ML061440435

From kanterella
Jump to navigation Jump to search
Technical Specifications, Reactivity Control Systems Minimum Temperature for Criticality
ML061440435
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 05/24/2006
From:
Office of Nuclear Reactor Regulation
To:
References
Download: ML061440435 (1)


Text

REACTIVITY CONTROL SYSTEMS MINIMUM TEMPERATURE FOR CRITICALITY LIMITING CONDITION FOR OPERATION 3.1.1.5 The Reactor Coolant System lowest operating loop temperature (Tavg) shall be

> 5400 F.

APPLICABILITY: MODES 1 and 2#*.

ACTION:

With a Reactor Coolant System operating loop temperature (Tavg) < 5400 F, restore Tavg to within I its limit within 15 minutes or be in HOT STANDBY within the next 15 minutes.

SURVEILLANCE REQUIREMENTS 4.1.1.5 The Reactor Coolant System temperature (Tavg) shall be determined to be: > 540°F at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

I

  1. With Kef > 1.0.
  • See Special Test Exception 3.10.5.

ARKANSAS - UNIT 2 3/4 1-6 Amendment No. 229, Next page is 3/4 1-17