ML061390109

From kanterella
Jump to navigation Jump to search
Cancellation of Public Meeting with PSEG Nuclear LLC, Regarding Salem Nuclear Generating Station Service Water System and Compliance with Generic Letter 2004-02
ML061390109
Person / Time
Site: Salem  
Issue date: 05/11/2006
From: Stewart Bailey
Plant Licensing Branch III-2
To: Darrell Roberts
Plant Licensing Branch III-2
Bailey S, NRR/ADRO/DORL, 415-1321
References
GL-04-002
Download: ML061390109 (6)


Text

CANCELLED May 11, 2006 MEMORANDUM TO: Darrell J. Roberts, Chief Plant Licensing Branch 1-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation FROM:

Stewart N. Bailey, Senior Project Manager /RA/

Plant Licensing Branch 1-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation

SUBJECT:

FORTHCOMING MEETING WITH PSEG NUCLEAR LLC, REGARDING SALEM NUCLEAR GENERATING STATION SERVICE WATER SYSTEM AND COMPLIANCE WITH GENERIC LETTER 2004-02 DATE & TIME:

Monday, May 22, 2006 9:00 - 11:00 a.m.

LOCATION:

U.S. Nuclear Regulatory Commission (NRC)

One White Flint North 11555 Rockville Pike, Room O-4 B6 Rockville, Maryland PURPOSE:

Working-level meeting to discuss planned modifications to the service water (SW) system and actions in response to Generic Letter (GL) 2004-02 at Salem Nuclear Generating Station, Units 1 and 2. The meeting will discuss an amendment that will remove accumulators from the SW system and simplify control and flow parameters. The meeting will also discuss an extension for Unit 2 commitment to GL 2004-02 (containment sumps and debris blockage) beyond December 31, 2007, until the Unit 2 steam generators are replaced in spring 2008. The meeting agenda is enclosed.

CATEGORY 1*:

This is a Category 1 Meeting. The public is invited to observe this meeting and will have one or more opportunities to communicate with the NRC after the business portion, but before the meeting is adjourned.

MEETING CONTACTS:

Stewart Bailey, NRR Carleen Sanders, NRR 301-415-1321 301-415-1603 snb@nrc.gov cjs2@nrc.gov

  • Commissions Policy Statement on Enhancing Public Participation in NRC Meetings, (67 FR 36920), May 28, 2002 CANCELLED

CANCELLED PARTICIPANTS:

Participants from the NRC include members of the Office of Nuclear Reactor Regulation.

NRC LICENSEE S. Bailey A. Fakhar F. Saba K. Mathur C. Sanders M. Ambrosino M. L. Scott A. Johnson J. Hopkins J. Rowey L. Whitney J. Simons T. O. Martin J. Mallon D. Shum J. Tatum Docket Nos. 50-272 and 50-311

Enclosure:

Agenda cc w/encl: See next page CANCELLED

ML061390109 OFFICE LPL1-2:GE LPL1-2:PM LPL1-2:LA LPL1-2:BC NAME CSanders SBailey CRaynor DRoberts DATE 5/11/06 5/11/06 05/11/06 5/11/06

Enclosure CANCELLED MEETING AGENDA WORKING-LEVEL MEETING TO DISCUSS THE SERVICE WATER SYSTEM AND COMPLIANCE WITH GENERIC LETTER 2004-02 SALEM NUCLEAR GENERATING STATION, UNIT NOS. 1 AND 2 PSEG NUCLEAR LLC DOCKET NOS. 50-272 AND 50-311 Schedule Discussion Topics 9:00 - 9:15 a.m.

Introductory remarks/Introductions 9:15 - 10:00 a.m.

An extension on Salem Nuclear Generating Stations actions with response to Generic Letter 2004-02 sump requirements 10:00 - 10:45 a.m.

A proposed amendment to remove accumulators from the service water system and to simplify system controls and flow parameters 10:45 - 11:00 a.m.

Additional questions/Comments and summary CANCELLED

Salem Nuclear Generating Station, Unit Nos. 1 and 2 cc:

Mr. Dennis Winchester Vice President - Nuclear Assessment PSEG Nuclear P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. Thomas P. Joyce Site Vice President - Salem PSEG Nuclear P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. George H. Gellrich Plant Support Manager PSEG Nuclear P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. Carl J. Fricker Plant Manager - Salem PSEG Nuclear - N21 P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. Darin Benyak Director - Regulatory Assurance PSEG Nuclear - N21 P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. James Mallon Manager - Licensing 200 Exelon Way, KSA 3-E Kennett Square, PA 19348 Mr. Steven Mannon Manager - Regulatory Assurance P.O. Box 236 Hancocks Bridge, NJ 08038 Jeffrie J. Keenan, Esquire PSEG Nuclear - N21 P.O. Box 236 Hancocks Bridge, NJ 08038 Township Clerk Lower Alloways Creek Township Municipal Building, P.O. Box 157 Hancocks Bridge, NJ 08038 Mr. Paul Bauldauf, P.E., Asst. Director Radiation Protection Programs NJ Department of Environmental Protection and Energy CN 415 Trenton, NJ 08625-0415 Mr. Brian Beam Board of Public Utilities 2 Gateway Center, Tenth Floor Newark, NJ 07102 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Senior Resident Inspector Salem Nuclear Generating Station U.S. Nuclear Regulatory Commission Drawer 0509 Hancocks Bridge, NJ 08038