ML061440435

From kanterella
Jump to navigation Jump to search
Technical Specifications, Reactivity Control Systems Minimum Temperature for Criticality
ML061440435
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 05/24/2006
From:
Office of Nuclear Reactor Regulation
To:
References
Download: ML061440435 (1)


Text

REACTIVITY CONTROL SYSTEMS MINIMUM TEMPERATURE FOR CRITICALITY LIMITING CONDITION FOR OPERATION 3.1.1.5 The Reactor Coolant System lowest operating loop temperature (Tavg) shall be

> 5400F.

APPLICABILITY:

MODES 1 and 2#*.

ACTION:

With a Reactor Coolant System operating loop temperature (Tavg) < 5400F, restore Tavg to within its limit within 15 minutes or be in HOT STANDBY within the next 15 minutes.

SURVEILLANCE REQUIREMENTS 4.1.1.5 The Reactor Coolant System temperature (Tavg) shall be determined to be: > 540°F at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

I I

  1. With Kef > 1.0.
  • See Special Test Exception 3.10.5.

ARKANSAS - UNIT 2 3/4 1-6 Next page is 3/4 1-17 Amendment No. 229,