Boiler A Monthly Log Make & Model: Cleaver -Brooks CB107-500 Design Capacity: 21 MMBtu/hr 150 gals/hr Month Operatina Hrs July-05 August-05 September-05 October-05 November-05 December-05 January-06 February-06 March-06 April-06 May-06 June-06 0
0 0
2 193.4 200.2 170.7 200.2 166.7 Fuel Usaae (gals) 0 0
0 300 29,014 30,003 25,609 30,003 25,004 Heating Value (Btus/gal) 140,000 140,000 140,000 140,000 140,000 140,000 140,000 140,000 140,000 140,000 140,000 140,000
% Sulfur 0.13 0.13 0.13 0.13 0.13 0.13 0.15 0.15 0.15 (fic2 0
- e
/)It 5
,~ '&
Cat, p
Boiler B Monthly Log Make & Model: Cleaver -Brooks CB1 07-500 Design Capacity: 21 MMBtu/hr 150 gals/hr Month Oneratinci Hrs July-05 August-05 September-05 October-05 November-05 December-05 January-06 February-06 March-06 April-06 May-06 June-06 0
0 0
2 193.4 200.2 170.7 200.2 166.7 Fuel Usane (gals) 0 0
0 300 29,014 30,003 25,609 30,003 25,004 Heatina Value Btus/gal 140,000 140,000 140,000 140,000 140,000 140,000 140,000 140,000 140,000
% Sulfur 0.16 0.16 0.16 0.16 0.16 0.16 0.19 0.19 0.19
Emergency Diesel Generator "A" Monthly Log Make & Model: Alco, Model No. 251 F18GS Design Capacity: 25 MMBtu/hr 182.5 gals/hr Month Operating Hrs July-05 August-05 September-05 October-05 November-05 December-05 January-06 February-06 March-06 April-06 May-06 June-06 2
3.3 2.4 2
2.2 2.2 2
2.4 2.1 Fuel Usage (gals) 365 602 438 365 402 402 365 438 383 Heating Value (Btus/gal) 137,000 137,000 137,000 137,000 137,000 137,000 137,000 137,000 137,000
% Suffur 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06
Emergency-Diesel Generator "B" Monthly Log Make & Model: Alco, Model No. 251 Fl 8GS Design Capacity: 25 MMBtu/hr 182.5 gals/hr Month Operatina Hrs July-05 August-05 September-05 October-05 November-05 December-05 January-06 February-06 March-06 April-06 May-06 June-06 2.2 2.3 2.1 2.1 2.2 2
2.4 2.3 2.4 Fuel Usaae (gals) 401.5 420 383 383 402 365 438 420 438 Heating Value (Btus/gal) 137,000 137,000 137,000 137,000 137,000 137,000 137,000 137,000 137,000
% Sulfur 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.08 0.08
Station Blackout Diesel (SBO) Monthly Log Make & Model: Alco, Model No. 251-F Design Capacity: 21.2 MMBtu/hr 154.7 gals/hr Month ODeratingz Hrs July-05 August-05 September-05 October-05 November-05 December-05 January-06 February-06 March-06 April-06 May-06 June-06 0
0 1.7 5
0 3.8 0
0 1.9 Fuel Usaae (gals) 0 0
257 757 0
575 0
0 288 Heating Value (Btustgal) 137,000 137,000 137,000 137,000 137,000 137,000 137,000 137,000 137,000
% Sulfur 0.06 0.06 0.08 0.08 0.08 0.08 0.08 0.06 0.06
Security Diesel Monthly Log Make & Model: Cummins, Model No. KrA 19-G2 Design Capacity: 3.6 MMBtu/hr 26.2 gals/hr Month Operating Hrs July-05 August-05 September-05 October-05 November-05 December-05 January-06 February-06 March-06 April-06 May-06 June-06 1.58 11.51 2.6 2.97 3.83 1.33 7
3.7 8.5 Fuel Usage (gals) 41.396 288 65 74.25 96 33 175 93 213 Heatina Value (Btus/gal) 137,000 137,000 137,000 137,000 137,000 137,000 137,000 137,000 137,000
% Sulfur 0.09 0.09 0.09 0.09 0.09 0.09 0.09 0.06 0.06
Technical Support Center Diesel Monthly Log Make & Model: Cummins, Model No. 35ODFM Design Capacity: 3.5 MMBtu/hr 25 gals/hr Month Operatincu Hrs July-05 August-05 September-05 October-05 November-05 December-05 January-06 February-06 March-06 April-06 May-06 June-06 1.27 0.67 0.68 0.77 0.78 0.67 3.5 0.6 0
Fuel Usaae (gals) 31.75 17 17 19.25 20 17 88 15 0
Heatina Value (Btus/gal) 137,000 137,000 137,000 137,000 137,000 137,000 137,000 137,000
% Sulfur 0.09 0.09 0.09 0.09 0.09 0.09 0.09 0.06
Fire Pump Diesel Monthly Log Make & Model: Caterpillar 3406 Design Capacity: 2.1 MMBtu/hr 15 gals/hr (Note: Diesel is automatically run loaded for 1 hr every week)
Month Operating Hrs July-05 August-05 September-05 October-05 November-05 December-05 January-06 February-06 March-06 April-06 May-06 June-06 4
4 4
4 4
4 4
4 5
Fuel Usaae (gals) 60 60 60 60 60 60 60 60 75 Heating Value (Btus/gal) 137,000 137,000 137,000 137,000 137,000 137,000 137,000 137,000 137,000
% Sulfur 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06
J1 v
WWTP Diesel Monthly Log Make & Model: John Deere 4045T Design Capacity: 0.6 MMBtu/hr 4.6 gals/hr (Note: Diesel is automatically run loaded for 1 hr every Tuesday)
Month Operating Hrs July-05 August-05 September-05 October-05 November-05 December-05 January-06 February-06 March-06 April-06 May-06 June-06 4
4 4
4 4
4 6.8 7
5 Fuel Usage (gals) 18.4 18.4 18.4 18.4 18.4 18.4 31.28 32.2 23 Heating Value (Btus/gal) 137,000 137,000 137,000 137,000 137,000 137,000 137,000 137,000 137,000
% Sulfur 0.09 0.09 0.09 0.09 0.09 0.09 0.09 0.09 0.09
'S Space Heater Monthly Log Make & Model: Beckett Burners (3 units)
Design Capacity: 2-3 gals/hr (2 units @ 2g/h & 1 unit @ 3g/h)
(Note: During heating season, 24 hr/day run time is assumed)
Month OoeratinFi Hrs July-05 August-05 September-05 October-05 November-05 December-05 January-06 February-06 March-06 April-06 May-06 June-06 0
0 0
0 720 744 744 672 744 Fuel Usage (gals) 0 0
0 0
5040 5208 5208 4704 5208 Heating Value (Btus/gal) 137,000 137,000 137,000 137,000 137,000 137,000 137,000 137,000 137,000
%Sutfur 0.09 0.09 0.09 0.09 0.09 0.09 0.09 0.09 0.09