  • E ntergy Entergy Nuclear Northeast Entergy Nuclear COperations, Inc.

James A. Fitzpatrick NPP RO. Box 110 Lycoming, NY 130E'3 Tel 315 349 6024 Fax 315 349 6480 April 12, 2006 JAFP-06-0062 T.A. Sullivan Site Vice President - JAF U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001

Subject:

James A. FitzPatrick Nuclear Power Plant Docket No. 50-333 Response to Request for Additional Information Regarding Proposed License Amendment: Changes to the Reactor Vessel Material Surveillance Program (TAC No. MC9682)

Reference Entergy Nuclear Operations, Inc. letter to USNRC (JAFP-06-0016),

Proposed License Amendment: Changes to the Reactor Vessel Material Surveillance Program, dated January 26, 2006.

Dear sir:

By letter dated January 26, 2006 (Reference), Entergy Nuclear Operations, Inc. (ENO) proposed to amend the licensing bases for the James A. FitzPatrick Nuclear Power Plant (JAFNPP) by changing to the BWRVIP reactor vessel material surveillance program.

On Ma:ch 27, 2006, a telecom was held per your Staff's request to obtain additional clarification regarding the reference letter. Attachment 1 to this letter provides the additional information requested during that telecom to clarify the previous proposed change to FSAR section 4.2.7.

If you have any questions in this regard, please contact Mr. Jim Costedio at (315) 349-6358.

Sincerely, Site Vice President TS:RP:dmr Attachments: 1. Updated FSAR change to section 4.2.7 (Insert 1)

/oDDS cc:

Regional Administrator, Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Office of the Resident Inspector U. S. Nuclear Regulatory Commission P. 0. Box 136 Lycoming, NY 13093 Mr. Paul Eddy New York State Department of Public Service 3 Empire State Plaza, I 0th Floor Albany, New York 12223 Mr. Peter R. Smith, President NYSERDA 17 Columbia Circle Albany, NY 12203-6399 Mr. John Boska, Project Manager Plant Licensing Branch I-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Mail Stop O-8-C2 Washington, DC 20555