W3F1-2006-0024, 12-Month Special Report SR-06-001-00 on the 13th Refueling Steam Generator Tube Inservice Inspection, Waterford Unit 3
| ML061390029 | |
| Person / Time | |
|---|---|
| Site: | Waterford |
| Issue date: | 05/17/2006 |
| From: | Murillo R Entergy Nuclear South, Entergy Operations |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| W3F1-2006-0024 SR-06-001-00 | |
| Download: ML061390029 (43) | |
Text
- Entergy Entergy Nuclear South Entergy Operations, Inc.
17265 River Road Killona, LA 70057-3093 Tel 504-739-6715 Fax 504-739-6698 rmurilleentergy.com Robert J. Murillo Licensing Manager, Acting Waterford 3 W3FI-2006-0024 May 17, 2006 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC.20555
SUBJECT:
12-Month Special Report SR-06-001-00 on the 13th Refueling Steam Generator Tube Inservice Inspection Waterford Steam Electric Station, Unit 3 Docket No. 50-382 License No. NPF-38
REFERENCES:
- 1.
Entergy letter dated May 24, 2005, Combined C-3 and 15 day Special Report SR-05-001-00 on the 13 th Refueling Outage Steam Generator Tube Inservice Inspection (W3F1-2005-0037)
Dear Sir or Madam:
Attached is Special Report (SR) Number SR-06-001-00 for Entergy Operations, Inc (EOI)
Waterford Steam Electric Station Unit 3. This report provides the complete results of the Refuel 13 Steam Generator Tube Inservice Inspection. This special report is being submitted in accordance with Technical Specifications 4.4.4.5.b and 6.9.2.
If you have any questions or require additional information, please contact Ron Williams at 504-739-6255.
Very truly yours, RJM/RLW/cbh Attachments
- 1. Special Report SR-06-001 Steam Generator Eddy Current Examination (13TH Refueling Outage)
- 2. Percent of Wall-Thickness Penetrations for S/G #1 - RF13
- 3. Percent of Wall-Thickness Penetrations for S/G #2 - RFI 3
- 4. Summary of RF13 Plugging Repairs
- 5. Summary of NDE Techniques
/D(17
W3Fl-2006-0024 Page 2 cc:
Dr. Bruce S. Mallett Regional Administrator U. S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-8064 NRC Senior Resident Inspector Waterford Steam Electric Station Unit 3 P.O. Box 822 Killona, LA 70066-0751 U.S. Nuclear Regulatory Commission Attn: Mr. Mel B. Fields MS O-7E1 Washington, DC 20555-0001 Wise, Carter, Child & Caraway ATTN: J. Smith P.O. Box 651 Jackson, MS 39205 Winston & Strawn ATTN: N.S. Reynolds 1700 K Street, NW Washington, DC 20006-3817 Morgan, Lewis & Bockius LLP ATTN: T.C. Poindexter 1111 Pennsylvania Avenue, NW Washington, DC 20004 Louisiana Department of Environmental Quality Office of Environmental Compliance Surveillance Division P.O. Box 4312 Baton Rouge, LA 70821-4312 American Nuclear Insurers Attn: Library Town Center Suite 300S 29t S. Main Street West Hartford, CT 06107-2445
Attachment I To W3FI-2006-00024 Special Report SR-06-001-00 Steam Generator Eddy Current Examination (13th Refueling Outage) to W3FI-2006-0024 Page 1 of 9 SPECIAL REPORT SR-06-001-00 STEAM GENERATOR EDDY CURRENT EXAMINATION (1 3 TH REFUELING OUTAGE)
1.0 INTRODUCTION
This report is submitted in accordance with Technical Specification 4.4.4.5.b. that requires the complete results of the steam generator tube inservice inspection from Refuel #13 to be submitted in a special report pursuant to Technical Specification 6.9.2, within 12 months following completion of the inspection.
The report includes:
- 1.
Number and extent of tubes inspected. (Table 3.1)
- 2.
Location and percent of wall-thickness penetration for each indication of an imperfection. (Attachments 2 and 3)
- 3.
Identification of tubes plugged or sleeved. (Tables 5.2 and 5.3)
The steam generator tube inservice inspection was performed to meet and exceed the requirements of Technical Specification 3/4.4.4. Waterford 3 performed all S/G eddy current testing examinations in accordance with EPRI 'PWR Steam Generator Examination Guidelines" and its Appendix H qualified techniques.
2.0 Steam Generator Design The Waterford 3 Model 70 re-circulating steam generators were designed and fabricated by Nuclear Steam System Supplier Combustion Engineering (CE), Inc. in accordance with ASME Code,Section III NB for Class I vessels. The Waterford 3 steam generators each consist of 9,350 high temperature mill annealed Inconel 600 U-tubes arranged in a one-inch inner diameter triangular pitch pattern representing 103,574 ft2 of heat transfer area. The U-tubes are 3/4" O.D. by 0.048" nominal wall thickness explosively expanded the full depth of the tubesheet (CE's Explansion Process) and welded to the primary cladding. The secondary tube bundle support structure consists of carbon steel eggcrates. The secondary supports are arranged in the following order:
seven full horizontal eggcrate supports six horizontal partial eggcrate supports
- two anti-vibration straps (hot and cold batwings) seven vertical straps (also called Batwings at Waterford 3) to W3Fl-2006-0024 Page 2 of 9 3.0 Inspection Results 3.1 RF1 3 Scope (Number and Extent Tested)
The Refuel #13 S/G eddy current testing (ECT) program consisted of the inspection plans listed in Table 3.1 The inspection included 100% of tubes Tube End Hot to Tube End Cold (bobbin) and 100% Hot Leg Top of the Tubesheet (rotating coil) +3 to -11 inches.
Table 3.1 RF13 ECT Inspection INSPECTION RESULTS Below is a breakdown of the initial scope and expansions based on number of examinations:
Test Type Extent Tested
- Tubes
% Scope Expansion Steam Generator #1 Bobbin TEH to TEC 8658 100 No RPC ET HL
+3 to -11 8779 100 No RPC Small Radius U-bends (Rows 07H to 07C 121 100 No 1-2) (Straight Legs with Bobbin)
- RPC +PT 100% of all Dents at 77 100 No Eggcrate Supports > 2.0 V RPC +PT 20% all Dents at Eggcrate 28 20 No
>2.OV at Diagonals RPC +PT 20% all Dings >5.0V 52 20 No (RF12)
RPC +PT 20% all Wear at Batwings 67 20 No (RF12)
RPC +PT 100% all new Wear 188 100 No reported at Batwings RPC +PT of all DSI 211 100 No Special Interest - Adjacent PLP 21 NA Steam Generator #2 Bobbin TEH to TEC 8744 100 No RPC ET HL
+3 to -11 8866 100 No RPC Small Radius U-bends (Rows 07H to 07C 122 100 No 1-2) (Straight Legs with Bobbin)
- RPC +PT 100% of all Dents at 103 100 No Eggcrate Supports > 2.0 V RPC +PT all Dents at Eggcrate >2.OV 21 20 No at Diagonals II to W3F1-2006-0024 Page 3 of 9 RPC +PT 20% all Dings >5.0V 61 20 No (RF12)
RPC +PT 20% all Wear at Batwings 67 20 Yes RPC +PT 100% all new Wear 214 100 Yes reported at Batwings RPC +PT of all DSI 97 100 No Cracks at Batwing Wear Expansion to 169 100 All BW Wear and EC Wear Diagonal Bar Shift (Batwing) 07C to BW9 42 NA Investigation Special Interest -Adjacent PLP 13 NA
- NOTE: The U-Bend Low Row (1-2) region of the respective tubes in each SIG were examined with "+Pt. "and straight sections Inspected with bobbin coil.
3.2 Tube Integrity Acceptable tube integrity was demonstrated at the end of Cycle 13 and condition monitoring requirements on burst pressure (3ANOP) and accident leakage rates were satisfied for all forms of degradation mechanisms identified during the Refuel #13 S/G eddy current testing. All indications identified were well below their associated structural limits. The Waterford 3 Refuel #13 Condition Monitoring Report was documented via Westinghouse Document SG-SGDA 23, 'Waterford 3 RF13 Steam Generator Condition Monitoring Report and Interim Cycle 14 Operational Assessment." The report is contained under Entergy's Document ER-W3-2005-0226-000.
As part of Waterford 3's adherence to perform In-Situ Screening in accordance with EPRI, TR-107620, "Steam Generator In-Situ Pressure Test Guidelines",
Rev. 1, all indications identified were screened with no tests required.
3.3 Degradation Mechanisms During RE 3, indications were detected that were suggestive of the following degradation mechanisms:
Axial ODSCC at non-dented hot and cold leg eggcrate intersections (SG31 and SG32)
Axial ODSCC in the hot leg sludge pile freespan region and expansion transition region (SG31 and SG32)
Circumferential ODSCC at the hot leg TTS expansion transition (SG31)
Circumferential PWSCC at the hot leg expansion transition and expanded tubesheet region (SG31 and SG32)
- Axial PWSCC at the hot leg expansion transition and expanded tubesheet region (SG31)
Wear at eggcrate, diagonal bar, and vertical strap sites (SG31 and SG32)
Tube wear due to foreign objects (SG31 and SG32)
Attachment I to W3Fl-2006-0024 Page 4 of 9 A new degradation mechanism discovered during RF13 is 2 failed diagonal bars (Batwings) within SG #2. The failed batwings were identified through eddy current signal analysis and confirmed with visual examination. The condition is entered into the site's Corrective Action Program (CR-WF3-2005-01977). The response to the condition was discussed with the NRC Staff through several conference calls and site resident interface. The NRC Staff provided a letter dated March 31, 2006 (TAC NO. MC6047) to the site for close out of these discussions. A rigorous assessment of the condition was completed in December 2005 which modeled the thermo hydraulic conditions and wear. The assessment concluded that operation until the end of Cycle 14 was acceptable.
This Complicated Assessment was added to the existing Operational Assessment results.
NDE techniques used to detect the identified degradation mechanisms are included in Attachment 5 to this report. Attachment 4 provides a tabular summary of the tubes repaired due to various degradation mechanisms. The summary does not include tubes plugged as a response (Corrective Action) to the 2 failed diagonal bars (Batwings) under the site's Corrective Action Program.
4.0 Location and Percent of Wall-Thickness Penetration for Each Indication of an Imperfection The inspection data is summarized in Attachments 2 and 3. The only flaws sized and left in service are for wear. All wear > 40% through wall was removed from service by plugging.
5.0 Percentage of Tubes Plugged or Sleeved Table 5.1 list the repairs made in RF13 and the cumulative repairs to date:
Table 5.1 Tubes Repaired to Date SG #1 SG #1 SG #2 SG #2 Plugs
% Plugged Plugs
% Plugged PriortoRF13 571 6.11 %
484 5.18%
RF13 247 N/A 223 N/A Total 818 8.75%
707 7.56%
Sleeved Tubes 0
N/A 0
N/A Preventative plugging and stabilization was completed to address potential concerns with the batwings under actions contained in the Corrective Action Program response. contains the repaired tubes by various degradation modes exclusive of the batwing corrective actions. The batwing response required additional plugging of 124 in SG #1 and 166 in SG #2. These tubes did not contain flaws.
to W3FI-2006-0024 Page 5 of 9 On May 11, 2005 Waterford 3 successfully completed all S/G eddy current examinations and plugging activities. Additionally, Waterford 3 performed visual inspection of the S/G tubesheets for evidence of leaking tube plugs. As a result of the tubesheet scans, Waterford 3 did not identify any leaking tube plugs, thus closing the S/G inspection. The SG bowl closeouts were completed on May 11, 2005 to complete the RF#1 3 inspection.
The SIG man-ways were re-installed on May 17, 2005.
Tables 5.2 and 5.3 include the list of tubes plugged during Waterford 3's RF13 Outage.
to W3Fl-2006-0024 Page 6 of 9 Table 5.2 Steam Generator #1 - Tubes Plugged during RFN3 Tube Tube Tube Count Row Column Count Row Column Count Row Column 1
1 63 83 26 68 165 56 88 2
1 113 84 26 108 166 57 75 3
1 171 85 28 68 167 57 83 4
2 26 86 28 108 168 57 85 5
2 64 87 29 69 169 58 86 6
2 112 88 29 107 170 58 88 7
2 172 89 30 52 171 59 85 8
3 63 90 31 69 172 59 87 9
3 113 91 31 107 173 59 133 10 3
171 92 31 121 174 60 78 11 4
18 93 32 50 175 60 86 12 4
64 94 33 55 176 60 88 13 4
112 95 33 69 177 61 85 14 4
172 96 33 107 178 61 87 15 5
113 97 35 69 179 61 89 16 5
133 98 37 117 180 62 84 17 5
135 99 40 54 181 62 86 18 6
64 100 40 56 182 62 88 19 6
112 101 41 59 183 63 85 20 6
114 102 42 144 184 63 87 21 6
118 103 43 129 185 64 68 22 6
132 104 45 71 186 64 86 23 6
162 105 45 105 187 64 88 24 7
63 106 45 143 188 65 85 25 7
113 107 46 72 189 66 84 26 8
36 108 46 104 190 67 11 27 8
44 109 46 128 191 68 66 28 8
64 110 47 69 192 68 130 29 8
112 111 47 73 193 69 65 30 8
116 112 47 103 194 69 67 31 8
140 113 47 105 195 69 85 32 8
156 114 47 135 196 69 115 33 9
1 115 48 52 197 69 141 34 9
65 116 48 64 198 70 84 35 9
111 117 48 74 199 70 86 36 10 64 118 48 104 200 71 85 37 10 112 119 49 73 201 72 66 38 11 19 120 49 75 202 72 98 39 11 57 121 49 77 203 73 85 40 11 65 122 49 79 204 75 117 41 11 111 123 49 97 205 76 80 to W3Fl-2006-0024 Page 7 of 9 Tube Tube Tube Count Row Column Count Row Column Count Row Column 42 11 115 124 49 99 206 78 90 43 11 159 125 49 101 207 78 94 44 12 64 126 49 123 208 79 127 45 12 112 127 50 76 209 81 149 46 12 120 128 50 78 210 84 44 47 13 19 129 50 98 211 86 94 48 13 65 130 50 100 212 86 100 49 13 111 131 50 102 213 86 118 50 14 2
132 50 158 214 88 60 51 14 66 133 51 77 215 89 127 52 14 110 134 51 99 216 90 144 53 15 65 135 52 80 217 91 41 54 16 66 136 52 96 218 92 108 55 16 134 137 52 98 219 97 89 56 16 136 138 53 51 220 98 132 57 17 19 139 53 79 221 99 39 58 17 23 140 53 81 222 100 76 59 17 67 141 53 83 223 101 47 60 17 109 142 53 87 224 102 94 61 17 121 143 53 89 225 102 144 62 18 66 144 53 93 226 103 101 63 18 110 145 53 95 227 107 55 64 18 116 146 53 97 228 107 57 65 19 113 147 53 99 229 112 32 66 20 2
148 54 82 230 113 45 67 20 56 149 54 84 231 115 109 68 20 60 150 54 86 232 119 81 69 20 66 151 54 88 233 126 122 70 20 68 152 54 90 234 127 121 71 20 108 153 54 92 235 128 122 72 21 67 154 54 94 236 130 66 73 21 109 155 54 106 237 136 112 74 21 123 156 54 108 238 137 111 75 22 68 157 55 83 239 138 110 76 22 108 158 55 85 240 138 112 77 22 142 159 55 87 241 139 111 78 23 67 160 55 91 242 139 113 79 23 109 161 55 97 243 141 67 80 23 115 162 56 82 244 143 67 81 24 68 163 56 84 245 143 69 82 24 108 164 56 86 246 143 71 247 67 83 to W3Fl-2006-0024 Page 8 of 9 Table 5.3 Steam Generator #2 - Tubes Plugged during RF13 Tube Tube Tube Count Row Column Count Row Column Count Row Column 1
11 11 75 64 82 149 57 91 2
56 12 76 66 82 150 59 91 3
36 16 77 68 82 151 61 91 4
5 19 78 70 82 152 123 91 5
78 28 79 72 82 153 54 92 6
33 35 80 74 82 154 56 92 7
24 38 81 76 82 155 58 92 8
78 38 82 78 82 156 53 93 9
119 39 83 80 82 157 55 93 10 34 44 84 82 82 158 54 94 11 75 49 85 84 82 159 56 94 12 40 50 86 53 83 160 53 95 13 85 53 87 55 83 161 83 95 14 85 55 88 57 83 162 52 96 15 95 59 89 59 83 163 49 97 16 23 61 90 61 83 164 51 97 17 25 61 91 63 83 165 50 98 18 106 62 92 65 83 166 74 98 19 3
63 93 67 83 167 49 99 20 5
63 94 69 83 168 51 99 21 7
63 95 71 83 169 50 100 22 23 63 96 73 83 170 49 101 23 2
64 97 75 83 171 71 101 24 4
64 98 77 83 172 48 102 25 6
64 99 79 83 173 88 102 26 8
64 100 81 83 174 47 103 27 10 64 101 83 83 175 57 103 28 12 64 102 85 83 176 46 104 29 9
65 103 91 83 177 45 105 30 11 65 104 54 84 178 29 107 31 13 65 105 56 84 179 31 107 32 15 65 106 58 84 180 33 107 33 14 66 107 60 84 181 20 108 34 16 66 108 62 84 182 22 108 35 18 66 109 64 84 183 24 108 36 20 66 110 66 84 184 26 108 37 21 67 111 68 84 185 28 108 38 22 68 112 70 84 186 17 109 39 24 68 113 72 84 187 21 109 40 26 68 114 74 84 188 23 109 to W3FI-2006-0024 Page 9 of 9 Tube Tube Tube Count Row Column Count Row Column Count Row Column 41 28 68 115 76 84 189 143 109 42 29 69 116 78 84 190 14 110 43 31 69 117 80 84 191 18 110 44 33 69 118 82 84 192 20 110 45 45 71 119 84 84 193 96 110 46 46 72 120 55 85 194 9
ill 47 48 74 121 57 85 195 11 111 48 142 74 122 65 85 196 13 111 49 49 75 123 67 85 197 15 111 50 50 76 124 69 85 198 2
112 51 52 76 125 145 85 199 4
112 52 49 77 126 147 85 200 6
112 53 50 78 127 58 86 201 8
112 54 54 78 128 64 86 202 12 112 55 56 78 129 53 87 203 1
113 56 49 79 130 55 87 204 3
113 57 51 79 131 57 87 205 5
113 58 53 79 132 59 87 206 7
113 59 55 79 133 63 87 207 9
113 60 57 79 134 65 87 208 5
115 61 52 80 135 58 88 209 22 118 62 54 80 136 60 88 210 54 118 63 56 80 137 64 88 211 138 118 64 58 80 138 53 89 212 48 128 65 53 81 139 55 89 213 128 130 66 55 81 140 57 89 214 127 131 67 57 81 141 59 89 215 46 134 68 77 81 142 61 89 216 84 136 69 95 81 143 54 90 217 18 140 70 54 82 144 56 90 218 31 141 71 56 82 145 58 90 219 47 143 72 58 82 146 60 90 220 49 143 73 60 82 147 62 90 221 6
146 74 62 82 148 55 91 222 2
148 223 2
150 To W3FI-2006-0024 Percent of Wall-Thickness Penetration for SIG #1 - RF13 to W3Fl-2006-0024 Page 1 of 12 Percent of Wall-Thickness Penetrations for S/G #1 - RF1 3 Indication Row Column Indication
% TW Support Location 1
35 5
PCT 10 BW5 0.77 2
41 5
PCT 16 06H
-0.76 3
8 6
PCT 9
03H 0.71 4
42 6
PCT 7
BW5 0.84 5
5 7
PCT 17 07H
-0.68 6
5 7
PCT 8
07H
-0.52 7
55 9
PCT 18 BW4 0.78 8
57 9
PCT 19 BW4 0.87 9
32 10 PCT 9
BW5 1.01 10 62 10 PCT 8
BW5
-0.82 11 64 10 PCT 20 BW4 0.8 12 39 11 PCT 9
BW5
-0.77 13 53 11 PCT 17 BW4 1.08 14 55 11 PCT 18 BW5
-0.81 15 55 11 PCT 18 BW5 0.97 16 57 11 PCT 19 BW4
-0.85 17 65 11 PCT 15 BW4 0.86 18 67 11 PCT 33 BW5 0.83 19 49 13 PCT 7
BW1 0.45 20 55 13 PCT 22 BW4 0.79 21 55 13 PCT 20 BW5 0.58 22 59 13 PCT 18 BW6 0.6 23 38 14 PCT 9
BW5 0.88 24 68 14 PCT 20 BW4 0.78 25 74 14 PCT 7
BW1
-1.8 26 74 14 PCT 12 BW4 0.93 27 19 15 PCT 17 BW5
-0.82 28 19 15 PCT 16 BW5 1.1 29 57 15 PCT 17 BW5
-0.91 30 57 15 PCT 17 BW6
-0.82 31 61 15 PCT 23 BW5
-0.87 32 61 15 PCT 20 BW5 0.94 33 61 15 PCT 32 BW6
-0.82 34 61 15 PCT 21 BW6 0.75 35 36 16 PCT 19 BW5 0.94 36 64 16 PCT 18 BW4
-0.75 37 64 16 PCT 25 BW5
-0.91 38 64 16 PCT 18 BW5 0.99 39 36 18 PCT 21 BW5
-1.18 40 62 18 PCT 23 BW4 0.83 41 66 18 PCT 22 BW5
-0.8 42 57 19 PCT 20 BW4 0.72 43 42 20 PCT 19 BW5
-0.71 44 62 20 PCT 14 BW4
-0.78 45 62 20 PCT 21 BW4 0.75 46 76 20 PCT 9
BW6 0.56 to W3FI-2006-0024 Page 2 of 12 Percent of Wall-Thickness Penetrations for SIG #1 - RF13 I Indication I Row I Column I Indication I % TW I SupDort Location 47 31 21 PCT 16 BW5 0.83 48 55 21 PCT 4
BW6 0.79 49 71 21 PCT 8
BW5 0.71 50 81 21 PCT 23 08C 0.79 51 32 22 PCT 11 BW5
-0.91 52 64 22 PCT 20 BW4 0.59 53 78 22 PCT 19 BW5 0.85 54 78 22 PCT 18 BW6 0.98 55 47 23 PCT 15 BW5 1.01 56 52 24 PCT 21 BW4 0.72 57 70 24 PCT 13 BW5
-0.8 58 70 24 PCT 11 BW6 0.94 59 52 26 PCT 20 BW4 0.86 60 54 26 PCT 20 BW6 0.82 61 66 26 PCT 20 BW4
-0.85 62 19 27 PCT 18 BW5 1.24 63 61 27 PCT 8
BW4 0.96 64 67 27 PCT 7
BW5 0.76 65 69 27 PCT 4
BW5 0.93 66 71 27 PCT 16 BW4
-0.83 67 73 27 PCT 19 BW4
-0.83 68 77 27 PCT 21 BW4
-0.77 69 77 27 PCT 21 BW5
-0.86 70 77 27 PCT 21 BW5 0.99 71 77 27 PCT 26 BW6
-0.96 72 77 27 PCT 22 BW6 0.82 73 83 27 PCT 16 BW6
-0.85 74 87 27 PCT 26 BW7
-0.88 75 50 28 PCT 13 BW5 0.91 76 53 29 PCT 7
BW4 0.79 77 83 29 PCT 12 BW5
-0.68 78 54 30 PCT 21 BW4
-0.69 79 53 31 PCT 7
BW4 0.94 80 87 31 PCT 11 BW3 0.85 81 105 31 PCT 17 BW7
-0.7 82 107 31 PCT 11 BW7
-0.68 83 42 32 PCT 14 BW5 0
84 58 32 PCT 20 BW4
-0.84 85 82 32 PCT 17 BW4 0.69 86 98 32 PCT 21 BW3 0.89 87 100 32 PCT 10 09H
-0.93 88 114 34 PCT 18 BW9 1.48 89 61 35 PCT 9
BW5 0.86 90 61 35 PCT 9
BW6 0.87 91 77 35 PCT 8
BW5
-0.76 92 105 35 PCT 24 BW5 I
to W3Fl-2006-0024 Page 3 of 12 Percent of Wall-Thickness Penetrations for SIG #1 - RF13 Indication Row Column I Indication
% TW I Support Location 93 34 36 PCT 11 BW5 0.86 94 59 37 PCT 12 BW6
-1.13 95 66 38 PCT 22 BW4
-0.89 96 76 38 PCT 17 BW5
-0.76 97 80 38 PCT 18 BW4 0.99 98 80 38 PCT 16 BW5
-0.74 99 80 38 PCT 26 BW6
-0.69 100 82 38 PCT 22 BW5
-0.74 101 82 38 PCT 34 BW6
-0.63 102 19 39 PCT 14 BW5 0.9 103 21 39 PCT 16 BW5 0.74 104 51 39 PCT 13 BW6 1.31 105 107 39 PCT 9
BW5 0.74 106 113 39 PCT 26 BW7 1.05 107 2
40 PCT 8
04C 0.77 108 42 40 PCT 9
BW5 0.96 109 50 40 PCT 9
BW5
-0.89 110 37 41 PCT 16 BW5
-1 111 39 41 PCT 31 BW5
-0.82 112 55 41 PCT 8
BW5 0.75 113 87 41 PCT 14 BW9 2
114 56 42 PCT 19 BW4 0.71 115 70 42 PCT 17 BW6 0.8 116 88 42 PCT 20 BW3
-0.45 117 102 42 PCT 26 BW3
-1.01 118 104 42 PCT 8
BW3
-1.04 119 110 42 PCT 9
BW3 0.74 120 116 42 PCT 13 BW6
-0.98 121 120 42 PCT 15 BW3
-0.62 122 120 42 PCT 18 BW3 0.6 123 1
43 PCT 6
07H 0.72 124 59 43 PCT 6
BW5 0.93 125 105 43 PCT 7
BW3 0.92 126 110 44 PCT 7
BW3 0.92 127 37 45 PCT 7
BW5 1.1 128 105 45 PCT 9
BW7 1.11 129 127 45 PCT 15 BW8 0.71 130 128 46 PCT 5
02H
-0.11 131 67 47 PCT 6
BW6
-0.45 132 88 48 PCT 9
BW3
-0.72 133 45 49 PCT 11 BW5 0.67 134 59 49 PCT 8
BW5 0.97 135 93 49 PCT 16 BW3 0.77 136 115 49 PCT 16 BW7
-0.81 137 127 49 PCT 20 BW3
-0.67 138 127 49 PCT 18 BW3 0.72 to W3FI -2006-0024 Page 4 of 12 Percent of Wall-Thickness Penetrations for SIG #1 - RF 3 I Indication I Row I Column I Indication I % TW I Support Location 139 120 50 PCT 7
BW2 0.37 140 39 51 PCT 9
BW5 0.8 141 113 51 PCT 18 BW6 0.89 142 119 51 PCT 18 BW3 0.87 143 119 51 PCT 18 BW4
-0.73 144 46 52 PCT 25 BW5 0.75 145 52 52 PCT 16 BW5
-0.78 146 134 52 PCT 17 BW2 0.42 147 43 53 PCT 11 BW5 1.01 148 105 53 PCT 14 BW3
-0.78 149 117 53 PCT 19 BW3
-0.71 150 54 54 PCT 16 BW4 0.98 151 54 54 PCT 17 BW5 0.95 152 82 54 PCT 8
BW5
-0.65 153 82 54 PCT 20 BW5 1.14 154 82 54 PCT 8
BW6
-0.61 155 19 55 PCT 16 BW5 0.98 156 57 55 PCT 8
BW4 0.76 157 59 55 PCT 7
BW4 0.85 158 24 56 PCT 6
BW5
-0.7 159 50 56 PCT 20 BW5
-0.78 160 50 56 PCT 25 BW5 1.06 161 126 56 PCT 8
BW2 0.87 162 23 57 PCT 16 BW5 0.84 163 51 57 PCT 5
BW4 1.23 164 135 57 PCT 11 10H 0.74 165 28 58 PCT 15 BW5
-0.84 166 76 58 PCT 9
BW6
-0.71 167 96 58 PCT 17 BW3
-0.89 168 96 58 PCT 13 BW3 0.81 169 85 59 PCT 9
BW4 0
170 129 59 PCT 17 BW3
-0.65 171 24 60 PCT 8
BW5
-0.67 172 30 60 PCT 22 BW5 0.8 173 32 60 PCT 17 BW5 0.97 174 138 60 PCT 21 09H
-1.16 175 81 61 PCT 14 BW4 0.87 176 26 62 PCT 19 BW9
-1.89 177 82 62 PCT 9
BW4
-0.88 178 100 62 PCT 19 BW3
-1.06 179 138 62 PCT 4
01H 0.53 180 19 63 PCT 19 BW5 0.81 181 61 63 PCT 20 BW5 1.12 182 63 63 PCT 18 BW5 1.32 183 63 63 PCT 19 BW6 1.05 184 4
64 PCT 16 03H
-0.77 to W3F1 -2006-0024 Page 5 of 12 Percent of Wall-Thickness Penetrations for SIG #1 - RF13 I Indication I Row I Column I Indication I % TW I Support I Location 185 46 64 PCT 33 BW5
-0.87 186 43 65 PCT 11 BW5
-0.84 187 81 65 PCT 18 BW4
-0.92 188 83 65 PCT 15 BW4 0.84 189 137 65 PCT 17 BW4 0.84 190 44 66 PCT 25 BW5 0.72 191 48 66 PCT 28 BW5
-0.81 192 48 66 PCT 21 BW9 1.93 193 50 66 PCT 23 BW5
-0.65 194 78 66 PCT 9
BW5 0.84 195 25 67 PCT 7
BW5
-0.73 196 31 67 PCT 7
BW5 1.1 197 51 67 PCT 32 BW4 0.82 198 51 67 PCT 20 BW5
-0.94 199 135 67 PCT 17 BW3
-0.71 200 20 68 PCT 15 BW1
-1.83 201 22 68 PCT 9
BW9 1.96 202 24 68 PCT 14 BW9 1.48 203 56 68 PCT 8
BW4
-0.84 204 84 68 PCT 18 BW5
-0.93 205 86 68 PCT 17 BW6 0.66 206 96 68 PCT 19 BW3
-0.86 207 46 70 PCT 30 BW5 0.73 208 92 70 PCT 8
BW3 0.59 209 100 70 PCT 18 BW3
-0.8 210 100 70 PCT 15 BW6
-0.83 211 75 71 PCT 15 BW4
-0.82 212 109 71 PCT 17 BW7 0.86 213 48 72 PCT 34 BW5
-0.8 214 48 72 PCT 31 BW5 0.06 215 48 72 PCT 29 BW5 0.89 216 106 72 PCT 11 BW7 0.7 217 126 72 PCT 8
BW3 1.09 218 144 72 PCT 7
BW9 1.66 219 47 73 PCT 12 BW1 -1.49 220 105 73 PCT 17 BW5 0.76 221 145 73 PCT 28 BW1 0.7 222 48 74 PCT 12 BW5
-0.7 223 48 74 PCT 14 BW5
-0.06 224 48 74 PCT 14 BW5 0.73 225 108 74 PCT 11 BW3
-0.9 226 116 74 PCT 10 BW2 0.99 227 116 74 PCT 11 BW3 0.99 228 138 74 PCT 12 BWI
-0.34 229 97 75 PCT 11 BW3
-0.8 230 97 75 PCT 6
BW7
-0.89 to W3Fl-2006-0024 Page 6 of 12 Percent of Wall-Thickness Penetrations for SIG #1 - RF1 3 I Indication I Row I Column I Indication I % TW I SusDort I Location I 231 101 75 PCT 16 BW3 0.77 232 98 76 PCT 21 BW3
-0.77 233 118 76 PCT 8
BW4 0.72 234 146 76 PCT 15 BW1 1.5 235 49 77 PCT 8
BW9
-0.53 236 51 77 PCT 23 BW4 1.21 237 105 77 PCT 15 BW6 0.87 238 105 77 PCT 13 BW7 0.87 239 123 77 PCT 21 BW6
-0.69 240 133 77 PCT 12 BW2
-0.84 241 133 77 PCT 16 BW3
-0.53 242 133 77 PCT 16 BW4
-0.71 243 68 78 PCT 16 BW6 1.04 244 126 78 PCT 9
BW3 1
245 130 78 PCT 10 BW3
-0.94 246 136 78 PCT 12 BW2
-0.88 247 146 78 PCT 11 BW4 1.08 248 49 79 PCT 33 BW9
-1.69 249 61 79 PCT 17 BW5 1.08 250 78 80 PCT 19 BW5
-0.78 251 78 80 PCT 16 BW6 0.79 252 80 80 PCT 18 BW5
-0.83 253 146 80 PCT 21 BW1
-1.68 254 83 81 PCT 8
BW3 0.97 255 107 81 PCT 18 BW3 0.78 256 143 81 PCT 19 03H
-0.89 257 82 82 PCT 19 BW5 0.75 258 53 83 PCT 24 BW9
-1.78 259 53 83 PCT 46 BW9 1.69 260 55 83 PCT 33 BW9 2
261 67 83 PCT 20 BW9
-1.8 262 97 83 PCT 10 BW7 0.86 263 119 83 PCT 20 07C
-0.19 264 123 83 PCT 15 BW6
-1.11 265 123 83 PCT 16 BW7 0.8 266 147 83 PCT 16 06C
-0.22 267 62 84 PCT 15 BW9
-1.71 268 62 84 PCT 7
BW9 1.99 269 82 84 PCT 6
BW6
-0.89 270 82 84 PCT 8
BW6 0.95 271 98 84 PCT 9
BW3
-0.83 272 71 85 PCT 17 BW9
-1.91 273 73 85 PCT 14 BW9
-1.82 274 81 85 PCT 12 BW9
-1.92 275 97 85 PCT 15 BW3 0.84 276 141 85 PCT 34 BW3
-0.9 to W3Fl-2006-0024 Page 7 of 12 Percent of Wall-Thickness Penetrations for SIG #1 - RF13 I Indication I Row I Column I Indication I % TW I Support Location 277 147 85 PCT 13 09H 0
278 54 86 PCT 8
BW1
-1.73 279 54 86 PCT 24 BW9 1.96 280 56 86 PCT 13 BW9 1.96 281 58 86 PCT 33 BW9 1.93 282 60 86 PCT 26 BW9 1.91 283 62 86 PCT 29 BW9 1.9 284 64 86 PCT 10 BW9 1.95 285 66 86 PCT 10 BW4
-0.86 286 80 86 PCT 13 BW9 1.71 287 82 86 PCT 10 BW9 0.24 288 90 86 PCT 10 BW3
-0.9 289 90 86 PCT 9
BW3 0.75 290 92 86 PCT 8
BW3 0.82 291 92 86 PCT 8
BW4 0.68 292 53 87 PCT 42 BW9
-2 293 53 87 PCT 25 BW9 1.62 294 85 87 PCT 13 BW4 0.84 295 60 88 PCT 9
BW9 1.95 296 62 88 PCT 11 BW9 1.98 297 64 88 PCT 22 BW9 1.86 298 146 88 PCT 5
BW1
-1.62 299 146 88 PCT 14 BW1 1.6 300 146 88 PCT 9
BW9 1.44 301 69 89 PCT 12 BW6 0.77 302 147 89 PCT 18 BWI
-1.65 303 80 90 PCT 9
BW4 0.78 304 88 90 PCT 9
BW4 1.53 305 126 90 PCT 9
BW2 0.88 306 89 91 PCT 15 BW6
-0.88 307 121 91 PCT 17 02H
-0.91 308 147 91 PCT 12 BW9 1.8 309 54 92 PCT 11 08H 0.39 310 130 92 PCT 10 BW2 0.75 311 144 92 PCT 8
04H 0.83 312 144 92 PCT 9
BW2 0.69 313 95 93 PCT 15 BW3
-0.81 314 117 93 PCT 22 BW2 0.86 315 139 93 PCT 15 BW5 0.87 316 69 95 PCT 13 BW6 0.94 317 113 95 PCT 21 BW3
-0.9 318 121 95 PCT 16 BW3 0.79 319 145 95 PCT 20 BW9
-1.45 320 76 96 PCT 8
BW5
-0.8 321 82 96 PCT 14 BW5
-0.83 322 90 96 PCT 9
BW3
-0.85 to W3FI-2006-0024 Page 8 of 12 Percent of Wall-Thickness Penetrations for SIG #1 - RF1 3 l Indication I Row I Column I Indication I % TW I Support I Location I 323 92 96 PCT 8
BW3 0.87 324 83 97 PCT 15 BW5
-1.03 325 83 97 PCT 15 BW6
-0.81 326 83 97 PCT 7
BW6 0.87 327 89 97 PCT 14 BW6 0.95 328 127 97 PCT 21 BW8 0.82 329 139 97 PCT 20 BW2 0.67 330 50 98 PCT 16 BW9
-1.96 331 78 98 PCT 15 BW6 0.79 332 100 98 PCT 8
BW3 0.93 333 128 98 PCT 8
BW6 0.64 334 49 99 PCT 19 BW1 2
335 49 99 PCT 24 BW9
-1.82 336 51 99 PCT 20 BW9
-1.97 337 143 99 PCT 18 BW5 0.82 338 70 100 PCT 15 BW5
-0.84 339 78 100 PCT 19 BW5
-0.81 340 78 100 PCT 24 BW6 0.78 341 146 100 PCT 12 BW9
-1.57 342 73 101 PCT 10 BW4
-0.78 343 117 101 PCT 19 BW2 0.81 344 123 101 PCT 19 BW7 0.8 345 133 101 PCT 19 BW2
-0.79 346 145 101 PCT 20 BW1 1.74 347 145 101 PCT 20 BW9 1.75 348 84 102 PCT 17 BW3 0.82 349 86 102 PCT 16 BW3 0.87 350 92 102 PCT 17 BW3 0.76 351 94 102 PCT 18 BW3 0.81 352 100 102 PCT 18 BW5
-0.83 353 125 103 PCT 20 BW2 0.73 354 139 103 PCT 16 BW4
-0.75 355 143 103 PCT 17 BW2 0.75 356 143 103 PCT 15 BW3 0.75 357 145 103 PCT 27 BW1 1.84 358 145 103 PCT 20 BW2
-0.22 359 145 103 PCT 34 BW8 0.8 360 145 103 PCT 21 BW9
-1.66 361 48 104 PCT 7
BW9
-1.93 362 94 104 PCT 18 BW4 0.93 363 100 104 PCT 19 BW3
-0.85 364 45 105 PCT 11 BW5
-0.82 365 45 105 PCT 11 BW5 0.84 366 125 105 PCT 15 BW9 1.39 367 141 105 PCT 23 09H
-0.31 368 143 105 PCT 17 BW2 0.72 to W3Fl-2006-0024 Page 9 of 12 Percent of Wall-Thickness Penetrations for SIG #1 - RF13 Indication I Row Column I Indication I % TW Support I Location 369 100 106 PCT 20 BW3 0.68 370 102 106 PCT 19 BW4
-0.92 371 117 107 PCT 21 BW7 0.86 372 143 107 PCT 16 BW1 2
373 24 108 PCT 28 BW5 0
374 42 108 PCT 23 BW5
-0.81 375 42 108 PCT 9
BW5 0.84 376 78 108 PCT 23 BW4
-0.8 377 78 108 PCT 21 BW5
-0.77 378 78 108 PCT 16 BW6
-0.84 379 140 108 PCT 12 08H 0.78 380 107 109 PCT 21 BW7 0.83 381 141 109 PCT 20 BW2 0.67 382 143 109 PCT 19 08H 0.77 383 94 110 PCT 12 BW3 0.75 384 106 110 PCT 19 BW3 0.8 385 128 110 PCT 19 BW7 0.73 386 39 111 PCT 26 BW5 0
387 61 111 PCT 18 BW4 0.76 388 139 111 PCT 21 BW2
-0.78 389 22 112 PCT 7
BW5 0.75 390 42 112 PCT 9
BW5
-0.71 391 42 112 PCT 11 BW5 0.93 392 141 113 PCT 13 BW9
-1.53 393 56 114 PCT 8
BW5
-0.9 394 56 114 PCT 7
BW5 0.97 395 45 115 PCT 20 BW5
-0.63 396 49 115 PCT 21 BW5
-0.65 397 53 115 PCT 20 BW5 0.8 398 61 115 PCT 21 BW4 1.11 399 91 115 PCT 17 BW9
-0.06 400 6
116 PCT 7
03H 0.74 401 54 116 PCT 9
BW6 0.75 402 85 117 PCT 17 BW6 0.88 403 99 117 PCT 19 BW4
-0.85 404 103 117 PCT 20 BW4
-0.89 405 107 117 PCT 18 BW7 0.82 406 18 118 PCT 8
01H 0.76 407 102 118 PCT 21 BW3 0.89 408 61 119 PCT 18 BW4 0.8 409 135 119 PCT 34 BW2
-0.8 410 135 119 PCT 26 BW2 0.73 411 135 119 PCT 12 BW3
-0.86 412 135 119 PCT 29 BW3 0.78 413 135 119 PCT 30 BW4
-0.88 414 135 119 PCT 27 BW4 0.93 to W3FI-2006-0024 Page 10 of 12 Percent of Wall-Thickness Penetrations for SIG #1 - RF13 I Indication I Row I Column [Indication I % TW I Support I Location 415 135 119 PCT 20 BW7
-0.75 416 50 120 PCT 8
BW5 0.82 417 54 120 PCT 7
BW5
-0.95 418 54 120 PCT 8
BW5 0.8 419 131 121 PCT 16 BW5
-0.76 420 133 121 PCT 28 BW2
-0.84 421 133 121 PCT 35 BW2 0.69 422 133 121 PCT 19 BW3
-0.59 423 133 121 PCT 18 BW4
-0.79 424 132 122 PCT 10 BW5 0.71 425 75 123 PCT 18 BW6 0.75 426 74 124 PCT 27 BW5
-0.92 427 74 124 PCT 9
BW5 1.18 428 74 124 PCT 12 BW6
-0.92 429 132 124 PCT 8
08H 0.81 430 133 125 PCT 20 07C
-1.11 431 72 126 PCT 12 BW4
-0.94 432 72 126 PCT 18 BW4 0.83 433 72 126 PCT 9
BW5
-1.23 434 72 126 PCT 9
BW5 0.14 435 72 126 PCT 9
BW6 0.95 436 82 126 PCT 9
BW6 0.77 437 61 127 PCT 18 BW4 0.81 438 123 127 PCT 18 BW2 0.75 439 127 127 PCT 17 BW3 0.8 440 131 127 PCT 18 07H 0.75 441 76 128 PCT 13 BW4 0.63 442 76 128 PCT 14 BW5
-0.84 443 76 128 PCT 12 BW5 1.06 444 76 128 PCT 14 BW6
-0.77 445 76 128 PCT 25 BW6 0.92 446 98 128 PCT 11 BW3
-0.77 447 127 129 PCT 19 BW2
-0.57 448 113 131 PCT 17 BW6 0.69 449 117 131 PCT 19 BW2 0.95 450 119 131 PCT 18 BW2 0.8 451 117 133 PCT 17 BW2 0.67 452 50 134 PCT 9
BW5
-0.94 453 74 134 PCT 12 r
BW6 1.01 454 59 135 PCT 19 BW5
-0.84 455 92 136 PCT 9
BW3
-1.05 456 92 136 PCT 10 BW3 1.09 457 92 136 PCT 11 BW7
-0.76 458 55 137 PCT 19 BW4 0.66 459 55 137 PCT 18 BW5 0.78 460 63 137 PCT 22 BW5
-0.89 to W3FI-2006-0024 Page 11 of 12 Percent of Wall-Thickness Penetrations for SIG #1 - RF13 Indication Row Column I Indication
% Tw Support I Location 461 ill 137 PCT 19 BW3
-0.67 462 2
138 PCT 5
07H 0.12 463 78 138 PCT 14 BW4
-0.93 464 82 138 PCT 9
BW4
-1.03 465 82 138 PCT 9
BW4 0.72 466 82 138 POT 12 BW5 0.52 467 82 138 PCT 23 BW6 1.1 468 57 139 PCT 16 BW4 0.72 469 61 139 PCT 18 BW4 0.74 470 67 139 PCT 18 08C 0.87 471 76 140 PCT 9
BW4
-1.06 472 76 140 PCT 22 BW6 0.82 473 82 140 PCT 17 BW4 0.83 474 82 140 PCT 24 BW6
-0.81 475 82 140 PCT 11 BW6 0.76 476 92 140 PCT 6
02H 0.8 477 107 141 PCT 20 BW3
-0.86 478 66 142 PCT 22 BW4
-0.74 479 76 142 PCT 18 BW4 0.82 480 78 142 PCT 21 BW4
-0.89 481 78 142 PCT 19 BW5 0.14 482 78 142 PCT 23 BW6
-0.87 483 82 142 PCT 25 BW6
-0.86 484 53 143 PCT 21 BW4 0.89 485 69 143 PCT 18 BW4
-0.8 486 97 143 PCT 20 BW3
-0.67 487 97 143 PCT 18 BW7 0.52 488 48 144 PCT 27 BW5
-0.87 489 48 144 PCT 13 BW5 0.92 490 74 144 PCT 7
BWi
-1.63 491 74 144 PCT 9
BW5 0.93 492 74 144 PCT 12 BW6 0.87 493 78 144 PCT 28 BW4
-0.99 494 78 144 PCT 21 BW4 0.73 495 78 144 PCT 10 BW5
-0.82 496 78 144 PCT 10 BW5 0.4 497 78 144 PCT 8
BW6
-0.83 498 78 144 PCT 22 BW6 1.01 499 104 144 PCT 10 BW3
-0.93 500 69 145 PCT 18 BW4
-0.69 501 95 145 PCT 18 09C 0.91 502 97 145 PCT 17 BW7 0.6 503 107 145 PCT 17 BW3
-0.75 504 100 146 PCT 8
BW4
-0.92 505 100 146 PCT 7
BW6
-0.95 506 100 146 PCT 8
BW6 0.86 to W3Fl-2006-0024 Page 12 of 12 Percent of Wall-Thickness Penetrations for SIG #1 - RF13 I Indication I Row I Column I Indication I % TW I Support I Location 507 102 146 PCT 16 BW4
-0.82 508 104 146 PCT 9
BW3
-0.88 509 57 147 PCT 22 BW5 0.42 510 71 147 PCT 16 BW5 0.84 511 81 147 PCT 19 BW6 0.87 512 87 147 PCT 18 BW3
-0.7 513 87 147 PCT 15 BW4 0.65 514 94 148 PCT 17 BW7
-0.85 515 81 149 PCT 22 08C 0.8 516 83 149 PCT 23 BW7 0.72 517 83 155 PCT 10 08C
-0.59 518 44 156 PCT 10 BW5 0.66 519 50 156 PCT 17 BW5
-0.75 520 59 157 PCT 10 BW4 0.95 521 72 158 PCT 12 BW4
-0.9 522 82 158 PCT 22 01C 0.87 523 81 159 PCT 11 BW9 1.82 524 62 164 PCT 17 BW5
-0.91 525 68 164 PCT 10 BW4
-1.03 526 49 165 PCT 9
BW5 0.88 527 19 167 PCT 24 BW5 0.83 528 40 168 PCT 8
BW5 0.84 529 40 170 PCT 20 BW5 1
530 25 173 PCT 15 BW5
-1.04 531 5
175 PCT 11 01C
-0.2 To W3FI-2006-0024 Percent of Wall-Thickness Penetration for SIG #2 - RF13 to W3FI-2006-0024 Page 1 of 13 Percent of Wall-Thickness Penetrations for SIG #2 - RF13 Indication Row Column Indication
% TW Support Location 1
3 1
PCT 32 BW9 1.03 2
19 3
PCT 28 BW5 0.74 3
36 4
PCT 15 BW5
-0.92 4
46 6
PCT 20 BW5
-0.93 5
27 7
PCT 10 BW5 0.73 6
34 8
PCT 17 BW5 0.72 7
41 9
PCT 12 BW5
-0.3 8
44 10 PCT 24 BW5 0.99 9
67 11 PCT 28 BW6
-0.89 10 23 15 PCT 10 BW5
-0.88 11 33 15 PCT 14 BW5
-0.92 12 44 16 PCT 35 BW5
-0.96 13 44 16 PCT 18 BW5 0.82 14 35 17 PCT 11 BW5
-1.09 15 53 17 PCT 11 BW4 0.2 16 48 18 PCT 39 BW5
-0.77 17 48 18 PCT 30 BW5 0.98 18 4
20 PCT 20 06C
-0.02 19 74 20 PCT 19 BW9
-1.59 20 78 20 PCT 16 BW4
-0.87 21 80 20 PCT 15 BW9 1.7 22 90 20 PCT 27 09H
-1.05 23 79 21 PCT 17 BW9 1.65 24 81 21 PCT 17 BW6
-0.87 25 82 22 PCT 19 BW4 0.78 26 82 22 PCT 14 BW9 2.06 27 57 23 PCT 13 BW4
-0.79 28 79 23 PCT 18 BW9 1.56 29 76 24 PCT 19 BW4
-0.99 30 76 24 PCT 22 BW5
-0.9 31 76 24 PCT 20 BW6 0.87 32 19 25 PCT 27 BW5
-0.9 33 19 25 PCT 18 BW5 0.9 34 69 25 PCT 17 BW6 0.89 35 79 25 PCT 13 BW6 0.75 36 79 25 PCT 20 BW9 1.58 37 81 25 PCT 15 BW4
-0.82 38 101 25 PCT 36 BW1 1.91 39 80 26 PCT 20 08C
-0.91 40 82 26 PCT 16 BW5
-0.94 41 82 26 PCT 12 BW5 0.77 42 82 26 PCT 20 BW6
-0.86 43 82 26 PCT 26 BW6 0.89 44 23 27 PCT 13 BW5
-0.74 45 79 27 POT 22 BW9 1.76 46 81 27 PCT 12 BW4
-0.82 to W3Fl-2006-0024 Page 2 of 13 Percent of Wall-Thickness Penetrations for S/G #2 - RF1 3 Indication Row Column Indication
% TW Support Location 47 81 27 PCT 18 BW6 0.83 48 101 27 PCT 11 BW9 1.89 49 4
28 PCT 18 05C
-0.76 50 78 28 PCT 19 BW6
-0.87 51 78 28 PCT 14 BW9
-1.5 52 80 28 PCT 21 BW6 1.02 53 82 28 PCT 17 BW4
-0.9 54 82 28 PCT 19 BW5
-0.85 55 82 28 PCT 29 BW6 0.93 56 57 29 PCT 14 BW4
-0.79 57 77 29 PCT 21 BW6 0.86 58 48 30 PCT 16 BW5
-0.85 59 94 30 PCT 26 09C 0
60 94 30 PCT 16 09C 0.92 61 3
31 PCT 27 05C 0.99 62 43 31 PCT 10 BW5
-0.85 63 107 31 PCT 16 BWI
-1.41 64 46 32 PCT 24 BW5
-0.76 65 81 33 PCT 20 BW5
-0.83 66 81 33 PCT 21 BW5 0.84 67 81 33 PCT 13 BW9 1.99 68 83 33 PCT 11 BW5 0.89 69 52 34 PCT 14 BW6
-0.82 70 27 35 PCT 10 BW5 0.85 71 37 35 PCT 10 BW5 0.61 72 59 35 PCT 28 BW6 0.82 73 69 35 PCT 14 BW5 0.97 74 83 35 PCT 24 BW5 0.67 75 83 35 PCT 19 BW7
-0.79 76 83 35 PCT 17 BW7 1.09 77 100 36 PCT 12 BW5
-0.95 78 102 36 PCT 17 BW3 0.84 79 108 36 PCT 20 BW1 1.83 80 35 37 PCT 10 BW5
-0.77 81 43 37 PCT 22 BW5
-0.88 82 43 37 PCT 17 BW5 0.8 83 77 37 PCT 13 BW4
-0.88 84 77 37 PCT 16 BW4 0.91 85 77 37 PCT 14 BW5
-0.91 86 77 37 PCT 19 BW5 0.67 87 111 37 PCT 18 BW1 1.65 88 41 39 PCT 15 BW5 0.99 89 93 39 PCT 16 BW3
-0.81 90 117 39 PCT 15 BW5
-0.93 91 36 40 PCT 16 BW5 1.09 92 44 40 PCT 22 BW5
-1.03 to W3FI-2006-0024 Page 3 of 13 Percent of Wall-Thickness Penetrations for SIG #2 - RF13 Indication Row Column Indication
% TW Support Location 93 44 40 PCT 17 BW5 0.71 94 46 40 PCT 16 BW5 0.68 95 94 40 PCT 31 BW3
-0.92 96 94 40 PCT 16 BW5
-1.02 97 94 40 PCT 28 BW6 1.05 98 23 41 PCT 8
BW5
-0.8 99 31 41 PCT 10 BW5
-0.76 100 33 41 PCT 11 BW5 0.62 101 81 41 PCT 18 BW5
-0.94 102 81 41 PCT 20 BW5 0.92 103 81 41 PCT 18 BW6
-0.92 104 83 41 PCT 11 BW3 0.97 105 60 42 PCT 19 BW4 0.63 106 96 42 PCT 26 BW3
-0.81 107 96 42 PCT 19 BW3 0.78 108 96 42 PCT 30 BW5
-1.05 109 114 42 PCT 19 BW7 0.87 110 125 43 PCT 21 03C 0.73 111 22 44 PCT 14 BW5
-0.88 112 120 44 PCT 15 BW2 0.84 113 124 44 PCT 16 BW6 0.98 114 1
45 PCT 21 04C
-0.19 115 1
45 PCT 15 04C 0.81 116 67 45 PCT 17 BW5 0.81 117 119 45 PCT 16 BW4
-0.9 118 48 46 PCT 18 BW5
-1.1 119 80 46 PCT 25 08C
-0.88 120 77 47 PCT 13 BW4
-0.91 121 87 47 PCT 13 BW3 0.77 122 44 48 PCT 20 BW5 0.74 123 74 48 PCT 26 BW4 0.98 124 74 48 PCT 37 BW5 0.96 125 74 48 PCT 20 BW6 0.81 126 80 48 PCT 34 BW5
-1.08 127 110 48 PCT 12 BW3 0.9 128 3
49 PCT 18 05C
-0.91 129 77 49 PCT 14 BW5 0.83 130 79 49 PCT 13 BW6
-0.68 131 81 49 PCT 24 BW5 0.86 132 81 49 PCT 18 BW6
-0.71 133 81 49 PCT 12 BW6 0.86 134 81 49 PCT 19 08C 0.91 135 91 49 PCT 22 BW6 1.05 136 40 50 PCT 17 BW5 0.56 137 44 50 PCT 21 BW5
-0.56 138 66 50 PCT 24 BW9 1.55 to W3Fl -2006-0024 Page 4 of 13 Percent of Wall-Thickness Penetrations for SIG #2 - RF13 Indication Row Column Indication
% TW Support Location 139 128 50 PCT 19 BW6 1
140 47 51 PCT 13 BW5 0.89 141 77 51 PCT 23 BW4
-0.9 142 77 51 PCT 18 BW6
-0.85 143 83 51 PCT 9
BW7 1.03 144 97 51 PCT 22 BW3
-0.78 145 107 51 PCT 16 BW7
-0.72 146 44 52 PCT 25 BW5
-1.06 147 44 52 PCT 17 BW5 0.68 148 46 52 PCT 23 BW5
-0.95 149 46 52 PCT 13 BW5 0.87 150 48 52 PCT 17 BW5
-1.06 151 48 52 PCT 11 BW5 0.71 152 80 52 PCT 18 BW4 0.89 153 134 52 PCT 19 BW1 1.48 154 134 52 PCT 20 BW2 0.8 155 134 52 PCT 19 08C
-0.98 156 1
53 PCT 18 04C
-0.86 157 35 53 PCT 11 BW5
-0.92 158 35 53 PCT 9
BW5 0.98 159 73 53 PCT 13 BW5
-0.86 160 73 53 PCT 20 BW5 0.87 161 73 53 PCT 29 BW6
-0.84 162 73 53 PCT 12 BW6 0.15 163 73 53 PCT 20 BW6 0.81 164 36 54 PCT 16 BW5
-0.91 165 82 54 PCT 27 BW4 0.81 166 114 54 PCT 18 BW7 0.94 167 59 55 PCT 13 BW4 0.87 168 107 55 PCT 29 BW5 0.12 169 107 55 PCT 28 BW5 1.08 170 107 55 PCT 26 BW6
-0.91 171 129 55 PCT 19 09C 0.96 172 24 56 PCT 15 BW5
-0.79 173 70 56 PCT 15 BW5 0.83 174 94 56 PCT 11 BW3
-0.85 175 94 56 PCT 14 BW4
-0.88 176 128 56 PCT 18 BW3 0.68 177 132 56 PCT 17 BW2 0.79 178 73 57 PCT 10 BW5
-0.86 179 73 57 PCT 26 BW6 0.81 180 77 57 PCT 17 BW5
-0.89 181 81 57 PCT 28 BW4
-0.83 182 81 57 PCT 15 BW5
-0.88 183 83 57 PCT 19 BW3
-0.88 184 83 57 PCT 14 BW5
-0.82 to W3FI-2006-0024 Page 5 of 13 Percent of Wall-Thickness Penetrations for SIG #2 - RF 3 Indication Row Column Indication
% TW Support Location 185 87 57 PCT 13 BW3
-0.95 186 60 58 PCT 16 BW6 0.8 187 120 58 PCT 18 BW2 1.1 188 27 59 PCT 12 BW5 0.84 189 83 59 PCT 13 BW7
-1.02 190 105 59 PCT 20 BW5 0.73 191 124 60 PCT 17 BW6 0.77 192 77 61 PCT 32 BW4
-1.05 193 77 61 PCT 28 BW4 0.84 194 81 61 PCT 14 BW4 0.9 195 133 61 PCT 11 BW3 0.6 196 133 61 PCT 20 BW5 0.66 197 137 61 PCT 18 09C
-1.12 198 90 62 PCT 17 BW4 0.98 199 120 62 PCT 20 BW2 0.99 200 89 63 PCT 22 BW3
-0.65 201 137 63 PCT 15 09C
-1.12 202 40 64 PCT 21 BW5 0.85 203 46 64 PCT 24 BW5
-0.72 204 46 64 PCT 38 BW5 1.07 205 82 64 PCT 22 BW4
-0.73 206 82 64 PCT 32 BW4 0.03 207 82 64 PCT 36 BW4 0.97 208 82 64 PCT 28 BW6
-0.76 209 84 64 PCT 14 BW4
-0.78 210 120 64 PCT 20 BW2 0.83 211 138 64 PCT 12 BW7 0.9 212 19 65 PCT 28 BW5
-1 213 37 65 PCT 14 BW5
-0.87 214 92 66 PCT 12 BW7 1.08 215 112 66 PCT 18 BW3 0.75 216 112 66 PCT 17 BW7 0.85 217 138 66 PCT 18 BW2 0.87 218 142 66 PCT 19 BW8 0.62 219 79 67 PCT 12 BW5 0.7 220 119 67 PCT 15 09C 0.21 221 143 67 PCT 15 BW8 0.69 222 22 68 PCT 17 BW9 1.64 223 46 68 PCT 27 BW5
-0.75 224 46 68 PCT 22 BW5 0.12 225 46 68 PCT 33 BW5 1.01 226 88 68 PCT 16 BW3 0.75 227 88 68 PCT 14 BW4
-0.81 228 128 68 PCT 19 BW2 0.84 229 142 68 PCT 20 10C
-0.24 230 29 69 PCT 13 BW9
-1.89 to W3Fl -2006-0024 Page 6 of 13 Percent of Wall-Thickness Penetrations for SIG #2 - RF1 3 Indication Row Column Indication
% TW Support Location 231 41 69 PCT 21 BW9
-1.96 232 43 69 PCT 17 BW5
-1 233 43 69 PCT 28 BW5 0.88 234 45 69 PCT 15 BW9
-1.57 235 141 69 PCT 11 BW3
-0.84 236 141 69 PCT 17 BW5
-0.79 237 141 69 PCT 15 BW7 0.81 238 48 70 PCT 29 BW5
-0.98 239 48 70 PCT 21 BW5 0.86 240 134 70 PCT 19 BW2 0.77 241 77 71 PCT 15 BW4 0.82 242 77 71 PCT 15 BW5 0.69 243 77 71 PCT 12 BW6 0.81 244 139 71 PCT 15 BW2
-0.74 245 76 72 PCT 18 BW4 0.76 246 92 72 PCT 21 BW5
-0.76 247 100 72 PCT 15 BW4 0.8 248 130 72 PCT 19 BW3 0.78 249 134 72 PCT 20 BW2 0.71 250 144 72 PCT 12 BW2 0.73 251 99 73 PCT 15 BW3
-0.65 252 115 73 PCT 11 BW6
-0.9 253 141 73 PCT 14 05H
-0.18 254 102 74 PCT 13 BW3 0.88 255 141 75 PCT 18 BW1 1.83 256 143 75 PCT 15 09H 0.77 257 145 75 PCT 20 BW2
-0.72 258 87 77 PCT 9
BW5 1.01 259 89 77 PCT 10 BW3 0.87 260 143 77 PCT 19 BW2
-0.83 261 145 77 PCT 19 BW1 1.6 262 145 77 PCT 21 BW8
-0.84 263 145 77 PCT 9
08C
-0.18 264 145 77 PCT 15 08C 0.8 265 102 78 PCT 15 BW3
-0.87 266 110 78 PCT 15 BW6
-0.88 267 142 78 PCT 11 BW8
-1.02 268 146 78 PCT 20 BW9 1.81 269 143 79 PCT 15 08C 0.77 270 52 80 PCT 17 BW9 1.86 271 54 80 PCT 12 BW9 1.91 272 56 80 PCT 24 BW9 1.56 273 112 80 PCT 11 BW3
-0.93 274 146 80 PCT 15 BW9 1.73 275 53 81 PCT 15 BW9
-1.55 276 55 81 PCT 15 BW9
-1.81 to W3Fl -2006-0024 Page 7 of 13 Percent of Wall-Thickness Penetrations for S/G #2 - RF1 3 Indication Row Column Indication
% TW Support Location 277 97 81 PCT 18 BW3
-0.57 278 97 81 PCT 17 BW3 0.87 279 147 81 PCT 17 09H 0.74 280 146 82 PCT 25 BW1 1.62 281 53 83 PCT 22 BW9 0.85 282 55 83 PCT 15 BW9 0.14 283 59 83 PCT 16 BW9 4.03 284 61 83 PCT 14 BW9 4.09 285 63 83 PCT 7
BW9 3.85 286 73 83 PCT 11 BW6 0.8 287 73 83 PCT 7
BW9 0
288 81 83 PCT 15 BW4
-0.72 289 145 83 PCT 16 BW1 1.76 290 54 84 PCT 26 BW1
-2.12 291 54 84 PCT 22 BW9 2.51 292 54 84 PCT 9
BW9
-0.74 293 54 84 PCT 32 BW9 3.15 294 56 84 PCT 18 BW9
-0.78 295 56 84 PCT 24 BW9 1.99 296 56 84 PCT 26 BW9
-1.62 297 56 84 PCT 39 BW9 2.18 298 58 84 PCT 13 BW9 0.52 299 60 84 PCT 13 BW9
-1.44 300 60 84 PCT 21 BW9
-1.85 301 64 84 PCT 8
BW9 0.31 302 64 84 PCT 12 BW9 2.17 303 76 84 PCT 30 BW9
-1.35 304 76 84 PCT 31 BW9
-1.72 305 146 84 PCT 26 09H 0.88 306 146 84 PCT 16 BW9 1.78 307 55 85 PCT 23 BW9
-1.63 308 55 85 PCT 41 BW9 1.57 309 65 85 PCT 25 BW9 1.84 310 67 85 PCT 26 BW9 1.83 311 69 85 PCT 27 BW9 1.62 312 97 85 PCT 13 BW3 0.8 313 97 85 PCT 13 BW4 0.9 314 105 85 PCT 16 BW6
-0.97 315 145 85 PCT 11 BW1
-1.92 316 145 85 PCT 13 BW7 0.94 317 145 85 PCT 24 BW8
-0.88 318 145 85 PCT 28 BW8 0.94 319 145 85 PCT 21 BW9
-1.97 320 147 85 PCT 14 BW1
-1.64 321 147 85 PCT 16 BW6 1
322 147 85 PCT 21 BW7 0.94 to W3FI-2006-0024 Page 8 of 13 Percent of Wall-Thickness Penetrations for SIG #2 - RF13 Indication Row Column Indication
% TW Support Location 323 80 86 PCT 21 BW9
-1.6 324 142 86 PCT 16 BW7 0.8 325 144 86 PCT 20 BW1 1.58 326 65 87 PCT 21 BW9 1.94 327 81 87 PCT 15 BW6
-0.88 328 81 87 PCT 15 BW6 0.96 329 85 87 PCT 11 BW5 0.83 330 145 87 PCT 12 BW9
-1.61 331 147 87 PCT 13 BW1
-1.92 332 147 87 PCT 24 BW2
-0.83 333 147 87 PCT 18 BW7
-0.86 334 147 87 PCT 13 BW7 0.73 335 147 87 PCT 20 BW8
-0.9 336 147 87 PCT 27 BW8 0.03 337 58 88 PCT 14 BW9
-1.53 338 74 88 PCT 14 BW5
-0.71 339 144 88 PCT 12 BW9 1.9 340 146 88 PCT 29 BW1 1.63 341 146 88 PCT 31 BW9 1.98 342 53 89 PCT 26 BW9
-1.78 343 53 89 PCT 12 BW9 1.81 344 55 89 PCT 17 BW9
-1.91 345 55 89 PCT 25 BW9 0.31 346 143 89 PCT 12 09H 0.88 347 145 89 PCT 15 BW4
-0.9 348 145 89 PCT 18 BW7
-0.94 349 145 89 PCT 26 BW8
-0.97 350 145 89 PCT 17 BW8 1.07 351 145 89 PCT 13 08C
-0.94 352 60 90 PCT 15 BW9 1.85 353 146 90 PCT 14 BW9 1.6 354 57 91 PCT 19 BW9 1.74 355 81 91 PCT 11 BW4 1.14 356 81 91 PCT 10 BW5 0.99 357 119 91 PCT 19 08C
-1.01 358 137 91 PCT 15 BW2 0.77 359 147 91 PCT 25 BW8
-0.66 360 147 91 PCT 27 BW8 0.15 361 147 91 PCT 20 BW8 0.9 362 53 93 PCT 12 BW1 1.98 363 81 93 PCT 15 BW4
-0.74 364 81 93 PCT 13 BW4 0.88 365 54 94 PCT 41 BW9 1.72 366 53 95 PCT 24 BW1
-1.64 367 79 95 PCT 13 BW4
-1.02 368 145 95 PCT 21 BW8
-0.89 to W3F1-2006-0024 Page 9 of 13 Percent of Wall-Thickness Penetrations for SIG #2 - RF13 Indication Row Column Indication
% TW Support Location 369 145 95 PCT 11 BW8 1.08 370 66 96 PCT 15 BW1 2.03 371 49 97 PCT 35 BW1
-1.98 372 67 97 PCT 15 02H
-0.74 373 81 97 PCT 19 BW4 1.11 374 81 97 PCT 26 BW5 1
375 81 97 PCT 15 BW6
-0.88 376 85 97 PCT 16 BW4 1.01 377 51 99 PCT 28 BW9 1.79 378 110 100 PCT 14 BW7 0.98 379 144 100 PCT 8
BW9
-1.7 380 145 101 PCT 11 BW3 0.91 381 88 102 PCT 14 BW3 0.65 382 110 102 PCT 12 BW4 0.91 383 143 103 PCT 14 BW9
-1.87 384 145 103 PCT 21 BW9 1.94 385 72 104 PCT 17 BW5 0.83 386 48 106 PCT 20 BW5 0
387 114 106 PCT 21 BW4
-0.18 388 41 107 PCT 23 BW5
-0.85 389 41 107 PCT 14 BW5 0.06 390 77 107 PCT 13 BW4
-0.55 391 77 107 PCT 23 BW5
-0.77 392 77 107 PCT 36 BW5 0.09 393 77 107 PCT 36 BW5 0.74 394 77 107 PCT 19 BW6
-0.63 395 83 107 PCT 20 BW3
-0.99 396 91 107 PCT 18 BW3 0.8 397 40 108 PCT 34 BW5
-0.94 398 40 108 PCT 33 BW5 0.95 399 42 108 PCT 28 BW5
-0.36 400 42 108 PCT 23 BW5 0.58 401 21 109 PCT 21 BW5 0.78 402 45 109 PCT 14 BW5 0.81 403 53 109 PCT 16 BW5 0.88 404 113 109 PCT 27 BW3 0.75 405 115 109 PCT 17 BW8 1.05 406 24 110 PCT 18 BW5
-0.71 407 82 110 PCT 13 BW6 0.89 408 19 111 PCT 27 BW5 0.91 409 41 111 PCT 20 BW5 0.84 410 121 111 PCT 13 BW7 0.71 411 32 112 PCT 21 BW5 0.56 412 100 112 PCT 14 BW3 0.56 413 100 112 PCT 14 08C 0.84 414 114 112 PCT 18 BW3 0.7 to W3Fl-2006-0024 Page 10 of 13 Percent of Wall-Thickness Penetrations for SIG #2 - RF1 3 Indication Row Column Indication
% TW Support Location 415 3
113 PCT 18 06C 0.21 416 19 113 PCT 15 BW5
-1.13 417 19 113 PCT 14 BW5 0.85 418 81 113 PCT 28 BW4 0.95 419 135 113 PCT 20 BW8
-0.24 420 25 115 PCT 11 BW5
-0.88 421 123 115 PCT 10 08C
-0.96 422 46 116 PCT 23 BW5 0.89 423 106 116 PCT 13 BW7
-0.99 424 3
117 PCT 14 05H 0.25 425 19 117 PCT 27 BW5
-0.91 426 37 117 PCT 12 BW5 0.81 427 77 117 PCT 36 BW6
-0.61 428 133 117 PCT 17 BW3 1.02 429 74 118 PCT 25 BW4
-0.65 430 74 118 PCT 28 BW5
-0.82 431 74 118 PCT 15 BW6 0.82 432 59 119 PCT 15 BW6 0.74 433 49 121 PCT 16 BW5 0.73 434 40 122 PCT 14 BW5 0.75 435 104 122 PCT 16 BW3
-0.96 436 118 122 PCT 17 BW2 0.89 437 130 124 PCT 16 BW2 0.96 438 134 124 PCT 17 BW5 0.99 439 23 125 PCT 8
BW5
-0.88 440 37 125 PCT 15 BW5
-0.81 441 127 125 PCT 10 06C
-1.07 442 72 126 PCT 12 BW4 0.87 443 98 126 PCT 8
BW6 0.84 444 98 126 PCT 11 BW7 0.91 445 100 126 PCT 14 BW3 0.94 446 102 126 PCT 11 BW5 0.94 447 41 127 PCT 15 BW5 0.76 448 57 127 PCT 15 BW4 1.06 449 59 127 PCT 12 BW4 0.66 450 65 127 PCT 14 BW4
-0.67 451 69 127 PCT 17 BW4 0.92 452 107 127 PCT 11 BW4 0.9 453 109 127 PCT 11 BW6 0.93 454 109 127 PCT 9
BW7 0.87 455 22 128 PCT 17 02H 0.84 456 48 128 PCT 44 BW5 0.06 457 48 128 PCT 48 BW5 0.8 458 82 128 PCT 30 BW5 0.82 459 82 128 POT 22 BW6 0.78 460 88 128 PCT 16 BW3 0.87 to W3F1-2006-0024 Page 11 of 13 Percent of Wall-Thickness Penetrations for SIG #2 - RF13 Indication Row Column Indication
% TW Support Location 461 100 128 PCT 17 BW3 0.69 462 118 128 PCT 17 BW3 0.87 463 31 129 PCT 8
BW5 0.76 464 35 129 PCT 11 BW5 0.85 465 43 129 PCT 13 BW5
-0.84 466 59 131 PCT 12 BW4 0.9 467 95 131 PCT 10 BW3 0.87 468 111 131 PCT 11 BW3 0.87 469 113 131 PCT 11 BW6 1.02 470 125 131 PCT 14 02C 0.74 471 88 132 PCT 21 BW3
-0.92 472 88 132 PCT 18 BW3 0.62 473 89 133 PCT 14 BW3
-0.87 474 89 133 PCT 11 BW3 0.67 475 89 133 PCT 11 BW4 1
476 101 133 PCT 13 BW3 0.86 477 111 133 PCT 13 BW3 0.75 478 125 133 PCT 17 BW4
-0.8 479 74 134 PCT 15 BW5
-0.78 480 98 134 PCT 14 BW3
-0.98 481 98 134 PCT 18 BW3 0.57 482 100 134 PCT 17 07C
-0.18 483 102 134 PCT 19 BW3 0.54 484 101 135 PCT 12 BW3 0.91 485 70 136 PCT 17 BW4
-0.81 486 88 136 PCT 18 BW3 0.83 487 90 136 PCT 20 BW3 0.62 488 92 136 PCT 21 BW4
-0.84 489 92 136 PCT 22 07C 0.93 490 96 136 PCT 19 BW3 0.59 491 96 136 PCT 14 BW7
-0.89 492 96 136 PCT 16 BW7 0.54 493 98 136 PCT 16 BW3
-0.98 494 98 136 PCT 18 BW3 0.62 495 98 136 PCT 14 BW7
-1.02 496 98 136 PCT 16 BW7 0.63 497 104 136 PCT 16 BW3 0.81 498 120 136 PCT 17 BW6 0.92 499 27 137 PCT 13 BW1
-0.61 500 77 137 PCT 13 BW4
-0.71 501 85 137 PCT 13 BW3
-0.92 502 97 137 PCT 13 BW3
-0.83 503 109 137 PCT 13 BW3 0.94 504 70 138 PCT 15 BW5 0.09 505 37 139 PCT 11 BW5 0.85 506 41 139 PCT 17 BW5 0.79 to W3Fl-2006-0024 Page 12 of 13 Percent of Wall-Thickness Penetrations for SIG #2 - RF 3 Indication Row Column Indication
% TW Support Location 507 49 139 PCT 11 BW5
-0.77 508 53 139 PCT 12 BW5 0.87 509 57 139 PCT 13 BW4 0.72 510 79 139 PCT 22 08C
-0.21 511 89 139 PCT 18 BW5 0.81 512 111 139 PCT 10 BW3
-0.84 513 16 140 PCT 14 BW1
-0.69 514 70 140 PCT 11 BW4 0.85 515 106 140 PCT 14 BW3 0.85 516 23 141 PCT 15 03H 1.04 517 37 141 PCT 21 BW5
-0.85 518 77 141 PCT 10 BW6
-0.82 519 109 141 PCT 15 BW5 0.88 520 50 142 PCT 17 BW5
-0.9 521 66 142 PCT 15 08C 0.78 522 47 143 PCT 44 BW5 1.08 523 49 143 PCT 37 BW5 0.9 524 85 143 PCT 14 BW3
-0.92 525 89 143 PCT 12 BW3
-0.83 526 105 143 PCT 20 09H
-0.8 527 105 143 PCT 12 09H 0
528 105 143 PCT 16 BW3 0.91 529 105 143 PCT 14 BW6
-0.9 530 34 144 PCT 12 BW5
-0.73 531 88 144 PCT 13 BW3 0.8 532 96 144 PCT 12 BW6 0.75 533 96 144 PCT 15 08C
-0.95 534 104 144 PCT 11 04H 0.89 535 45 145 PCT 33 BW5
-0.9 536 45 145 PCT 26 BW5 0.8 537 84 146 PCT 8
BW9
-1.7 538 47 147 PCT 22 BW5
-0.88 539 47 147 PCT 27 BW5 0.91 540 67 147 PCT 18 BW4 0.96 541 91 147 PCT 19 09C
-0.69 542 103 147 PCT 20 09C
-0.87 543 104 148 PCT 16 BW4 0.92 544 41 149 PCT 37 BW5 1.15 545 43 149 PCT 20 BW5 1.17 546 49 149 PCT 32 BW5 1.08 547 93 149 PCT 16 BW3
-0.81 548 101 149 PCT 18 09C
-1.03 549 101 149 PCT 20 09C 0.74 550 103 149 PCT 13 02H 0.79 551 103 149 PCT 27 09H
-0.18 552 103 149 PCT 12 09H 0.86 to W3F1-2006-0024 Page 13 of 13 Percent of Wall-Thickness Penetrations for SIG #2 - RF1 3 Indication Row Column Indication
% TW Support Location 553 76 150 PCT 16 BW4
-0.67 554 80 150 PCT 14 08H 0.95 555 92 150 PCT 16 BW3 0.97 556 96 150 PCT 17 BW3 0.89 557 67 151 PCT 18 BW6 0.96 558 75 151 PCT 15 BW4 0.74 559 87 151 PCT 13 BW7 0.86 560 96 152 PCT 12 09H
-0.06 561 59 153 PCT 19 BW4 0.92 562 83 153 PCT 13 BW1
-0.03 563 40 154 PCT 19 BW5 1.13 564 58 154 PCT 13 BW6 0.83 565 64 154 PCT 11 BW6
-0.83 566 37 155 PCT 25 BW5
-0.83 567 67 155 PCT 16 BW4
-0.89 568 67 155 PCT 19 BW4 0.86 569 87 155 PCT 16 BW3 0.82 570 66 156 PCT 13 08C
-0.21 571 76 156 PCT 16 BW4 0.72 572 37 157 PCT 24 BW5
-0.91 573 37 157 PCT 16 BW5 0.99 574 85 157 PCT 11 09C
-1.15 575 86 158 PCT 11 BW5
-0.9 576 71 159 PCT 12 BW4
-0.76 577 71 159 PCT 11 BW4 0.79 578 83 159 PCT 30 BW9 1.81 579 70 160 PCT 20 08C 0.74 580 72 160 PCT 15 BW5 0.9 581 80 160 PCT 20 BW9 1.66 582 76 162 PCT 10 BW1
-1.73 583 76 162 PCT 14 BW9 1.58 584 14 164 PCT 14 04C
-0.3 585 52 164 PCT 15 BW9 1.75 586 68 164 PCT 17 BW6
-0.71 587 68 164 PCT 16 BW6 0.95 588 41 167 PCT 23 BW5 0.99 589 45 167 PCT 28 BW5
-0.94 590 14 168 PCT 8
03H 0.85 591 34 170 PCT 15 BW5 0.97 592 18 174 PCT 15 02C
-0.83 593 1
175 PCT 15 01H 0.3 594 3
175 PCT 10 01H
-0.83 595 11 175 PCT 20 BW1 1.12 To W3Fl-2006-0024 Summary of RF13 Plugging Repairs to W3FI-2006-0024 Page 1 of 1 Summary of RF13 Plugging Repairs Extracted from SG-SGDA-05-23, SG Condition Monitoring Report and Interim Cycle 14 Operational Assessment SG-SG"05-23 Table 1:
Summary of Waterford 3 RF13 Plugging Repair Statistics:
NIrber of Tubes Repaired for All Reasms in Base Scope Eddy Current Inspection Program SG 31 Degradation 1de HL sludge pile ILTIS BEp.
CLTISExp.
Hbt Leg Cold Leg Freespan Baing Ubend Total (above TIS)
Transition and Transition Eggcrate Eggcrate To Tubesheet Axial ODSCC I
I O
81 2
O O
O l
85 Axial PSOC 0
3
° 0
0 O3 O
=
Circ. PWSCC 0
0 0
0 0
0 0
1 Wear.
O O
O O
O O
2 O
2 l
PreventiveNIE 0
O O
O O
O 5
l PreventivePIP 09 O
O O
O O
O 9
Volunmtric 0
O 4
O O
O
° 0
4 DataQaality O0 O
1 O
O 2
1 2
O O
4 SubTotal I10 2_ _4 _8 2_20 183(1 35 7
SG321 Axial ODS;CC l
2 l
O l
O 17 l
3 l
0 l3 1 ° 0 25 Axial PWSCC 1tu 0
a h e O
l OO lO (2: ICuDSCC l
aO l O
B O
l O
l O
Circ. MWCC 0
I 0
0 0
0 0
0 1
Weer 0
O 0
O 0
3 5 (2) l 0
8 PreventiveNIE 0
19 0
0 ° 0
° 0
19 LPreventive PLP l
0 I
0 O
l O
l 0
2 l
Volurnetric l
O 0
° 0
O l
O 0
l DataQuality I
O l
O l
O 1
1 l
O 0
2 l
Sub Total l
2 2
21 0 _
1 8 3
l 5
l 7
l 0
57 l
(1): Icudes I tubewmith cirti=al PWSCC in thctubesheet plus axial ODSCC at hot legceggaratc (2): Includes onetube preventively repaired Et 37fioTWet BW5.
Page 7of48 To W3FI-2006-0024 Summary of NDE Techniques to W3Fl-2006-0024 Page 1 of 1 Summary of NDE Techniques Mechanism Probe ETSS Thinning / Loose Part Wear Bobbin 96001.1 Rev. 10 Wear at Tube Support Structures Bobbin 96004.1 Rev. 9 Axial ODSCC at Dented Locations s5.0 Volts in the Freespan Bobbin 24013.1 Rev. I Axial ODSCC at Non-Dented EC and Sludge Pile Bobbin 96008.1 Rev. 13 Pitting in the Presence of Copper Bobbin 96005.2 Rev. 8 Axial PWSCC at Dented Support Structures <2.0 Volts Bobbin 96012.1 Rev. 10 Wear at Tube Support Structures
+Point 96910.1 Rev. 8 Volumetric at Freespan Regions
+Point 21998.1 Rev. 3 Axial ODSCC at Support Structures, Freespan, Sludge Pile and Tubesheet
+Point 21409.1 Rev. 4 Crevice Circ. ODSCC at Expansion Transitions
+Point 21410.1 Rev. 4 Circ. PWSCC at Expansion Transition
+Point 20510.1 Rev. 5 Axial PWSCC at Expansion Transition
+Point 20511.1 Rev. 7 Circ. PWSCC at Dented Locations
+Point 20510.1 Rev. 5 Axial PWSCC at Dented Locations
+Point 96703.1 Rev. 15 Axial/Circ. PWSCC at Low Row U-bends
+Point 96511.2 Rev. 14 Axial ODSCC at Dented Support Locations
+Point 22401.1 Rev. 3