steel and testing has demonstrated that the only failure mode that could be of consequence is the wire mesh failing in fatigue. The concern is that the wire mesh fragments could become lodged in critical components in the main steam system.

Representing the fatigue curve for stainless steel from Figure 1-9.2.2, curve C (Reference 3), as Sa(N), where Sa is the allowable stress as a function of the number of stress cycles, N, a test fatigue curve is obtained as S,,,(N).

S. (N)= K5S. (N) where:

KY is a factor applied to the design fatigue to obtain the test fatigue curve and is comprised as a product of the five individual factors described below.

K3, factor for the effect of size on fatigue life K1 factor for the effect of surface finish Ks, Factor for the effect of test temperature K55 Factor for the statistical variation of test results

= 1.470-0.044 x the number of replicate tests K,C Factor for differences in design fatigue curves at various temperatures Using the actual equipment for the test, the factors K31, Ksf and Kg, are equal to unity. The screen material is either 304 or 316 stainless steel per Reference 4. Since the fatigue curves are strain controlled, the stress is directly proportional to Young's moduls. Therefore K3, is calculated as the ratio of Young's modulus for stainless steel at room temperature divided by Young's modulus MPR QA Form: QA-3. 1-2. Rev. 0 MPR QA Foffn: OA-3.1-3. Rev. 0

MPR Associates, Inc.

FA MPR 320 King Street Alexandria, VA 22314 Calculation No.

Prepared By Checked By Page: 6 1101-0009-HDG-01 l

),;

J, Revision: 0 at operating temperature or 30x 106/25x 106 or 1.2. Since only a single test is used, K55 = 1.426.

The result is:

.. 1.711 The resulting fatigue curves are shown in Figure 1, where the lower curve is the design curve from Reference 1 and the upper curve is the test curve.

According to Reference I, the minimum number of test cycles that are required to avoid fatigue within a specific number of service cycles is given by the formula:

Nrmin = 102j where:

ND are the number of service cycles required, which are assumed to be I.Ox 10".

NIm.i= 4.32x107 From the curves in Figure 1, Sal at NT is 24.82 Ksi (point C) and Sa at ND is 13.6 Ksi (point D).

Therefore, KTs will be:

K>

S., (NT) 1.825 The allowable stress for operation is the stress at which the test took place divided by K7S. Since the stress in the wire mesh is proportional to the acceleration, the acceleration will scale similarly to the stress. The stress on a particular screen will depend on the local acceleration for that screen. Therefore, the acceleration used in the analysis is the peak acceleration for the ASB. For the transverse vibration, the highest acceleration occurred on the open end of the canister and since no screen fragments were found there, no significant fatigue failures occurred during the testing. For the axial vibration, the ASB is very stiff and there is little difference in the response at the two ends. The measured value from the flange end was 3.0 g RMS whereas the measured end from the pipe end was 2.73 g RMS.

Therefore, the acceptable acceleration during operation of the plant will be as shown in Table. 1.

MPR QA Form: QA-3. 1-2. Rev. 0 MPR QA Form: QA-3.1-3, Rev. 0 MPR QA Form: QA-3. 1-2. Rev. 0 MPR OA Foffl: OA-3.1-3, Rev. 0

MPR Associates, Inc.

320 King Street

M M

^Alexandria, VA 22314 Calculation No.

Prepared By Checked By Page: 7 1101-0009-HDG-01 Revision: 0 Table 1.

Calculation of Allowable Acceleration During Plant Operation Direction Location of Test Allowable Maximum -

Acceleration KsAcceleration Acceleration W)

('s)

Transverse Pipe End 4.26 1.825 2.3 Axial Flange End 3.00 1.825 1.6 -

Axial Pipe End 2.73 1.825 1.5

5.0 REFERENCES

1. 2004 ASME Boiler and Pressure Vessel Code,Section III, Division 1 - Mandatory Appendix II-1 500, Cyclic Tests.
2. 06Q4568-DR-004, "Quad Cities Acoustic Side Branch (ASB) Vibration Test Report", Rev 2 dated April 9, 2006.
3. 2004 ASME Boiler and Pressure Vessel Code, Section 111, Division I - Mandatory Appendix I, Figure 1-9.2.2.
4. Exelon Nuclear drawing number SK-005, Sheet 1, Revision C, entitled "Fabrication Details ASB Canister 30" Effective Length Main Steam SRV Application".

MPR QA Form: QA-3 1-2. Rev. 0 MPR QA Form: QA-3.1-3. Rev. 0 MPR QA Form: QA-3. 1-2. Rev. 0 MPR QA Form: QA-3.1-3, Rev. 0

MPR Associates, Inc.

U0 M PR 320 King Street-Alexandria, VA 22314 Calculation No.

Prepared By Checked By Page: 8 1101-0009-HDG-01 44-t4 4

Revision: 0 Figure 1. Construction of Testing Parameters Ratio Diagram MPRQA Form: QA-3.I-2. Rev. 0 MPR QA Form: OA-3.1-3, Rev. 0 MPR QA Form: QA-3.1I-2, Rev. 0 MPR OA Form: 0A-3."4, Rev.0 Request 9(b) - GENE 0000-0053-2954, Revision 1

GENE 0000-0053-2954, Revision 1 DRF 0000-0053-2950 Request for Additional Information: Quad Cities Unit 2 Dryer Inspection. Start-uD and Power Ascension Plan RAI 9 (b): For the large dryer crack in the skirt base metal at 135-degree location, provide the following information and documentation supporting your responses.

(b) What may be the corresponding reduction in the fatigue stress limits?

Response: As discussed in earlier documents, the 135-140 degree location was subjected to significant deformation during the steam dryer's installation in 2005.

Finite element analysis using a solid model was able to show that the cutout location was plastically deformed at least to -4% strain levels equivalent to -60 ksi or higher stress when actual nominal L-grade stainless steel properties were used in the analysis (Reference 1)1. This permanently strained material would be the equivalent to highly strained material with a corresponding high residual mean stress.

These stress levels exceed the mean stress level that was considered in developing the high cycle regime fatigue Curve C of the ASME Code. The higher mean stress level is expected to translate into lower level of cyclic stress amplitude needed to produce crack initiation.

The classic understanding regarding the effect of mean stress on the stress amplitude that will lead to fatigue cracking has led to the use of different formulations to calculate effect.

Goodman, Soderberg and others have developed these relationships, all of which predict a reduction in the allowable alternating stress amplitude with increasing tensile mean stress (Reference 2).

For the steam dryer, a design value of 13600 psi was used for non-critical locations based on the most conservative ASME Code Curve C. The Code established this curve based on a nominal level of mean stress that may be present from sources such as the weld residual or fit up. The Curve C of the ASME Code used a mean stress of 44 ksi (at room temperature), based on a cyclic stress-strain curve for stainless steel. This calculation is described in the technical basis paper by Manjoine and Tome (Reference 3) that was used by the ASME Code in developing/extending the stainless steel fatigue curves into the very high cycle range (up to 1011 cycles). This design curve was derived by applying a factor of 2 reduction to the average fatigue initiation stress determined from laboratory data.

However, given the higher plastic strain and complementary increase in strength of the deformed base ring location, the expected fatigue endurance properties would be significantly reduced due to mean stress effects. This effect can be calculated directly from the equations used by Manjoine, et al. Although the region of interest was cold worked by the installation event, the evaluation of the mean stress effect was performed based on the fatigue properties of annealed I The higher range of the properties seem to be applicable to the base ring material which had a room temperature yield strength > 40 ksi, a value well above the typical L-grade stainless steel value.

1

GENE 0000-0053-2954, Revision 1 DRF 0000-0053-2950 material. Therefore, the evaluation should be viewed in qualitative rather than quantitative terms. For conservatism, the loading was considered as stress controlled in the determination of the mean stress effect, i.e. the range of Pi + Pb

+Q was assumed to exceed 27.2 ksi. The impact of an assumed residual (mean) stress of 60 ksi would be a 30% reduction in the allowable while the assumption of a 70 ksi yield strength to represent the local mean stress would reduce the allowable by 50%. These levels of reduction in fatigue properties are very likely given the deformation and the constraint imposed by the several intersecting welds present at the base ring cut out corner-solid gusset-skirt region where crack initiation occurred.

In summary, the plastic deformation would be expected to lead to a high residual mean stress. Consistent with the understanding of fatigue behavior in the presence of high mean stresses, the fatigue endurance limit would be reduced.

Based on the conservative evaluation, the reduction in endurance limit would be expected to be a maximum of 50%.

References:

1. GENE 0000-0053-2910,"Quad Cities Units 2 Replacement Steam Dryer Analysis Detailed Stress Analysis of Skirt Base Plate Cutout and Gussets," April 2006.
2. Comparison of the ASME Approach for Determining the Influence of Mean Stress, With Data Obtained in High Temperature Water H.D. Solomon, R.E. DeLair and E. Tolksdorf, 2000CRD064, July 2000.
3. Manjoine, M.J. and Tome, R.E., "Proposed Design Criteria for High Cycle Fatigue of Austenitic Stainless Steels," International Conference on Advances in Life Prediction Methods, ASME, 1983, pp. 51-57.

2