EOC-RPT Instrumentation 3.3.4.2 3.3 INSTRUMENTATION 3.3.4.2 End of Cycle Recirculation Pump Trip (EOC-RPT) Instrumentation LCO 3.3.4.2
- a. Two channels per trip system for each EOC-RPT instrumentation Function listed below shall be OPERAKLE:
- 1. Turbine Stop Valve (TSV)-Closure; and
- 2. Turbine Control Valve (TCV) Fast Closure, Trip Oil Pressure-Low.
- b. The following limits are made applicable:
- 1. LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)," limits for inoperable EOC-RPT as specified in the COLR;
limits for inoperable EOC-RPT as specified in thE COLR; and
limits for inoperable EOC-RPT as specified in the COLR.
I I
APPLICABILITY:
THERMAL POWER 2 29.5% RTP.
ACTIO0S
NOTE-------------------------------------
Separ3te Condition entry is allowed for each channel.
CONDITION REQUIRED ACTION COMPLETION TIME A. One or more channels A.1 Restore channel to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> inoperable.
OPERABLE status.
OR A.2
NOTE---------
Not applicable if inoperable channel is the result of an inoperable breaker.
Place channel-in 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> trip.
(continued)
PBAPS UJNIT 2 3.3-31a Amendment No. 258
Recirculation Loops Operating 3.4.1 3.4 REACTOR COOLANT SYSTEM (RCS) 3.1.1 Recirculation Loops Operating LCCI 3.4.1 Two recirculation loops with matched flows shall be in operation.
OR One recirculation loop shall be in operation with the following limits applied when the associated LCO is applicable:
- a.
LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)," single loop operation limits specified in the COLR;
- b.
LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR),- single loop operation limits specified in the COLR;
- c.
LCO 3.2.3, "LINEAR HEAT GENERATION RATE (LHGR)," single loop operation limits specified in the COLR; and
- d.
LCO 3.3.1.1, "Reactor Protection System (RPS)
Instrumentation," Function 2.b (Average Power Range Monitors Simulated Thermal Power-High), Allowable Value of Table 3.3.1.1-1 is reset for single loop operation.
NOTE----------------_
Required limit modifications for single recirculation loop operation may be delayed for up to 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after transition from two recirculation loop operation to single recirculation loop operation.
APPLICABILITY:
MODES 1 and 2.
PBAPS UNIT 2 3.4-1 Amendment No. 258
Main Turbine Bypass System 3.7.6 3.7 PLANT SYSTEMS 3.7.1 Main Turbine Bypass System LCO 3.7.6 The Main Turbine Bypass System shall be OPERABLE.
The following limits are made applicable:
- a.
LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RAT-E (APLHGR)," limits for an inoperable Main Turbine Bypass System, as specified in the COLR;
- b.
LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR)," limits for an inoperable Main Turbine Bypass System, as specified in the COLR; and
- c.
LCO 3.2.3, "LINEAR HEAT GENERATION RATE (LHGR)," limits for an inoperable Main Turbine Bypass System, as specified in the COLR.
I I
APPLICABILITY:
THERMAL POWER 2 25X RTP.
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Requirements of the A.1 Satisfy the 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> LCO not met.
requirements of the LCO.
B. Required Action and B.1 Reduce THERMAL POWER 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />
-associated Completion to < 25% RTP.
Time not met.
PBAPS UNIT 2 3.7-12 Amendment No. 258
+
EOC-RPT Instrumentation 3.3.4.2 3.3 INSTRUMENTATION 3.3.4.2 End of Cycle Recirculation Pump Trip (EOC-RPT) Instrumentation LCO 3.3.4.2
- a.
Two channels per trip system for each EOC-RPT instrumentation Function listed below shall be OPERABLE:
- 1. Turbine Stop Valve (TSV)-Closure; and
- 2. Turbine Control Valve (TCV) Fast Closure, Trip Oil Pressure-Low.
- b.
The following limits are made applicable:
- 1. LCO 3.2.1, -AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)," limits for inoperable EOC-RPT as specified in the COLR; I
limits for inoperable EOC-RPT as specified in the COLR; and I
limits for inoperable EOC-RPT as specified in the COLR.
I APPLICABILITY:
THERMAL POWER 2 29.5% RTP.
ACTIONS
NOTE-------------------------------------
Separate Condition entry is allowed for each channel.
CONDITION REQUIRED ACTION COMPLETION TIME A. One or more channels A.1 Restore channel to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> inoperable.
OPERABLE status.
OiR A.2
NOTE---------
Not applicable if inoperable channel is the result of an inoperable breaker.
Place channel in 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> trip.
(continued)
PBAPS UN IT 3 3.3-31a Amendment No. 261
Recirculation Loops Operating 3.4.1 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.1 Recirculation Loops Operating LCO 3.4.1 Two recirculation loops with matched flows shall be in operation.
Di One recirculation loop shall be in operation with the following limits applied when the associated LCO is applicable:
- a.
LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)," single loop operation limits specified in the COLR;
- b.
LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR)," single loop operation limits specified in the COLR; C.
LCO 3.2.3, "LINEAR HEAT GENERATION PATE (LHGR)," sincle loop operation limits specified in the COLR; and
- d.
LCO 3.3.1.1, "Reactor Protection System (RPS)
Instrumentation," Function 2.b (Average Power Range Monitors Simulated Thermal Power-High), Allowable Value of Table 3.3.1.1-1 is reset for single loop operation.
NOTE---------------
Required limit modifications for single recirculation loop operation may be delayed for up to 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after transition from two recirculation loop operation to single recirculation loop operation.
APPLICABILITY:
MODES 1 and 2.
PBAPS UNIT 3 3.4-1 Amendment No. 261
Main Turbine Bypass System 3.7.6 3.7 PLANT SYSTEMS 3.7.6 Main Turbine Bypass System LCO 3.7.6 The Main Turbine Bypass System shall be OPERABLE.
The following limits are made applicable:
- a.
LCO 3.2.1, -AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)," limits for an inoperable Main Turbine Bypass System, as specified in the COLR;
- b. LCO 3.2.2, -MINIMUM CRITICAL POWER RATIO (MCPR)," limits for an inoperable Main Turbine Bypass System, as specified in the COLR; and
- c. LCO 3.2.3, -LINEAR HEAT GENERATION RATE (LHGR)," limits for an inoperable Main Turbine Bypass System, as specified in the COLR.
I I
APPLICABILITY:
THERMAL POWER > 25% RTP.
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIM1E A. Requirements of the A.1 Satisfy the 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> LCO not met.
requirements of the LCO.
B. Required Action and B.1 Reduce THERMAL POWER 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> associated Completion to < 25% RTP.
Time not met.