PILGRIM NUCLEAR POWER STATION Facility Operating License DPR-35 Radiological Effluent and Waste Disposal Report January 1 through December 31, 2004 tel rgy'

3.0 METEOROLOGICAL DATA Meteorological data are summarized for the reporting period in Appendix A, in the standard joint frequency distribution format as given in NRC Regulatory Guide 1.21.

The predominant meteorological conditions observed during the annual reporting period can be summarized with their corresponding frequencies as follows:

Stability Class:

Class D, 42%

Wind Direction (from):

South-southwest, 14%

33-ft Wind Speed:

4-7 mph, 53%

220-ft Wind Speed:

13-18 mph, 36%

There were a number of instances when data collection from the 220-ft meteorological tower was not continuous. During the course of 2004, numerous problems were encountered with meteorological sensors and translator card electronics. Data recovery for the entire annual period was about 76%

for the 33-ft level, and 81% for the 220-ft level of the tower. These data recovery values are well below the NRC's recommended annual recovery goal of 90%. Steps have been taken to perform backups of the database computer, as well as performing qualitative data screening on a weekly basis to identify malfunctioning sensors and facilitate more timely repairs. A detailed engineering design plan is being implemented to upgrade meteorological instrumentation to increase reliability and data recovery.

19

APPENDIX A Meteorological Joint Frequency Distributions TABLE TABLE TITLE PAGE A-1 Joint Frequency Distribution of Wind Directions and Speeds for the 48 33-ft Level of the 220-ft Tower A-2 Joint Frequency Distribution of Wind Directions and Speeds for the 58 220-ft Level of the 220-ft Tower 47

I Table A-i Joint Frequency Distribution of Wind Directions and Speeds For the 33-ft level of the 220-ft Tower Jan-Mar 2004 Class A Freq:

0.139 mph I N JNNE NE[ENEJE ESEJ SE ]SSE[I S I~

SSW[I SW IWSWI W IWNWI NW JNNW TOTAL.

Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 1

0 0

0 0

0 0

0 0

0 0

2 0

0 0

1 4

3.5-7.5 11 11 8

0 4

1 0

2 0

0 2

8 3

10 10 18 88 7.5-12.5 3

21 29 8

2 1

0 0

5 10 11 3

17 20 8

6 144 12.5-18.5, 0 6

1 0

0 0

0 0

5 3

0 0

3 4

1 0

2 18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL 38i a 138 f8 e 2

0 2 110 213 13113123 34~

191251259 Class B Freq: 0.048 mph1L1SSWSW W IWNWI NW NNW TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

3.5-7.5 2

2 3

0 0

0 1

0 1

0 2

5 1

2 4

0 23 7.5-12.5 0

5 8

4 1

0 1

0 7

8 4

4 15 2

3 0

62 12.5-18.5. 0 2

0 2

0 0

0 0

0 0

1 I

0 0

0 0

0 5

18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL 1 2 9 1116 11 0 210181 9[

L16 4~. 7....1..L.

0..2..

90..

Class C Freq: 0.076 mph I N NNE I1NE EN SE S

S SSWj SW IWSW IW IWNWI NW JNNW[ TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 1

2 1

0 0

0 0

0 0

1 0

0 1

0 6

3.5-7.5 1

3 1

5 2

1 2

0 7

2 6

4 10 12 3

2 61 7.5-12.5 1

2 10 9

2 0

1 3

12 6

1 1

16 5

0 0

69 12.5-18.5.

0 4

0 0

0 0

0 0

0 0

1 0

0 1

0 0

6 18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL 1 2191121161(11313 19 8J8 16126] 1814 J2 142 Class D Freq: 0.570 mph N JNNEJ NE I ENEjE IESE]I SE [SSEJ S ISSWjI SW ]WSW[ W JWNWI NW_ NNWITOTAL.

Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

1 1

1 4

1 4

4 9

2 6

10 1

5 0

3 52 3.5-7.5 12 14 12 20 17 24 22 9

17 31 46 86 82 52 44 12 500 7.5-12.5 9

18 2

0 6

6 1

1 20 25 29 61 210 78 20 0 1486 12.5-18.5 0

4 0

0 0

0 0

0 0

0 0

0 15 8

0 0

27 18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0,

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL J21 37J15 21[27 31 127J 14146 581811157 3081143164Ji

[os 48

Table A-i (continued)

Jan-Mar 2004 Class E Freq:

0.153 mph N

N EEEEE

[SE JSSE S SSWISWJ WSW wI WNW NW NNWf TOTAL Calm-0.95 0

0 0

0 0

0 0

0.

0 0

0 0

0

-0 0

0 0

0.95-3.5 0

0 0

2 5

2 6

11 9

3 7,

9 7

5 2

1 69 3.5-7.5 0

1 0

13 1

0 2

6 9

16 32 33 44 23 3

2 185 7.5-12.5 2

0 0

0 0

0 0

0 2

1 5

5 7

4 4

2 32 12.5-18.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL 2

1171201 201441 2

47 1581 32 ~9 51 286 Class F Freq:

0.014 mph N

NN EEEEEES SSEISISSWISWw WS N

W NW TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

0 1

0 0

0 0

1 2

1 0

0 0

0 5

3.5-7.5 0

0 0

1 0

0 0

0 0

3 11 1

2 0

0 0

18 7.5-12.5 0

0 0

0 0

0 0

0 0

1 2

0 0

0 0

0 3

12.5-18.5

.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL 1

ojfj 0 Jo 0 10 5 11512 2101010 26 Class G Freq:

0.000 mph

[NJNNEJINEENEJE]IESEISEISSE[

S SSW SW w WS N

WINW TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

3.5-7.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

7.5-12.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

12.5-18.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0I 0

0 18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL 0

0 0

.i.

0 0 0 0

0 0

0 Class All Freq:

1.000 mph IN NNE INEJENE E IESE SEJISSEJI S jSSWlSWl WS N

WINW TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 1

1 2

5 11 31015 18 6

15 23 8

10 3

5 136 3.5-7.5 26 31 24 3924 2627 1734 5299 137142 99 64 34 875 7.5-12.5 15 48 49 21 11 7

3 4

48 51 52 74 265 109 35 8

796 12.5-18.5 0

16 1

2 0

0 0

0 5

3 2

0 18 13 1

0 61 18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 00 0

0 0

0 0

0 0

0 0

0 0

TOA 42[94 17611 671 640 136 11031 11211168T23 43121103 7

1868 _

49

Table A-I (continued)

Apr-Jun 2004 Class A Freq: 0.173 mph I N IjNNEj NE LENE ~1 SE SE jSSEj S JSSWj SW JWSWJ W I WNWj NW JNNW TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

0 0

0 0

0 0

0 0

0 0

1 0

2 3

3.6-7.5 33 22 22 6

5 6

4 2

3 3

3 4

2 3

1 1 1

6 145 7.5-12.5 1 0 3

1 0 4

4 2

1 3

28 51 6

2 6

24 3

0 157 12.5-18.5 0

0 0

0 0

0 0

0 4

1 3 0

0 0

0 0

0 1 7 18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

OALJ43J25 J 32 [ ioj35 67 j

~

8~2 14 j18 322 Class B Freq: 0.057 mph N1 N E

N IEES1SE S SW.S S

w NNW1 T1~

I OTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 3

0 0

0 0

3 0

1 1

0 0

0 0

0 0

2 10 3.5-7.5 1

5 8

3 3

5 4

5 4

8 4

0 0

2 2

3 57 7.5-12.5 1

0 0

0 1

1 1

0 9

14 2

0 0

7 0

0 36 12.5-18.5. 0 0

0 0

0 0

0 0

1 1

0 0

0 0

0 0

2 18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

6TOTAL 31 4 9

J6 23161010 912 LLI105 Class C Freq:

0.078 Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

I0 I0 0

0 0

0 0.95-3.5 3

3 0

2 2

2 2

7 3

0 0

0 1

1 4

2 32 3.5-7.5 6

3 3

2 10 3

3 7

13 6

7 2

2 2

6 1

76 7.5-12.5 0

0 0

0 0

0 0

0 3

21 2

0 3

2 0

0 31 12.5-18.5 0

0 0

0 0

0 0

0 3

3 0

0 0

0 0

0 6

18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOA 9 6 J3 4 J12 5

.5j 1412213019 12 1 6 5 110 3[145 Class D Freq: 0.300 ESE S

SSE I YSW SW IWSW-mph N

NNEWSWIWWNWINW NNWITOTAL Calm-0.951 0

0 I0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.95-3.5 7

5 9

7 6

5 14 9

4 1

1 9

6 9

8 4

103 3.6-7.5 3

8 9

10 30 16 16 13 30 61 22 27 19 6

12 3

285 7.5-12.5 3

1 0

0 0

1 0

0 18 84 16 3

9 17 4

5 161 12.5-18.5 0

0 0

0 0

0 0

0 2

6 0

0 0

0 0

0 8

18.5-24 0

0 0

0 0

0

-0 10 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL[ 13114118117 [ 35( 22[30( 22 154152 J39 [39

_34 132124(2 50

Table A-i (continued)

Apr-Jun 2004 Class E Freq:

0.276 mph ININNEI NE JENE1 EESE SE j~SSEj S I~ SSW I SW IWSWI W IWNWI NW INNWITOTAL Calm-0.95 0

0 0

1 0

0 0

0 0

0 0

0 0

0 0

0 1

0.95-3.5 5

3 5

9 5

6 6

13 6

5 8

10 9

14 6

7 1117 3.5-7.5 10 4

8 30 33 13 3

3 21 31 43 54 135 10 13 5

316 7.5-12.5 3

1 0

0 1

0 0

0 3

37 15 6

6 1

3 2

78 12.5-18.5 0

0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 1

18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL 118 [8 113140 139119 91161301 74 16617 1 0 25122 14 1513 Class F Freq: 0.093 Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 1

0 1

0 2

1 1

3 9

7 6

4 1

0 36 3.5-7.5 1

1 1

a 1

0 0

0 0

17 47 9

4 4

5 1

99 7.5-12.5 0

0 0

0 0

0 0

0 0

10 27 0

0 0

0 0

37 12.5-18.5 0

0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 1

18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL [T 1

2-8Lz2..0 i2.1Z1 31 83 1161101816 LI173 Class G Freq: 0.023 mph N

N E EEIE EE S SE SISWIS WW N

NW (NNW TOTL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

0 0

0 0

0 1

2 5

3 0

0 0

0 11 3.5-7.5 0

0 0

0 0

0 0

0 0

2 17 4

1 0

0 0

24 7.5-12.5 0

0 0

0 0

0 0

0 0

2 5

0 0

0 0

0 7

12.5-18.5 0

0 0

0 0

0 0

0-0 0

0 0

0 0

0 0

0 18.5-24 0

0 0

0 0

0 0

0 10 10 0 I0 I0 0 0 I

0 0

24 0 00 0

0 0

0 0

0 0

0 0

0 0

0 0

0 TOTAL [OIO1O1OI0 0101 o0 1 6 12717 (11010

[4 Class All Freq: 1.000 Calm-0.95 0

0 0

1 0

0 0

0 0

0 0

0 0

0 0

0 1

0.95-3.5 18 11 15 18 13 16 24 31 16 11 23 29 22 29 19 17 312 3.5-7.5 54 43 51 59 82 43 30 30 71 128 143 100 63 27 49 29 1002 7.6-12.5 17 5

10 4

6 4

2 3

61 219 73 11 24 51 10 7

507 12.5-18.5 0

0 0

0 0

0 0

0 10 25 0

0 0

0 0

0 35 F18.5-24 0

0 0

0 0

0 0

0 0

0 00 01 ~0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL j89 L59176 182 101i 63156164 158 3831239 140 1091107178 153 11857 51

Table A-i (continued)

Jul-Sep 2004 Class A Freq:

0.173 mph N JNNEJN EN~~E E IES SE SS S~~

SS SW WS WsW WW N wNNW T~I OTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 2

4 0

1 0

1 1

0 1

0 0 I0 0

1 0

2 13 3.5-7.5 13 17 7

6 4

4 0

5 17 27 11 3

2 2

3 12 133 7.5-12.5 5

5 0

0 0

0 0

0 18 24 3

0 0

0 0

3 58 12.5-18.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TTLL20 26 7

7 4~.5 11 5 361 51 14 j3 2 1 3 3..I...2+/-

Class S Freq:

0.062 Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

1 1

0 1

0 0

0 2

2 0

0 1

0 2

2 12 3.5-7.5 1

2 1

3 3

0 0

2 13 9

2 1

0 3

3 4

47 7.6-12.5 0

0 0

0 0

0 0

0 8

4 1

0 0

0 0

1 14 12.5-18.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

18.5-24 0

0 0

0 0

0_ 0 0

0 0

0 0

0 0

0 0

0

>24 0o 0

0 0

0 0

0 0

0 0

0 0

0 0

0 TOA ~

J HI10 0223 15131 I 1 J3f57 73 Class C Freq: 0.091 Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 1

1 0

0 0

0 1

0 0

3 1

0 2

1 2

0 12 3.5-7.5 2

3 3

4 2

2 0

5 21 26 6

1 0

1 3

1 80 7.5-12.5 0

0 0

0 0

1 0

0 9

4 1

0 0

0 0

1 16 12.5-18.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

18.55-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TTL 11 12 3Jj530 1 33 18 1~ 1 2 1215 2j~

Class D Freq: 0.297 Calm-0.95 0

0 0

0 0

0 0

1 0

0 0

0 0

0 1

0 2

0.95-3.5 6

2 9

2 7

5 9

6 10 5

2 5

4 2

4 2

80 3.5-7.5 7

3 6

1 1 7

16 7

9 56 42 19 17 5

6 4

5 220 7.5-12.5 3

1 0

0 0

1 0

0 10 28 6

0 0

0 0

0 49 12.5-18.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

18-.2-24

-0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTL 1616 115113 J14J22[16 16176175127122191819 J7 351 52

Table A-i (continued)

Jul-Sep 2004 Class E Freq:

0.275 mph N

NE NEJENE EJESEI SE jSSE S [SSW SW WSW W jWNWJ NW NNW TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 1

0 0

1 0

0 2

0.95-3.5 1

2 6

8 1

4 10 23 10 5

9 13 15 10 7

4 128 3.5-7.5 2

1 2

8 7

1 0

5 29 31 16 24 29 14 2

1 172 7.5-12.5 0

0 0

0 0

0 0

0 0

16 7

0 0

0 0

0 23 12.5-18.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

18.55-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOA 31 j8 16j8J 5[ 10 28139152133 37 4 12519 5~

325 Class F Freq: 0.089 Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

1 0

2 4

0 1

2 5

3 12 12 1

3 2

1 49 3.5-7.5 0

0 0

4 1

0 0

1 4

8 21 3

1 1

1 0

45 7.5-12.5 0

0 0

0 0

0 0

0 0

4 7

0 0

0 0

0 1 1 12.5-18.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

18.5-24 0

0 0

0 0

0 0

0 0 10 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOA j

~0 6

5j0ji 3

9~ 1514011512 4

3 ijo Class G Freq:

0.013-mph N

N E EE E

EE S7SE S

SW S S

NIN N

OA Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

1 0

0 0

0 0

0 0

0 4

1 0

0 0

0 6

3.15-7.5 0

0 0

0 0

0 0

0 0

0 8

0 0

0 0

0 8

7.5-12.5 0

0 0

0 0

0 0

0 0

0 1

0 0

0 0

0 1

12.5-18.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 00 0

0 0

0 0

TOTAL Ti T

IT i

0 13 1

0 TT0 15 Class All Freq:

1.000 NEINE EW NWTOA mph j~N INNlNE IE E ESEI SEj SE S ISSW SW jWSWj W IWNWI WINIO Calm-0.95 0

0 0

0 0

0 0

1 0

0 1

0 0

1 1

0 4

0.95-3.5 10 12 16 13 13 10 22 31 28 18 28 31 23 17 17 11 300 3.5-7.5 25 26 19 36 24 23 7

27 140 143 83 49 37 27 16 23 705 7.5-12.5 8

6 0

0 0

2 0

0 45 80 26 0

0 0

0 5

172 12.5-18.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL[43 44 35

_9 3

35129159 1213 124111381 8016 45J34 13911181 53

Table A-i (continued)

Oct-Dec 2004 Class A Freq:

0.070__

mph JN NNEI NE JENE E ESEl SE SSEI S [SSWI SW jWSWJ W IWNWI NWIN TO L

Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 2

2 4

3.5-7.5 9

3 0

0 0

0 0

0 1

2 2

0 0

9 5

9 40 7.5-12.5 6

19 3

7 10 2

0 0

4 1

0 1

0 5

12 6

76 12.5-18.5 2 0

0 3

2 0

0 0

0 0

0 0

0 0

0 0

7 18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL 1 17r22 3

1T 1 2=

3 2T 1 10114119 17L1 Class S Freq: 0.026 mph I NI NE N NE E EE S SI S IS WW W LLIWNWI NW NNW TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 11 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 3.5-7.5 2

3 1

0 0

0 0

0 1

0 1

1 1

1 2

1 14 7.5-12.5 2

10 2

0 0

0 0

0 3

4 1

0 1

3 1

1 28 12.5-18.5 1

1 0

0 0

0 0

0 1

0 0

0 0

0 0

0 3

18.5-24 0

0 1

0 0

0 0

0 0

0 0

0 0

0 0

0 1

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

T AL6j114 14IO0 10 O

010151412 1

3 2

4 Class C Freq: 0.050 mph I N I NNE I NE I 1 ENE I 1IESE I SE I SSEI S ISSW I SW IWSWI W IWNWI NW jNNW TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 2

0 0

1 1

0 0

0 0

0 0

0 1

2 0

0 7

3.5-7.5 5

4 2

1 1

2 4

0 0

0 2

0 5

3 2

1 3

7.5-12.5 0

16 4

0 0

0 3

1 2

4 6

3 3

3 2

0 47 12.5-18.5.

1 0

0 0

0 0

0 1

0 1

0 0

0 0

0 0

3 1852I 0

0 0

0 8>)24 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL S8120161312121712121518 3 9~ 1-814 9

Class D Freq: 0.473 mph N

NElI NE I ENEI ELIESE ISE I SSE I SI SSW ISW IWSWI W IWNWI NW INNW ITOTAL Calm-0.951 0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.95-3.5 4

4 2

2 1

2 8

10 9

4 5

4 5

3 2

6 71 3.5-7.5 29 19 34 9

7 14 17 19 37 40 40 51 36 18 26 17 413 7.5-12.5 6

48 26 4

5 18 14 6

12 28 22 19 48 38 31 11 336 12.5-18.5 7

0 0

4 0

2 0

6 3

0 0

1 10 0

0 0

33 18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTALI46 171 j62 19 13 3 9 4 1 1611 72[67 75 995 j34j 85 54

Table A-i (continued)

Oct-Dec 2004 Class E Freq:

0.315 mph N INNE NE ENE E ESE SE SSE S SSW SW WSWI W WNWI NW JNNW TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 5

0 3

4 0

2 7

9 18 13 12 17 14 12 11 4

131 3.5-7.5 14 5

0 3

8 2

7 23 55 62 52 54 32 21 28 13 379 7.5-12.

3 0

0 0

0 0

0 8

8 12 9

3 4

8 0

1 58 12.5-18.5 1

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 1

18.5-24 0 101 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOA5 3 53 7 8[ '411414018118717 74 501411391 J[567 Class F Freq: 0.063 mph I N NNEINE IENEIEI ESEJ SE I S SW S WSW W WNWI NWNNW TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

1 0

0 1

0 0

6 2

0 4

8 9

1 0

0 32 3.5-7.5 0

0 0

1 0

0 0

0 5

16 39 6

3 2

0 1

73 7.5-12.5 0

0 0

0 0

0 0

0 0

8 1

0 0

0 0

0 9

12.5-18.5.

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL 0

1 0 1 i 0101 6 7

24 44114112 01 1

14 Class G Freq: 0.002 mph N1 NNEI1 NE EE E EEIS S

S WIS N NW NN_

TTA Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 1

3.5-7.5 0

0 0

0 0

0 0

0 0

1 1

0 0

0 0

0 2

7.5-12.5 0

0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 1

12.5-18.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0 I

T I

T I0 3

10 0 F Class All Freq:

1.000 Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 I0 0

0 0.95-3.5 12 5

5 7

3 4

15 25 29 18 21 29 29 18 15 12 247 3.5-7.5 59 34 37 14 16 18 28 42 99 121 137 112 77 54 63 42 953 7.5-12.5 17 93 35 11 15 20 17 15 29 58 39 26 56 57 46 19 553 12.5-18.5 12 1

0 7

2 2

0 7

4 1

0 1

10 0

0 0

47 18.5-24 0

0 1

1I 0

0 0

0 0

0 0

0 10 2

24 0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 TOTAL I1001 133 178140 j36 44j 60189 1161 11981197 11681172 1129 11241731802 55

Table A-I (continued)

Jan-Dec 2004 Class A Freq:

0.136 mph N INNE NE] ENE SE] SE [SSE T[SW SW jWSW w IWNW N N W ~TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 3

4 0

1 0

1 1

0 1

0 0

2 0

2 2

7 24 3.5-7.5 66 53 37 12 13 11 4

9 21 32 18 15 7

24 29 55 406 7.5-12.5 24 48 42 19 16 5

1 3

55 86 20 6

23 49 23 15 435 12.5-18.5 2

6 1

3 2

0 0

0 9

16 0

0 3

4 1

0 47 18.5-24 0-0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TTL 11 0]35 [1 17 61121861134138123133 17 92 Class B Freq: 0.047 mph JN INNEI NE ~ENE ~EESE SE JSSE] S JSSWjI SW JWSWj W tWNWIN N W ~TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 4

1 1

0 1

3 0

1 3

2 0

0 1

0 2

4 23 3.5-7.5 6

12 13 6

6 5

5 7

19 17 9

7 2

8 11 8

141 7.5-12.5 3

15 10 4

2 1

2 0

27 30 8

4 16 12 4

2 140 12.5-18.5.

1 3

0 2

0 0

0 0

2 I

I 0

0 0

0 0

10 18.5-24 0

0 1

0 0

0 0

0 0

0 0

0 0

0 0

0 1

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL 111125 12jj 11851 Oijlj9 2017435 Class C Freq:

0.072 mph I N INNEI NE I ENEJE ESE [ SE JSSEI S ISSWI SW ]WSWI W IWNW NW[NNWJTOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 6

4 1

5 4

2 3

7 3

3 1

1 4

4 7

2 57 3.5-7.5 14 13 9

12 15 8

9 12 41 34 21 7

17 18 14 5

249 7.5-12.5 1

18 14 9

2 1

4 4

26 35 10 4

22 10 2

1 163 12.5-18.5.

1 4

0 0

0 0

0 1

3 4

1 0

0 1

0 0

15 18.5-24 0

0 0

1 0

0 0

0 0

0 0

0 0

0 0

0 1

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL 22 39 24 27J21j 11 16 24 73 76 33 12 43 33 23 8 1485 Class D Freq:

0.421 mph JNJNNE NE ENE[E IESE SEJ SSEj SsSW SW JWSW w JWNW] NW INNWITOTAL Calm-0.95 0

0 0

0 0

0 0

1 0

0 0

0 0

0 1

0 2

0.95-3.5 17 12 21 12 17 13 35 29 32 12 14 28 16 19 14 15 306 3.5-7.5 51 44 61 50 61 70 62 50 140 174 127 181 142 82 86 37 1418 7.5-12.5 21 68 28 4

11 26 15 7

60 165 73 83 267 133 55 16 1032 12.5-18.5 7

4 0

4 0

2 0

6 5

6 0

1 25 8

0 0

68 18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 I0 0

0 0

0

>24 0

0 0

0 0

0 0

0 0

0 0 0 0

0 0

0 0

TOA 961181070 ]89[ 1 112931237 1357121412931451 2421156 6812826 56

Table A-i (continued)

Jan-Dec 2004 Class E Freq:

0.252 mph ININNEINEJENEIEJESEIS SEISSSEWI TSSWIWSWIWIWNWNW NWNNWI TOTAL Calm-0.95 0

0 0

1 0

0 0

0 0

0 1

0 0

1 0

0 3

0.95-3.5 11 5

14 23 11 14 29 56 43 26 36 49 45 41 26 16 445 3.5-7.5 28 11 10 54 49 16 12 37 114 140 143 165 140 68 48 21 1052 7.5-12.5 8

1 0

0 1

0 0

8 13 66 36 14 17 13 7

5 189 12.5-18.5 1

0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 2

18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TTL 4 117 1241 8

301 1

1 41 101 11701 233 12161 28101 1231 79 1421 1691 Class F Freq:

0.062 mph ININNE]NE]ENEJE]

ESEJSE SSE[

SS SWSW SWWWSWIWIWNWINW1NNWI TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

2 1

2 7

0 3

9 8

7 27 28 16 8

3 1

122 3.5-7.5 1

1 1

14 2

0 0

1 9

44 118 19 10 7

6 2

235 7.5-12.5 0

0 0

0 0

0 0

0 0

23 37 0

0 0

0 0

60 12.5-18.5 0

0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 1

18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL 117 75 1821 4182 Class G Freq:

0.009 mph JN NNE JNEJENE]EJESE SEJSSEI SISSW SWIWSWIW WNW INWI NNWJ TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

1 0

0 0

0 0

0 1

3 9

4 0

0 0

0 18 3.5-7.5 0

0 0

0 0

0 0

0 0

3 26 4

1 0

0 0

34 7.5-12.5 0

0 0

0 0

0 0

0 0

3 6

0 0

0 0

0 9

12.5-18.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL 0

i1o0o0o0ojo0o0i1j9 41 8111116 Class All Freq:

1.000 mph jN NNJEEEEEESISIS SSWISWIWSWIWIWNWINWJNNWI TOTAL Calm-0.95 0

0 0

1 0

0 0

1 0

0 1

0 0

1 1

0 5

0.95-3.5 41 29 38 43 40 33 71 102 91 53 87 112 82 74 54 45 995 3.5-7.5 164 134 131 148 148 110 92 116 344 444 462 398 319 207 192 128 3535 7.5-12.5 57 150 94 36 32 33 22 22 181 408 190 111 345 217 91 39 2028 12.5-18.5 12 17 1

9 2

2 0

7 19 29 2

1 28 13 1

0 143 18.5-24 0

0 1

1 0

0 0

0 0

0 0

0 0

0 0

0 2

>24 0

0

,0 I01 01 0 0

0 00 0

0 0

0 0

0 0

TOTAL 12741 330 1 265 1238 1220 1178 11851 248 j635 1 934 17421 622 1 71512 1339121160 57

Table A-2 Joint Frequency Distribution of Wind Directions and Speeds For the 220-ft level of the 220-ft Tower Jan-Mar 2004 Class A Freq: 0.137 mph N NNE NE ENE I E ESE SE SSE S SSW ISW jWSWJ W JWNW[ NW NNW TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

0 0

0 0

0 0

0 0 0 0

0 0

0 0

3.5-7.5 1

0 2

0 0

0 0

0 0

0 0

0 0

0 0

1 4

7.5-12.5 2

5 8

0 0

0 0

1 0

0 1

0 1

2 4

3 27 12.5-18.5 6

4 22 2

4 1

1 1

2 2

6 8

9 9

9 7

93 18.5-24 0

1 16 6

2 0

0 0

1 9

7 1

7 15 6

6 77

>24 3

9 5

0 0

0 0 0 0

5 0

0 6

12 4

6 50 TOTAL I12 119 [53 8 16J 111 1 21 3 116 1141 9 123 138 231231251 Class B Freq: 0.048 mph N lNNE[ NE lENEI E IESEl SE [SSEl S lSSWl SW IWSWl W WNWlN WW lN TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

3.5-7.5 1

1 1

0 0

0 0

0 0

0 0

0 0

0 1

0 4

7.5-12.5 0

0 1

1 0

0 0

0 1

0 0

1 0

1 0

0 5

12.5-18.51 1

0 2

1 0

0 0

1 2

3 6

2 6

0 0

1 25 18.5-24 0

0 9

3 1

0 1

0 0

8 1

2 9

3 4

0 41

>24 1

1 1

30 0

1 1

3 1

1 0

13 TOTAL [312 114 1 8 1 11 0 1 1 31 11 8 1

88 Class C Freq: 0.076 mph [ N NNEl NE lEN E lESEl SE SSEl S I SSWl SW IWSWl W WNWINWW lN TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

3.5-7.5 0

0 2

0 3

0 0

0 0

0 1

0 0

0 1

0 7

7.5-12.5 0

1 1

0 2

0 1

0 1

2 4

2 1

2 2

0 19 12.5-18.5 3

0 5

2 3

0 1

3 11 7

0 1

14 6

1 2

59 18.5-24 0

0 4

6 3

0 0

1 1

4 2

0 8

6 0

0 35

>24 1

5 0

2 1

0 1

0 0

1 1

0 4

3 0

0 19 TOTAL 4 L 6 121 1011 0

3 4 113 1141 8 1 3 127 1 17 1 4 2 139 Class D Freq:

0.571 mph N lNNE NE lENE E ESEI SE I SSE S I SSWlI SW JWSWl W 1WNWI NW NNWlTOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 1

0 0

1 0

0 0

0 0

0 1

2 0

0 5

3.5-7.5 1

4 4

3 2

3 5

4 0

1 3

3 2

2 2

4 43 7.5-12.5 2

4 9

10 18 11 17 5

12 8

11 26 16 15 8

2 174 12.5-18.5 13 6

3 1

2 14 8

6 9

35 55 46 67 35 31 6

339 18.5-24 8

2 0

0 5

3 2

0 1

16 31 47 108 64 27 6

320

>24 14 4

0 0

2 0

0 0

0 1

0 2

81 60 2

0 166 TOTAL 38Sl 20 7 l 4 T2 9 l 3 2 l 32 15 22 61 1001 124 275 178 70 [ 20 10471 58

Table A-2 (continued)

Jan-Mar 2004 Class E Freq:

0.154 mph ININNE N ENE S S S JS SSW SW WSW WI WNW INWINNWITOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 1

0 0

1 0

0 0

0 1

0 1

0 0

1 0

0 5

3.5-7.5 0

0 1

4 2

6 5

2 2

2 0

0 4

6 3

2 39 7.5-12.5 0

0 0

3 862 3 10 5 2

3 7

9 17 19 0

78 12.5-18.5 0

0 0

0 0

0 3

4 3

8

,15 22

,16 29 9

0 109 18.5-24 0

1 0

0 0

0 0

0 2

1 6

5 5

7 7

0 34

>24 2

0 0

0 0

0 0

00 00 0

1 6

6 2

17 TOTAL J3 f 1 181101 8Il11 131 25 4

6 34J 4j282 Class F Freq:

0.014 mph jN NNE INE ENE E ESE ISET SSEISISSW [SWI WSW (W WNW INWI NNW TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

3.5-7.5 0

0 0

0 1

0 0

0 1

0 0

0 2

0 0

0 4

7.5-12.5 0

0 0

0 0

0 0

1 1

1 1

2 1

3 0

0 10 12.5-18.5 0

0 0

0 0

0 0

0 0

0 9

1 0

2 0

0 12 18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

000 0

00 0

0 0

0 0

0 0

TOTAL L2L2 L2 lo2

=

=n2 Class G Freq:

0.000 mph IN NNE N ENEEES jSE SSEJ SJ SSW SW WS WNWINW NNWITOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

3.5-7.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

7.5-12.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

12.5-18.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL 0

0[OI0 010101 0 0 0 0 00 0

A2L L Class All Freq:

1.000 mph

[NJ NNE JNE[ENEJE ESEJSEJFSSEJS SSW SWJ WSW Jw WNW JNWj NNWJ TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 1

0 1

1 o F1 0

1 0

1 0

T 3

0 0

10 3.5-7.5 3

5 10 7

8 9

10 6

3 3

4 3

8 8

7 7

101 7.5-12.5 4

10 19 14 2813 211720 13 20 38 28 40 23 5

313 12.5-18.5 23 10 32 6 9 1513,15 27 55 91 80 112,81 50 18 637 18.5-24 8

4 29 i15113 3

1 5 38 47 55 137 95 44 12 507

>24 21 19 6

5 3

0 1

0 0

7 2

3 95 82 13 8

265

_____48 97 48f Z 1a 41 48 39 1561 11 1511930 1833 59

Table A-2 (continued)

Apr-Jun 2004 Class A Freq:

0.173 mph N

NE NE ]ENE I EESE SE JSSEJ S (SSW SW WSI I WNWI NW INNWITOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

3.5-7.5 2

4 1

1 0

1 0

0 0

0 0

0 0

0 2

0 1 1 7.5-12.5 3

3 1 3 2

0 1

0 0

3 3

2 1

0 0

1 4

36 12.5-18.5. 1 5 1 0 1 9 6

2 5

7 2

8 29 5

9 3

3,2 11 136 18.5-24 1 2 1

2 4

4 0

0 1

5 42 3

0 0

1 5 8

1 1 108

>24 3

0 0

1 1

0 0

0 0

8 0

0 0

1 0 3

5 3

TOTAL 35 1181351 14171 7I 7 31 161 82 1 0 1 0 3 28 16 [3132 Class B Freq: 0.057 mph N INNET NE JENE E ESE [SE I SSEJ S JSSWJ SW JWSWJ W JWNW] NW [NNWITOTALI Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

3.5-7.5 3

1 3

0 1

1 1

0 0

0 0

0 0

0 0

1 11 7.5-12.5 1

1 1

4 2

3 1

4 6

3 2

0 0

0 0

2 30 12.5-18.5.

0 0

2 3

1 1

4 1

6 11 2

1 0

1 0

0 33 18.5-24 1

1 0

0 0

0 1

0 2

9 1

0 0

2 1

4 22

>24 1

0 0

0 0

0 0

0 0

2 1

0 0

4 1

0 9

TOTL 1 135j7 5

14125 61 0

J7 2 7

105 Class C Freq: 0.078 mph [N JNNEINE IENEJEJESET SE] SSE[ S JSSW 1SW IWSW I W JWNWI NW [NNWITOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

0 0

0 0

0 1

0 0

0 0

0 1

0 2

3.5-7.5 3

3 2

0 3

2 4

0 3

0 1

0 0

0 3

2 26 7.5-12.5 2

3 1

2 4

1 2 14 1 0 2

4 1

1 1

2 2

42 12.6-18.5. 2 0

1 0

7 2

2 12 5

1 8 3

0 3

0 2

3 50 18.5-24 0

0 0

0 0

0 0

0 0

9 3

0 0

2 0

0 14

>24 1

0 00 0

0 0

0 2

5 0

0 0

3 0

0 1 1 TOTAL I181-6 J 4[2 114 5J 21~~II J

161812 4

Class D Freq: 0.300 mph jN IJNNE INE I ENE E[ESE J~SE ISSEJI S I SSW [ SW IWSWI W JWNWJ NW INNWITOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

3 2

1 1

1 0

1 1

2 0

1 1

0 1

3 18 3.5-7.5 5

6 14 5

5 5

9 2

1 2

2 4

5 1

6 2

74 7.5-12.5 1

0 10 9

11 12 9

14 16 18 12 10 5

4 3

2 136 12.5-18.5, 2

2 0

2 11__

9 8

8 14 57 25 1

27 5

I1 1

.173 18.5-24 1

2 0

0 0

0 1

2 1

46 21 1

2 10 10 2

99

>24 1

0 0

0 0

0 0

0 0

20 6

0 0

14 7

9 57 TOA 110113126117 28 27 127 [271331145166 J17[40 1~

1428 J19[s57 60

Table A-2 (continued)

Apr-Jun 2004 Class E Frea:

0.276 mph JNJINNE IJNEI ENE I EI ESE SEISSEIS SSW SWIWSW I W WNW INWI NNWJ TOTAL Catm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 1

2 4

0 0

0 0

0 4

1 0

0 2

0 1

2 17 3.5-7.5 1

0 7 10 113 10 5 5

4 3

3 3

4 3

4 76 7.5-12.5 1

2 4

7 1823 109 8

12 7

6 14 10

,7 4

142 12.5-18.5 9

1 2

0 1I 3

3 3

6 17 20 15 33 18 10 4

145 18.5-24 4

3 0

0 0

0 0

0 0

12 31 5

20 14 4

4 97

>24 5

0 0

0 0

0 0

0 0

10 4

0 0

6 7

4 36 TOA 21 18 117 1 17 1301 29 1231f 17 3

5 61 29 1 721 52 12 21 513 Class F Freq:

0.093 mph JN[INNE INEJ ENE IE I ESE SE SSEISISSW ISW WSWI WI WNW INW INNWITOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 01 0

0 0.95-3.5 0

0 0

0 0

0 0

0 0

0 0

0 1

0 0

0 1

3.5-7.5 1

0 3

1 5

3 0

2 1

4 0

3 0

1 1

0 25 7.5-12.5 1

0 0

1 1

3 0

0 1

2 1

6 2

7 5

1 31 12.5-18.5 0

0 0

0 0

0 0

1 3

1 10 23 13 3

6 2

62 18.5-24 1

0 0

0 0

0 0

0 0

2 30 6

2 0

4 2

47

>24 0

2 0

0 0

0 0

0 0

0 3

0 0

1 1I 0

7 TOTAL j3 2

[3J 2 I6I6I0 3I5I9

~38 t11 12 171 5

173 Class G Freq:

0.023 mph ININNE NEIENE I EESE1SE ISSEISISSW I W WWI WNW JNW [NNWITOTAL Calm-0.95 0

0 0

0 10 0

0 0

0 0

0 0

0 0

0 0

0 0.95-3.5 0

0 0

1 0

0 0

0 0

0 1

0 0

0 1

0 3

3.5-7.5 0

0 2

1 1

0 0

0 0

1 1

0 0

0 1

0 7

7.5-12.5 0

0 0

0 0

0 1

0 0

0 2

4 3

0 0

0 10 12.5-18.5

.0 0

0 0

0 0

0 0

0 0

I1 6

I1 5

0 1

14 18.5-24 0

0 0

0 0

0 0

0 0

0 3

2 2

0 0

0 7

>24 0

0 0

0 0

0 0

0 0

0 1

0 0

0 0

0 1

TOTAL 0

0 2

2J2721+/-L2 0 I

12J6LL5 1

4 Class All Freq:

1.000 mph N

77 S

S EEE EESWISW WWIW WW N N

OA Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 1

5 6

2 1

1 0

1 6

3 1

1 4

0 4

5 41 3.5-7.5 1s 14 32 1826 1524 9

10 11 7

10 8

6 16 9

230 7.5-12.5 9

9 29 2536 43 23 31 4 40 30 28 25 22 18 15 427 12.5-18.5 28 13 24 1122,20 24.17 42133 66 655 80 35 21 22 613 18.5-24 19 7

2 4

4 0

2 3

8 120 92 14 26 43 27 23 394

>24 11 2

0 1

1 0

0 0

2 45 15 0

0 38 19 18 152 TOTAL 1831560 1 93( 11 901 79] 73J 61 1112[ 352(211 1 10 13 19 1857 61

Table A-2 (continued)

Jul-Sep 2004 Class A Freq: 0. 178 mphI N [NNEJ NE JENEJE]ESE SE JSSEI S [SSWI SW jWSWJ W JWNWj NW LNNWITOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

3.5-7.5 8

5 6

0 0

0 0

0 0

0 0

0 0

0 2

4 25 7.5-12.5 8

11 2

7 1

1 4

4 8

17 6

2 1

0 1

3 76 12.5-18.5, 22 5

2 4

1 1

1 3

10 52 15 4

0 1

0 4

125 18.5-24 2

3 0

2 0

0 0

0 2

17 2

0 0

0 1

9 38

>24 3

6 0

0 0

0 0

0 0

0 0

0 0

0 1

4 14 TOA 43130 1 0 1

22111216231611 Class S Freq: 0.077 mph N

NE NE ENE E

ESE SE SSE S

SSW SW WSW W IWNWI NW NNW ITOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

1 0

0 0

0 1

0 0

0 0

0 0

0 0

1 3

3.5-7.5 1

2 1

2 1

0 1

0 0

0 0

0 0

2 1

3 14 7.5-12.5 1

3 2

1 0

3 2

0 4

14 7

0 0

1 1

0 39 12.5-18.5. 1 5

1 1

1 0

0 2

3 24 9

0 1

0 0

4 52 18.5-24 0

1 0

2 1

0 0

0 0

3 0

0 0

2 0

1 10

>24 0

0 0

0 00 0

0 1

0 0

0 0

0 0

2 3

TOTAL j3 1121416 j3 3

4j 218 4111610111512 J11121 Class C Freq:

0.104 mph N JNNE] NE JENEIEIESEJ SE] SSEI S I SSWJI SW]jWSW[ W IWNWI NW NNWI TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 1

0 0

0 0

0 0

0 0

0 0

0 0

0 1

3.5-7.5 2

2 1

4 1

0 0

0 0

0 0

0 0

0 2

0 12 7.5-12.5 0

2 1

4 1

2 2

1 4

19 10 2

0 0

0 4

52 12.5-18.5 2

3 1

1 1

0 0

4 7

42 9

2 0

0 2

1 75 18.5-24 4

0 0

1 3

0 0

0 1

6 1

1 0

0 0

1 18

>24 0 0

0 0

0 0

0 3

0 0

0 0

0 0

2 5

TOTAL 8

7 4

105 6

TT 0

4 Class D Freq:

0.294 mph N IJNNEJI NE I ENE I EIESE] SE [SSEJ S ISSWI SW JWSWJ WI WW NWINNWITOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 1

1 1

0 0

2 1

1 0

2 0

1 0

0 0

1 11 3.5-7.5 4

5 8

10 5

1 5

3 4

0 0

2 0

0 3

4 54 7.6-12.5 4

4 0

2 5

7 11 6

26 31 20 7

3 6

5 2

139 12.5-18.5.

4 0,

2 8

3 5

5 7

21 67 20 8

14 0

1 2

167 18.6-24 4

2 2

5 4

0 0

0 2

21 120 2

1 2

1 7

73

>24 5

0 0

2 14T 0

0 0

2 2 10 0

0-0 0

0 15 TOTAL j22 12 113 27 121 115 122 117 155 11231 601 20 1118 11045 62

Table A-2 (continued)

Jul-Sep 2004 Class E Freq:

0.254 mph IN NNE JNE ]ENE[E[I ESE ISEIJSSEIS I SSW ISWI WSW IWNW I NW1INNWI TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 1

1 4

3 0

2 0

0 1

0 1

0 0

0 1

1 15 3.5-7.5 2

5 12 6

6 6

5 3

4 1

1 2

0 5

2 8

68 7.5-12.5 2

2 0

0 4

15 8

6 12 7

2 4

9 18 2

7 98 12.5-18.5

,2 0

1 0

0 0

6 15 12 23 16 14 17 18 23 4

151 18.5-24i 3 0

0 3

0 0

0 0

1 16 33 1

0 1

2 2

62

>24 0

0 0

1 0

0 0

0 0

0 1

0 10 0

1 0

3 TOTAL [ 10]

8J1171 13 1101 23 1191 24131471 54]

21

[261 42 1 312.i2..I 397 Class F Freq:

0.081 mph JNJINNE IJNEI ENE[IE[I ESEJSEJISSEJSJSSW SW] WSW [W WNW I NW] NNWI TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 2

1 0

1 0

0 1

1 1

0 0

0 0

0 7

3.5-7.5 0

0 0

1 5

3 1

3 1

4 2

2 2

4 0

0 28 7.5-12.5 0

0 0

0 1

2 1

2 3

5 3

5 4

0 0

1 27 12.5-18.5 1

0 0

0 0

0 1

2 2

7 12 6

5 4

3 3

46 18.5-24 1

0 0

0 0

0 0

1 0

3 1 1 0

0 1

2 0

19

>24 0

0 0

0 00 0

0 00 0

0 0

0 0

0 0

TOTAL 2

0 2 12161 6 13 811120 129]

13 1111 9 1514 1 127j Class G Freq:

0.011 mph IN NNE I NE IENE I EIESE SEISSEIS ISSW ISW1I WSW Iw W WNW INWI NNW jTOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 1

3.5-7.5 0

0 0

0 0

0 0

0 0

1 1

0 1

0 0

0 3

7.5-12.5 0

0 0

0 0

0 0

0 1

2 0

0 0

1 0

0 4

12.5-18.5 0

0 0

0 0

0 0

0 0,1 2

2 2

2 0

0 9

18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL 0(

0

_0

_010 1 01 0 1151-F31-2 13 13 1010 17 Class All Freq:

1.000 mph LNINNEINEIENEJEJIESEISEISSEIS I SSWJSW1 IWSWI WIWNW INW INNWI TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 2

3 8

4 0

5 2

1 2

4 2

1 0

0 1

3 38 3.5-7.5 17 19 28 23 18 10129 9

6 4

6 3

11 10 19 204 7.5-12.5 15 22 5

14 1230 2819 58 95 48 20 17 26 9

17 435 12.5-18.5 32 13 7

14 6

6

13. 33 55 216 83 36

.39 25 29 18 625 18.5-24 14 6

2 13 8

0 0

1 6

66 67 4

1 6

6 20 220

>24 8

6 0

3 4 0 0

0 6

2 1

0 0

0 2

8 40 TOTAL 88169 1 50 I71148 5 I551 63 11361 389 1205 1 67 1601 68 J567 85 15162 63

Table A-2 (continued)

Oct-Dec 2004 Class A Freq:

0.070 mph N I NE N ENE SE SSE SL k SS WISIW I IN N OA

=m09 0

010 0

0 0

0 0a.950395 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

3.5-72.5 2

0 0

0 0

0 0

0 0

0 0

0 0

0 1

1 4

12.5-18.5 3

0 0

0 0

0 0

0 0

4 1

2 1

3 9

7 30 18.5-24 5

2 10 0

0 0

0 0

1 2

0 0

0 1

7 8

36

>24 6

6 3

7 14 3

0 0

0 0

0 0

0 1

9 3

5 TOA 0 8j13 7 J14J 3jJ jJ 1

5 J 1261201 127 Class B Freq: 0.026-mph N

N EIEE E

EE S

S SW S SIW ININ N

OA Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

3.5-7.5 1

0 0

0 0

0 0

0 0

0 1

0 0

0 0

0 2

7.5-12.5 1

0 1

0 0

0 0

0 0

0 0

0 0

1 0

0 3

12.5-18.5 0

0 0

0 0

0 0

0 1

2 2

0 1

1 2

1 10 18.5-24 0

5 6

0 0

-0 0

0 1

3 0

1 0

0 2

1 19

>24 1

3 2

1 0

0 0

0 1

0 0

0 0

0 2

3 13 TTL3 8

I1 01 0101 01315 1 11 216 6

47 Class C Freq: 0.049 Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 1

1 0

0 0

0 0

0 0

0 0

0 1

0 3

3.5-7.5 1

1 0

1 0

0 0

0 0

0 0

0 1

0 3

0 7

7.5-12.5 0

0 1

0 1

0 0

0 0

0 1

0 1

3 0

0 7

12.5-18.5 0

1 3

2 0

2 3

0 0

2 6

1 2

0 2

3 27 18.5-24 2

4 6

0 0

0 3

1 1

2 1

2 3

0 2

1 2

>24 2

5 3

1 0

0 0

2 0

1 0

0 0

1 3

0 18 TOTAL 5

11114 j 5

1 2161 3 1

(

7~( 4~ ji 4

90 Class D Freq:

0.468 Calm-0.95 0

0 0

0 0

0 0

0 0

0.95-3.5 2

0 0

0 0

0 1

2 0

0 0

0 0

0 0

0 5

3.5-7.5 2

9 7

3 1

5 5

2 4

2 3

4 1

2 1

3 54 7.5-12.5 3

2 15 8

5 6

9 17 18 16 20 6

12 14 2

3 156 12.5-18.5 5

2 19 9

1 4

14 9

10 36 37 35 37 14 16 8

256 18.5-24 21 6

19 6

4 5

12 6

4 15 1 1 8

16 18 43 14 208

>24 15 29 6

7 2

10 5S 7

3 0

0 1

25 29 1 9 17 175 TOA 48 48 j663 113 30 146 43 3

69171 j54 91 J77 81 I 45 951 64

Table A-2 (continued)

Oct-Dec 2004 Class E Freq: 0.315 mph I NJNNEINEIENEIEIESEISEISSE IS I SSWls I S WSWI W IWNWI NU JNNW[TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 1

0 3

2 1

1 0

0 0

1 0

0 1

1 0

0 11 3.5-7.5 1

2 1

3 3

4 2

3 4

4 2

3 4

3 5

5 49 7.5-12.5 10 0

1 0

4 6

12 11 6

19 12 1

10 20 20 10 142 12.5-18.5 12 1

0 0

0 0

6 24 17 31 62 21 37 19 26 13 269 18.5-24 3

0 0

0 0

0 1

8 6

13 11 11 7

10 10 7

87

>24 4

0 0

0 0

0 0

0 0

0 0

1 0

4 6

2 17 TOTAL L3113 j5 5

5 1 I 11 21 46 331 68187137159 517 37 [575 Class F Freq: 0.070 mph I N NNE[NE JENE1 EsESE SE SSEI S S

W WW WW N N

OA Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 1

0 0

0 0

0 0

0 0

1 0

0 0

1 3

3.5-7.5 3

0 0

0 1

1 0

1 0

2 1

2 0

1 1

2 15 7.5-12.5 0

0 0

0 0

1 2

1 1

1 3

10 7

7 6

2 41 12.5-18.5.

0 0

0 0

0 0

0 2

2 11 6

18 5

4 2

0 50 18.5-24 0

0 0

0 0

0 0

0 0

3 8

1 3

1 1

2 19 24 0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 TOTAL IT0 0

1 TI2 4

17118 32 15113 T10 71128 Class G Freq: 0.002 Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

3.5-7.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

7.5-12.5 0

0 0

0 0

0 0

0 1

1 0

0 0

0 0

0 2

12.5-18.5 0

0 0

0 0

0 0

0 0

0 2

0 0

0 0

0 2

18.5-24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

>24 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

TOTAL IO[O1ObOIO 0101 oji 1 j2J of 0o

[1211 Class All Freq: 1.000 mph ININNE I NE ENE E IESE I SE ISSEI S ISSW I SW WSW[ W IWNWI NW INNWITOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 3

0 5

3 1

1 1

2 0

1 0

1 1

1 1

1 22 3.6-7.5 10 12 8

7 5

10 7

6 8

8 7

9 6

6 11 11 131 7.5-12.5 18 2

18 8

10 13 23 29 26 37 36 17 30 45 28 16 356 12.5-18.5 20 4

22 11 1

6 23 35 30 86 116 77 83 41 57 32 644 18.5-24 31 17 41 6

4 5

16 15 13 38 31 23 29 30 65 33 397

>24 28 43 14 16 16 13 5

9 4

1 0

2 25 35 39 25 275 TOTL[ 110 78 I1081 51 37 1 48 7

96 j81 1171119011291174 1581201 1118 11825 65

Table A-2 (continued)

Jan-Dec 2004 Class A Freq:

0.138 mph N INNE [NE JENEJIJEIESE JSE (SSEf S [ SSWI SW jWSWJ W WNW[ NW NNW TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

3.5-7.5 13 9

9 1

0 1

0 0

0 0

0 0

0 0

5 6

44 7.5-12.5 17 19 23 9

1 2

4 5

11 20 9

3 2

2 6

11 144 12.5-18.5 48 19 43 12 7

7 9

6 20 87 27 23 13 16 20 29 384 18.5-24 19 7

28 12 6 j0 0

1 9

70 12 1

7 31 22 34 259

>24 15 21 8

8 15 3

0 0

0 13 0

_0 6

23 17 1

4 TOTAL 110 75 111 42 j29 13 1 12 401 190 48 1271281721701 98 1978 Class B Freq: 0.051 mph N jNNE fNE ~ENEI EEJSE JSSEI S I SSW I SW IWSWI WI WNWJ NW INNWITOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

1 0

0 0

0 1

0 0

0 0

0 0

0 0

1 3

3.5-7.5 6

4 5

2 2

1 2

0 0

0 1

0 0

2 2

4 31 7.5-12.5 13 4

5 6

2 6

3 4

11 17 9

1 0

3 1

2 77 12.5-18.5 2

5 5

5 2

1 4,4 12 40 19 3

8 2

2 6

120 18.6-24 1

7 5

5 2

0 2

0 3

23 2

3 9

7 7

6 92

>24 3

4 3

4 0

0 0

0 2

2 2

1 3

5 4

5 38 TOTAL 15121312 8181218128 821 33 1 2019 1612416 Class C Freq: 0.0768E EIEE S

S SWIS SIN N

OA mph N

NNE JNE IENEIIS[S s

SISISJS]W IWNWI N]NWjOA Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 2

1 0

0 0

0 1

0 0

0 0

0 2

0 6

3.5-7.5 6

6 5

5 7

2 4

0 3

0 2

0 1

0 9

2 52 7.5-12.5 12 6

4 6

8 3

5 5

15 23 19 5

3 6

4 6

120 12.5-18.5 7

4 10 5

11.4 6

9 23 69 18 4

19 6

7 9

211 18.5-24 6

4 0

7 6 10j 3 j2 3

21 7

3 11 8

2 2

95

>24 4

10 3

3 1

0 1

2 5

7 1

0 4

7 3

2 5

TOTAL 25 3

3427 331 9 19 1 8 50 120 471 12138 127127 1~

Class D Freq:

0.412 mphlI N JNNE jNE JENEL E jESEJSEJSSE[

S SSWJSW JWSWj W IWNWI NW IJNNW(OA Calm-0.951 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 3

4 4

1 1

4 2

4 1

4 0

2 2

2 1

4 39 3.5-7.5 12 24 33 21 13 14 24 11 9

5 8

13 8

5 12 13 225 7.5-12.5 10 10 34 29 39 36 48 42 72 73 63 49 36 39 18 9

605 12.5-18.5 24 10 24 20 17 32 35 30 54 195 137 90 145 54 49 19 935 18.5-24 34 12 21 11 13 8

15 8

8 8

83 58 127 94 81 29 700

>24 35 33 6

9 8

10 5

7 5

3 6

3 106 103

28.

26 413 TOTAL1 118 193 122191 j91 1104117101149 1 398 1 297 121514241 2971189I110 2917 66

Table A-2 (continued)

Jan-Dec 2004 Class E Freq:

0.250 mph N

NNE NE E E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 4

3 11 6

1 3

0 0

6 2

2 0

3 2

2 3

48 3.5-7.5 4

7 21 23 22 19 22 13 15 11 6

8 11 18 13 19 232 7.5-12.5 13 4

5 10 34 46 33 36 31 40 24 18 42 65 38 21 460 12.5-18.5 23 2

3 0

1 3

18 46 38 79 113 72 103 84 68 21 674 18.5-24 10 4

0 3

0 0

1 8

9 42 81 22 32 32 23 13 280

>24 11 0

0 1

0 0

0 0

0 10 5

1 1

16 20 8

73 TOTAL 65 20 40 43 58 71 74 1031 99 184 12311 121 1921 217 11641 851 1767 Class F Freq:

0.064 mph lN NNE NElENE E ESESElSSEI S SSW SWl WSW l W WNW NW NNW [TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 3

1 0

1 0

0 1

1 1

1 1

0 0

1 11 3.5-7.5 4

0 3

2 12 7

1 6

3 10 3

7 4

6 2

2 72 7.5-12.5 1

0 0

1 2

6 3

4 6

9 8

23 14 17 11 4

109 12.5-18.5 1

0 0

0 0

0 1

5 7

19 37 48 23 13 11 5

170 18.5-24 2

0 0

0 0

0 0

1 0

8 49 7

5 2

7 4

85

>24 0

2 0

0 0

0 0

0 0

0 3

0 0

1 1

0 7

TOTAL 81 2 6

4 114 114 5

16 17 47 101 86 47 39 32 16 Class G Freq:

0.009 mph lN lNNE NElENE E lESESElSSE S SSW lSWWSW W WNW NW NNW l TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 0

0 0

1 0

0 0

0 0

1 1

0 0

0 1

0 4

3.5-7.5 0

0 2

1 1

0 0

0 0

2 2

0 1

0 1

0 10 7.5-12.5 0

0 0

0 0

0 1

0 2

3 2

4 3

1 0

0 16 12.5-18.5 0

0 0

0 0

0 0

0 0

1 5

8 3

7 0

1 25 18.5-24 0

0 0

0 0

0 0

0 0

0 3

2 2

0 0

0 7

>24 0

0 0

0 0

0 0

0 0

0 1

0 0 j 0 1 0 1 0 1

TOTAL 0

2 l2 1

0 1

0 2

7 14 14 9

8 l2 1 11 63 Class All Freq:

1.000 mph lN NNE NEIENE E ESElSEISSE S

SSW lSWl WSW lW NW NNW TOTAL Calm-0.95 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.95-3.5 7

8 20 10 2

8 3

4 9

8 4

3 6

4 6

9 111 3.5-7.5 45 50 78 55 57 44 53 30 30 28 22 28 25 31 44 46 666 7.5-12.5 46 43 71 61 86 99 95 96 148 185 134 103 100 133 78 53 1531 12.5-18.5 103 40 85 42 38 47 73 100 154 490 356 248 314 182 157 90 2519 18.5-24 72 34 74 38 27 1 8 21 20 32 262 237 96 193 174 1142 88 1518

>24 68 70 20 25 1 24 13 6

9 12 55 18 5

12 1

73 59 732 TOTAL 1 3411 245 1 3481 231 1 234 1 219 12511 259 j 385 j 1028 1 7711 483 1 758 1 679 1 500 1 345 j 7077 67